WR1 Series Flow Indicator
20 Piece (MOQ)
Pressure : Up to 25 bar max (depending on model)
Feature : Brass connections
WR1 Flow Indicator
20 Piece (MOQ)
The WR1 mechanical flow indicator is designed for use with water, oils and air/gases to show a quantitative flow display though a spinning rotor.
Pressure : 16 bar max
Feature : Brass Connections
...moreWO1 Flow Indicator
10 Piece (MOQ)
Details : No moving parts internally Internal wiper provides ability to clean the glass without removing the device. Installation location as desired For heavily soiled or coloured fluids 360o visibility Characteristics : Devices made from solid brass or stainless steel, where the medium can be visually examined through the sight glass (fluid level, colour, bubbles, ...). A wiper makes it possible to clean the sight glass.Options : Wiper seal made from EPDM
...moreVM..E Paddle Flow Switch
20 Piece (MOQ)
Features: High temperature Option Change-over microswitch Optional ATEX Certified Switch-head User adjustable switch-point (Multiply water flow-rates by 15 to obtain flow-rates for air)
...moreVL Flow Switch
100 Piece (MOQ)
Feature : Optionally switching contactCharacteristics : A piston moves in a transparent glass tube, relative to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the flow rate on the scaled glass tube.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet When tightening the union nut, the connection piece must be countered using an open-ended spanner (SW 19). If the media are dirty, install a filter (use magnetic filter for ferritic components). It must be ensured that the values given for voltage, current, and power are not exceeded. When switched on, a load must be connected in series. The electrical details apply to ohmic loads. Capacitive and inductive loads must be operated using a protective circuit. Options : Display and switching ranges for oil or gas Special values Scale 0..100 % Optionally transformer 250 V AC, 1,5 A, 50 VA, Wiring no. 0.282 Ordering information : Specify direction of flow, medium, and switching range. For oils, state viscosity, temperature and designation (e.g. ISO VG 68) (enquire about range). For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (enquire about range).
...moreVHZ Flow Transmitter
50 Piece (MOQ)
Details : Ideally suited for viscous media (oils) Light and compact construction in an aluminium housing For cost-sensitive applications Characteristics : The VHZ gearwheel flow meter measures the flow by a volumetric principle, in which a pair of gearwheels is moved proportional to the flow rate. The movement of the gearwheels is measured through the enclosing housing wall by a sensor. The devices are suitable for viscous, fluid, self-lubricating media, as well as for aqueous fluids such as soaps, pasts, emulsions etc. which have a non-abrasive character. Because of the volumetric functioning principle, the devices are almost completely independent of viscosity. A push-pull transistor output, an A / B output or a two wire output are available as signal output. The push-pull output can as desired be connected as a PNP or an NPN output, and emits a frequency proportional to the flow rate. The A / B output consists of two push-pull outputs, whose signals are phase-shifted by 90 °. This makes it possible to determine the direction of flow using the bidirectionally driven sensor. The 2 wire model represents the pulse as two different currents, and has the advantage of reduced wiring effort. Alternatively, it is possible to use add-on electronics with signal processing, in the series OMNI, FLEX and LABO. Wiring : Before the electrical installation, it must be ensured that the supply voltage complies with the data sheet. The use of shielded cabling is recommended.Handling and OperationInstallation : The VHZ flow measurement device can be installed anywhere in the pipework system. A run-in section is not required. The direction of flow may be freely chosen. It should be ensured that no dirt particles (thread cutting swarf!) can get into the flow space, as this could cause the blockage of the gearwheels. It may therefore be necessary to install filters upstream of the flow measurement device (mesh size 30 μm).Options : Highest temperature 120oCAccessories : Cable/round plug connector (KB...) see additional information “Accessories” Remote flow display OMNI-TA
...moreVD GR-GK Flow Switch
20 Piece (MOQ)
Features: 1/4″ to 3″ BSP threaded connections Exact setting of switch via scale
...moreVD FT Flow Switch
20 Piece (MOQ)
VD Flow Switch
100 Piece (MOQ)
Details : Highly reproducible Insensitive to dirt DIN flange housing Precise setting of the switching valve by means of a 180o scale / setting diagram Characteristics : Mechanical flow switch, for fluid media, with no-contact triggering of an adjustable Reed contact. Robust construction in stainless steel material.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet When tightening the union nut, the connection piece must be countered using an open-ended spanner (SW 19). If the media are dirty, install a filter (use magnetic filter for ferritic components). It must be ensured that the values given for voltage, current, and power are not exceeded. When switched on, a load must be connected in series. The electrical details apply to ohmic loads. Capacitive and inductive loads must be operated using a protective circuit. Options : Signal lamp Temperature display 0..120 oC Temperature monitoring 40..90oC Temperature resistant up to 150 oC Protection class IP 65 Metal cap Germanischer Lloyd (Type VR) Switching ranges for oil or gas Special values Selected hysteresis Rhodium contact (250 VAC, 0,5 A, 30 VA) Ordering information : Specify direction of flow, medium, and switching range. For oils, state viscosity, temperature and designation (e.g. ISO VG 68) (enquire about range). For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (enquire about range).
