Endee Engineers Pvt. Ltd. Saki Vihar, Mumbai, Maharashtra

  • WEATHER PROOF WP-GAS-TRANSMITTERS

    WEATHER PROOF WP-GAS-TRANSMITTERS

    Request for Price

    Relay contacts could be typically used to actuate remote alarms, increase ventilation, shut off gas supply, or shut down a process. Should it not be feasible to install the sensor at the desired location because of maintenance, or operational consideration, a suction based sampling system can be employed. The Sensors Detectors are of very sturdy construction, with weather proof or ex-proof housings and are designed to serve for several years under normal Operating Conditions.

    ...more
    Get Best Price
  • WATER-IN-OIL-METER

    WATER-IN-OIL-METER

    Request for Price

    Air or Gas samples up to 12kg/cm² pressure and temperature up to 75°C can be directly measured. For higher temperature applications, a Heat sink tubing can be used. The meter can also be connected to a vacuum pump for sampling from systems at low or atmospheric pressure. AMM 60 Measures the dew point precisely by utilizing a highly reliable microprocessor based electronic circuit to convert the sensor signal by the use of psychometrics equations. Assembled in a ABS plastic housing, It has inbuilt sensor manifold with an orifice that means line pressure for true pressure dew point readings. Endee Model AMM-60 Dew Point Meter, a portable instrument is designed to measure the performance of compressed air and process drying systems. It is ideal for Moisture monitoring in commercial and industrial applications. Periodic monitoring of industrial Air systems results in a reduced maintenance cost & down time caused by condensate, the leading cause of corrosion in pneumatic systems. Handy and Light Weight Instant Direct dew point reading Digital Display Over all range - 60° C TO + 30°C Samples Pressure Upto 12 Kg/C2M Inbuilt Thin film water vapour sensor Optional RS 232 Computer Interface & Data Logger

    ...more
    Get Best Price
  • VOC-GAS-MONITOR

    VOC-GAS-MONITOR

    Request for Price

    This micro controller based intellegent Detector is highly sensitive to VOC and solvent vapor. The LCD displays the level of gas or the vapors present. An audible alarm alerts you of dangerous levels with response in seconds. On start-up, it goes through self integrity check before getting into measurement mode. Complete Automatic Operation Self Diagnostic Check Backlit Alphanumeric Display Diffusion or Suction Sampling Audio & Visual Battery Alarms Simultaneous Display of Gas Name And Concentration Intrinsically Safe

    ...more
    Get Best Price
  • UV-IR-test-Lamp

    UV-IR-test-Lamp

    Request for Price

    Factors that affect the distance used Maker of flame detector & window contamination • Power charging status of test lamp in use.• For usage from far distance, turn the test lamp toward the center of a detector. • Cleanness of front window of test lamp(Keep it clean all the time) Turn the test lamp toward a flame detector. Press operation switch('ON') Blinks repeatedly after 30 seconds, 10 seconds is not flashing Direct the brightest part of light toward detecting part. wait for flame detector operation. Typically, a flame detector LED is turned on continously after blinking when they are detecting. If a flame detector does not work properly, repeat above 1-4 process with closer access to a flame detector. Press operation switch('OFF') Cover range and test time depend on makers of detectors. Usually 5 sec. waiting time within 2M. Charge after using.

    ...more
    Get Best Price
  • UV IR TEST LAMP

    UV IR TEST LAMP

    Request for Price

    Turn the test lamp toward a flame detector. Press operation switch('ON') Blinks repeatedly after 30 seconds, 10 seconds is not flashing Direct the brightest part of light toward detecting part. wait for flame detector operation. Typically, a flame detector LED is turned on continously after blinking when they are detecting. If a flame detector does not work properly, repeat above 1-4 process with closer access to a flame detector. Press operation switch('OFF') Cover range and test time depend on makers of detectors. Usually 5 sec. waiting time within 2M. Charge after using. Factors that affect the distance used Maker of flame detector & window contamination • Power charging status of test lamp in use.• For usage from far distance, turn the test lamp toward the center of a detector. • Cleanness of front window of test lamp(Keep it clean all the time)

