Standard : Based on VDE 0812
Nominal Voltage : 0.14 mm² = 350 V; >= 0.25 mm² = 500 V
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius : For flexible use 10 x cable ø
Test Voltage : Up to 0.25 mm² = 1200 V. From 0.34 mm² = 2000 V
Breakdown Voltage : Up to 0.25 mm² = 2400 V. From 0.34 mm² = 4000 V
Cable Construction
We are offering shielded cable.
Constuction conductor :
annealed copper wires according to class 1 or 2 or 5 of bs en 60228
insulation : pvc types ti51 according to bs en 50290-2-21
pairs - twisted
identification pairs : blue & white. Blue cores indicate pair identification.
assembly : concentric layers
outer sheath : pvc type tm51 according to bs en 50290-2-22
marking : rr kabel n x m x csa 300500 v pas 5308-part 2
application : pas 5308-2 design guidelines
standards : ec 60332-1 flame retardant
shielded cables are used in security systems as it provides protection from power frequency and radio frequency interference, thus, reducing the number of false alarms being generated. For its optimum use it necessary to keep the data or signal cables physically separated by at least 3 inches (75 mm) from 'heavy' power circuits which are in parallel.