Par Techno-Heat Pvt. Ltd. Viramgam Road, Ahmedabad, Gujarat

  • Waste Heat Recovery Steam Generators

    Waste Heat Recovery Steam Generators

    Request for Price

    Get Best Price
  • waste heat boilers

    waste heat boilers

    Request for Price

    We are amongst the leading names in the industry, offering a wide array of Waste Heat Boilers. Our entire product range is thermostatically balanced and is used in varied industrial segments. They cater diverse requirements for heating applications. Our entire product range is abrasion resistant in nature and is delivered as per the requirement.

    ...more
    Get Best Price
  • Tubular Wet Back Packaged Steam Boiler

    Tubular Wet Back Packaged Steam Boiler

    Request for Price

    Get Best Price
  • Steam Power Plant

    Steam Power Plant

    Request for Price

    Get Best Price
  • solid Fuel Fired Hot Air Generator

    solid Fuel Fired Hot Air Generator

    Request for Price

    The vertical four pass Hot Water Generator is suited for various industries across India and abroad in the rapidly changing and undependable energy environment. Thermotech's generous design of vertical heaters coupled with integral furnace gives you an assurance of the rated output on any solid fuels without compromising on performance.Thermotech can deliver sustainable solution to meet your process requirement and thus improve process consistency and reduce downtime leading to further increase inprofitability.

    ...more
    Get Best Price
  • Solid Fuel Boiler

    Solid Fuel Boiler

    Request for Price

    Solid Fuel Boiler is the versatile, fuel efficient specially designed to cater for practically any fuel.It is the perfect combination of unique dependable and manufactured according to the latest standards. This boiler is designed with best in class steel and certified tubes to make sure great life and quality. Its perfect internal water circulation system guarantees increasing the life of the boiler. Apart from all the information, this Solid Fuel IBR Boiler is offered to our customers at market leading rates.

    ...more
    Get Best Price
  • Water Tube FBC Steam Boiler

    Water Tube FBC Steam Boiler

    Request for Price

    4 Pass design, ensures better heat utilisation & ultimate thermal efficiency. Fluidised Bed Combustion furnace ensures very high combustion efficiency, up to 95% even with fuel, having very high ash & fine contents and having very low calorific value. Straight tube in generating bank enables manual cleaning & easy inspection. The rectangular headers are of welded type box headers with individual opening against each tube at both ends of generating bank. Hence, for cleaning & maintenance of any single tube only single door cap, weighing just 1.5 kg has to be opened. Larger tube diameter in generating bank, i.e. 76.2 mm OD, enables easy manual cleaning. Intermediate tube supports in the generating bank, which prevents tube sagging contributes to higher boiler life. Wide gap in tube spacing i e. 160 mm pitch, prevents inter tube space plugging by soot deposition, which permits trouble free operation without external cleaning as clogging of tube space with soot does not take place. Free floating front header takes care of longitudinal thermal expansion. Hence, thermal stresses are not developed during heating. This design enhances boiler life too. Man hole opening at both sides of the drum for easier access to drum internals. Larger diameter drum coupled with drum internal steam separators ensures dry steam even at full main steam valve opening. Moderately larger furnace area and higher free board height, above grate, makes the boiler capable to burn low grade, high volatill3 & ash contained solid fuel efficiently without reducing rated steam generating capacity. No inventory of spares, since nothing special is employed which is necessary to be procured urgently from us or which is not available in the free market.

    ...more
    Get Best Price
  • package boiler

    package boiler

    Request for Price

    Mobile Steam Generator Ex-Stock available :- Oil Gas fired , having Steam Generation Capacity of 25TPH , 25 Bar , 280 Deg.C Super Heated Steam Temp. Truck Trailer mounted Mobile Steam Generators , available from 1TonsHr to 30 TonsHr Capacity. Maximum Steam Pressure available is 105 Kgcm2(g). Option of Supe Heated Steam Available. The World renowned D Type Bi-Drum Water Tube design , which is proven for many years for the RELIABILITY of PERFORMANCE & Sturdiness.

