Deltasoft Software
Request for Price
We are offering deltasoft software is a sophisticated electronic comparator, designed for accurate electronic measurement and inspection of specific dimensional tolerances, along with max. Min and range. Moreover, the deltasoft software is equipped with a 'program' function, which provides for convenient pre-setting of values, tolerance limits and calibration. In addition, all the buttons are soft-touch type, to facilitate easy operation. features
two probe input : a, b, a/2, b/2, and combinations
calibration and zero setting in one key operation
32 character back-lit alphanumeric display
measuring possible with, or without tolerance
measuring ranges of; + 5mm, + 0.5mm, + 0.05mm
led indicators for; 'within tolerance', 'rework' & 'reject' and relay output of the same
three least counts; 0.001mm, 0.0001mm, 0.00001mm
analogue output
pre-set value input available
rs 485 & rs232 output in ascii format for computer or gauge management
true inch / metric conversion
polarity selector for internal or external measurements
set configuration automatically memorized at switch off
tolerance can be set for individual probe
max min & range
details of operation
pgm : to enter the program mode to set measuring range, preset values and tolerance values, using selection keys, pressing pgm again will exit program mode
cal/mode : to toggle between calibration mode, program mode, and normal operating mode. In cal mode, it scrolls from am to am+p to tole to toli to am
unit/enter : to instantly switch between metric/inch readings. Enter key also used to accept each step of calibration.
tol/range : to establish the range of tolerance. Range key used to key in different ranges. It scrolls from r1 to r2 to r3 to r1 each time the key is pressed.
send/>(right arrow) : used to enter values. Done by shifting digits to the right one at a time.
clr/^(up arrow) : to enter values. Done by incrementing digits by 1 each time the key is pressed.
max : maximum of the probe measurement will be stored
range : difference of max and min is total range of measurement
a : to select probe a for calibration
b : to select probe b for calibration
led(yellow) : for quick indication that checked component requires 'rework' when led lights up
led(green) : for quick indication that checked component is 'ok' when led lights up
led(red) : for quick indication that checked component is a 'reject' when led lights up
screen : 2 lines of 16 characters each, alpha numeric lcd display, with backlight for easy viewing in all inspection conditions
min : minimum of the probe measurement will be stored
Country of Origin : India
Features : Two Probe Input: A, B, A/2, B/2, And Combinations,32 Character Back-lit Alphanumeric Display,Measuring Ranges Of +5mm, +0.5mm, +0.05mm,Three Least Counts: 0.001mm, 0.0001mm, 0.00001mm,Analog Output,RS 485 & RS232 Output In ASCII Format,True Inch/Metric Co
Usage : Electronic Measurement And Inspection Of Specific Dimensional Tolerances
Type : Electronic Comparator