    ...more
    Get Best Price
  • UV IR FLAME DETECTORS

    UV IR FLAME DETECTORS

    Request for Price

    UV-IR Flame Detector is a combination of a UV andIR flame detector which utilizes a microprocessor for sophisticated electronic signal analysis. When a UV optical sensor is integrated with an IR sensor, a dual band detector is created that is sensitive to the UV and IR radiation emitted by a flame. The combined UV-IR flame detector offers increased immunity over the UV detector, operates at moderate speeds of response, and is suited for both indoor and outdoor use.  Highly Sensitive - detects cigarette lighter flame from 5 meters. Flame detection exceeding 50 meters. Scans an area instead of spot detection. Fast Response Time. Solar and artificial light blindness. Rugged electronic, module. Weather Proof / Explosion proof housing. Design for used in hazarduous /non hazarduous locations. Low power consumption 12/24 VOC or 220 VAC Operation

    ...more
    Get Best Price
  • UV-FLAME-DETECTOR

    UV-FLAME-DETECTOR

    Request for Price

    Highly Sensitive - detects cigarette lighter flame from 5 meters. Flame detection exceeding 50 meters. Scans an area instead of spot detection. Fast Response Time. Solar and artificial light blindness. Rugged electronic, module. Weather Proof / Explosion proof housing. Design for used in hazarduous /non hazarduous locations. Low power consumption 12/24 VOC or 220 VAC Operation

    ...more
    Get Best Price
  • Uv Flame Detector

    Uv Flame Detector

    Request for Price

    A highly sensitive instrument to detect flames electric spark, tire in environments where catastrophic consequences could result from unwanted fire. It is particularly suitable for use in outdoor applications because it is not affected by wind or rain and is insensitive to solar radiation. Various models to detect

    ...more
    Get Best Price
  • UV BURNER CONTROL

    UV BURNER CONTROL

    Request for Price

    Endee UV Flame Sensor uses very sensitive electronic UV tube. The specially tuned UV tube is designed to detect UV radiations emitted by the naked flame. The UV Flame Sensor is insensitive to normal light and refractory glow in furnace walls. UV Sensor is ideally suited for detecting all types of flame, namely flames due to Gas / Coal / Oil fired burners in Boiler and Furnaces. UV Sensor ( Model UV - 01 -AJ) has been specially designed for harsh industrial environment. It provides for easy cleaning of the UV Sensor and viewing of the flame. UV Flame sensor is housed in a metal jacket to provide mechanical protection and various mounting features UV Flame Amplifier / Relay (Model UV - FR - 01) is used in conjunction with UV Flame Sensor to detect various types of flames namely gas, oil, coal etc The UV Flame Amplifier is essentially a stand alone unit, which has Two Potential Free relay contact outputs rated at 220 V AC, 4 Amps. The out put contacts can be used for alarm, annunciation or trip purposes. The front panel has indications for SUPPLY ON. This will turn ON when the supply is given. RELAY ON indicator confairms presence of UV radiation / flame. Model UV - FR - 21, has a site adjustable time delay of 2 - 8 seconds and is useful for installations with high flicker situation. UV Flame Amplifiers / Relay has been designed to work with Endee make UV Sensor UV - 01. However, it work satisfactorily with UV Sensors rated 220 V AC.rms of various other makes.

    ...more
    Get Best Price
  • UV-BURNER-CONTROL

    UV-BURNER-CONTROL

    Request for Price

    The out put contacts can be used for alarm, annunciation or trip purposes. The front panel has indications for SUPPLY ON. This will turn ON when the supply is given. RELAY ON indicator confairms presence of UV radiation / flame. Model UV - FR - 21, has a site adjustable time delay of 2 - 8 seconds and is useful for installations with high flicker situation. UV Flame Amplifiers / Relay has been designed to work with Endee make UV Sensor UV - 01. However, it work satisfactorily with UV Sensors rated 220 V AC.rms of various other makes.   Endee UV Flame Sensor uses very sensitive electronic UV tube. The specially tuned UV tube is designed to detect UV radiations emitted by the naked flame. The UV Flame Sensor is insensitive to normal light and refractory glow in furnace walls. UV Sensor is ideally suited for detecting all types of flame, namely flames due to Gas / Coal / Oil fired burners in Boiler and Furnaces. UV Sensor ( Model UV - 01 -AJ) has been specially designed for harsh industrial environment. It provides for easy cleaning of the UV Sensor and viewing of the flame. UV Flame sensor is housed in a metal jacket to provide mechanical protection and various mounting features UV Flame Amplifier / Relay (Model UV - FR - 01) is used in conjunction with UV Flame Sensor to detect various types of flames namely gas, oil, coal etc The UV Flame Amplifier is essentially a stand alone unit, which has Two Potential Free relay contact outputs rated at 220 V AC, 4 Amps.

