Backed by a team of highly skilled engineers, Kant Plastology engaged in providing a wide range of VICAT SOFTENING POINT APPARATUS. The compact and elegant look of apparatus contains high efficient S.S. 304 tubular heating system for appropriate rate of rise of heat and stirrer motor to create uniform heating in test chamber. The offered apparatus has highly precise temperature control through micro processor based double display digital PID controller. Kant Plastology procures accurate weight, rigid test assembly, test needle & calibrated Dial gauge to conduct the test.
Specification
Backed by a team of highly skilled engineers, Kant Plastology engaged in providing a wide range of VICAT SOFTENING POINT APPARATUS. The compact and elegant look of apparatus contains high efficient S.S. 304 tubular heating system for appropriate rate of rise of heat and stirrer motor to create uniform heating in test chamber. The offered apparatus has highly precise temperature control through micro processor based double display digital PID controller. Kant Plastology procures accurate weight, rigid test assembly, test needle & calibrated Dial gauge to conduct the test.
Specification
Load cell- dual loadcell of 's type' with different capacity can be connected to single controller
load cell unit- kgcmâ² n mpa
cross head travel- 1000mm
resolution of displ- 0.01mm
speed- 5 to 500mmminute
speed control- through frequency controlled a.c. Drive
power supply- 230v ac, 1 phase, 50 hz
Load cell- dual loadcell of 's type' with different capacity can be connected to single controller
load cell unit- kgcmâ² n mpa
cross head travel- 1000mm
resolution of displ- 0.01mm
speed- 5 to 500mmminute
speed control- through frequency controlled a.c. Drive
power supply- 230v ac, 1 phase, 50 hz
Load cell- single loadcell 's type'
load cell unit- kgcm²
cross head travel- 800mm
resolution of displ- 0.1mm
speed- 100mmminute or 300mmminute
power supply- 440v ac, 3 phase, 50 hz.
Load cell- single loadcell 's type'
load cell unit- kgcm²
cross head travel- 800mm
resolution of displ- 0.1mm
speed- 100mmminute or 300mmminute
power supply- 440v ac, 3 phase, 50 hz.
We are offering tear strength tester.
Reference standards- astm d1922, astm d1424, astm d689
type- 'elmendorf'
pendulum weight- 1600 gf
augment weight- 3200 gf, 6400 gf
scale- 100% of dead weight fixed on pendulum
reading accuracy- 1% fsd
material of construction- all major components of brass with polish or hard chrome
We are offering tear strength tester.
Reference standards- astm d1922, astm d1424, astm d689
type- 'elmendorf'
pendulum weight- 1600 gf
augment weight- 3200 gf, 6400 gf
scale- 100% of dead weight fixed on pendulum
reading accuracy- 1% fsd
material of construction- all major components of brass with polish or hard chrome
Max. Dia. Of Test SampleTest up to uPVC pipe Ø315mm
Kant Plastology pleased to offer and exclusive range of PIPE IMPACT TESTING MACHINE. The Impact test is usually applicable for uPVC Pipe and Fittings to determine the Impact strength of the same products. The Kant Plastology’s PIPE IMPACT TESTING MACHINE having robust construction, high precision machined parts with dimensional accuracy. The machine consist perfect machined 120°‘V’ block to accommodate the test specimen, operational ease dead weight release mechanism and friction free falling of dead weight.
Specification
Kant Plastology pleased to offer and exclusive range of PIPE IMPACT TESTING MACHINE. The Impact test is usually applicable for uPVC Pipe and Fittings to determine the Impact strength of the same products. The Kant Plastology’s PIPE IMPACT TESTING MACHINE having robust construction, high precision machined parts with dimensional accuracy. The machine consist perfect machined 120°‘V’ block to accommodate the test specimen, operational ease dead weight release mechanism and friction free falling of dead weight.
