filter reactors
Get Price Quote
Filter reactors are used along with capacitor banks to form the tuned harmonic filter circuit for a particular harmonic. If different harmonic currents are to be eliminated from the system, number of filter circuits tuned to each harmonic frequency need be installed. Installing filter circuits is necessary where the harmonic exceed the permissible level, otherwise the excessive harmonic currents can cause higher losses resulting in higher temperature and dielectric stresses. Installing filter circuits is necessary where the harmonic exceed the permissible level, otherwise the excessive harmonic currents can cause higher losses resulting in higher temperature and dielectric stresses. We are able to offer Harmonic Filter reactors in oil cooled as well as air cooled version depending upon the customer's requirement.
Detuned Filter Reactor
Get Price Quote
Three Phase, Iron Core Reactor with Air Gaps, Poly Gap (R) Core DesignComplete Unit Vacuum – Overpressure Impregnated with Temperature Class H Resin and cured in an Oven Distortion
Best Deals from Harmonic Filter Reactor
Three - Phase Filter Reactor
Get Price Quote
Three - Phase Filter Reactor are used with shunt capacitor banks to prevent harmonic responce and also harmonic overloading of capacitor banks. These reactors are characterized by high lineraity, low loss and compact size. Highest linearity, low risk of reactor tilting.
Filter reactor
Get Price Quote
Filter reactors are used along with capacitor banks to form the tuned harmonic filter circuit for a particular harmonic. If different harmonic currents are to be eliminated from the system, number of filter circuits tuned to each harmonic frequency need be installed. Installing filter circuits is necessary where the harmonic exceed the permissible level, otherwise the excessive harmonic currents can cause higher losses resulting in higher temperature and dielectric stresses. We are able to offer Harmonic Filter reactors in oil cooled as well as air cooled version depending upon the customer's requirement.
detuned reactors
Get Price Quote
ACE detuned reactors are high quality reactors designed to be used in detuned power factor correction. ACE has a standard range of reactors with P=7% which means a resonance frequency of 189Hz for 50Hz networks or 227Hz for 60H networks.
Filter reactor
Get Price Quote
The increasing use of modern power electronic apparatus (drives, uninterruptible power supplies, etc.) produces nonlinear current and thus loads the network with harmonics. The capacitance of the power capacitor forms a resonant circuit in conjunction with the feeding transformer. Experience shows that the self-resonant frequency of this circuit is typically between 250 and 500 Hz, i.e. in the region of the 5th and 7th harmonics. Typical loads requiring harmonic filtering include 6 pulse drives (AC DC), 3 phase UPS, frequency converters
Detuned Filter Reactor
Get Price Quote
Detuned Filter Reactor Features :- Available as 7% (189 Hz) & 14% (133 Hz) detuned filters Copper & Aluminium wound reactors Very low operating losses - 3 to 5 W kVAr High linearity - 1.8 times the rated current Low noise Auto-thermal cut-off.
Harmonic Filter Reactor
Get Price Quote
Detuned harmonic filters are the series combination of a reactor and power capacitor. This filter offers higher impedance for high frequency harmonics. This prevents harmonic resonance and amplification. 7% reactor mitigates 5th harmonic & above For industries with drives, converters & other power electronic devices 14% reactor mitigates 3rd harmonic & above For IT industries For industries with high single-phase non-linear load
filter reactors
Get Price Quote
filter reactors, Electric Arc Furnace Duty Reactors, series reactors
Harmonic Filter Reactor
Get Price Quote
Harmonic Filter Reactor, Solar LED Torch, automatic power control panel
detuned reactors
Get Price Quote
detuned reactors, Sigma Servo 5 Drive, crane panel