water analyzer
Micro controller Based Measures pH Measures mV ORP Measures Conductivity TDS Measures Salinity Measures Dissolved Oxygen Measures Temperature Measures Colorimeter Measures Turbidity
...moreVisiscan Spectrophotometer
Micro-controller based,2 Line 20 Characters LCD,Single Wavelength, Multi Wavelength, Scan Operating modes,4 Position automatic sample changer (Optional)Printer interface,PC interface
...moreVisible Double Beam Spectro(ICON)
Double Beam Optics,Online Measurements,4 Line 20 Characters LCD,%T, Abs, Conc. measuring modes,Single Wavelength, Multi Wavelength, Scan Operating modes,Auto Wavelength & Base Line Correction,Save Recall Facility for Data Test.,Printer interface (Optional)
...moreUV-VIS Digital Spectrophotometer
High resolution, reliable, single beam, manual,0.5 nm Bandwidth,Wide range, low noise Photo multiplier tube (PMT) detector,Manual 4 position sample changer Digital Wavelength with 0.1 nm increments.
...moreUv Spectrometer
Micro-controller based Double Beam Graphic LCD 190 – 1100 nm Range 1 nm Bandwidth Compliance with Pharmacopoeia GMP & GLP Compliance Holographic Concave Grating Automatic source optimisation, Base line calibration & Cell optimisation %T, Abs, Conc. (K factor, Multi standard), Multi component measuring modes Single Wavelength, Multi Wavelength, Scan & Time Scan operating modes Printer interface for 80 Column D.M. Printer PC interface (Optional) Single Position 50100 mm Cuvette Holder
...moreTurbidity Analyzer
Accurate and elegant manual instrument Range : 0 – 1 NTU, 0 – 10 NTU, 0 – 100 NTU & 0 – 1000 NTU Readout : 3 ½ digit LED
...moretds monitor
Manual instrument, convenient for routine analysis Cond. Range : 0 µS – 20 mS with 0.1 cell, 0 µS – 200 mS with 1 cell Cond. Resolution : 0.01µS TDS Range :0 ppm – 20 ppt with 0.1 cell, 0 ppm – 200 ppt with 1 cell TDS Resolution : 0.01 ppm Temperature : 00 C – 1000 C (Auto Manual) Readout : 3 digits LED
...moreSmart UV-VIS Double Beam Spectrophotometer
Micro-controller based Double Beam,Automatic source optimisation, Base line calibration & Cell optimisation,Graphic LCD,%T, Abs, Conc. (K factor, Multi standard), Multi component measuring modes,Single Wavelength, Multi Wavelength, Scan & Time Scan operating modes,Printer interface for 80 Column D.M. Printer.,Automatic 5 position sample changer
...morePC Based UV-VIS Spectrophotometer
PC Based,Automatic source optimisation & base line correction,%T, Abs, Conc. (K factor, Multi standard up to 5) measuring modes,Single Wavelength, Multi Wavelength, Scan (with multi scan facility), Time Scan operating modes,Automatic 5 position sample changer,Single Position 50100 mm Cuvette Holder (Optional)
...morePC-Based Double Beam UV-VIS Spectrophotometer
PC Based Double Beam,Automatic source optimisation, Base line calibration & Cell optimisation,Single Wavelength, Multi Wavelength, Scan (with multi scan facility), Time Scan, Kinetic scan operating modes,Automatic 5 position sample changer,Single Position 50100 mm Cuvette Holder (Optional)
...moreMicrowave Digester
Industrial-quality components made of 316L stainless steel and built by seamless laser welding Multi-layer Dupont PFA coating efficiently protects cavity away from corrosion 56L large cavity provide large batch of vessels(up to 40 vessels) Maximum withstanding temperature: 350?
...morehigh performance liquid chromatographs
SYS LC 138 adopted the trinity system of column over, system controller and solvent tray as a whole, which can reasonably use the space and enhanced the management of temperature and solvent.Conform to GLPGMP, equivalent to 21CFR Part II standard.
