Multimedia Water Filtration System
Get Price Quote
ultra filtration
Get Price Quote
The UF system utilizes state-of-the-art, pure polysulfone hollow fibers are asymmetric with the feed stream entering the inside, or lumen of the 35 millimeter (mm) inside diameter fiber. Under pressure of about 15 pounds per square inch (psi), the permeate passes through the membrane at approximately 100 gallons per square foot per day (gfd) flux rate. A backwash is typically engaged via a programmable logic controller (PLC) device on a regular schedule-perhaps hourly. This keeps the UF membrane surface clean even when turbidities spike to over 100 NTUs. The polysulfone fiber is chlorine tolerant and can thus be easily disinfected using chlorine. The UF cartridges are housed in a clear vessel allowing for fiber integrity testing using a visual method or an automatic pressure decay test included in the logic of the PLC.
Best Deals from Industrial Water Filters
ultra filtration
Get Price Quote
ultra filtration, commercial water purifiers, Pumps
Arsenic Removal Plant
Get Price Quote
Arsenic Removal Plant, RO Plant Repairing Service