Qubit 4 Starter Digital Photo Fluorometer with WiFi
Get Price Quote
1 1 kit (MOQ)
Sample Volume 1 to 20 µL Includes Fluorometer, Assay Tubes, Wi-Fi Dongle, Assay Kit Excitation Wavelength 470 nm (Blue LED), 635 nm (Red LED) For Use With (Equipment) Qubit Fluorometer Product Line Qubitâ„¢ Type Qubit 4 RNA IQ Starter Kit, with WiFi For Use With (Application) sdDNA Quantification, RNA Quantification, Protein Quantification Unit Size 1 kit Â
Digital Photo Fluorometer
Get Price Quote
Best Deals from Digital Photo Fluorometer
681 Digital Fluorometer
Get Price Quote
1 Piece (MOQ)
Digital Photo Fluorometer Model 681 is designed for precise analysis of fluorophors such as vitamins, quinine, steroids, fluorescein, metal complexes, etc. The Fluorescence is caused by the absorption of radiant energy and the re-emission of some of its energy in the form of light. In fluorescence, the excited molecule returns to the ground state immediately after excitation, when the fluorescent molecule is excited at the fixed wavelength (primary filter). The amount of light emitted is measured at the particular wavelength (secondary filter). Fluorometer method for the determination of fluorophors is more sensitive than the Colorimetric method. The Primary Filters – Corning 5840 & Corning 5113 and secondary filters – Corning 4308, Corning 3486 and Corning 3385 mounted on holders are supplied with the instrument The fluorescence is collected at 90 degree angle to minimize the interference of excitation source to fall on the sample solution only during a measurement. Features 3 Digit LED display Covers entire visible range Determines the concentration of Flurophors & Quinine
Digital Fluorimeter
28,500 - 42,500 Per one
Technical Specifications  Fluoro Sensitivity : Full scale deflection obtained with 1 ppm quinine sulphate in 0.1 N sulphuric acid (primary wavelength 360 nm) Display : 3 Digit 7 Segment Red LED Excitation source : 50 W Tungsten Halogen Lamp Sensitivity Range : Adjustable in 4 ranges Primary Filters : Corning 5840 and Corning 5113 mounted on holders Secondary filters : Corning 4308, Corning 3486 and Corning 3385 mounted on holders Detector : Highly sensitive wide range Photodiode Sample Test Tubes : 15 mm (D) X 80 mm (H) Minimum Sample : 4 ml Power : 230 V ±10% AC, 50 Hz. Weight  4.5 Kg (approximately) Dimensions : 260 X 335 X 160 mm ( L X B X H )  Accessories  Test Tubes : A set of 5 Dust Cover : 1 No. Instruction Manual : 1 No. Primary and Secondary Filters : A set of  5
Digital Photo Fluorometer
Get Price Quote
1 Piece (MOQ)
Digital Photo Flurormeter
Get Price Quote
20 Piece (MOQ)
PAM-2500 Portable Chlorophyll Fluorometer
Get Price Quote
For basic and applied research; plant screening,Fully computer controlled; optional ultra-mobile PC for field work and touch screen operation,Optional accessories for algae and cyanobacteria
Spectro Fluorometers
3,000,000 Per Piece
Digital Fluorometer
Get Price Quote
1 Piece(s) (MOQ)
We offer fluorometer.3 digit led display covers entire visible range determines the concentration of flurophors & quinine full scale deflection obtained with 1 ppm quinine sulphate in 0.1 n sulphuric acid (primary wavelength 360 nm) 3 digit bright red seven segment led display 12v, 50w tungsten halogen lamp highly sensitive wide range photodiodecell 15 mm (d) x 80 mm (h) primary and secondary filters: a set of 5, test tube: a set of 5, minimum sample - 4 ml.
FLUORAT-02-PANORAMA SPECTRO FLUOROMETER
Get Price Quote
FLUORAT-02-PANORAMA spectrofluorometer is the most sophisticated instrument among the FLUORAT-02 family. It is intended for scientific research, chromatographic analysis, and for operation as part of multimodule automatic measuring facilities. The spectral regions in the excitation and detection cahnnels are set by built-in fast monochromators. The monochromators are controlled independently, so that the analyst can program any of their operation functions in the process of measuring, in particular, the spectra can be synchronously scanned.