...moreFLAME PHOTOMETERS
Enables speedy and accurate estimation of minute quantities of Na, K, Ca & Li Display : 2 ½ Digit LED Minimum Sample Volume : 3.5 ml Result within 30 seconds (Approx.) Air compressor with built-in air regulator and air filter (SYSTRONICS Model 126)
...moreDouble Beam UV-VIS Spectrophotometer 2205
Micro-controller based Double Beam,Compliance with Pharmacopoeia,GMP & GLP Compliance,Holographic Concave Grating,Automatic source optimisation, Base line calibration & Cell optimisation,%T, Abs, Conc. (K factor, Multi standard), Multi component measuring modes,Single Wavelength, Multi Wavelength, Scan & Time Scan operating modes,Printer interface for 80 Column D.M. Printer
...moreDigital Water Analyzer
Measurement of pH, mV, EC (Electrolyte Conductivity), TDS and Salinity are possible pH, EC , TDS or Salinity (Any of one at a time) parameters displayed along with temperature of sample 240 * 128 Monochrome LCD Display Back up for calibration data 500 Measured readings data stored for all four parameters along with temperature Recall saved data for view, print etc. In pH mode: 2, 3, 4 & 5 point calibration option, with user & STD buffer selection Measurement Display with BIG FONT
...moreDigital Spectrophotometer
High accuracy and reliability,4 Digit Seven Segment LED,340 960 nm Range,%T, Abs, Conc. measuring modes,10 nm Bandwidth,Single Position 2050 mm Cuvette Holder (Optional)
...moreDigital Potentiometer
High quality precision manual instrument Accurate End point Uniform Stirrer mV Range : 0 - +1999 Resolution : 1 mV Readout : 3 ½ digit LED
...moreDigital Colorimeter
%T & Abs. 1ml Sample volume Display : 3 Digit LED Light source : White LED Eight Optical filters on a turret to cover 400 – 700 nm
...moreController Based Visible Spectrophotometer
Micro-controller based,Digital Wavelength,Photometric Readout 4 Digit LED,5 nm Bandwidth,Single Position 2050 mm Cuvette Holder (Optional)
...moreController Based Visible Spectrophotometer
Micro-controller based,4 Digit LED,340 960 nm Range,%T, Abs, Conc. & K factor measuring modes,5 nm Bandwidth,Single Position 2050 mm Cuvette Holder (Optional)
...moreController Based Visible Spectrophotometer
High accuracy and reliability 4 Digit Seven Segment LED 340 – 960 nm Range %T, Abs, Conc. measuring modes 10 nm Bandwidth Single Position 2050 mm Cuvette Holder (Optional)
...moreController Based UV-VIS Spectrophotometer
Micro controller based, stand alone unit,Automatic source optimisation,Single Multi wavelength and Spectrum Time Scan operating modes,Date processing (through optional PC) Peak-pick, Point-pick, Expansion Overlaying Averaging Subtraction 1st to 4th derivatives of spectra, besides storage and retrieval of data,Automatic 5- position sample changer. 500 µl sample in 1ml cuvette and 2 ml in 4 ml cuvette
...moreController Based Spectrophotometer
Micro controller based operation,5nm Bandwidth,Single soft touch key for Zero & 100% T setting,4 modes of measurement : %T, ABS, Concentration and K factorRS 232 interface
...moreConductivity Analyzer
Manual instrument, convenient for routine analysis ,Range : 0 µS – 200 mS Resolution : 0.1µS Temperature : 00 C – 1000 C (Manual) Readout : 3 digits LED.
...moremicrowave digestion system
Adopt panasonic inverter technology and realize non-pulse continuous microwave output, which can satisfy small-batch continuous tunable microwave outputtemperature sensor directly monitors and controls temperature change inside the reaction vessel in real time. High precision high temperature melt pressure sensor directly measures the pressure of the reaction vessel in real time and cooperates with temperature sensor to control the pressure sloping touch panel design with 5.6” colorful lcd screen can satisfy the requirement of intuitive and convenient operation.
...moreBe first to Rate
Rate This