    ...more
    Get Best Price
  • UNIVERSAL-MULTI-GAS-MONITOR

    UNIVERSAL-MULTI-GAS-MONITOR

    Request for Price

    Continuous Multi Gas Monitoring Complete Automatic Operation. Self Diagnostic Check. Diffusion or Suction Sampling. Backlit Alpha numeric Display. Audio and Visual Alarm. Simultaneous Display of Gas name and Concentration Audible Alarm / Low Battery Warning Buzzer Intrinsically Safe No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4X1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitoring While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling. Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.

    ...more
    Get Best Price
  • Turbine Generators

    Turbine Generators

    Request for Price

    The Model 7001 is a Rugged, Portable, Easy-to-use Gas Analyser that monitors purge gases and the cooling gas in hydrogen-cooled turbine generators. It measures hydrogen in air & hydrogen in C02 as well as C02 in air during maintenance purging of hydrogen rooted turbine generators. Switch selectable ranges on the instrument make it easytochoosethe measurement required.

    ...more
    Get Best Price
  • Trace Moisture Analyzer

    Trace Moisture Analyzer

    Request for Price

    Designed to make the task of trace oxygen analysis easier, faster and more precise than ever before Insta recovery advanced micro fuel cell sensor Display gas concentration, units Extensive self-diagnostic testing at start-up and on demand with continuous powersupply monitoring Auto ranging capabilities One high and one low alarm set point with corresponding relay contacts Sensor failure alarm Extended-life, maintenance-free sensor.one year warranty and an expected life of two years 16x2-line alphanumeric display screen, continuously prompting and informing the operator High resolution, accurate readings of oxygen content from low ppm levels through 25%.

    ...more
    Get Best Price
  • SF6-LEAK-DETECTORS

    SF6-LEAK-DETECTORS

    Request for Price

    Endee is proud to present this tool from Dilo as the most stable and sensitive negative corona SF6 leak detector ever made. An advanced microprocessor is the heart of this unit. Its Digital Signal Processing permits better management of the circuitry and sensing tip signal than ever before possible. Microprocessor Controlled with Advanced. Digital Signal Processing Tricolor Visual LED & Audio Signal for Leak Indication. Seven Level of Sensitivity. Tactile Keypad Controls Battery Test Function. Battery Voltage Level Indication. Cordless and Portable Comfortable One Hand Operation. Additionally, the number of components used in the circuit is reduced nearly 40%,increasing reliability and performance when searching for SV^ leaks. The microprocessor monitors the sensing tip and battery voltage levels 2000 times per second, compensating for even the most minor fluctuations in signal. This translates into a stable and depend-able tool in almost any environment. Convenience features have been added to enhance the usability of the 3-033-R002. Seven levels of sensitivity provide an increase of 64 times from level 1 to level 7. Unique Tri-Color LED's show a progressive and wide ranging leak size indication, communicate the sensitivity level, and provide a true voltage indication of battery power level. A tactile keypad controls all functions of operation. A revolutionary new case design gives the user grip and control, and places the visual indicators in direct sight during use

    Warranty : One year

    ...more
    Get Best Price
  • SAMPLE-CONDITIONING-SYSTEM

    SAMPLE-CONDITIONING-SYSTEM

    Request for Price

    Custom designed sample conditioning system Application specific principle of Analysis Infrared & Electrochemical detector for CO and C02 & NOx, HC. Electrochemical/paramagnetic or zirconia detector for 0 Hydrocarbons & Hydrogen Heated stack mounted filter optional Automatic calibration Built in printer. (Optional) Multipoint sampling system. (Optional) RS-232/485 output for data. logging and further analysis.(Optional)

    ...more
    Get Best Price
  • RELATIVE HUMIDITY TRANSMITTERS

    RELATIVE HUMIDITY TRANSMITTERS

    Request for Price

    Endee Model RHT 98 Relative Humidity Transmitter are Precision instrument designed for monitoring Relative Humidity or Moisture in rugged industrial application and environment. Direct Digital Relative Humidity Readout. 0-100% RH Range. Highly Sensitive & Accurate. Long Life CMOS IC Sensor. Maintenance Free Washable Sensor. One Point Field Calibration. Optimised Over the -40 deg.C to +80 deg.C. No Separate Temp. Monitoring Required. Integral or Remote Mounting Probe. Endee Relative Humidity Controllers are designed for monitoring Relative Humidity in rugged industrial use. They employ advanced digital technology to provide reliable and highly accurate Relative Humidity Measurement with excellent repeatability & linearity range of 0-100% Humidity is optimised over the temperature range of -40deg.C to +80deg.C as such seperate temperature measurement is not required. The well proven Capacitive CMOS IC Sensor offer exceptional resistance to common contaminants like organic vapours. They are washable, don’t require clean environment or a constant supply of moisture or frequent servicing. Incorporating the state of the art design and latest sensing principle these transmitters provide a quick payback through significant reduction in maintenance costs and providing accuracies that direct contribute to the quality of the product.

