AccessoriesMolded plug test leads, Pouch for test leads, 9121 (Shoulder Strap), Instruction Manual
Optional7121B (Simplified measurement probe)
kyoritsu rcd tester• custom microprocessor controlled for highest accuracy and reliability.• 3 leds for checking correct wiring status.• 0 and 180 degree phase angle switch permits quick tests and consistent readings.• digital read-out of tripping time.• constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.• large custom digital display readout.• visual indication of reversed phase and neutral wiring at socket.• designed to ip54 rating.• complies with iec 61557• test of a large kind of rcd's: standard, selective, ac and a (dc sensitive breakers).
kyoritsu rcd tester• custom microprocessor controlled for highest accuracy and reliability.• 3 leds for checking correct wiring status.• 0 and 180 degree phase angle switch permits quick tests and consistent readings.• digital read-out of tripping time.• constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.• large custom digital display readout.• visual indication of reversed phase and neutral wiring at socket.• designed to ip54 rating.• complies with iec 61557• test of a large kind of rcd's: standard, selective, ac and a (dc sensitive breakers).
• Simultaneous Power & Power quality measurements• Helpful support functions• Measurement with high accuracy• Remote monitoring on PC and Android device• Various Clamp Current Sensors• Energy consumption check on site• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
• Simultaneous Power & Power quality measurements• Helpful support functions• Measurement with high accuracy• Remote monitoring on PC and Android device• Various Clamp Current Sensors• Energy consumption check on site• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
KEW8031F is designed to check phase sequence.
Lamps provided on the unit will also tell you if a phase is open.
Can check a wide range of 3-phase power source from 110V to 600V.
Sealed against dust, the unit ensures trouble-free performance.
Small, Lightweight and portable.
Designed for maximum ease of operation and ruggedness.
No exposed metal parts, Safety features are incorporated including the instant push button switch operation.
KEW8031F is designed to check phase sequence.
Lamps provided on the unit will also tell you if a phase is open.
Can check a wide range of 3-phase power source from 110V to 600V.
Sealed against dust, the unit ensures trouble-free performance.
Small, Lightweight and portable.
Designed for maximum ease of operation and ruggedness.
No exposed metal parts, Safety features are incorporated including the instant push button switch operation.
• Senses AC voltage through insulation• Buzzer sounds and tip glows upon ac voltage detection• Powerful flashlight• Dual range (Hi/ Lo) sensitivity• Ready to use without power-on• Designed to meet IEC61010-1
• Senses AC voltage through insulation• Buzzer sounds and tip glows upon ac voltage detection• Powerful flashlight• Dual range (Hi/ Lo) sensitivity• Ready to use without power-on• Designed to meet IEC61010-1
Overload Protectionbetween E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Communication InterfaceModel 8212-USB Optical Adaptor
Model4106
Testing Method3-Point
Required Instant QuotationYes
FeaturesLarge Graphic Display with backlight for readings in poorly illuminated areas.
Weight900
Dimensions167(L) x 185(W) x 89(D) mm
High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the "KEW Report" software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
• Frequency Selector Switch to eliminate the effect of harmonics.• Three AC current ranges 20mA/200mA/200A.• Rotary switch for easy one finger power-on and range selection.• Resolution 0.01mA.
• Frequency Selector Switch to eliminate the effect of harmonics.• Three AC current ranges 20mA/200mA/200A.• Rotary switch for easy one finger power-on and range selection.• Resolution 0.01mA.
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.• True RMS enables an accurate measurement for distorted waveforms.• Measurement from mA up to AC 1000A• Frequency filter switch to eliminate the effect of the harmonics.• 2 way analogue output terminal• Resolution 0.1mA
• Large transformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.• True RMS enables an accurate measurement for distorted waveforms.• Measurement from mA up to AC 1000A• Frequency filter switch to eliminate the effect of the harmonics.• 2 way analogue output terminal• Resolution 0.1mA
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.• Frequency filter switch to eliminate the effect of harmonics.• Output terminal.• Resolution 0.1mA.
• Extra wide transformer jaws are best suited for clamping on all three or four wires (3phases) together for leakage current measurement.• Frequency filter switch to eliminate the effect of harmonics.• Output terminal.• Resolution 0.1mA.
• True RMS reading is an essential feature for accurate measurement.• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.• Set the DC current range to zero in one touch with the Zero Adjust function.
True RMS (Root Mean Square) Value Measurement
When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.
(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)
• True RMS reading is an essential feature for accurate measurement.• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.• Set the DC current range to zero in one touch with the Zero Adjust function.
True RMS (Root Mean Square) Value Measurement
When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.