Digital Photo Fluorometer
Get Price Quote
Digital Photo Fluorometer
18,999 Per unit
1 unit (MOQ)
220V Digital Photo Fluorometer
22,500 - 32,500 Per piece
1 p (MOQ)
Digital Photo Lamp
Get Price Quote
100 Piece (MOQ)
fluorometer
Get Price Quote
01 Set(s) (MOQ)
In a filter fluorometer, a light source emits light of an excitation wavelength that is relevant to the compound to be measured. Filter fluorometers produce specific excitation and emission wavelengths by using optical filters. The filter blocks other wavelengths but transmits wavelengths relevant to the compound. The light passes through the sample to be measured, and a certain wavelength is absorbed while a longer wavelength is emitted. The emitted light is measured by a detector. By changing the optical filter, different substances can be measured. SALIENT FEATURES â€Â¢ Highly sensitive, a full scale reading of 199.9 can be adjusted even with 0.2 ppm of quinine sulphate solution in 0.1 N sulphuric acid & primary filter of peak transmission at 366 nm. â€Â¢ Only 5 ml of sample needed. â€Â¢ Range Selection in four steps. â€Â¢ Coarse & Fine gain Adjustment and Offset Adjustment. â€Â¢ Separate power ‘ON’ switch for Lamp to conserve life of the Lamp. APPLICATIONS â€Â¢ Analysis of Pharmaceutical products, particularly vitamins. â€Â¢ Metallurgy â€Â¢ Chemical Industries â€Â¢ Research Institutions
Chlorophyll Fluorometer
Get Price Quote
Field Portable Pulse Modulated Chlorophyll Fluorometer
Get Price Quote
Pulse-modulated system Compact Field Design Temperature Compensated Electronics Programmable by Hansatech Scripting Language (HSL) Leaf-clip with integral PARtemperature sensor Field Swappable Battery System Windows® data acquisition & data analysis software
Digital Photo Fluorometer
Get Price Quote
fluorometer
Get Price Quote
fluorometer
Get Price Quote
Digital Fluorometer 681
Get Price Quote
3 Digit LED display,Covers entire visible range ,Determines the concentration of Flurophors & Quinine
Chlorophyll Fluorometer
Get Price Quote
Far-famed for the outstanding range of Chlorophyll Fluorometer; we are a leading name in this trade. We are celebrated name based in Haryana(India) and actively engrossed in making available high quality products at the most reasonable prices.
Fuorometer
Get Price Quote
ilter fluorometer, a light source emits light of an excitation wavelength that is relevant to the compound to be measured. Filter fluorometers produce specific excitation and emission wavelengths by using optical filters. The filter blocks other wavelengths but transmits wavelengths relevant to the compound. The light passes through the sample to be measured, and a certain wavelength is absorbed while a longer wavelength is emitted. The emitted light is measured by a detector. By changing the optical filter, different substances can be measured.
Digital Photo Fluorometer
Get Price Quote
Digital Photo Flurometer measures fluorophors like vitamins, quinine and metals. Supplied with 2 primary and 3 secondary filters mounted on holders. Results are displayed on 3 digit 7 segment LED. Sensitivity in 4 ranges. Highly accurate & stable. Â
Digital Fluorometer
Get Price Quote
Advanced Technocracy Inc. is Manufacturer, Exporter & Supplier of DIGITAL FLUOROMETER .
Digital Photo Fluorometer
Get Price Quote
Digital Photo Flurometer measures fluorophors like vitamins, quinine and metals. Supplied with 2 primary and 3 secondary filters mounted on holders. Results are displayed on 3 digit 7 segment LED. Sensitivity in 4 ranges. Highly accurate & stable. Â
Photo Fluorometer
Get Price Quote
We are also known in the industry for offering best qualityDigital Photo Fluorometers that are available at most competitive price rates. These products are used for analysis of fluorophors such as vitamins, quinine, steroids, fluorescein and metal complexes among others. Our Digital Photo Fluorometers are highly appreciated in the market for best design and effective operation. These Digital Photo Fluorometers can be offered as per the client's requirement.
Digital Photo Fluorometer
Get Price Quote
Digital Photo Flurometer measures fluorophors like vitamins, quinine and metals. Supplied with 2 primary and 3 secondary filters mounted on holders. Results are displayed on 3 digit 7 segment LED. Sensitivity in 4 ranges. Highly accurate & stable.
Digital Fluorometer
Get Price Quote
Digital Photo Fluorometer
Get Price Quote
We are into offering best quality Digital Photo Fluorometer that is used for analysis of fluorophors such as vitamins, quinine, steroids, fluorescein, metal complexes etc. Our Digital Photo Fluorometer is highly in demand for the best design and effectual operation. We offer our Digital Photo Fluorometer as per the client�s requirement. Technical Details Primary filters : Corning 5840 & Corning 5113 Secondary filters : Corning 4308, Corning 3486 and Corning 3385 mounted on holders as part of the instrument Digit 7 segment Red LED display < Popular for Durability Optimum quality Easy maintenance Effectual performance Long service life