Single & Double Barrel Tension Tester
Single Barrel Tension Tester : 30 lbs.
Double Barrel Tension Tester : 66 lbs.
Capacity of Tester : 0-250kg
Speed Range : 0.1 mm / min to 500 mm / min
Touch Pad HMC Size : 7 inch
Displacement Resolution : 0.1 mm
This is very simple and efficient handy tool for use with all small V-Belt and synchronous drives, including PowerBand® and Poly Chain® GT® belt drives.
ac high voltage breakdown tester
Dimensions : 300 X 230 X 225
We are offering a precision engineered range of A.C High Voltage Breakdown Testers, which is widely used for checking the high voltage withstanding capacity of insulation material. Our range is extensively used in railways, electricity boards, defense, communication centres, R & D units. Moreover, our range is appreciated for offering great operational flexibility and hassle free services for years.
voltage testers
19,000 - 20,000 Per Piece
Feature : Optimum performance, Compact size, Defect free
Fume Hood
We are offering fume hood a fume hood or fume cupboard is a type of local[1] ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapors or dusts. A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height. two main types exist, ducted and recirculating. The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. other related types of local ventilation devices include: clean benches, biosafety cabinets, glove boxes and snorkel exhausts. All these devices address the need to control airborne hazards or irritants that are typically generated or released within the local ventilation device. All local ventilation devices are designed to address one or more of three primary goals: to protect the user (fume hoods, biosafety cabinets, glove boxes); to protect the product or experiment (biosafety cabinets, glove boxes); to protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream). secondary functions of these devices may include explosion protection, spill containment, and other functions necessary to the work being done within the device. a general but non-specific term for some of these local ventilation devices is laminar flow cabinet. This category may include clean benches, biosafety cabinets and other devices characterized simply by the laminar nature of their airflow. The term laminar flow cabinet, however, is insufficient to identify their actual design and use - some will protect the product but not the user, and others will protect both. Terminology for local ventilation devices has been, and remain, unclear and non-specific, and the reader is advised to take special care in their selection and specification based upon which of the three primary goals (listed above) are to be met. fume hoods typically protect only the user, and are most commonly used in laboratories where hazardous or noxious chemicals are released during testing, research, development or teaching. They are also used in industrial applications or other activities where hazardous or noxious vapors, gases or dusts are generated or released. because one side (the front) of a fume hood is open to the room occupied by the user, and the air within the fume hood is potentially contaminated, the proper flow of air from the room into the hood is critical to its function. Much of fume hood design and operation is focused on maximizing the proper containment of the air and fumes within the fume hood. as most fume hoods are designed to connect to exhaust systems that expel the air directly to the exterior of a building, large quantities of energy are required to run fans that exhaust the air, and to heat, cool, filter, control and move the air that will replace the air exhausted. Significant recent efforts in fume hood and ventilation system design have focused on reducing the energy used to operate fume hoods and their supporting ventilation systems.
Conductivity Sensor
Material : Plastic
Application : Automobile Use
Color : Black
Power : 15w, 20w
Warranty : 2years
Alarm Range : 1.5mtr
Our broad range of conductivity cells encompasses three measuring techniques: 2-electrode cells for µS/cm ranges 4 and 6 electrode sensors for mS/cm ranges non-contact, electrode-less sensors. Multi-electrode and electrode-less (toroidal) sensors tend to be used for applications with aggressive chemicals or where there can be sensor coating or fouling.
digital energy meters
Based in Telangana(India), we have gained wide appreciation owing to our high quality products and client-centric approach. We guarantee to make on time delivery, as we have an extensively spread network of logistic facility providers and dealers.
insulation resistance testers
37,065 Per Piece
Fluke 1507 and 1503 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications. Features • Read measurements easily with large, backlit display • CAT IV 600 V overvoltage category rating for added user protection • Remote probe, test leads, probes and alligator clips included with each tester • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work • Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests • One year warranty
Digital Conductivity Meter
Facility for measurement of absolute cell constant, selection & adjustment of cell constant, Temperature compensation from 0 to 50°C (Manual), Capacitive correction for higher ranges, Direct reading referred to 25°C.Extendable to measure Total Dissolved Solids. * Capacitive correction for higher ranges . S - Siemens (Mho) (1) Excluding 290 mm Cell Stand (2) Including Instrument and Electrode stand.
Digital pH Meter LI 120
Accuracy : ± 0.01
Range : 0 to 14
Readability : 0.01
Repeatability : ± 0.01
LI-120, Digital PH Meter Manual 2 point calibration for pH,Manual Temperature Compensation,Measures pH and EMF,Accurate & Highly Stable,Elegantly Styled.Small, Laboratory Version
alcohol detector
Intelligent key management with compulsory alcohol testing – this system will not allow vehicle keys, or keys to access hazardous equipment, to be released until the user has passed an alcohol breath test. Can be integrated with series of Traka Key Management Systems. Provides extra access protection from non-alcoholics access the Keys. The alcohol fail level can be set to pre-determined levels such as Zero Tolerance.