    ...more
    Get Best Price
  • Bi-Drum Water Tube Package Boiler

    Bi-Drum Water Tube Package Boiler

    Request for Price

    Get Best Price
  • Multi Solid Fuel Fired Small Industrial Boiler (SIB)

    Multi Solid Fuel Fired Small Industrial Boiler (SIB)

    Request for Price

    Salient Features: It is designed & manufactured under IBR inspections and dully approved by IBR. It means that the Boiler is guaranteed by a third party for I quality, reliability of performance and its ultimate safety. Even if boiler is IBR approved there is no need to employ 2nd class toile attendant. Only matriculate fellow is eligible to run the boiler. The boiler is required to be offered for open & hydraulic test inspection once in 2 years, to Boiler Inspector.. Boiler is a combination of Smoke Tube & Water Tube technology. Membranes Water wall external furnace makes use of direct radian o heat from furnace. Being an external membranes wall furnace, boiler is very much suitably for fuel like Lignite / Agro waste / Wood etc. With an option of FBC furnace, cheaper fuel like Saw Dust can be used, which is other impossible to be used in hand fired boiler. High thermal efficiency of 75 % ±2 % can be obtained, with hand firing With an option of FBC system with a Micro Processor Based fuel feed - & combustion air pre heater, efficiency unto 87 % +1-2 % can obtained. Though approved by IBR, one can enjoy all freedom of a Non IBR Boil-and still meets the mandatory requirements, pertaining to safety. Pay back period of the new boiler plant, against an Oil fired boiler, is less than 6 Months.,

    ...more
    Get Best Price
  • Vertical Thermic Fluid Heating System

    Vertical Thermic Fluid Heating System

    Request for Price

    Salient Features: 4 Pass Design ensures better heat utilisation & Ash separation. With Fluidised Bed Combustion furnace design, very high Thermal Efficiency of 80%+-2% can be achieved. Automatic Mechanised screw fuel feeding makes fuel feeding OFF & ON when set temperature is achieved & reduced, respectively. Micro Processor Based V/F fuel feed drive is used to adjust the rate of fuel feeding as per Plant load requirement. Most of the Solid Fuels, including Crushed Coal / Lignite / Agro waste / DOC / Saw Dust can be used in this system. Large size Air Pre-Heater / Water ,Pre-Heater, reduces dry flue gas losses and improves the Waste Heat Recovery and increases combustion Air Temperature. Radiant Coils installed directly on FBC Furnace makes maximum utilisation of Furnace radiation heat. Mechanical Dust Collector arrests the fly Ash from Flue gas, before exhausting to Chimney. Ash collection pit is provided below convective coils.

    ...more
    Get Best Price
  • Mobile Steam Generator (MSG)

    Mobile Steam Generator (MSG)

    Request for Price

    Working Pressure : Up to 150 Kg/Sq.Cm.

    Get Best Price
  • Horizontal Steam Boiler

    Horizontal Steam Boiler

    Request for Price

    FBC boilers can be operated efficiently with a variety of fuels. Even fuels like Coal , Husk , agro waste can be burnt efficiently. These can be fed either independently or in combination with coal into the same furnace. Coal containing fines below 6 mm can be burnt efficiently in FBC boiler, which is a very difficult to achieve in conventional firing system. Since the temperature of the furnace is in the range of 750 - 900° C in FBC boilers, even coal of low ash fusion temperature can be burnt without clinker formation. Ash removal is easier as the ash flows like liquid from the combustion chamber. Hence less manpower is required for ash handling.

    ...more
    Get Best Price
  • Gas Fired Boiler

    Gas Fired Boiler

    Request for Price

    Mobile Steam Generator Ex-Stock available :- Oil Gas fired , having Steam Generation Capacity of 25TPH , 25 Bar , 280 Deg.C Super Heated Steam Temp. Truck Trailer mounted Mobile Steam Generators , available from 1TonsHr to 30 TonsHr Capacity. Option of Supe Heated Steam Available. The World renowned D Type Bi-Drum Water Tube design , which is proven for many years for the RELIABILITY of PERFORMANCE & Sturdiness. For Membrane Walls , 63.5 mm Size of Water Tubes are used , instead of 50 mm (as used by others). Hence , over all Water Holding capacity is comparatively high. Hence , the boiler responds quickly to the sudden Peak load steam demand. 30 mm wide Membrane Strips are used in between 63.5 mm OD Membrane Wall tubes , instead of 50 mm Wide membrane Strips nbetween 50 mm OD Mebrane Wall Tubes. Hence , the Membrane Wall cooling is more effective and Membrane Wall never get cracked owing to the high heat flux.