(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)
• Flexible and light weight clamp sensor• Wide reading range up to 3000A• True RMS• MIN MAX function• Backlight LCD display• IEC 61010-1 (CAT IV 600V / CAT III 1000V)
• Flexible and light weight clamp sensor• Wide reading range up to 3000A• True RMS• MIN MAX function• Backlight LCD display• IEC 61010-1 (CAT IV 600V / CAT III 1000V)
• Ultra slim and lightweight Handy design• Ø33mm Tear Drop Jaw easy to use in tight places• 1000A AC Clamp Meter• DMM function ACV, DCV, Ω, Continuity Buzzer• Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V• Safety Standard IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V
• Ultra slim and lightweight Handy design• Ø33mm Tear Drop Jaw easy to use in tight places• 1000A AC Clamp Meter• DMM function ACV, DCV, Ω, Continuity Buzzer• Fuseless electronic protection on "Ω/Continuity Buzzer" up to 600V• Safety Standard IEC 61010-1, 61010-2-032 CAT IV 300V / CAT III 600V
• Ultra Slim and lightweight Handy design• 1000A AC Clamp Meter AC40/400/1000A Auto Range• Ø33mm Tear Drop Jaw easy to use in tight places• DMM function ACV, DCV, Ω, Continuity Buzzer• Fuseless electronic protection on up Ω/ to 600V• IEC61010-1 Safety StandardCAT III 600V (AC A) CAT III 300V / CAT II 600V (AC/DC V)
• Ultra Slim and lightweight Handy design• 1000A AC Clamp Meter AC40/400/1000A Auto Range• Ø33mm Tear Drop Jaw easy to use in tight places• DMM function ACV, DCV, Ω, Continuity Buzzer• Fuseless electronic protection on up Ω/ to 600V• IEC61010-1 Safety StandardCAT III 600V (AC A) CAT III 300V / CAT II 600V (AC/DC V)
• 1000A AC Clamp Meter, AC60/600/1000A Auto Range• True-RMS• Peak Hold for inrush current• 6000 counts display with Backlight• ø33mm Tear Drop shaped jaw easy to use in tight places• Double molding gives comfortable feeling• Safety standerd IEC 61010-1, CAT Ⅳ 300V/ CAT Ⅲ 600V
• 1000A AC Clamp Meter, AC60/600/1000A Auto Range• True-RMS• Peak Hold for inrush current• 6000 counts display with Backlight• ø33mm Tear Drop shaped jaw easy to use in tight places• Double molding gives comfortable feeling• Safety standerd IEC 61010-1, CAT Ⅳ 300V/ CAT Ⅲ 600V
• Fully Safety jaw• Ergonomic over-molded body gives convenient one-hand operation• Large easy-to-read display with 0.01A resolution• Accurate reading with True RMS 60/600/1000A auto-ranging• Long battery life• Safety Standard: IEC 61010-1 CAT IV 300V / CAT III 600V
• Fully Safety jaw• Ergonomic over-molded body gives convenient one-hand operation• Large easy-to-read display with 0.01A resolution• Accurate reading with True RMS 60/600/1000A auto-ranging• Long battery life• Safety Standard: IEC 61010-1 CAT IV 300V / CAT III 600V
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.• True RMS enables an accurate measurement.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.• True RMS enables an accurate measurement.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.• True RMS enables an accurate measurement.
• Designed to meet international safety standard IEC 61010-1 CAT IV 600V.• CAT IV Clamp Meters can measure the Voltage and Current in both every low and high power circuits.• Very useful for power distribution companies, power utilities and maintenance fields.• True RMS enables an accurate measurement.
• Smallest clamp meter capable of AC and DC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC/DC.• Auto-zero function to allow one touch zero adjustment
• Smallest clamp meter capable of AC and DC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC/DC.• Auto-zero function to allow one touch zero adjustment
• Smallest clamp meter capable of AC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC.• Auto-zero function to allow one touch zero adjustment.
• Smallest clamp meter capable of AC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC.• Auto-zero function to allow one touch zero adjustment.
• Smallest clamp meter capable of AC and DC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC/DC.• Auto-zero function to allow one touch zero adjustment
• Smallest clamp meter capable of AC and DC current measurements.• 300A auto ranging has minimum resolution of 0.01A AC/DC.• Auto-zero function to allow one touch zero adjustment
Secondary Business TypeManufacturer / Exporters / Service Providers / Wholesale Suppliers
Year of Establishment1940
Ownership TypeIndividual (Sole proprietorship)
GSTIN Number24AAGCK1062M1ZJ
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
As India evolves as a global manufacturing / services hub, Kyoritsu KEW India wants to play a significant role in it, and add power to the ‘SkillIndia’ movement. Test & Measurement, Multimeters, Clamp Meters, Insulation/ Continuity Testers, Earth Testers, LOOP/PFC/PSC Testers, Portable Appliance Testers, Multifunction Testers, RCD Testers, Power Quality Analyzer, Power Meters, Loggers, Sensors, Voltage Testers, Phase Indicators, Test Leads.