OM Industries Shirala, Sangli, Maharashtra

  • Rated Transformers

    Rated Transformers

    Request for Price

    APPLICATIONS : Data centers, IPO centers, UPS, VFD & drives, Hospitals Medical Centers, Research Lab, Corporate Bank Offices, Shopping Malls   Om Make K-Rated Transformers are specially designed to with stand this Harmonic non-linear load K-rating differs according to the harmonic levels like K-1, K-4, K-7, K-13, K-20, K-30, K-40, K- factor is defined as a ratio between the harmonic & eddy current losses at 50Hz / 60Hz It is used to determine how much non-linear Harmonic load / current can with stand transformer to without exceeding it maximum temperature level. The noise Isolation transformer Suppresses common mode noise by introducing a grounded shield between its primary and secondary windings. The grounding shield provide also impendence path to ground by capacitive coupling which prevents unwanted high frequency signals contained in the source voltage form reaching the Transformer secondary. Our special features of K-rated Transformer : Electrolytic grade copper winding, coil designing of high harmonic current carrying & low eddy current losses. We are using high grade (CRGO) 0.23 to 0.27 notching type of lamination which can only prevent core saturation due to non-linear harmonic, working with good flux densities to compensate for harmonic voltage distortion high thermal with stand capacity class "H"insulation multi shielded transformer where you will gate higher common mode noise attenuating and 100% linear harmonic attenuation and more than 75% non-linear loads low temperature rise. We are designing our 'K' Rated Transformer according to its guideline specification given by UL1567, ANSIC57, IEEE-519-1981. 'K' Rated recommendation given by ANSI Standard. CE approved. PRODUCT RANGE : 1. 10KVA TO 1000 KVA Open & Enclosure type

    ...more
    Get Best Price
  • Pulse Transformer

    Pulse Transformer

    Request for Price

    APPLICATIONS : AC & DC Drive, VFD Panels OM has long history of co-operation with utilities and OEM's to design potential transformer for generator exciter applications. Exciter OEM's relay on us to design transformer that address the issue of aaplication heating from harmonics, field forcing conditions. And high available short circuit forms the generator bus. We often work directly with utilities on ppt retrofit project that require electrical design expertise and matching of dimentions and termination locations. OM also provides drive isolation transformer for variable speed drive applications. There units called push transformer. These transformer are designed specification for the inherent harmonics, minimal space, requirement other unique characteristics of drive systems. Our experience includes winding 12, 18 and 24 pulse applications the frequency inverters. The OM series transformer are designed to reduce the harmful harmonic currents produced by pulse parallel input rectifier circuit such as those used in adjustable speed or variable frequency(VFD) drive and 3 Phase computer or other electronic equipment. 6 Pulse rectifier circuit generate significant amounts of low frequency harmonic current if not suitably treated, these harmonics can have many undesirable effects these include. 1) Overheating of transformer cables and other electrical distribution equipment. 2) Poor power factor and premature failure of power factor correction capacitors. 3) High voltage distortion which can cause operational problems and/or component failure in the asd's themselves or other equipment connected to the same distribution. The symmetry of the transformer is a major factor for reducing the harmonic on the medium voltage line the5th, 7th, 11th, 13th, 17th, and 19th Current harmonic are practically nonexistent as they have been cancelled by the shifted transormer winding.

