Rajshi Engineers Khailar, Jhansi, Uttar Pradesh

  • WIRED PRESSURE ALARM SYSTEM

    WIRED PRESSURE ALARM SYSTEM

    Request for Price

    Application:- To give Alarm and Light Indication if the pressure of Tank reaches to alarming low / high level during transit or storage of Tank / Transformer. Working:- Specially calibrated pressure sensing device is attached to the Tank through Flexible hose, connected to pressure Tank. As soon as the pressure in the tank decreases/increases to alarming level the sensing device actuates the signals. Features:- Complete unit has been packed in FRP Box having tested for Environmental Condition IP65.  Dual Akarm system provided. Wireless / Wired. Any one can be used at a time. Under Ideal Condition workable range of Wireless System is 20-25 Mr. Special ringing effect is incorporated in the ringing wireless system, till the pressure is not restored in the Tank. To check the healthiness of the circuit, CIRCUIT CHECKING SWITCH ( Push Type) is provided. To be used when Tank Pressure is above alarm actuating pressure. 3 Way switch is provided for selection of different use mode TRANSIT / OFF / AUXILLARY. Power source for Remote is Long Life 1 Nos. is Dry Alkaline Batteries 12 V – 23 A, Wireless Buzzer/Bell Long Life Dry Alkaline Batteries AAA  1.5 V. Power source during AUXILLARY (STORAGE) preferred is 12 V- D.C.

    ...more
    Get Best Price
  • Threaded Pressure Relief Valve

    Threaded Pressure Relief Valve

    Request for Price

    Pressure Relief Valve (P.R.V.) is a safety device to be used in Power Transformer/ Rectifiers/Special Transformers, O.L.T.C. , Pressure Tanks & Pressure Lines for indoor & outdoor application. Suitable for  repeated operation than the conventional Explosion Vent. Designed so accurately and giving optimum release instantaneously by  help of Direct Outward Technique (DOT)  the PRV work very accurately & effectively. For Instrument (CT/PT) Transformer/ Distribution/ Power Transformer/ Tanks. Different models are available depending upon :- A) Threaded Mounting size.  ¼” B.S.P.   1/4" N.P.T.  3/8” B.S.P. 3/8" N.P.T. ½”  B.S.P. 1/2" N.P.T. ¾”  B.S.P. 3/4" N.P.T.  1” B.S.P.            O- Other Thread B) Material. Brass Aluminium Stainless Steel. Other. C)  Additional Rain Guard are available as follows:- Without Rain Guard  Plastic Cap ( Rain Guard)  Stainless Steel Cap Screwed  at Top. Stainless Steel Cap Riveted at Top. Stainless Steel Cap with Pulll Ring Top. Other sizes can be manufactured with Metric / American / Other Standard Thread to customer specification.

    ...more
    Get Best Price
  • Rapid Pressure Relief Valve

    Rapid Pressure Relief Valve

    Request for Price

    Rapid Pressure Relief Valve (R.P.R.V.) is a safety device to be used in Power Transformer/ Rectifiers/Special Transformers, OLTC , Pressure Tanks & Pressure Lines for indoor & outdoor application. Suitable for repeated operation than the conventional Explosion Vent. RPRV gives edge our Conventional Pressure Relief Valve (PRV) like. It acts faster than Conventional Pressure Relief Valve. This is very critical at time of sudden pressure rise. It releases pressure quicker than Conventional Pressure Relief Valve.

