Cooling Systems Dealers in Navi Mumbai (7 products available)

  • Geothermal Cooling System

    Geothermal Cooling System

    Get Price Quote

    Our organization stocks the items in mass. Therefore, we can serve mass retail requirements without hassle and make sure delivery of products is swift. In order to keep our offerings in safe and secure conditions, we have developed a storage unit and keep it updated with the defined industry standards.

    ...more
  • outdoor cooling system

    outdoor cooling system

    Get Price Quote

    Type : Water Mist System

    Material : Stainless Steel

    Usage/Application : Dust free chamber

    Capacity : 48000/14 BTU/hr

    Dimensions : 1040 x 1040 x 1105 mm

    Frequency : 50 Hz

    Features : High quality, Adorable designs, Very robust, Long lasting.

    ...more
  • Best Deals from Cooling Systems

  • Two Phase Liquid Cooling system

    Two Phase Liquid Cooling system

    Get Price Quote

    Configuration : Application specific sizes

    Performance : Cooling is application specific

    Operating Temperature (C) : Application specific, typically -54° to +71° C

    Developed by Parker Hannifin’s Gas Turbine Division, the unique macrolaminate construction employs a diffusion-bonding manufacturing process. This process allows multiple layers of extremely thin material to be bonded together, resulting in a finished product that has a material strength greater than 90 percent of the base material. Each layer may contain complex liquid paths that transport the coolant to specific areas of concentrated heat flux. This multilayer approach results in the ability to create parallel “low temperature” flow paths for the coolant prior to reaching multiple locations of the specific heat sources. The unique manufacturing process includes the capacity to produce fluid channel passages with extremely high aspect ratios. A “slot” style fluid channel provides the most efficient method of thermal transfer (maximum contact area versus volume) from the cold plate wall to the coolant. Thin cold plates and low-fluid volumes result in reduced sizes for any associated pumps or reservoiraccumulators in the overall system, contributing towards size, weight, and power (SWAP) benefits. Very large format cold plates may be constructed with fluid passages of greater size and may therefore utilize vacuum brazing as a construction technique. Single-phase and two-phase cooling can be achieved with a variety of fluids or refrigerants. Two-phase cooling may require the cold plate to operate with the coolant under considerable pressure. Parker has many years of experience manufacturing and testing complex fluid management systems and components that need to operate under extreme pressures in harsh environments.

    ...more
  • Chilled Water System

    Chilled Water System

    Get Price Quote

    Industrial Refrigeration offers Chilled Water System for food, pharma, & chemical industries. IRL manufactures Water Cooled Screw Chillers incorporating reliable screw compressors from Bitzer (Germany) and Frascold (Italy). These chillers are fully Microprocessor based suitable for process cooling applications from (+) 20˚C up to (-) 40˚C. For lower temperatures of up to (-) 50C look into Brine Chillers. These screw chillers are offered with up to 2 Nos. screw compressors in one machine but having separate and individual refrigeration circuits. These chillers are world class, manufactured in an ISO 9001, certified factory with an option of using CFC free refrigerants R-407C & R-134a complete with in-built Process pump and stainless steel chilled water expansion tank. These chillers are also rated for an ambient of up to (+) 50˚C and cooling tower water temperature up to (+) 37˚C at the inlet of the condenser. The various operating voltages of these chillers are: a) 380 / 400 Volt AC / 50 HZ b) 460 Volt AC / 50 HZ c) 380 Volt AC / 60 HZ d) 460 Volt AC / 60 HZ. Features : RELATED ALL TYPE CHILLER The glycol chillers, brine chillers, air cooled brine chillers, water cooled brine chillers and liquefiers offered by IRL are tailor made to suit customer requirement. IRL offers these low temperature Glycol / Brine up to an operating temperature of (-)50˚C for which compressors can be single stage open type / double stage open type / double stage semi hermetic / single stage screw depending on the size and the temperature requirement of the customer. For very low temperature application even Cascade systems are used for quick cooling. The material of construction is selected carefully depending on the application temperature and special alloys steel is used for ultra lower temperature application. These chillers can be air-cooled or water-cooled depending on the customer requirement. These chillers are rated for an ambient of (+) 480C and various operating voltages which are: a) 380 / 400 Volt AC / 50 HZ b) 460 Volt AC / 50 HZ c) 380 Volt AC / 60 HZ d) 460 Volt AC / 60 HZ Applications : Food processing industry Accelerating mould of plastic. Extending the life-span of mechanical components. Electronic industry and ultrasonic cleaning industry. Electroplating industry cooling to enhance precision of electroplating. Food processing industry cooling to enhance the quality of food. Advantages : Water temperature can be set at random from 0.5 degrees to 20 degrees. Intelligence control system can automatically adjust the load increasing and decreasing of the compressor to maintain outlet temperature in certain degree based on water temperature. The flow of water varies from 1.5m3/h to 24m3/h, which can meet different needs. Containerized structural design, which can be transported to places where refrigeration is needed.

    ...more
  • Mini Cooling System

    Mini Cooling System

    Get Price Quote

    Mini Cooling System, Handy Sampler

  • Chilled Water System

    Chilled Water System

    Get Price Quote

    Chilled Water System, Corrosion Inhibitor, Ph Booster, cleaning chemical

    ...more
  • Air Cooling Systems

    Air Cooling Systems

    Get Price Quote

    Air Cooling Systems, Fruit Ripening Chambers, Air Ventilation System

    ...more
Filter by Locality
top