Ionization Detectors Dealers in Delhi (4 products available)

  • Ionization Smoke Detector

    Ionization Smoke Detector

    Get Price Quote

    We are offering best Ionization Smoke Detector The Context Plus XP95 ionisation smoke detector has a moulded selfextinguishing white polycarbonate case with wind resistant smoke inlets. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Inside the detector case is a printed circuit board that has the ionisation chamber mounted on one side and the address capture, signal processing and communications electronics on the other. The ionisation chamber system is an inner reference chamber contained inside an outer smoke chamber. The outer smoke chamber has smoke inlet apertures that are fitted with an insect resistant mesh. The radioactive source holder and the outer smoke chamber are the positive and negative electrodes respectively. An Americium 241 radioactive source mounted within the inner reference chamber irradiates the air in both chambers to produce positive and negative ions. On applying a voltage across these electrodes an electric field is formed. The ions are attracted to the electrode of the opposite sign, some ions collide and recombine, but the net result is that a small electric current flows between the electrodes. At the junction between the reference and smoke chambers is the sensing electrode that is used to convert variations in the chamber currents into a voltage. When smoke particles enter the ionisation chamber, ions become attached to them with the result that the current flowing through the chamber decreases. This effect is greater in the smoke chamber than in the reference chamber and the imbalance causes the sensing electrode to go more positive.  

    more..
  • Ionization Smoke Detector

    Ionization Smoke Detector

    Get Price Quote

    System Sensor 200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector̢۪s address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Model 1251B ionization detector incorporates a unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. Specification Height : 2.0 inches (51mm) Diameter 6.1 Inches installed in B210LP base4.1 inches (104 mm) installed in B501 base Shipping Weight Heat 4.8 oz. (136 g)Photo/phot with heat 5.2oz. (147 g) ion 5.4 oz. (153 g) Operating Temprature Range Ion Photeo : 32-1200F (0-490C)Photo with Thermal 32-1000F (0-380C)Thermal : -4-1000F (-20-380C)High Temprature : -4-1500F (-20-660C) UL Listed Velocity Range Ion : 0 - 1200 fpm (0 - 6.1 m/secPhoto with Thermal : 4000 fpm Suitabe For Installation in ducts Insect Screen Hole Size Photo : 0.016 inch (0.41mm) nominalIon : 0.035 Inch (0.8mm) nominal Relative Humidity : 10-93% noncondensing Thermal Rating Fixed Temprature Setpoint : 1350F (570C)Rate of Rise Detection : 150F/min (8.30C/min.)High Temprature Heat : 1900F (880C) Voltage Range : 15-32 Volts DC Peak Standby Current (Max. Avg.) Ion/Thermal : 150 pA @ 24 VDC (without communication, LED off) 150 pA @ 24 VDC (one communication every 5 sec. with LED enabledPhoto/Photo With Thermal : 250 pA @ 24 VDC (without communication LED off), 300 pa @ 24 VDC (one communication every 5 sec. with LED Enables) LED Current (Max.) : 6.5 mA @ 24 VDC (on)

    more..
  • Best Deals from Ionization Detectors

  • Ionization Detector

    Ionization Detector

    Get Price Quote

    Ionization Detector, C Mount Camera, switchers, Connectors

    more..
  • ionization smoke detectors

    ionization smoke detectors

    Get Price Quote

    ionization smoke detectors, duct detector, main control panel

    more..
Filter by Locality
top