    ...more
    Get Best Price
  • Resistive Load Bank

    Resistive Load Bank

    Request for Price

    APPLICATIONS : Data Centers, Generator OEM'S & Manufature, Commercial Sectors, Telecomuunication Sites, Mining, Military Establishments, Ships & Oil Rig Application, Large Power Plants, Battery Discharge Application Load bank is compact unit that are coupled to the output of your power generation system such as diesel generators, gas turbine or ups and battery system. The necessity and dependence on power at mining site, oil and gas refining in Hospitals and many other essential Services has meant a rapid growth of backup generators and UPS system for backup power. The increase of Computers and telecommunication equipment demands faultless performance in the event of power down conditions, this can only be Full Achieved By resistive Load testing the Stand by system on installation and at regular intervals. The Life and efficiency of diesel generators can be greatly reduced when running under loaded. Lousing damage to the engine to a point Where engines could stall or completely fail to start when they are needed most. Load banks are dummy loads designed to simulate the plant load and prove the design, performance and the capacity of the system without interruption to the normal running of your plant. Load bank are designed for portable resistive and reactive / inductive load Bank one whether proof Constriction, designed for harsh and tough Environment is for testing and commissioning of generators featuring rugged Stainless steel immersion proof and vibration proof resistors high quality class 'F' reactors integrated switch-gear with individual load circuit breakers. Available in standard voltage 440V 3Phase, 50/60Hz. PRODUCT RANGE : 10KW to 3000KW and also customized load bank

    ...more
    Get Best Price
  • LINE CHOKE REACTOR

    LINE CHOKE REACTOR

    Request for Price

    APPLICATIONS : AC & DC DRIVE, VFD PANELS Line chokes are modern technology solution for Drive application. Help keep your equipment running longer by absorbing many of the power line disturbances which otherwise damage or shut down your Inverters, Variable Frequency Drives (VFD), Variable Speed Controllers or other sensitive equipments. They are a robust filtering solution for virtually any 6 pulse rectifier or power conversion unit. There is no need to derate OM LR Reactors as they are harmonic compensated and IGBT protected to assure optimum performance in the presence of harmonic and are very effective at reducing harmonics produced by inverters and drives. Standard OM LR Reactors may be applied up to 690VAC with compatible impedance ratings. High saturation current Rating : Om make Reactors are suitable for use both on input and output side of drive. Om make Rectors are designed (Epoxy impregnation minimizes audible noise in the rector and enhanced structure and moisture integrity. Maximizes their surge current protection capability Om Rector absorbs many of the power line disturbances which cause nuisance trip on voltage source units. Choose The Standard Impedance Level : 1.5%, 3%, 5%, 7% & 10% impedance. Terminals: Terminal is standard and save installation cost by minimizing panel space. Melamine connectors are provided up to 60 Amps. Solid copper box lugs are provides busbar type above 60 Amps. 'CE' marked. Specialized for VFD's : ABB, Delta, Fuzi, Danfoss, Siemens, Yasakawa, Schneider, Parker, Mutsubishi, Toshiba, Vecon & Custom built VFD's. PRODUCT RANGE : 1. 0.5 HP to 1000 HP

    ...more
    Get Best Price
  • Lighting Transformer

    Lighting Transformer

    Request for Price

    APPLICATIONS : Thermal Power Plants, Nuclear Power Plants, Steel Plants, Commercial Complex, Shopping Complex, Hospitals, Data Centres, Hotels, Chemical Plants, Mining, Industries, Housing Societies DRY TYPE LIGHTING TRANSFORMER We offer our premium quality Lighting Transformer. The Lighting Transformer is designed to supply power to lighting equipments in residential, commercial, hotels, hospitals & industrial undertakings. The primary supply in Lighting Transformer is connected to higher voltage source and secondary supply to load & neutral grounding connector. RESIN CAST LIGHTING TRANSFORMER Om makes Dry type Lighting Transformer is complete encapsulation of primary and secondary winding in Epoxy resin. It helps to prevent penetration of moisture into coils. The cast resin offers very good protection against adverse ambient conditions. These transformers can work without disruption of service at 100% humidity. Due to the high grade Insulation material, coil are non-hygroscopes & the Transformer can be switched or directly without pre drying even after a long period of services interruption. The insulation material used is glass fiber reinforced with epoxy resin of class 'F' which can with stand wide temperature variation transformer is practically non-inflammable by an electrical are special fire protection measures are not required. Resin cast coil transformer are better in respect of impulse Voltage with stand strength higher dynamic short circuit with stand strength as compared to oil immersed and conventional dry type transformer because of fiber glass reinforced epoxy encapsulation. The usual Input voltage 240V / 440V, and output of Lighting Transformer 110V / 220V/ 415V with added requirement of Customers. Transformer available to customized specifications & requirement are mostly used in thermal power plant, nuclear plants, shopping complex, Theater chemical plant, steel plant, hotels, housing societies. PRODUCT RANGE : 10KVA to 1000KVA Open & Enclosure type

