Mineral Water Bottling Plant Dealers in Gandhinagar Highway, Ahmedabad

(1 products available)
  • Mineral Water Bottling Plant

    Mineral Water Bottling Plant

    Get Price Quote

       CHLORINE DOSING SYSTEM Raw water may contain living micro-organisms and organics which are objection a Membrane as it may cause fouling to deteriorate the performance. Even water may contain ferrous which can be oxidized to ferric oxide which is settling down in storage tank. We have offered a Hypo chlorite dosing system for this purpose. About 3-4 ppm of sodium hypo chlorite solution is dosed in raw water storage tank. This reacts with water to form a hypo chlorite acids which acts as disinfecting agent. For this purpose one no. of HDPE hypo chlorite solution preparation tank along with one nos. of dosing pumps are provided. Required suction / discharge pipe work in pvc construction is provided with isolation valves. Dosage rate is adjusted as per the actual requirement, which may very on case to case basis    RAW WATER STORAGE TANK One Nos. of Raw water is required in for storage of chlorinated water having appropriate capacity. The tank is fitted with PVC pipe work & isolation valves and suitable type of level indicator.    PRESSURE SAND FILTER Raw Water is first filtered by filtration unit in series prior feeding R.O.Plant. Pressure Sand Filter Unit is provided for removal of suspended matters & turbidity from raw water. PSF Unit is a SS vertical Pressure Vessel. Internally, it is fitted with bottom collecting system. Uniform grades silica quartz sand is charged on the supporting media of pebbles and gravels. This unit is fitted with SS frontal pipe work and Multiport Valve externally. During service cycle water is passed in down ward direction through sand bed, thus entrapping suspended matter & turbid particles. Over a period of time, sand bed gets chocked due to suspended matters resulting higher pressure drop and lesser floe. At this stage filter bed need to be backwashed. When pressure drop across the sand bed increases beyond the specified limit (0.5 kg/cm²) or quality of filtered water determinates, whichever is earlier. Regeneration involves backwash & rinsing of Sand Bed as below. For backwashing service water is passed in reverse direction of service cycle to loosen the filtering media bed. Due to this, entrapped suspended matters get free and come out along with effluent water. Backwashing is continued for about 10- 15 minutes or till the effluent coming out is clear For Rinsing of Sand Bed: Service water is passed in down ward direction to settle down the sand bed. The effluent water is drained for about 5 minutes time to ensure all unclear water is drained down.    ANTI SCALENT DOSING  The hardness salts of calcium & magnesium are likely to be precipitated if concentration exceeds its solubility limit & it may faults the membranes resulting into scaling which ultimately leads to poor treated water quality from R.O. System. To prevent this a anti Scalent dosing (scale inhibitor) dosing system is provided. Normally a scale inhabitator like Perma care 191 or equivalent chemical is dosed in feed water. Dosage rate is 4-5 mg/liter. A HDPE chemical preparation tank with an electronics diaphragm type dosing pump is provided for this.  

    more..
Filter by Locality
top