Ambient Temperature : -20..+70°C
...moreV Bank Filters
20 Piece (MOQ)
The V Bank Filters, offered by us, are extensively quality reviewed before getting dispatched to the market. We understand that the superior quality raw material is essential for manufacturing top-notch products. For this, we have tied-up with the leading names who assure us for the quality. Contact us our customized packaging solutions. Apart from the standard packaging options, we can pack products in wanted amount and stack them accordingly in premium packaging.
...moreUZ Flow Meter
10 Piece (MOQ)
Details : Monitor and display Simple switching point adjustment by means of drag indicator Insensitive to dirt Suitable for media with ferritic particles. Characteristics : With the UZ paddle flow display, the flow strength of the medium presses the paddle against a spring force. Hermetically separated by the bellows, the paddle's deflection is transmitted to a display movement, and may optionally be monitored with an adjustable micro switch. There is no magnet in the area of flow.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet If the media are dirty, install a filter. It must be ensured that the values given for voltage, current, and power are not exceeded. When switched on, a load must be connected in series. The electrical details apply to ohmic loads. Capacitive and inductive loads must be operated using a protective circuit. Adjustment : The micro switch (optional) is adjusted by means of the knurled adjusting screw provided. The screw allows the drag indicator to be set to the desired switching value. The value displayed corresponds to a switching point for a decreasing flow rate.Options : Metering ranges for oil or gas Special values Gold contact : Min - 5 V DC, 1 mA Max - 125 V AC, 30 V DC, 1 A Special Harting plug Ordering information : Specify direction of flow, medium, and metering range. For oils. State viscosity, temperature and designation (e.g. ISO VG 68) (enquire about metering range). For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (request metering range)
Tolerance : ±3 % of full scale value
...moreUR1 - UR2 - G-A Paddle Flow Switch
20 Piece (MOQ)
Features: Low pressure loss Brass , stainless steel or plastic options User adjustable reed-switch ATEX Certified switch-head option
...moreUM3K - GA Paddle Flow Switch
20 Piece (MOQ)
Material : Brass or stainless steel bodies
UM3K Flow Switch
100 Piece (MOQ)
Details : Soldered/welded connection Micro switch Low pressure loss Compact design Threaded connection Plug DIN 43650-A / ISO 4400 Characteristics : The devices function via the principle of a spring-supported paddle, and the magnetic triggering of a micro switch.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet When tightening the union nut, the connection piece must be countered using an open-ended spanner (SW 19). If the media are dirty, install a filter (use magnetic filter for ferritic components). It must be ensured that the values given for voltage, current, and power are not exceeded. When switched on, a load must be connected in series. The electrical details apply to ohmic loads. Capacitive and inductive loads must be operated using a protective circuit. Options : Connection for round plug-in connector Signal lamp red or red/green in the plug DIN 43650-A Gold contact 125 V AC / 30 V DC, 100 mA Protective bellows Switching ranges for oil or gas Special values Adhesive PVC fitting Ordering information : Specify direction of flow, medium, and switching range. For oils, state viscosity, temperature and designation (e.g. ISO VG 68) (enquire about range). For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (enquire about range).