    ...more
    Get Best Price
  • RACE-MOISTURE-ANALYZER

    RACE-MOISTURE-ANALYZER

    Request for Price

    Custom Engineering is Endee's main strength Endee maintains in-house capability to both design and manufacture a wide variety of sample systems tailored to meet out customers' process requirements. We design sample-conditioning systems for our complete line of process analyzers .The trace oxygen analyser can be ordered as a standard unit or as part of a larger cost effective integerated analytical system. The analyser can also be supplied designed as a “split architecture” instrument, meaning that a general purpose, panel mounted Control Unit for non-hazardous areas controls a remote Analysis Unit(Transmitter) that can operate in hazardous areas. Designed to make the task of trace oxygen analysis easier, faster and more precise than ever before Insta recovery advanced micro fuel cell sensor Display gas concentration, units Extensive self-diagnostic testing at start-up and on demand with continuous powersupply monitoring Auto ranging capabilities One high and one low alarm set point with corresponding relay contacts Sensor failure alarm Extended-life, maintenance-free sensor.one year warranty and an expected life of two years 16x2-line alphanumeric display screen, continuously prompting and informing the operator High resolution, accurate readings of oxygen content from low ppm levels through 25%.

    ...more
    Get Best Price
  • PROCESS-GAS-ANALYZER

    PROCESS-GAS-ANALYZER

    Request for Price

    The Model CA 2000 Series Multi Gas Analyser Is Suitable For The Continuous Measurement Of The Concentrations Of Gases Such As CO, C02, S02, NO, 02, CH4, H2. Maximum Four Of These Components Can Be Measured In The Analyser The Simplicity Of Operation Makes Endee Gas Analyser A Valuable Aid For Continuous Use In Various Applications Changing The Measuring Parameters. It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific of Gases to Be Measured. Needs of Customer in Selection Optionally Lndee Ca 2000 Is Available With Highly Up-Gradable Microprocessor Based Llectronics Which Is Lquipped Willi Ballery Backup For Ram To Retain The Existing SeL Modes In Case Of Power Failure. Any Unacceptable Deviation From The Standard Stored Values Is Displayed As An Indication "Fault", Alarms for Low & High and Specific Fault Specific Sensor as Per the Measuring Gas, Range & Application Sample Conditioning System Offered As Per Application Complete Automatic Operation 16 Characters; 2 Line LCD Display Messages Self Diagnostic Check Facility A Mere Six Key to Operate the Complete Instrument  

    ...more
    Get Best Price
  • Portable-Gas-Monitors

    Portable-Gas-Monitors

    Request for Price

    Compact, Light Weight Intelligent Unit with Application Specific Sensors Sensitive to PPB / PPM Or % i age levels of Gases & Vapors.The advanced Micro controller technology employed makes these ALERT METERS highly dependable, reliable and accurate. The complete automatic operation and calibration feature leaves no Complete Automatic Operation Self Diagnostic Check Backlit Alphanumeric Display Diffusion or Suction Sampling Audio & Visual Battery Alarms Simultaneous Display of Gas Name And Concentration Intrinsically Safe

    ...more
    Get Best Price
  • PORTABLE GAS MONITORS

    PORTABLE GAS MONITORS

    Request for Price

    Compact, Light Weight Intelligent Unit with Application Specific Sensors Sensitive to PPB / PPM Or %V/V levels of Gases & Vapors.The advanced Micro controller technology employed makes these ALERT METERS highly dependable, reliable and accurate. The complete automatic operation and calibration feature leaves no Complete Automatic Operation Self Diagnostic Check Backlit Alphanumeric Display Diffusion or Suction Sampling Audio & Visual Battery Alarms Simultaneous Display of Gas Name And Concentration Intrinsically Safe No Scope for user error These Compact, self contained and intrinsically safe designed instrument housed in a weather proof high impact plastic case are powered with a replaceable 4 X 1.2V Dc battery. On switching 'ON', the instrument goes thorough its complete self integrity check, and displays factory set Warn and Alarm values before indicating 'Ready' for monitori ng While in Operation, the instrument monitors the work place continuously giving the latest update concentration of designated Gas through diffusion sampling. Suction sampling is possible with an optional manual or battery operated pump and adaptor. The poison resistant Pellister or long life, integrally mounted electrochemical Sensors with inbuilt cross interference filters are gas specific. Optionally the sensors can be mounted on an extension cable for monitoring inaccessible locations before entry. The instruments emits an audible beep every 15 sees that provides confidence to the user that he is well protected. Audio, Visual also Warn and Alarms protect him from hazardous situations.