Specification
system status- Digital
Temperature controller- Micro processor based double display PID controller
Heating- Through high grade nichrome wire
Air circulation- -----------
Temperature range- Ambient to 950°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
Safety MCB- Available on electrical panel
system status- Digital
Temperature controller- Micro processor based double display PID controller
Heating- Through high grade nichrome wire
Air circulation- -----------
Temperature range- Ambient to 950°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
Safety MCB- Available on electrical panel
Reference standards- ASTM-1238, ISO-1133, IS-2530
Method- A- A
System status- Digital
Temperature controller- Micro processor based double display PID controller
Temperature range- Ambient to 300°C
Temperature resolution- 0.1°C
Accuracy- ± 0.1°C
Timer range- 0 - 999 second
Reference standards- ASTM-1238, ISO-1133, IS-2530
Method- A- A
System status- Digital
Temperature controller- Micro processor based double display PID controller
Temperature range- Ambient to 300°C
Temperature resolution- 0.1°C
Accuracy- ± 0.1°C
Timer range- 0 - 999 second
No. of stations- 03
No. of outlets- 09
Unit of pressure- Kgcm² BAR PSI
Pressure range- Up to 99.99 Kgcm²
Pressure resolution- 0.01 Kgcm²
Time range- 999.59 Hours
Time resolution- 1 Minute
Material of construction for hydraulic circuit- Pressure pipe & tube fittings are of S.S. 304
No. of stations- 03
No. of outlets- 09
Unit of pressure- Kgcm² BAR PSI
Pressure range- Up to 99.99 Kgcm²
Pressure resolution- 0.01 Kgcm²
Time range- 999.59 Hours
Time resolution- 1 Minute
Material of construction for hydraulic circuit- Pressure pipe & tube fittings are of S.S. 304
Being a renowned manufacturer of the testing machinery Kant Plastology bring forward an amazing assortment of HYDROSTATIC PRESSURE TESTING MACHINE. The offered machine is manufactured under strict supervision of highly qualified professional who has keen knowledge about base fundamentals and test procedure. The machine is manufactured with modernize technology and prime grade material. In order to ensure quality, the entire range is rigorously tested upon a series of parameters. The offered machine is very user friendly and operational ease. Kant Plastology offers the entire range in various customize specification as per requirement.
Specification
Being a renowned manufacturer of the testing machinery Kant Plastology bring forward an amazing assortment of HYDROSTATIC PRESSURE TESTING MACHINE. The offered machine is manufactured under strict supervision of highly qualified professional who has keen knowledge about base fundamentals and test procedure. The machine is manufactured with modernize technology and prime grade material. In order to ensure quality, the entire range is rigorously tested upon a series of parameters. The offered machine is very user friendly and operational ease. Kant Plastology offers the entire range in various customize specification as per requirement.
Specification
system status- Digital
Model orientation- Vertical
Temperature controller- Micro processor based double display PID controller
Cooling- Through specially designed high efficient cooling system
Air circulation- Through blower fitted at the back side
Temperature range- Ambient to 80.0°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
system status- Digital
Model orientation- Vertical
Temperature controller- Micro processor based double display PID controller
Cooling- Through specially designed high efficient cooling system
Air circulation- Through blower fitted at the back side
Temperature range- Ambient to 80.0°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
Temperature controller- Micro processor based double display PID controller
Heating- Through high grade nichrome wire placed in the ribs of sides and bottom for uniformity
Air circulation- Through aluminum blower fitted at the top at the back
Temperature range- Ambient to 250°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
Safety MCB- Available on electrical panel
Smoke ventilation- Installed on top of both sides
Insulation- 70mm Thick Glasswool
Temperature controller- Micro processor based double display PID controller
Heating- Through high grade nichrome wire placed in the ribs of sides and bottom for uniformity
Air circulation- Through aluminum blower fitted at the top at the back
Temperature range- Ambient to 250°C
Temperature least count- 0.1°C
Accuracy- ± 0.5°C
Timer- Micro processor based double display digital timer (Optional)
Timer range- 999.9 Seconds, Minutes or Hours
Safety MCB- Available on electrical panel
Smoke ventilation- Installed on top of both sides
Insulation- 70mm Thick Glasswool
We are offering hdt test apparatus.
Temperature range- ambient to 120°c
temperature least count- 0.1°c
temperature accuracy- ± 0.5°c
temperature ramp- 50°chr & 120°chr
cooling- manually
specimen thickness- 3 – 13 mm
span length- 100mm (others optional)
fiber stress- 0.45mpa, 1.8mpa, 8 mpa (others optional)
displacement sensing- analog dial gauge
displacement range- 0.00 – 10.00
We are offering hdt test apparatus.