    ...more
    Get Best Price
  • Isolation Transformer

    Isolation Transformer

    Request for Price

    APPLICATIONS : Telecommunication Systems, Microprocessors Equipments, CNC Machines, Scientific Equipments, Bio-medical Equipments Om make Isolation Transformer is a device which used to decouple two circuits. The load comes to the Isolation Transformer and to the input supply Isolation Transformer suppresses electrical noises which occur in transmission line. Any Isolation Transformer blocks transmission of DC signal form one circuit to other and allow AC signal to transmit. It also prevents interference cost by ground looping. Isolation Transformer is constructed with two isolated faraday shields between the primary and secondary winding. The use of two shields in the construction of the transformer diverts high frequency noise, which would they occur. The two shields provide more effective isolation of the primary and secondary circuits by also isolating their grounds. Ultra Isolation Transformer is used where high attenuation level is required like communication system a bio-medical equipment, micro-processor based product transmitter signaling equipment & scientific appearance & high Sensitive Equipment & add Uses project computers CNC machine Tele communication equipment due to Electrical noise spikes. Our all Transformer are CE approved. PRODUCT RANGE : Single Phase:- 100 VA to 100 KVA Three Phase:- 5KVA to 1000 KVA Operating Voltage :- 110V /230V / 415V Three Phase : 3 KVA to 500 KVA Dry Type

    ...more
    Get Best Price
  • Dynamic Braking Resistor

    Dynamic Braking Resistor

    Request for Price

    APPLICATIONS : Motor Control, VFD's, Oil Rig & Ship, Lifts & Elevators, Cranes & Winches, Conveyors AC variable frequency drives are commonly used with a general purpose induction motor to form a reliable variable speed drive system. Applications that require factor deceleration rates where Motor speed is exceeding the synchronous speed set up by the output frequency of the drives a braking resistor required. Breaking Resistor increase the Braking torque capacity of variable frequency drives. The resistor dissipates regenerated power to keep the bus voltage form exceeding the rated unit of the drives. Electrical drive system are being used more and more application as on ships, oil rigs, crane barges and vessels of all types for every type of powered application. Main propellers and bow thrusters driving winches and windlasses. Cranes, Lifts, conveyors and jacks, cable laying and tensioning. OM Make resistor are wide range resistor technologies and long experience in this field means that we have suitable braking resistor designed for all of the above applications. With braking powers form a few KW up to many MW (needed for example for some crane and main propulsion brakes) and cooling methods which include forced air and natural convection. We have standard products of all types. OM Make resistor use high grade ferritic alloy (feCrAl) or Nical - chromium resistor element. The resistance value changes uttle over the temperature range of element. Element temperature will typically not exceed them 600° degree centigrade. TYPES : Aluminum case encapsulated Punch grids Type (HRP grids) PRODUCT RANGE: Aluminum Case Type: 300 Watt to 4 Kw Punch Grid Type: 5 KW to 2000 KW air forced enclosure type