    ...more
    Get Best Price
  • Pressure Relief Valve

    Pressure Relief Valve

    Request for Price

    Application:- Pressure Relief Valve (P.R.V.) is a safety device to used in Transformer, Pressure Tanks & Lines for indoor & outdoor application. Suitable for repeated operation, than conventional Explosion Vent. Working –                   Port of 150 mm. is sealed by a Stainless Steel Diaphragm resting on an “O” Ring. Heavy- Duty Spring Set keeps the port closed in normal condition. As soon as the pressure exceeds the pre determined safe limit due to any reason like change in temperature, formation of vapor etc. The diaphragm gets lifted from the seat. This exposes the tank pressure to a greater area, corresponding to the diameter of side gasket. Resulting to sudden increase of force. Thus instantaneously opening port of 150mm. and allowing vapor, gas & liquid to flow out of tank. Resulting to fall of pressure. The diaphragm restores its normal position as soon as pressure dropsbelow the set limit and is ready for second jump. Spring retainer prevents the dislocation of spring during repeated operation. The lift of diaphragm also operates the Limit Switch (Double Pole/ Double Throw type) &Visual Indicator (Flag) by help of Rod. Limit Switch is attached with ¾ “* 16 T.P.I.  (B.S.C.) Cable Gland  of PVC.          Engineered for rugged use & long life each P.R.V. is checked for its operational condition individually. It is important to note that depending upon the tank fluid different “O” Ring material is suggested. This design if used in transformer is suitable for operating pressure of 0.42 / 0.49/ 0.56 kg/cm sq. (±0.07 Kg / cm sq.) i.e. 6 / 7 / 8 ± 1 p.s.i. Note: - Our standard feature is PRV with Nitrile Rubber Gasket. Limit Switch confirms to weather protection IP-67 with (1 N.O.+ 1 N.C.) / (2 N.O.+2 N.C.) Contact. Mounting –                    P.R.V. can be mounted both horizontally & vertically by help of 6 mounting holes in Aluminum Casted Body for M12 Bolts at p.c.d. 235mm. Different Models available are Without Electrical Contact & Visual Indicator                              (DP-6) With (Electrical Contact (1 N.O.+1N.C.) & Visual Indicator)        (DP-6EF 1) With (Electrical Contact (2 N.O.+2N.C.) & Visual Indicator)        (DP-6EF 2) These models are also available with VITON Rubber Gasket, suitable for Silicone Oil.  Models are also available with Push Pull Electrical Connection.(1NO.+1NC) / (2NO+2NC).  Vent screw for bleeding air or gas bubbles. PRV at different operating pressure (higher/lower) can be supplied as per your request. Routine Test- is carried on each P.R.V. as follows and test certificate furnished along with supply. Operating Pressure individually. Contact / Operation of Switch & Flag is checked in Before & After Valve Operation condition. Leakage Test at 75% of Operating Pressure for 12 hr is done. Dielectric Test of 2 K.V. for 1 minute. Type Test-                      Our P.R.V. has already qualified Environmental Test IP 67 a must to understand practical adaptability in real life condition and rugged use. Due to our policy of continuous product improvement, dimensions and design are subject to change

    ...more
    Get Best Price
  • Inert Gas Monitor

    Inert Gas Monitor

    Request for Price

    Use in transformers and other sealed Tank while storage / transportation to provide and maintain constant N2 / Inert Gas / Demoisturised Air Pressure so as not to allow atmospheric air inside the chamber / Tank. The atmospheric air is very harmful for content in the tank as contains moisture. Model available are depending upon application or customer use are:- Single/Double/Multiple Cylinders to be connected. Single /Double /Three Stages to reduces the Inlet Pressure as desired. Two/Three/Five Gauges to be fitted. MODELS SGR -02 (Single stage Gas Regulator with Two Gauges) SDGR -02 (Single Body Double stage Gas Regulator with Two Gauges) DGR -02 (Double Body Double stage Gas Regulator with Two Gauges) DGR -05 (Double Body Double stage Gas Regulator with Five Gauges) TDGR -03 (Double Body Three stage Gas Regulator with Three Gauges)             This Model has facility of Cylinder Gas Purging as required) ADD ON AVAILABLE ARE, if required:- Low pressure alarm for tank High pressure alarm for tank Breather Assembly Heater Assembly  MS / SS Cabinet/Frame for Mounting Cylinder. We can also manufacture this equipment as per your design & requirement.

    ...more
    Get Best Price
  • gas filling valve

    gas filling valve

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Rajshi Engineers is Retailer of gas filling valve, Pressure Relief Valve, Inert Gas Monitor, Rapid Pressure Relief Valve, Threaded Pressure Relief Valve, WIRED PRESSURE ALARM SYSTEM from Jhansi, Uttar Pradesh.
Read More »

Contact Information

Rajshi Engineers

  • Mr.. Deepak Lohia
  • 2, BHEL Ancillary Estate, Khailar, Jhansi, Uttar Pradesh
top