Micro Filt India Limited Erandwana, Pune, Maharashtra

  • Vertical Laminar Airflow Cabinet

    Vertical Laminar Airflow Cabinet

    Request for Price

    The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by clear glass panels and sliding glass doors.Room air is taken in from the side of the cabinet through a pre-filter with 90% efficiency which traps particles of 10µ and above.Air is spread evenly across the HEPA filter, thereby providing a steam of clean air withing the work area of the cabinet; this removes all contaminated air from the interior.

    ...more
    Get Best Price
  • Vertical Laminar Air Flow

    Vertical Laminar Air Flow

    Request for Price

    The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by clear glass panels and sliding glass doors.   Room air is taken in from the side of the cabinet through a pre-filter with 90% efficiency which traps particles of 10µ and above. Air is spread evenly across the HEPA filter, thereby providing a steam of clean air withing the work area of the cabinet; this removes all contaminated air from the interior. Perforated Stainless Stell diffuser screen protects the HEPA filter and maintain uniform air flow velocity within the work area Vertical Laminar Flow occupies less space and can be installed in a small area. Provides extra workspace (Depth of 29.5” / 750mm) Advantage of working from both the sides and visibility from all sides.

    ...more
    Get Best Price
  • Vertical Ceiling Laminar Flow

    Vertical Ceiling Laminar Flow

    Request for Price

    The vertical ceiling laminar flow airflow is suspended from the ceiling at a desired height from the floor.       Standard features: It Provides an ISO Class 5 - 14644 - 1 environment within the work area that complies with the latest IEST (Institute of Environmental Sciences and Technology) Recommended Practices. Perforated Stainless steel diffuser screen protects HEPA filter and maintains uniform airflow velocity within the work area. We manufacture variety of Laminar flow units to match various makes of Ampoule / Vial / Powder filling machines as well as Automatic / Semi-Automatic lines. With combination we can give you large size units required by 6/8 Hd as well as other high speed Ampoule / Vial / Filling / Washing machines like 5'x4', 6'x4', 8'x4', 8'x2.5', 8'x6' as well as custom made sizes.

    ...more
    Get Best Price
  • Reverse Laminar Air Flow Unit

    Reverse Laminar Air Flow Unit

    Request for Price

    The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by clear glass panels and sliding glass doors.Room air is taken in from the side of the cabinet through a pre-filter with 90% efficiency which traps particles of 10µ and above.Perforated Stainless Stell diffuser screen protects the HEPA filter and maintain uniform air flow velocity within the work area, Vertical Laminar Flow occupies less space and can be installed in a small area.

    ...more
    Get Best Price
  • laminar flow station

    laminar flow station

    Request for Price

    Portable, economical system converts any bench top surface into a laminar flow station.This versatile laminar flow hood gives particle-free environment in the work area.This model is compact, cost effective and has space saving design.

    ...more
    Get Best Price
  • Horizontal Laminar Airflow Cabinet

    Horizontal Laminar Airflow Cabinet

    Request for Price

    The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by removable clear glass panels and polycarbonate shutter.Room air is taken in from the bottom of the cabinet through a pre-filer with 90% efficiency which traps particles of 10µ and above.Air is spread evenly across the HEPA filter, thereby providing a steam of clean air withing the work area of the cabinet; this removes all contaminated air from the interior.

    ...more
    Get Best Price
  • Horizontal Laminar Air Flow

    Horizontal Laminar Air Flow

    Request for Price

    The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by removable clear glass panels and polycarbonate shutter.   Room air is taken in from the bottom of the cabinet through a pre-filer with 90% efficiency which traps particles of 10µ and above. Air is spread evenly across the HEPA filter, thereby providing a steam of clean air withing the work area of the cabinet; this removes all contaminated air from the interior. Perforated Stainless Stell diffuser screen protects the HEPA filter and maintain uniform air flow velocity within the work area Easy disassembly for access through a small door. Front angular 10 degree slope helps reduce operator fatigue while working on the cabineT

    ...more
    Get Best Price
  • Biosafety Cabinets

    Biosafety Cabinets

    Request for Price

    Bio safety cabinet is designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertrical laminar airflow to create a barrier to airborne particles and micro organisms. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaust the HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter.The class I Biological Safety Cabinet is an open front negative pressure cabinet. The exhaust air from the cabinet is filtered by a high-efficiency particulate air (HEPA) filter. It provides protection to human beings and environment only. Class I cabinets suitable for work shere no product protection is required.

    ...more
    Get Best Price
  • bio-safety cabinet

    bio-safety cabinet

    Request for Price

    Bio safety cabinet is designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertrical laminar airflow to create a barrier to airborne particles and micro organisms. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaust the HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter. BIOSAFETY CABINETS are classified into three categories: Class I, Class II, Class III. Class I: The class I Biological Safety Cabinet is an open front negative pressure cabinet. The exhaust air from the cabinet is filtered by a high-efficiency particulate air (HEPA) filter. It provides protection to human beings and environment only. Class I cabinets suitable for work shere no product protection is required. Class II: The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace. The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is most versatile and economical model.   There are four types of Class II cabinets: Class II Type A1 (formerly designated Type A): It exhausts approximately 30% air back into the laboratory and re circulates the remainder. May have positive pressure contaminated ducts and plenums that are not surrounded by negative pressure plenums. Class II Type A2 (formerly designated Type B3): It exhausts approximately 30% air through a HEPA filter back into the laboratory or to the environment through an external exhaust duct. It has all biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B1: It exhausts 70% air through a dedicated duct exhausted to the atmosphere after passing through a HEPA filter and re circulates the remainder. It has all contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B2: (sometimes referred to as "total exhaust"): It exhaust 100% air through an exhaust duct after passing through a HEPA filter and contaminated positive pressure plenums must be surrounded by a vacuum. Class III: The Class III cabinet is a totally enclosed ventilated cabinet of airtight construction. Operations within the Class III cabinet are through attached rubber gloves. When in use, the Class III cabinet maintains negative air pressure. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by two HEPA filters installed in series, before it is discharged outside the facility. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facilities ventilation system.    

    ...more
    Get Best Price
  • air cleaning equipment

    air cleaning equipment

    Request for Price

    Get Best Price
  • reverse laminar flow booth

    reverse laminar flow booth

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
MICRO-FILT-INDIA was founded in 1978 to manufacture ultra clean air laminar flow equipment of international standards. Since its inception it has worked towards achieving customer satisfaction by providing quality products and services.
We are one of the leading manufacturers of laminar Air Flow and allied equipment in India. Our HEPA filters are manufactured from imported finest quality water repellent and fire resistance Boro-Silicate glass fiber paper as per ISO 14644-1 standards. We also provide customized testing facilities to ensure optimal performance of our units.
We are an ISO 9001:2008 Certified company, and our customers are assured of high standards in product design and manufacturing. We are making continuous efforts on product develpment and efficient after sales service.
Read More »

Contact Information

Micro Filt India Limited

  • Amit Jagdish Latey
  • 31/107 Ganesh Krupa Bharti Niwas Society, Erandawane, Erandwana, Pune, Maharashtra

Find Popular Laminar Airflow / Laminar Air Flow Bench Dealers in Pune

top