DG Set Control Panel Dealers in Ambala (1 products available)

  • DG Set Control Panel

    DG Set Control Panel

    Get Price Quote

    The company has come up as a highly reliable Manufacturer and Supplier of DG Set Control Panel. The Automatic Main Failure DG Set Control Panel is known for highly efficient and effective in power supply restoration. The complete automation backs up the mains failure, and that makes the DG Set Control Panel worth investing in. Safety Information : Mains failure is described as : Direct failure of mains One or more phase of mains being unavailable Phase voltage of mains being out of preset limits (Provisions to set higher and lower phase voltage limits as per site requirement) Within range mains supply shall be considered healthy so that continuous running of engine alternator set is avoided Load shift to engine supply after suitable time delay, if the engine has started in the event of mains/phase failure or low/high voltage Switch load back to mains supply and stop the engine when the healthy supply is restored Up to three attempts for starting engine after failure of earlier attempts after suitable time intervals Two level fuel sensors for fuel at 50% & 25% respectively   Settable Features : Mains failure time – to initiate automatic EA start after 0 to 300 seconds of mains failure Mains restore time – to initiate automatic stop of EA after 0 to 300 seconds of mains in stable conditions Low oil pressure delay time – 0 to 99 seconds delay of the low pressure oil input alarm from engine start Stop solenoid time – 10 to 99 seconds enabling time for "stop solenoid" Cranking up time – 0 to 99 seconds enabling time for starter (timer is reset if the engine starts before the programmed time) Start attempts – 1 to 3 numbers of automatic attempts during automatic start cycle Attempts interval – 1 to 99 seconds time interval between starting pulse attempts Cooling down time – 0 to 300 seconds engine cooling time before stopping (engine runs without load) Generator voltage time – time of stable generator voltage to close EA contactor to load (0 to 300 seconds) Multifunctional meter to indicate Voltage, Current, PF, Frequency & kWh of DG Set Safety control trip – Low lubricating oil pressure, high cylinder / water temperature, lack of fuel, alternator fault and over speed Alarms : LLOP DG on DG battery low DG fuel low Under speed/over speed Stop fault Start fault Engine temperature high Alternator fault BTS battery low Mains OK/mains faulty Overload Over/under voltage Under/over frequency

    more..
Filter by Locality
top