Temperature range- ambient to 120°c
temperature least count- 0.1°c
temperature accuracy- ± 0.5°c
temperature ramp- 50°chr & 120°chr
cooling- manually
specimen thickness- 3 – 13 mm
span length- 100mm (others optional)
fiber stress- 0.45mpa, 1.8mpa, 8 mpa (others optional)
displacement sensing- analog dial gauge
displacement range- 0.00 – 10.00
EMISSION FLOW VARIATION TEST APPARATUS is widely used to determine the Emission flow rate of Emitters and Emitting pipe. Kant Plastology feel immensely pleased to offer an exclusive gamut of EMISSION FLOW VARIATION TEST APPARATUS. This apparatus is manufactured by utilizing optimum quality raw material and advance technology by our adroit professionals. The apparatus has precise pressure control on fluid passes through test sample. This apparatus reduce the time and human effort due to common test sample adaptor for 12mm, 16mm & 20mm Emitting Pipe and easy tray sliding arrangement to measure the exact emission flow. Digital timer with auto pump-off function at set time feature is help to determine the accurate test results. Very ease maintenance due to simple mechanism of entire test assembly.
Specification
EMISSION FLOW VARIATION TEST APPARATUS is widely used to determine the Emission flow rate of Emitters and Emitting pipe. Kant Plastology feel immensely pleased to offer an exclusive gamut of EMISSION FLOW VARIATION TEST APPARATUS. This apparatus is manufactured by utilizing optimum quality raw material and advance technology by our adroit professionals. The apparatus has precise pressure control on fluid passes through test sample. This apparatus reduce the time and human effort due to common test sample adaptor for 12mm, 16mm & 20mm Emitting Pipe and easy tray sliding arrangement to measure the exact emission flow. Digital timer with auto pump-off function at set time feature is help to determine the accurate test results. Very ease maintenance due to simple mechanism of entire test assembly.
Specification
We are offering emission flow test apparatus.
System status- digital
model- rigid floor standing model
sample size- can be test minimum 25 test sample at a time
tank- s. S. 304 tank fitted at bottom of equipment of capacity 250 ltr.
Filter- 10micron filter inserted at the inlet of pump
pressure source- pressure should be developed through high pressure pump of reputed make
working pressure- 1.00kgcm² bar to 4.50kgcm² bar
accuracy- ± 0.05kgcm² bar
We are offering emission flow test apparatus.
System status- digital
model- rigid floor standing model
sample size- can be test minimum 25 test sample at a time
tank- s. S. 304 tank fitted at bottom of equipment of capacity 250 ltr.
Filter- 10micron filter inserted at the inlet of pump
pressure source- pressure should be developed through high pressure pump of reputed make
working pressure- 1.00kgcm² bar to 4.50kgcm² bar
accuracy- ± 0.05kgcm² bar
System status- Digital
Load cell- High sensitive flat bar type electronic loadcel
Weighing capacity- 300 Gms
Least count & accuracy- Least count 0.005gms and accuracy 0.5% of full scale
Result calculation- Automatic (Auto tare facility available at optional)
Display- LCD for readings & results
Weighing space- Sliding glass door on both sides with front glass cover
Weighing pan- Stainless steel
Accessories- Complete specific gravity tool kit, pan straddle & forceps
Power supply- 230V AC, 1 Phase, 50 Hz
System status- Digital
Load cell- High sensitive flat bar type electronic loadcel
Weighing capacity- 300 Gms
Least count & accuracy- Least count 0.005gms and accuracy 0.5% of full scale
Result calculation- Automatic (Auto tare facility available at optional)
Display- LCD for readings & results
Weighing space- Sliding glass door on both sides with front glass cover
Weighing pan- Stainless steel
Accessories- Complete specific gravity tool kit, pan straddle & forceps
Power supply- 230V AC, 1 Phase, 50 Hz
We are offering cooling chember.
Model orientation- horizontal vertical (optional)
temperature controller- micro processor based double display pid controller
cooling- through specially designed high efficient cooling system
air circulation- ---- ---
temperature range- ambient to -5.0°c
temperature least count- 0.1°c
accuracy- ± 0.5°c
timer- micro processor based double display digital timer (optional)
timer range- 999.9 seconds, minutes or hours.