...moreUK-020 Flow Meter
10 Piece (MOQ)
Details : Frontal scale imprint Optionally valve Installation plate Characteristics : A float moves in a transparent conical measurement tube, relative to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the flow rate on the scaled measurement tube.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet If the media are dirty, install a filter Options : Metering ranges and special scales under defined operating pressures / temperatures Seal made of FKM only for brass construction) Ordering information : Specify direction of flow, medium, and display range. For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (request display range)
Weight : 0.13 Kg
Tolerance : ±5 % of full scale value
...moreUB1 Paddle Flow Switch
20 Piece (MOQ)
Features: Mechanical flow switch for liquids or gaseous media. A bellow-supported paddle activates an adjustable micro-switch. Operational range a diameter 25-200 Visual functions control by transparent cover “Combination contact” gold coating for small currents & silver coating for larger currents Low pressure loss
...moreTonson Vane Air Motor
10 Piece (MOQ)
AIR GEARMOTORS (Planetary Reducer) ,V1-FG43 V6-LB(Foot, Brake) V4-LBHV ,V6-FB(Flange, Brake), V8-FBRCV (Flange, Brake, Remote Control Valve)SERIES- V1 1AM,VA1 1UP,V2 2AM,V4 4AM,V6 6AM,V8 8AM V16 16AM V1-F,V1-L,VA1-F,VA1-L, V2-F,V2-L,V2-B,V2-N,V2-I V4-F,V4-L,V4-LM,V4-M,V4-B,V4-N,V4-I V6-F,V6-L,V6-B,V6-N,V6-I,V6S-I, V8-F,V8-L,V8-B,V8-N,V8-I, V16-F,V16-L,V16- LN,V16-N,V16-I, V1-FG3.5, V1-FG15
Country of Origin : India
Type : Air Vane Motor
Application : Industrial Usage
Color : Grey, Light Green
Feature : Premium Quality, Rust Proof
...moreTonson Piston Air Motor
10 Piece (MOQ)
SERIES- M13S,M14,M15,M16,M17,M18,M13S-F,M13S-L,M13S-I,M13S-N,M14-F,M14-L,M14-I,M14-N,M15-F,M15-L,M15-I,M15-N,M16-F,M16-L,M16-I,M16-N,M17-F,M17-L,M17-I,M17-N,M18-F,M18-L,M18-I,M18-N,SERIES- M13S,M14,M15,M16,M17,M18,M13S-F,M13S-L,M13S-I,M13S-N,M14-F,M14-L,M14-I,M14-N,M15-F,M15-L,M15-I,M15-N,M16-F,M16-L,M16-I,M16-N,M17-F,M17-L,M17-I,M17-N,M18-F,M18-L,M18-I,M18-N,SERIES- M13S,M14,M15,M16,M17,M18,M13S-F,M13S-L,M13S-I,M13S-N,M14-F,M14-L,M14-I,M14-N,M15-F,M15-L,M15-I,M15-N,M16-F,M16-L,M16-I,M16-N, M17-F,M17-L,M17-I,M17-N,M18-F,M18-L,M18-I,M18-N
Country of Origin : India
Type : Air Motor
Material : Metal
Color : Grey
Feature : Easy To Fit, Premium Quality
Driven Type : Electric
...moreTemperature Measuring Device
20 Piece (MOQ)
GMH 3511 Product-ID 604953pH / ORP / temp. measuring device w/o accessoriesGMH 3531 Product-ID 602076pH / ORP / temp. measuring device w/o accessoriesGMH 3551 Product-ID 602817pH / ORP / temperature measuring device with datalogger w/o accessories Automatic temperature compensation In operation mode „pH“ an automatic tempera turecompensation (ATC) is possible in the range 0 ... 105 °C if a temperature probe is connected. Otherwise a manual input of temperature is possible. pH calibration Buffer selection, temperature compensation and sensorrating a ccording to calibration result (from 10 ... 