    Working Pressure : 44 Bar

    ...more
    Get Best Price
  • D Type Mobile Bi-Drum Water Tube Package Steam Boiler

    D Type Mobile Bi-Drum Water Tube Package Steam Boiler

    Request for Price

    Salient Features: Mobile Steam Generator Ex-Stock available :- Oil / Gas fired , having Steam Generation Capacity of 25TPH , 25 Bar , 280 Deg.C Super Heated Steam Temp. Truck / Trailer mounted Mobile Steam Generators , available from 1Tons/Hr to 30 Tons/Hr Capacity. Maximum Steam Pressure available is 105 Kg/cm2(g). Option of Supe Heated Steam Available. The World renowned D Type Bi-Drum Water Tube design , which is proven for many years for the RELIABILITY of PERFORMANCE & Sturdiness. Robust Design. For Membrane Walls , 63.5 mm Size of Water Tubes are used , instead of 50 mm (as used by others). Hence , over all Water Holding capacity is comparatively high. Hence , the boiler responds quickly to the sudden Peak load steam demand. 30 mm wide Membrane Strips are used in between 63.5 mm OD Membrane Wall tubes , instead of 50 mm Wide membrane Strips nbetween 50 mm OD Mebrane Wall Tubes. Hence , the Membrane Wall cooling is more effective and Membrane Wall never get cracked owing to the high heat flux. To ensure Dry Steam from the Stram Drum , the Cheveron type Steam Seperators are used which effectively separate Water from the Steam. Fully Wet Back design , by incorporating the Membrane Wall at the rear side of the boiler where flue Gas take turn for the second pass. Oil / Gas Burner used is Stepless Modulation which ensures ultimate efficiency at varied load pattern. Quick delivery of the Entire Boiler Package with Burner & Economizer. Finned Tube Economizer is incorporated for the highest heat recovery , in case of Gas Fired Boiler. Option of Dual Block burner with Extra Combustion Air Pre Heater is available for the further heat recovery. Boiler thermal efficiency is 93%.

    ...more
    Get Best Price
  • Coal Fired Thermic Fluid Heater

    Coal Fired Thermic Fluid Heater

    Request for Price

    Automatic Mechanised screw fuel feeding makes fuel feeding OFF & ON when set temperature is achieved & reduced, respectively.Micro Processor Based VF fuel feed drive is used to adjust the rate of fuel feeding as per Plant load requirement. Most of the Solid Fuels, including Crushed Coal Lignite Agro waste DOC Saw Dust can be used in this system.Large size Air Pre-Heater Water ,Pre-Heater, reduces dry flue gas losses and improves the Waste Heat Recovery and increases combustion Air Temperature.

    ...more
    Get Best Price
  • Bi Drum Boiler

    Bi Drum Boiler

    Request for Price

    Bi-Drum Water Tube Steam Boiler design, which is highly acclaimed ail over ward for it's reliability of performance & sturdiness. Water Wall 2½" size Tubes are spaced 1" apart. This provides larger volume of Water in our Furnace Walls and contributes to a faster load response. In addition, our uniquely designed Drum internals can handle varying loads without circulation disruptions on carry over.Furnace Wall Water Cooling includes side walls & roof, eliminating Refractory and its attendant Maintenance.Gas tight setting Membrane provides the gas tight setting, which eliminates dew - point sulfur corrosion and outages caused by gas, leak Par's Membrane Panels use larger diameter Tubes and Small Membrane spacing which provides the best combination of heat Veneer efficiency & Maintenance accessibility.

    ...more
    Get Best Price
  • air pollution control equipments

    air pollution control equipments

    Request for Price

    Like Two Field ESPs, Three Field ESPs, On-Line Pulse Jet Bag Filter Plants, Wet Scrubbers, Cyclones, Mechanical Dust Collectors. Electrostatic Precipitator (ESP) Electrostatic precipitator (ESP) is a widely used device in so many different domains to remove the pollutant particulates, especially in industrial plants. And as it name implies it uses the electrostatic fundamentals (corona discharge) for trapping and removing industrial emission like boiler exhaust. That’s why it is named as ESP. Physical components of Electrostatic Precipitator Collecting and discharge electrodes Collecting electrodes plate type and tube type. Occasionally made of stainless or an alloy steel. Generally 0.05 to 0.2 cm in thick. Discharge electrodes plate type and wire type made of high carbon steel but also can be constructed of S.S. copper, titanium alloy & aluminum Spikes having a corona material. Comparison of Bag-Filter and ESP Comparison based on parameters For low emission less than 30mg/nm3 go for a bag-filter For high temperature more than 260˚c go for ESP If moisture content in flue gas is more than 20% go for bag-filter If dust resistivity is very high or very low which will be difficult to charge in ESP go for a bag-filter. In power industry normally we find ESP but in cement industry bag-filter is generally used due to dedusting action.

    ...more
    Get Best Price
  • Heating Equipment

    Heating Equipment

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

Contact Information

Par Techno-Heat Pvt. Ltd.

  • Mr.. Rajan Dave
  • Plot No.7, Natraj Industrial Area,Vasna-Iyava, Sanand, Viramgam Road, Ahmedabad, Gujarat

Find Popular Coal Fired Thermic Fluid Heater Dealers

top