Fire Point Apparatus Dealers (34 products available)

  • Cleaveland Flash Point & Fire Point Apparatus.

    Cleaveland Flash Point & Fire Point Apparatus.

    We are offering cleveland flash fire point apparatus

  • Fire Point Apparatus

    Fire Point Apparatus

    9,000 Per Piece

    1 Piece (MOQ)

    Weight : 20-30kg

    Voltage : 220V

    Automation : Automatic

    Warranty : 1yrs

    Pack Type : Box

    This apparatus is used for determination of flash point and fire point of petroleum products except fuel Oil with open cup flash below 80°C as per specification IP 36 and IS: 1448 ( P: 69) 1969. The apparatus consists of a cup, heating plate to specific dimension thermometer clip and test flame attachment with swivel joint for passing over test liquid surface in the prescribed manner, Heating is controlled by means of energy regulator fitted to the apparatus. Suitable for operation on 220 Volts 50 cycles AC Circuits. - Cleaveland flash point & fire point Apparatus, Electrical Heating with Energy Regulator Gas Test Jet - Cleaveland flash point & fire point Apparatus, Electrical Heating with Energy Regulator with oil wick Arrangement. - Cleaveland flash point & fire point Apparatus, Electrical Heating with Energy Regulator with Gas Jet & oil wick Arrangement – combined model - Cleaveland flash & fire point Apparatus voltage Varrier (Copper Coil) combine model - Cleaveland flash & fire point Apparatus voltage Varrier (Copper Coil) combine model with Digital Temp. Indicator - Thermometer IP 28C (-5°C to 400°C ) - Spare Cup with Handle - Spare Nichrome element - L.P.G. Test flame container with valve

    ...more
  • Flash & Fire Point Apparatus

    Flash & Fire Point Apparatus

    Automation Type: : Semi-Automatic

    Power (W): : 1000

    Weight (kg): : 17 kG

    Frequency (Hz): : 50 HZ

    Thermometer (deg. Celsius): : 400 DEG C

    We make sure that the transactions are made with utmost security and precision with us. We have made necessary arrangements to process transactions through mediums like cash and bank transfer. Well-established name in the domain, you can count on us for presenting extensive array of Flash & Fire Point Apparatus. Features Precision engineered High productivity Smooth operation

    ...more
  • Automatic Cleveland Flash Fire Point Apparatus

    Automatic Cleveland Flash Fire Point Apparatus

    Resolution : 0 .1°C

    Controller Accuracy : 0.5°C

    Flash Detection Accuracy : ±1°C

    Load : 1 Kw

    Operation on : 230V 50Hz, single phase. (Optional 110V 50 Hz, single phase.)

    For accurate and manual error free determination of flash points of fuels, lubricating oils, and homogenous liquids as per ASTMD92, method A & B. Test parameters are set via keypad,with digital display of set and process temperature   Standard Features Automatic Flash point detection. Automatic Barometric pressure correction. Automatic flash point search mode for unknown samples . User set-able heating and flashing profile. Automatic or user set-able stirrer speed setting and control. Automatic heating profile setting depending on initial sample temperature and expected flash point. Automatic cutoff at 30°C beyond expected flash point or at max. temperature limit set by the user. 2 Preset test Modes as per ASTM Method A & B . 16 x 4 Line Back Lit Alpha numeric display . In-bulit Key pad for settings & data entry. Audio visual indication of end of test and Alarms. Over temperature safety cutoff and alarm. Last reading stored until report is printed or next test is initiated. Serial Printer interface for Automatic printing of test report at a press of a        button. Ensures minimum power consumption by design thereby reducing operation cost. Electrical ignition instead of gas (Optional)   Accessories/ Spares 11010-11 Energy Regulator 11010-12 Voltage Variac 11010-13 Digital Controller 11010-14 Reducing Socket cum Flame Regulator xxxxx-xx IP-28C Thermometer 11010-16 Test Cup 11010-17 Temperature Sensor (pt-100) 11010-18 Thermometer Holder 11010-19 Heating Coil 11010-20 Gas Ignition System 11010-21 Electrical Ignition System (automatic model only) 11010-22 Calibration Certificate

    ...more
  • Cleaveland Fire Point Apparatus

    Cleaveland Fire Point Apparatus

    Type : Cleaveland Flash

    Power : 0.25 To 2 kw

    Brand Name : Steco

    Application : Petroleum Testing

    Material : Steel

    ...more
  • Flash Point and Fire Point Apparatus

    Flash Point and Fire Point Apparatus

    3,500 Per Piece

    Brand Name : ALPHA CHEM

    Model Number : ALPHA CHEM-209

    Flash point and fire point apparatus : for determining the flash point of fuel oils and lubricating oil, bitumen other than cutback bitumen and suspension of solids in liquids, having a flash point above 49°c. Flash & fire point apparatus used for determining the flash point of fuel oils and lubricating oil, bitumen other than cutback bitumen and suspension of solids in liquids, having a flash point above 49°c. The apparatus consists of brass test cup with handle removable cup cover with the spring operated rotated shutter having oil test jet flame device, stirrer with flexible shaft. The assembly rests in air bath which is covered with dome shape metal top. The cup assembly is positioned in a cast iron air bath, fitted with a chrome plated brass top having electric heater with temperature controller. Suitable for operation on 220v, 1ph, 50hz ac supply.