We are offering cooling chember.
Model orientation- horizontal vertical (optional)
temperature controller- micro processor based double display pid controller
cooling- through specially designed high efficient cooling system
air circulation- ---- ---
temperature range- ambient to -5.0°c
temperature least count- 0.1°c
accuracy- ± 0.5°c
timer- micro processor based double display digital timer (optional)
timer range- 999.9 seconds, minutes or hours.
COOLING CHAMBER (CONDITIONING CHAMBER) is specially used for particular conditioning of the test specimen at 0°C or low temperature before conducting the test. Usaully this machine apply to condition the test specimen for Impact test of uPVC Pipe. Kant Plastology is engaged to supplying the extensive range of COOLING CHAMBER (DEEP FREEZER) with its prowess and accomplished engineering team. The proffer apparatus is design with good aesthetic, energy efficient and calculated cooling system with minimum cooling loss due to P.U.F. insulation and exactitude temperature control. Its internal Stainless Steel body procures the rust free usage of equipment. The utilization of apparatus is very user friendly.
Specification
COOLING CHAMBER (CONDITIONING CHAMBER) is specially used for particular conditioning of the test specimen at 0°C or low temperature before conducting the test. Usaully this machine apply to condition the test specimen for Impact test of uPVC Pipe. Kant Plastology is engaged to supplying the extensive range of COOLING CHAMBER (DEEP FREEZER) with its prowess and accomplished engineering team. The proffer apparatus is design with good aesthetic, energy efficient and calculated cooling system with minimum cooling loss due to P.U.F. insulation and exactitude temperature control. Its internal Stainless Steel body procures the rust free usage of equipment. The utilization of apparatus is very user friendly.
Specification
We arae offering cold water bath.
Cooling- high efficient cooling system designed by expert
wateroil circulation- through water circulation pump of ‘taro’ make
temperature range- ambient to 10°c
resolution- 0.1°c
accuracy- ± 0.5°c
insulation- 50mm thick puf.
We arae offering cold water bath.
Cooling- high efficient cooling system designed by expert
wateroil circulation- through water circulation pump of ‘taro’ make
temperature range- ambient to 10°c
resolution- 0.1°c
accuracy- ± 0.5°c
insulation- 50mm thick puf.
We are carbon dispersion tester.
Hot plate- 6- s.s. 316 to make thin film test sample
hot plate temperature control- blind regulator type thermostat
microscope- projection microscope
microscope illumination- 12w halogen lamp. Lamp slots provided for natural cooling of the illuminatorfor natural cooling of the illuminator
magnification- 10x & 20x
We are carbon dispersion tester.
Hot plate- 6- s.s. 316 to make thin film test sample
hot plate temperature control- blind regulator type thermostat
microscope- projection microscope
microscope illumination- 12w halogen lamp. Lamp slots provided for natural cooling of the illuminatorfor natural cooling of the illuminator
magnification- 10x & 20x
System status- Digital
Heating element- 1000 Watts heating element wounded on ceramic tube
Temperature controller- Micro processor based double display PID controller
Temperature range- Ambient to 950°C
Temperature least count- 1°C
Accuracy- ± 2°C
Furnace- With dual insulation such that the outer surface temperature does not exceed 50°C
Effective furnace size- 300mm in Length x Ø30mm
Pyrolyting chamber- Heat resistant quartz glass tube
System status- Digital
Heating element- 1000 Watts heating element wounded on ceramic tube
Temperature controller- Micro processor based double display PID controller
Temperature range- Ambient to 950°C
Temperature least count- 1°C
Accuracy- ± 2°C
Furnace- With dual insulation such that the outer surface temperature does not exceed 50°C
Effective furnace size- 300mm in Length x Ø30mm
Pyrolyting chamber- Heat resistant quartz glass tube
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Year of Establishment2004
No. of Employees51 - 100
Annual TurnoverRs. 2.5 to 5 Crore Approx.
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Established in year 2004, Kant Plastology is Retailer of Tensile Testing Machine, Universal Testing Machine, Melt Flow Index Tester, Hot Water Bath, Cold Water Bath, HDT Test Apparatus, Hot Air Oven, Cooling Chember, Opacity Tester, Pipe Impact Testing Machine from Ahmedabad, Gujarat.