fire safety alarm
Get Price Quote
1 Piece (MOQ)
Fire Alarm System
Get Price Quote
The Fire Alarm System, provided by us, is acclaimed for its work efficiency. We make use of the finest grade raw material that reflects in the finished products. Also, we make sure that it is procured from the trusted places only. Owing to our wide distribution network and speedy delivery services, buyers can receive their orders on timely basis.
Best Deals from Fire Alarm System
Fire Alarm System
Get Price Quote
We have a wide range fire safety and detection products.
fire alarm siren
Get Price Quote
Audible Alarm Signals Audible fire alarm signals must provide a clear warning of a fire to all those for whom the signal is intended. For category M an L systems this would normally imply all occupants of a building, however in some sites this may not apply, for example in hospitals or rest homes, residents might need assistance to evacuate, in which case it may be sufficient to alert staff.The general requirement for the volume of audible alarm signals is that they should provide a Sound Pressure Level (SPL) of at least 65dB(A), but not more than 120dB(A) throughout all accessible areas of building.Exceptions to this general rule are as follows:In stairways the SPL may be reduced to 60dB(A)Enclosures less than 60m² may be reduced to 60dB(A)There is no minimum for enclosed areas less than 1 m²At specific points of limited extent the SPL may be reduced to 60dB(A)Where a continuous background noise level greater the 60dB(A) is present the fire alarm signal should be 5dB above the ambient, but not greater than 120dB(A).Where the alarm is intended to wake people, an SPL of 75dB(A) is required at the bed head. Generally this will require a sounder to be place within the room.Where it is not possible to place a sounder within a room, there will be a loss of approximately 20dB(A) through a standard door, and 30dB(A) through a fire door.Warning: Volumes greater than 120dB(A) will cause damage to hearing.In Open Space, as the distance from a sounder doubles, the sound level will be reduced by 6dB(A).It is Preferable to use multiple quieter sounders to achieve the required sound level, rather than a smaller number of loud devices. This is to prevent points of excessive volume, which may lead to disorientation or damage to hearing. Two sounder providing equal sound levels will combine to add 3dB(A) to the SPL.Visual alarms are required in order to satisfy the Disability Discrimination Act (DDA) as well as being used in areas of high background noise where hearing protection is likely to be worn. Just as audible alarms should be placed through all accessible areas of a building, visual alarms should be placed such that they can be seen in order to alert the hearing impaired.Visual alarms should be clearly distinguishable from other warning lights, preferably red and should flash at a rate of 30 to 130 flashes per minute. The recommended mounting height is above 2.1m; however they should not be mounted closer than 150mm from the ceiling. They should be positioned so that any alarm is clearly visible from all locations within the area protected.
Heat Detector
950 Per Piece
Fire Alarm System
Get Price Quote
Fire Alarm System
Get Price Quote
With the support of our highly knowledgeable and skilled team of professionals, we offer Fire Alarm System. These Fire Alarm Systems are precisely designed to raise alarm in case of fire accident. The Fire Alarm System is used in various commercial and residential areas to alarm and evacuate people in case of any accidental fires and other calamities.Features : High efficiency Strong sensor Reliability
Fire Alarm System
Get Price Quote
We are offering Fire Alarm System to our esteemed customers. As a well-known Supplier of Fire Alarm System from Uttar Pradesh, India, we are committed for providing the buyers with a high-quality product. Hence, our professionals keep an eye on the Alarm System from the time of initial procurement till the final delivery. Customers can rely on us for prompt delivery of Fire Alarm System throughout the country.
Fire Alarm System
Get Price Quote
FIRE ALARM SYSTEM Fire alarm control panel (Conventional & Addressable) Beam detector Control /monitor modules (Interface Module) Smoke detector Manuel call point Fire proof cable etc. Heat detector
Manual Alarm Call Points
Get Price Quote
We are offering the manual alarm call points, offered by us, are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised. There are options for the inclusion of led status indicators and addressable location (or address) within the manual alarm call points. Our manual alarm call points are designed to meet european or north american industrial and fire application standards..
Fire Alarm Systems
Get Price Quote
Akshar Technologies are known to provide fire alarm systems integrated to protect unique critical environments that involve potential risks of a fire breakout. We have a wide range of control panels, early smoke detection system, displays and operating units, wireless and automatic detectors that receive threat messages and provide alarm output to hooters. We collaborate with manufacturer of innovative industrial solutions for applications ranging from fire detection to industrial warning and mass notification systems that serve many Fortune 500 companies around the world. With meticulously designed safety systems for fire warnings, we ensure that a signal can operate properly and effectively in any environment by calculating decibel levels or choosing one light source over another and delivers flexible, reliable, cost-effective and highly scalable systems for fire hazard notifications.
D Fire Manual Call Point
Get Price Quote
Fire Monitoring Alarm System
9,400 Per Piece
Heat Detector
Get Price Quote
Fire Alarm System
Get Price Quote
Fire is one thing that needs no efforts to break and engulfs everything that is around. This is the situation that has many helping hands; be it gas cylinders in-house, or inflammable gasses in Industries. So, to keep safe the personal and professional assets, the only thing one can do is get Fire alarm system installed. The system has an inbuilt alarm that buzz when the control panel of the system senses the smoke or heat. The heat sensing and smoke sensing is done by the sensors that are fitted in. the system is more of a conventional system that helps in detecting the fire break.
UV Currency Detector
Get Price Quote
Heat Detector
2,000 Per Piece
Heat Detectors
Get Price Quote
Heat Detectors, Smoke Detectors
fire security systems
Get Price Quote
fire security systems, Fire Alarm, x ray scanners
Fire Alarm Systems
Get Price Quote
Fire Alarm Systems, Fire Extinguishers, Video Door Phones
fire protection alarm
Get Price Quote
fire protection alarm, cctv camera cable, Dvr, Ip Camera, Hd Cctv Camera
Fire Alarm
Get Price Quote
Fire Alarm, Mcb Box
fire detection systems
Get Price Quote
fire detection systems
Fire Alarm
Get Price Quote
Fire Alarm, biometric access machine, Video Door Phones, motion detector
Fire Alarm
Get Price Quote
Fire Alarm, Fire Fighting Equipment, fire fittings, Nozzles
commercial fire alarm system
Get Price Quote
commercial fire alarm system, Commercial Fire Extinguishers
Morley Fire Alarm Systems
Get Price Quote
Morley Fire Alarm Systems, Lcd Module
Fire Detector Sensor
Get Price Quote
Fire Detector Sensor, Ip Camera, networking solution, CCTV Camera Dealaers
Fire Alarm
Get Price Quote
Fire Alarm, cargo scanners, Video Door Phones, intruder alarm, CCTV System
Fire Detection System
Get Price Quote
Fire Detection System, electronic security systems