    ...more
  • CLEAVELAND FLASH & FIRE POINT APPARATUS

    CLEAVELAND FLASH & FIRE POINT APPARATUS

    Condition : New

    Power Source : Electric

    Application : Household, industrial, Laboratory

    Material : Steel

    Finish : Polished

    CLEAVELAND FLASH & FIRE POINT APPARATUS (IP 36/57, IS 1448 (P:69)1969 & ASTM-D-92-67) The appartus is used for determination of Flash Point & Fire Point of Petrolrum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448(P:69) 1969 and ASTM-D-92-67. The apparatus consists of a cup heating plate to specific dimensions thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner, heater is controlled by means of different types of regulators fitted to the apparatus suitable for operation on 220 Volts AC mains. about Optional Accessories: IMC-441 Cleaveland Flash Point Apparatus electric heated with energy regulator control. IMC-441B Same as above but oil wick arrangement. IMC-441BB Cleaveland Flash Point Apparatus same as per IMC-441 with concealed Hot plate. IMC-441A Cleaveland Flash Point Apparatus electric heated with voltage varric copper coil type. IMC-441AA Cleaveland Flash Point Apparatus same as per IMC-441BB with voltage copper coil type.

    ...more
  • Cleveland Flash Point and Fire Point Apparatus

    Cleveland Flash Point and Fire Point Apparatus

    22,000 Per Piece

    1 Piece(s) (MOQ)

    Power : 500 Watts

    Frequency : 50 Hz

    Voltage : 220 V

    Made in : India

    Material : Mild Steel

    Accuracy : Up to 2 mm

    ...more
  • Cleveland Flash & Fire Point Apparatus

    Cleveland Flash & Fire Point Apparatus

    1 Piece (MOQ)

    Country of Origin : India

    Type : Automatic

    Material : Stainless Steel

    Shape : Vertical

    Certification : CE Certified

    Color : Blue

    Voltage : 220V

    Surface Finishing : Polished

    Warranty : 1 Year

    Usage : Laboratory Use, Industrial Use

    ...more
  • Flash & Fire Point Apparatus

    Flash & Fire Point Apparatus

    Driven Type : Electric

    Color : Metallic, Silver

    Application : Industrial

    Surface Finshing : Polished

    Resistivity : Rust Resistant

    Material : Metal

    Flash & Fire Point Apparatus is used for determining the flash point and fire point of different petroleum products except fuel oil that has open cup flash below 80oC. It is suitable for operation on 220 Volts, 50 cycles ad AC Circuits. Our Flash & Fire Point Apparatus consists of a cup, thermometer clip, heating plate to specific dimension, and a test flame attachment along with swivel joint. The heating is controlled with the help of an energy regulator fitted to the apparatus. Avail from us, our Flash & Fire Point Apparatus at competitive rates.

    ...more
  • Fire Point Apparatus

    Fire Point Apparatus

    We manufacture and supply premium quality Fire Point Apparatus that is made as per specification IP 3657, IS 1448(P:69) 1969 and ASTM-D-92-67. Used For :- Determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C Package Includes :- Cup heating plateThermometer clipTest flame attachment with swivel jointTemperature control heater Power Consumption :- Operates on 220 Volts AC mains Optional Accessories :- IMC-441 Cleaveland Flash Point Apparatus electric heated with energy regulator control.IMC-441B Same as above but oil wick arrangement.IMC-441BB Cleaveland Flash Point Apparatus same as per IMC-441 with concealed Hot plate.IMC-441A Cleaveland Flash Point Apparatus electric heated with voltage varric copper coil type.IMC-441AA Cleaveland Flash Point Apparatus same as per IMC-441BB with voltage copper coil type.

    ...more
  • Cleaveland Flash and Fire Point Apparatus

    Cleaveland Flash and Fire Point Apparatus

    For determination of (OPEN CUP) flash & fire points of petroleum and other liquids except fuel oils and those materials having an open cup flash below 79° C (175° F). The apparatus consists of a machined brass oil cup with handle. This rests on a heating plate which is covered with insulated board to prevent heat loss. There is a thermometer clip and test flame arrangement with swivel joint for passing over liquid in the prescribed manner. Electrically operated heater is provided with temperature regulating device. Suitable to work on 220 V AC, 50 HZ mains.