    ...more
    Get Best Price
  • detuned reactor

    detuned reactor

    Request for Price

    APPLICATIONS : Power Factor Panels, Furnace Panels, UPS, Fluroscent Lamps Om make reactors are designed to meet specific design criteria such as Q factor, inductance tolerances etc. series line reactors shall be designed for harmonic filtering service and for slowing the rate of rapid current charges. The reactors shall be UL component - recognized and shall be built to comply to UL 508 construction shall be of copper wire - wound on magnetic steel cores. Series line reactors shall be sized appropriately for the total connected load. Design maximum temperature rise for reactors shall be 115°c on bobbin wound and 155°c on form wound devices at rated circuit. Non-linear equipment generate harmonic as multiples of a fundamental frequency such as AC/DC motor speed controllers, are furnaces compact fluorescent lamps, uninterruptible power sources. As a result of this fact besides the fundamental frequency, 3rd, 5th, 7th, 9th, 13th, harmonic are generated. Specification of Harmonic filter Reactor (Detuned Reactor) Operating Voltage: 3 x 415/440V Supply Frequency: 50/60Hz Filtering Detuning Factor: 5.69%, 7%, 14% corresponding to tuning frequencies of 210Hz, 189Hz, and 134 Hz for the base of 50Hz. Tolerance of Inductance: ± 5% High Linearity: 1.8In (180% ) Over Load Capability: 150 % for 10 minute of Rated current & 200 % 10 Second of Rated current High Voltage Test: 4 KVA Temperature rise: 110° < maximum on full Load Maximum Audible Level at Two (2) Meters : Line / Load Application 76 dBa Standard: IS-5553-/EN-61558-2-20/IEC-60076-6 'CE' approved. PRODUCT RANGE : 5KVAr to 100 KVAr(Copper/Aluminum)

    ...more
    Get Best Price
  • Control Transformer

    Control Transformer

    Request for Price

    APPLICATIONS : Electrical Control Panels, PLC Power Supplies Om Make Control Transformers are designed for good regulation, upto 100% loading. Control Transformers are widely used in industrial applications such as electrical control panels or PLC power supplies (Industrial control equipment demand a momentary overload capacity of normal capacity). OM makes Control Transformers specification: High permeable iron core. High quality copper windings. Class I transformers. Excellent voltage regulation. High short time power. Vacuum impregnated varnish to ensure silent and moisture-immune operation. CE marking and compatibility with EN 61558 2-2. Manufactured under ISO 9000 quality management. PRODUCT RANGE : Input Voltage : 110V to 600V Output Voltage : 24V, 110V, 220V, 415, Single Phase : 100VA to 10KVA Three Phase : 3 KVA to 500 KVA Dry Type

    ...more
    Get Best Price
  • AC DRIVE APPLIED HARMONIC FILTER

    AC DRIVE APPLIED HARMONIC FILTER

    Request for Price

    APPLICATIONS : Power Factor, AC & DC Drive, VFD Panels The OMHG7 - drive applied harmonic filter is called an "OMHG7" shall contain a tuned circuit designed to remove harmonics generated within a power distribution system while improving the system power factor. The OMHG7 designed to minimize the possibility of system problems associated with power factor correction in the presence of harmonic distortion. The harmonic filter in combination with the adjustable frequency drive shall Meet all requirement specified in the 1992 edition of IEEE Standard 519 for individual and total harmonic Voltage and current distortion. The point of common Coupling (PCC) for all Voltage and current harmonic calculations and measurement shall be the input terminal of the harmonic filter. FEATURES: Limited to 7% Distortion (typical results of 5-6% TDP) Total demand Distortion. Superior performance at 100% and 50% Load. THD levels are consistently held Low. High Quality capacitor designed built and tested specifically for use in harmonically rich environments Easy installation: Fits easily in to VFD Motor control centers and ships ready to install. Uninterrupted operation: The drive continues to operate in the event of OMHG7 shutdown. In the operating range full Load to half load the power factor shall be 0.98 lagging to 0.95 leading. PRODUCT RANGE : 25 HP to 1000 HP

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Om industries is amongst the leading manufacturers & Exporters of Transformer and Load Bank for various Industries & Electrical Engineering. Our wide experience of last two decade in manufacturing and specializing in all types of Transformers, Reactors, Harmonic Filter for variable frequency Drives, Braking Resistor & Load Bank.
We at Om Industries are young and dynamic professionals who are totally committed to providing solutions to customer's satisfaction by providing them different type of solutions in power sector.
We the Om industries an ISO 9001-2008 certified company. Our all the products are 'CE' approved. Our Products are confirming standards of BS, IEC, IEEE & IS (National & International Standards).
We have established our goodwill in the field through our good quality, time bound delivery and technical support with competitive Rates.
Read More »

Contact Information

OM Industries

  • Shashank Bhosale
  • Plot No. D-4, Shirala MIDC Zone, Tal. Shirala, Dist. , 415 408. , , Sangli, Maharashtra
top