esponse
Standard/Quick
Coverage
Produce a hemispherical water distribution pattern below the deflector.
Installation
Upright installed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency
Temp. Rating
135“F/57°C,155°F/68°C, 175°F/79°C, 200"F/93'C
Maximum ServicePressure
175psig/1.2MPa(12bar)
Listings and Approvals
UL
Finishes
Natural brass, chrome plate
esponse
Standard/Quick
Coverage
Produce a hemispherical water distribution pattern below the deflector.
Installation
Upright installed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency
Temp. Rating
135“F/57°C,155°F/68°C, 175°F/79°C, 200"F/93'C
Maximum ServicePressure
175psig/1.2MPa(12bar)
Listings and Approvals
UL
Finishes
Natural brass, chrome plate
Standard response spray sprinklers are intended for use in the sprinkler systems in accordance with the standard installation rules recognized by the applicable listing or approval agency. They are available in pendent, upright, recessed, horizontal sidewall styles. Quick response spray sprinklers are designed with a 3 mm glass—bulb to react quicker at the specified temperature. They are available in pendent, upright, horizontal sidewall styles. During a fire conditions, the thermal-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the button and spring seal assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Standard and quick respondent are designed for use in a wild range of applications including office buildings, libraries, hotels, restaurants, banks, band shells, theaters, factories and storehouses.
Standard response spray sprinklers are intended for use in the sprinkler systems in accordance with the standard installation rules recognized by the applicable listing or approval agency. They are available in pendent, upright, recessed, horizontal sidewall styles. Quick response spray sprinklers are designed with a 3 mm glass—bulb to react quicker at the specified temperature. They are available in pendent, upright, horizontal sidewall styles. During a fire conditions, the thermal-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the button and spring seal assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Standard and quick respondent are designed for use in a wild range of applications including office buildings, libraries, hotels, restaurants, banks, band shells, theaters, factories and storehouses.
CoverageWater discharge is directed primarily outward and downward In a quarter spherical pattern. a portion of the spray is also directed towards the backwall.
InstallationDesigned forrnstallation along wall or the side of a beam just beneath a smooth ceiling.
Slide plates red epoxy powder nishing.
Automatic hose reel has integrated automatic stop
valve which will open after 2 revolution of the reel.
Threaded Inlet connection.
Outlet connection for hose can be rotate for left and right direction.
Waterways made from non ferrous metals which ensure
corrosion free.
Maximum working pressure 12bar, test pressure 18bar.
Side plates available in stainless steel.
Slide plates red epoxy powder nishing.
Automatic hose reel has integrated automatic stop
valve which will open after 2 revolution of the reel.
Threaded Inlet connection.
Outlet connection for hose can be rotate for left and right direction.
Waterways made from non ferrous metals which ensure
corrosion free.
Maximum working pressure 12bar, test pressure 18bar.
Side plates available in stainless steel.
Fire Hose is constructed using best quality 100% Polyester Yarn practically free from Dirts, Knots,Lumps, lrregularities of the yarn and other visible defects. Lighter in weight, Compact, Flexible and Stronger in performance, Manufactured on Imported Plant & Machinery and is inside Seamless Rubberlined with leakproof and Non - Percolating lining, Ultra White appearance & Smooth Finish
Fire Hose is constructed using best quality 100% Polyester Yarn practically free from Dirts, Knots,Lumps, lrregularities of the yarn and other visible defects. Lighter in weight, Compact, Flexible and Stronger in performance, Manufactured on Imported Plant & Machinery and is inside Seamless Rubberlined with leakproof and Non - Percolating lining, Ultra White appearance & Smooth Finish
The zephyr analogue addressable panels are a powerful yet user-friendly series of control panels. They are designed to a high standard with LPCB approval to EN54, parts 2 & 4. Each panel in this modular series has considerable processing ability but is easy to install, programme and operate. This is supported by comprehensive support documentation. Panels are housed enclosures and are finished in harwearing epoxy paint.
STANDARD FEATURES
1-4 loop addressable fire alarm panel (each with a 126 device capacity)
LPCB Approved to EN54 parts 2 El 4
Devices can be grouped into 32 zones
Network up to 15 panels (giving a total of 60 loops)
500mA output per loop with highly stable voltage platform, even under mains-failed conditions
Powerful processing and extensive panel and loop I/O capability
User-friendly controls (enabled by key switch) and a clear, unambiguous screen [4 x 20 character LCD display)
The zephyr analogue addressable panels are a powerful yet user-friendly series of control panels. They are designed to a high standard with LPCB approval to EN54, parts 2 & 4. Each panel in this modular series has considerable processing ability but is easy to install, programme and operate. This is supported by comprehensive support documentation. Panels are housed enclosures and are finished in harwearing epoxy paint.
STANDARD FEATURES
1-4 loop addressable fire alarm panel (each with a 126 device capacity)
LPCB Approved to EN54 parts 2 El 4
Devices can be grouped into 32 zones
Network up to 15 panels (giving a total of 60 loops)
500mA output per loop with highly stable voltage platform, even under mains-failed conditions
Powerful processing and extensive panel and loop I/O capability
User-friendly controls (enabled by key switch) and a clear, unambiguous screen [4 x 20 character LCD display)
STANDARD FEATURES
Automatic Horizontal oscillation when water pass through monitor
Oscillation angle adjustable in 15 steps from 300 deg to 120 deg
Oscillation angle adjustable from 2 to 10 per sec
Manual movement 360 deg horizontal
4” ANSI inlet flange in gun metal RF
3” Stainless steel waterway
Nozzle and flange in gun metal
Oscillating mechanism: Aluminium
Cover: Mild Steel
STANDARD FEATURES
Automatic Horizontal oscillation when water pass through monitor
Oscillation angle adjustable in 15 steps from 300 deg to 120 deg
Oscillation angle adjustable from 2 to 10 per sec
Manual movement 360 deg horizontal
4” ANSI inlet flange in gun metal RF
3” Stainless steel waterway
Nozzle and flange in gun metal
Oscillating mechanism: Aluminium
Cover: Mild Steel