Magnetic Flow Meter
100 Piece(s) (MOQ)
Usage : All type of liquids
Packaging Type : Packed in corrugated boxes
Condition : New
The powerful transmitter is easy to use and provides the output signal that meets the needs. Process Master FEP300 is a versatile, reasonably priced, most accurate flow meter tailored for all process industry applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation. Versatile and simple configuration :Through glass configuration eliminating the need to remove the cover and reducing commissioning time Soft key based functionality "Easy Set-up" function State-of-the-art memory technology : Data storage enables transmitter exchange without the need for reconfigurationDiagnostics for real-life-situations : Simplified plant trouble shooting Status messages in accordance with Namur Help texts in LCD display Scan Master in situ verification software option : Allows the customer to perform in situ verification of the flowmeter and the plant
three phase meter
Electricity has become a basic unit of today’s modernization and business growth. This demands reliable and accurate devices to measure and track the quality and consumption of electricity, by both suppliers and consumers. winAMR focuses on design and development of modern metering products which assures precise and trustworthy metering, thus ensuring increased revenues for winAMR clients. winAMR offers dynamic meters specifically designed for remote communications with a variety of metering systems. Our smart meters are very economical and efficient alternatives for metering applications; ranging from residential, commercial, municipalities and industrial in regulated and deregulated markets.winAMR’s novel electronic Single and Three Phase Meter – IEC 62053 or BSEN 504701,3 promises high quality, accurate measure, value for customers and is an universal application with hybrid communication standards.winAMR’s smart meter features advanced function circuits boards, which is easy for up-gradation and abide to international (IEC) and national standards such as DIN, BS, VDEW, and ANSI.winAMR offers a line of electronic and electo-mechanical single and three phase meters giving our client a choice of cost-effective meters for measuring kilowatt-hour energy consumption. With the hybrid communication options and support software, our single and three phase meters can be easily incorporated into automated meter reading systems.
Watt Loss Testing Equipment
We offer Watt Loss Testing Equipment For Electrical Steel. The equipment takes measurements on strip samples using Epstein Square stack (IS 649) and on samples in the form of toroids (ASTM A912A 912M-04). Can take measurements on Stator Stacks.
Brick Testing Equipment
Features : Highly demanded, Rigid construction, Excellent performance
Three Phase Digital Energy Meter
VISIONTEK 37TM Three Phase Electronic Energy Meter is designed to meter residential and commercial category consumers in distribution networks. The meter is targeted at the deregulated energy markets which require flexible tariff structures and a modern energy management.37TM is a perfect combination of well-proven metering technology sealed in a single enclosure with multiple communication interface options. 37TM Energy Meter complies with IS-13779, CBIP-TR 88 and communication protocol in accordance with BIS ICS ETD 13 doc 6211 (IS 15959) Category C for interoperability.
INSULATION ANALYZER
M4100 Type C - Resonator M7100 Type C - Resonator
Digital Conductivity Meter
32,000 Per Piece
01 Piece (MOQ)
Brand Name : Mettler Toledo
Usage : Industrial, Laboratory
Model : FP 30
Ultrasonic Testing Machines
Olympus make ultrasonic flaw detector for testing the raw material including BNC transducer connectors, multi-color display with multi color schehemes and variable brightness control EP4MCA charger adaptor
Digital Tds Meter
Feature : Test drinking water , High performance, Easy to use
Harness Testing Equipment
Electrical Testing Equipment
THREE PHASE ELECTRONIC ENERGY METERS
TAMPER & FRAUD DETECTION FEATURES Load Reversal & Phase sequence reversal Detection of missing potential Reversal of C.C.(Counter coil) polarity. 2 Phase & Neutral Present 3Phase & Neutral Missing Over Voltage One phase & Neutral Present Abnormal Voltage Voltage unbalance Current Unbalance / High neutral current (CT bypass) Power on time (Phase wise) / DC immunity/ C.C shorting Power on/off/ Recording of Neutral disturbance External Magnetic tampers. SALIENT FEATURES Billing History for last 12 months. Instantaneous voltage / current / Load, Frequency & maximum Demand. Average Power Factor for 30 minute intervals for the last 12 months Load survey for 30 minutes integration time for KW/KVA for 70 days, Communication Media. Optical Port Infra red Rs-232 /RS485 5 Zone TOD KWh, KVAh & kW & kWA Programming is also provided for the RTC Calibration / T .O.D. configuration Power fail logic provided to read the data on L.C.D. COMMUNICATION FACILITIES RS 232 RS 485 Isolated Optical Communication port Through CMRI/Public Switch Telephone Network/Low Power radio/GSM. SOFTWARE Base computer system with the facility to convert required data into formats as per utility requirement for billing purpose.
dead weight with top