Mechanical Drive steam turbines range from 100 HP to 25,000 HP, with speeds upto 6500 rpm, and are either condensing or non condensing types. Complete steam turbine compressor packages as well as separate mechanical drive steam turbines, which meet API requirements, are available.
Mechanical Drive steam turbines range from 100 HP to 25,000 HP, with speeds upto 6500 rpm, and are either condensing or non condensing types. Complete steam turbine compressor packages as well as separate mechanical drive steam turbines, which meet API requirements, are available.
The FLS package includes a hydraulically separate lubrication and lubricating oil dehydration system, a hydraulic fluid supply and conditioning system and common control console in a single. The fluid system package can mount separately from the steam turbine-generator or be installed integrally with the turbine base.
The FLS package includes a hydraulically separate lubrication and lubricating oil dehydration system, a hydraulic fluid supply and conditioning system and common control console in a single. The fluid system package can mount separately from the steam turbine-generator or be installed integrally with the turbine base.
Feed pump turbine drive packages are available from 100KW – 20MW. Complete steam turbine boiler feed pump packages are available, in addition to stand-alone steam turbine packages.
Feed pump turbine drive packages are available from 100KW – 20MW. Complete steam turbine boiler feed pump packages are available, in addition to stand-alone steam turbine packages.
The extraction condensing turbines are used when a constant pressure steam flow has to be extracted for process purposes. The constructional characteristics of these turbines are very similar to condensing turbines From the second admission valve chest it is possible to inject low pressure steam, available in the plant to supply the power required by the plant.
The extraction condensing turbines are used when a constant pressure steam flow has to be extracted for process purposes. The constructional characteristics of these turbines are very similar to condensing turbines From the second admission valve chest it is possible to inject low pressure steam, available in the plant to supply the power required by the plant.
Directly coupled steam turbines in combined cycle applications must provide the performance and flexibility required for integration with gas turbines and heat – recovery boilers. Packaged arrangements, when feasible, offer shorter delivery and installation time.
Directly coupled steam turbines in combined cycle applications must provide the performance and flexibility required for integration with gas turbines and heat – recovery boilers. Packaged arrangements, when feasible, offer shorter delivery and installation time.
Back pressure turbines can either be single stage or multi-stage which are often used in industrial plants, the turbine serves as a reducing station between boiler and the process steam header. These turbines are of extraction cum back pressure type.
Back pressure turbines can either be single stage or multi-stage which are often used in industrial plants, the turbine serves as a reducing station between boiler and the process steam header. These turbines are of extraction cum back pressure type.
The condensing turbines take high pressure steam, expand it in turbine nozzles and blades, and exhaust it to a condenser at lower than atmospheric pressure. It is principally used when power must be generated with minimum steam consumption. The condensing turbine may also have bleed points (uncontrolled extractions) to satisfy steam demands at medium intermediate pressures.
The condensing turbines take high pressure steam, expand it in turbine nozzles and blades, and exhaust it to a condenser at lower than atmospheric pressure. It is principally used when power must be generated with minimum steam consumption. The condensing turbine may also have bleed points (uncontrolled extractions) to satisfy steam demands at medium intermediate pressures.
The geared steam turbine-generator package ranges from 100 to 30,000 KW, 50 or 60 Hz and may be the economical solution customers are looking for. The package consist of an efficient, high speed steam turbine driving a gearbox connected to a four-pole, 50 or 60 Hz generator.
The geared steam turbine-generator package ranges from 100 to 30,000 KW, 50 or 60 Hz and may be the economical solution customers are looking for. The package consist of an efficient, high speed steam turbine driving a gearbox connected to a four-pole, 50 or 60 Hz generator.
CTMI offers highly reliable geothermal steam turbines generators sets. These steam turbines operate typically with saturated steam, which is provided from a geothermal source. Their unique features materials of construction lead to long-term, reliable operation in geothermal service.
CTMI offers highly reliable geothermal steam turbines generators sets. These steam turbines operate typically with saturated steam, which is provided from a geothermal source. Their unique features materials of construction lead to long-term, reliable operation in geothermal service.
Ctmi offers amonia based vapour turbines with percentage of amonia in the vapour as high as 99%, these turbines principally operating on kalina cycle offer high efficiency even in non condensing configurations.
Ctmi offers amonia based vapour turbines with percentage of amonia in the vapour as high as 99%, these turbines principally operating on kalina cycle offer high efficiency even in non condensing configurations.