100 %) is done automatically. GMH 3511 2-point calibration with Greisinger buffer capsules (GPH 4, 7, 10) GMH 3531, GMH 3551 Either 1-, 2- of 3- point calibration with Greisinger standard buffer, buffer according to DIN19266 (A, C, D, F, G) or manual buffer selection. Calibration interval (not for GMH 3511) The device asks for a recalibration after a selectable time period (1 - 365 days or inactive) GMH 3551 Calibration history additional ORP measurement (Redox) There are 2 choices „mV“ standard ORP or mV measurement „mVH“ temp. compensated conversion to hydrogen system acc. to DIN38404 part 6, table 1 based on the standard ORP electrode (e.g. GE105 with Ag/AgCl system and 3 mol KCl) used. rH measurement (except GHM 3511) Calculation of the rH value by means of a ORP measurement and by manually entering the pH-value. The pH-value may also be taken from a previous pH measurement. Analog output 0 ... 1 V, not changeable 0 ... 1 V = 0 ... 14 pH or -2000 ... 2000 mV, connection via 3-pole jack socket Ø 3.5 mm, resolution 13 bit, accuracy 0.05 % at nominal temperature GMH 3551 Analog output freely scalable data logger (GMH 3551 only) cyclic 10,000 data sets, manual 1,000 data sets (with measuring point input, 40 adjustable measuring point texts or measuring point numbers).
Application : For Measuring Temperature
Power : 9 V battery, additional socket for external 10.5-12 V direct current power supply
...moreSS Custom Level Switch
20 Piece (MOQ)
Features: 1 to 6 switch points Up to 5m length. Choice of Threads Terminal head, Flying Leads, DIN connector Options. Various Floats Available ATEX Options Available
...moreServo Drive
20 Piece (MOQ)
Features: Mitsubishi D700 1 - Phase Servo Drive 3 HP Lexium 23 Schneider Servo Drive, Single Phase, Digital Mitsubishi AC Servo Drives, Model Name/Number: E700, Single Phase
...moreS Atex Custom Level Switch
20 Piece (MOQ)
Features: 1 to 6 switch points Up to 5m length. Choice of Threads Terminal head, Flying Leads, DIN connector Options. Various Floats Available ATEX Options Available
...moreRVM Flow Switch
10 Piece (MOQ)
Details : Monitoring of small flows PN 300 / 350 Characteristics : Mechanical flow switch, for fluid media, with magnetic triggering of a reed switch. Robust construction in brass or stainless steel.Handling and operation : Include straight calming section of 5 x DN in inlet and outlet. If the media are dirty, install a filter (use magnetic filter for ferritic components). It must be ensured that the values given for voltage, current, and power are not exceeded. When switch on, a load must be connected in series. The electrical details apply to ohmic loads. Capacitive, inductive and lamp loads must be operated using a protective circuit. Options : Switching values for oil or gas Special values Switch contact as changeover Ordering information : Specify direction of flow, medium, and switching range. For gases, state pressure (relative or absolute), temperature and medium (e.g. air) (request switching range).
...moreRT-AK Flow Transmitter
50 Piece (MOQ)
Details : High precision No magnetic components in the flow space High pressure resistance Characteristics : A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of a biased Hall sensors, i.e. there are no magnets in the flow space. Handling and Operation :Installation : As with all flow meters, if possible the turbine should be installed ahead of a valve (on the pressure side). Good degassing should be ensured. 10 x D calming sections are recommended before and after the turbine in order to maintain the specified accuracies. The turbine should be filled with fluid at all times. The electronics housing does not project into the flow space.Options : Flanged model, max. temperature 150oC DN 80-300 PN 16 model for air / gas range from 0.05 m³/h Accessories : Cable/round plug connector (KB...) see additional information “Accessories” OMNI-TA
...moreOpening Hours