Skin Graft Blade Dealers in Delhi (9 products available)

  • Skin Graft Blades

    Skin Graft Blades

    1,000 Per Units

    25 Units (MOQ)

    • Type: Blade No. 10
    • Material: Stainless Steel
    • Country of Origin: Made in India
    • Item Code: AE-352
    • Usage/Application: Orthopaedics
    • Blade Type: Skin Graft
    • Shapes: Straight Blade
    • Brand Name: AE
    •  :  
    more..
  • skin graft blade

    skin graft blade

    Get Price Quote

    • Model Number: Skin Graft Blade/Knives
    • Port: NEW DELHI
    • Packaging Details: 100 PCS IN A BOX BULK PACK
    • Lead Time: 45 DAYS
    • Supply Ability: 100 Box/Boxes per Day
    • Properties: Burns Surgery Instruments

    available in both carbon and stainless steel, we have developed expertise in the field of supplying high quality skin graft blades/knives. skin graft bladedesigned to fit braithwaite, cobbett & watson handles. Available in both carbon and stainless steel supplied sterile in box of 10. Individually v.c. I paper wrapped, packed in a medial grade pouch. featuresmade of stainless steel. It consists of a handle and stem, on which is mounted and adjustable roller, for adjusting the thickens of graft, and a blade holder. usesit is used for taking split skin grafts used for coverage of raw surface composed of healthy vascularized or clean granulations to obtains healing and limit deformity and disability procedureafter preparing the donor site as in any operative case, the limp is held firmly by the assistant. The surgeon places a wooden board just in front of the skin grafting knife as shown in figure. The ribbel's skin grafting knife is held pressed firmly against the skin and the graft is removed with a steady to and for sawing motion. The desired thickness of the graft can be obtained by adjusting the depth of the knife. A very thin graft is translucent and the knife blade underneath appears bluish grey in colour. It leaves behind numerous small closely packed or confluent bleeding points. A thicker graft appears white and the bleeding points on the donor surface are few and far between. The subcutaneous fat is seen in case if a full thickness graft.

    more..
  • Best Deals from Skin Graft Blade

  • Skin Graft Blades

    Skin Graft Blades

    Get Price Quote

    Skin Graft Blade, Simplex, Duplex :Surgical Skin Graft Blades are 158 mm long, individually wrapped in VCI paper in single peel packets in packs of 10.These blades can be used with Watson, Braithwaite or Cobbett Handles. A convenient number of individual pouches are boxed in a unit carton. The surgical Skin Graft Blades are sterilized by gamma radiation to a minimum dosage of 2.5M Rad and has a shelf life of 5 years. The Skin Graft Blades of 158 mm in size are used in the surgical removal of a patch of healthy skin from one area of the patient’s body, usually the buttocks or inner thigh, which is then transplanted to another. Skin grafts may be recommended for Burns, specific surgeries that may require skin grafts for healing to occur and for areas of prior infection with extensive skin loss.These blades can be used with Watson, Braithwaite or Cobbett Skin Graft Handles.

    more..
  • MINI SKIN GRAFT SURGICAL BLADE

    MINI SKIN GRAFT SURGICAL BLADE

    Get Price Quote

    Fits no.3 handle fitment, 5cm long cutting edge (optional both side sharp edge), Available with or without plastic handle, made from stainless steel, supplied sterile 10 pcs in a box. RECOMENDATIONS FOR CLEANING AND STERILIZATION OF SURGICAL HANDLES Where appropriate, surgical handles should be thoroughly using warm soapy water To avoid damage to the handles during cleaning or sterilization a tumbling action is not recommended Handles that have been cleaned should the thoroughly inspected for any damage or wear. Re- Sterilization of surgical skin graft knife handles by moist heat should be carried out in accordance with BS EN 554 : 1994 Before use, all handles should be checked and inspected to ensure that the blade is attached to the handle correctly and securely Handles that have become worn or damaged should not be used Warnings The equipment must be operated under the jurisdiction of a qualified or licensed person and by an operator who has the skill required for the medical procedure, and that he or she must act according to the operating procedure defined by the qualified or licensed person. Sterilize before use.

    more..
  • skin graft blade

    skin graft blade

    Get Price Quote

    Surgical Skin Graft Blades are 158 mm long.Individually wrapped in VcI paper in single peel packets. These blades can be used with Watson, Braithwaite or cobbett Knives.

    more..
  • Skin Graft Blades

    Skin Graft Blades

    Get Price Quote

    Skin Graft Blade, Simplex, Duplex :Surgical Skin Graft Blades are 158 mm long, individually wrapped in VCI paper in single peel packets in packs of 10.These blades can be used with Watson, Braithwaite or Cobbett Handles. A convenient number of individual pouches are boxed in a unit carton. The surgical Skin Graft Blades are sterilized by gamma radiation to a minimum dosage of 2.5M Rad and has a shelf life of 5 years.

    more..
  • Skin Graft Blades

    Skin Graft Blades

    Get Price Quote

    Skin Graft Blades, Medical Instruments, nasal cannulas, disposable scalpels

    more..
  • Gibson Skin Graft Knife Blades

    Get Price Quote

    Gibson Skin Graft Knife Blades, Ultra Digital Thermometer

    more..
  • Skin Graft Blades

    Get Price Quote

    Skin Graft Blades, disposable surgical devices, Post Mortem Blades

    more..
Filter by Locality
top