    ...more
  • PENSKY MARTENS FLASH POINT AND FIRE POINT APPARATUS

    PENSKY MARTENS FLASH POINT AND FIRE POINT APPARATUS

    This is widely used for determination of closed cup Flash Point of Fuel Oil, cut back asphalts, other viscous material and suspension of solids having a flash point about 490C(1200F).The apparatus serve the purpose according to IP 34, ASTM-D-93-58T, IS-1448(P:I) 1960(P:21) and IS 1209/1958 method B. The apparatus consists of Brass Test cup with handle removable cup cover with spring operated rotating shutter having pilot jet, stirrer with flexible shaft. The assembly rests in Air Bath which is covered with Dome shape metal top. The cup is fitted with insulated handle and locking arrangement near cup plunge. The assembly rests on a round shaped heater with different temperature regulation system suitable for operation on 220 Volts AC mains. SERVICE REQUIRED:- • Diesel OR 20w/40 Lubricating Oil Sample. • Matchbox. • Ghee. • Suitable Table space to mount apparatus. • 15 Amps. Single Phase Electrical Connection

    ...more
  • Fire Point Apparatus

    Fire Point Apparatus

    Cleaveland Flash Point & Fire Point Apparatus Electrical Heating with Energy Regulator Gas Jet Point. With Oil Wick ArrangementGas Jet & Oil wick arrangement Combined ModelCleaveland Flash & Fire Point Apparatus Voltage Variac (Copper Coil) Comb. ModelWith Digital Temperature IndicatorThermometer IP 28C (-5 deg. C to 400 deg. C)Polish Wooden CaseSpare Cup With HandleSpare Nichrome ElementL.P.G. Test Flame Container with Valve

    ...more
  • Fire Point Apparatus

    Fire Point Apparatus

    Product Description     Flash & Fire Point Apparatus used for determining the flash point of fuel oils and lubricating oil, bitumen other than cutback bitumen and suspension of solids in liquids, having a flash point above 49°C. For determination of (OPEN CUP) flash & fire points of petroleum products and other liquids except fuel oils and those materials having an open cup flash below 79° C (175° F) as per specification IP 36 and IS 1448.The apparatus consists of brass test cup with handle removable cup cover with the spring operated rotated shutter having oil test jet flame device, stirrer with flexible shaft. The assembly rests in Air Bath which is covered with dome shape metal top. The cup assembly is positioned in a cast iron air bath, fitted with a chrome plated brass top having electric heater with temperature controller. Suitable for operation on 220V, 1Ph, 50Hz AC Supply.   Suitable for Operation on 220V, Single Phase, 50Hz, AC Supply

    ...more
  • Cleveland Flash Fire Point

    Cleveland Flash Fire Point

    This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67. The apparatus consists of a cup, heating plate, and thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner; heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase. Cleveland Flash Point Apparatus electric heated with voltage carriac copper coil type. Thermometer IP 28C Range -6 to +400C Polished carrying wood case. Spare cup with handle only.

    ...more
  • Cleaveland Flash and Fire Point Apparatus

    Cleaveland Flash and Fire Point Apparatus

    This apparatus is used for determination of Flash Point & Fire Point of Petroleum products except fuel oil with open flash 800C as per specification IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67. General Descripation & Specifications : The apparatus consists of a cup, heating plate, thermometer clip and test flame attachment with swivel joint for passing over liquid surface in the prescribed manner, heater is controlled by means of Energy Regulator for operation on 230 volts, 50Hz, AC single phase. Optional Accesories : Cleaveland Flash Point Apparatus electric heated with voltage carriac copper coil type. Thermometer IP 28C Range -6 to +400C Polished carrying wood case. Spare cup with handle only.

    ...more
  • Fire Manual Call Point

    Fire Manual Call Point

    550 Per Piece

    20 Piece (MOQ)

    Brand Name : Fire

    Weight : 2.4 Kg

    Color : Red

    Voltage : 230 V

    Type : Manual

    Usage/Application : Fire Alarm System

    Shape : Rectangle

    Material : ABD Plastic

    Frequency : 50 Hz

    ...more
  • Fire Point Apparatus

    Fire Point Apparatus

    For determination of (OPEN CUP) flash & fire points of petroleum and other liquids except fuel oils and those materials having an open cup flash below 79° C (175° F). The apparatus consists of a machined brass oil cup with handle. This rests on a heating plate which is covered with insulated board to prevent heat loss. There is a thermometer clip and test flame arrangement with swivel joint for passing over liquid in the prescribed manner. Electrically operated heater is provided with temperature regulating device. Suitable to work on 220 V AC, 50 HZ mains.

    ...more
  • Flash Point & Fire Point Apparatus

    Flash Point & Fire Point Apparatus

    To minimize the human interference, we have incorporated automated systems and thus, we are capable of maintaining high standards in terms of quality, space or delivery of the products. We inspect each and every element of the raw material that that helps us in delivering qualitative products. Under the vigil supervision of professionals, we conduct quality examinations to ensure that the range is free from defects.   Note : BHI-OPT-018 FLASH POINT & FIRE POINT APPARATUS

    ...more
Filter by City