    ...more
    Get Best Price
  • PORTABLE GAS-ANALYZER

    PORTABLE GAS-ANALYZER

    Request for Price

    Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory. Complete Automatic Operation Self Diagnostic Check Applications specific Sensor Technology. Continuous Stable Alphanumeric display Long Life Rechargeable Batteries Data logging and 232 Output Capability On Start up, the intrument goes through complete Self Integrity, Check Calibration Check on Demand. Digitally Displays the result Instantly.

    ...more
    Get Best Price
  • Portable Gas Analyzer

    Portable Gas Analyzer

    Request for Price

    Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on-site instant analysis and follow up action. Its data logging & in the computer interface facility can be used for further detailed analysis at laboratory.

    Weight : 390Gm (with battery)

    ...more
    Get Best Price
  • PORTABLE FUEL-GAS-ANALYZER

    PORTABLE FUEL-GAS-ANALYZER

    Request for Price

    Sturdy stainless steel sampling probe with extension tubing for ease of measurement. Thermocouple in the tip of probe measures temperature at point of sampling to minimise error. Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure. Inline Filter to Inbuilt Moisture & Dust, Disposable easy to replace filter element. Supervisory Diagnostic circuit continuously checks it against choking. Retains the readings till the next sampling. Compact Aluminum Housing Rechargeable Ni-cad battery pack with charger. Maintenance & Spare Parts : Designed for free maintenance operation. Long Life Sensor. Combustion efficiency is determined by Oxygen content and temperature of Fuel gases. An excess air (Oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (Oxygen) produces an incomplete i combustion with consequent higher costs and increased polluting emissions. Long life zirconium sensor Very fast response, no purgetime No reference gas required High accuracy Wide measurement range 1 ppm to 96% Simpletooperate Maintenance free automatic & begins with every start up with fresh air aspirated instead of Gas sample.. Automatic self check for efficiency calculation :With aspirated fresh air specific percentage efficiency of the selertpd Fuel is displayed as a cherk nn its calculations. Self Supervisory Diagnosis : Continuously checks the status of: 1) Battery Voltage 2) Sample Flow 3) Oxygen Sensor

    ...more
    Get Best Price
  • Portable Flue Gas Analyzer

    Portable Flue Gas Analyzer

    75,000 - 105,000 Per Piece

    We are offering portable flue gas analyzer. sturdy stainless steel sampling probe with extension tubing for ease of measurement. Thermocouple in the tip of probe measures temperature at point of sampling to minimize error. Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure. Inline filter to inbuilt moisture & dust, disposable easy to replace filter element. Supervisory diagnostic circuit continuously checks it against choking. Retains the readings till the next sampling. Compact aluminum housing rechargeable ni-cad battery pack with charger. Maintenance & spare parts : designed for free maintenance operation. Long life sensor. Combustion efficiency is determined by oxygen content and temperature of fuel gases. An excess air (oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (oxygen) produces an incomplete I combustion with consequent higher costs and increased polluting emissions.  

    Driven Type : Battery

    Automation Grade : Manual

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers
  • Year of Establishment 1982
  • No. of Employees 50 - 100
  • Annual Turnover Rs. 0.5 to 2.5 Crore Approx.

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Endee Engineers Pvt. Ltd. from Mumbai, Maharashtra Established in 1982 is Retailer of Leak Detector, Alert Gas Monitor, Ultrasonic Leak Detector, Portable Flue Gas Analyzer, Stack Guard Particulate Monitor, pH Meter, Broken Filter Bag Detector, Wireless Systems, Calibration Cylinders, Portable Hygrometer.
Read More »

Contact Information

Endee Engineers Pvt. Ltd.

  • Mr.. Munnu Lal
  • D/122,Ansa Industrial Estate Saki Vihar Road, Mumbai - 400072., Maharashtra

Find Popular Fixed Gas Monitor Dealers

top