Water Level Controller
10 1000 Pieces (MOQ)
We are manufacturer ofSemi/Fully Automatic Pump Controller or water level controller for your home and industry. It continuously monitors the liquid level of the overhead tank and reservoir.The Automatic pump controller controls the water pumps and turns it ON and OFF with respect to the level in the water tank. This auto-switching feature saves manpower. Hence no need to operate manually. There for no wastage of water, stop tank overflow, save water & electricity bill. Features: Auto start &stop according the tank level Digital display to show level (in percentage) Audio alarm on full tank Push button to reset buzzer Maintenance free, high quality magneticfloat sensor It is suitable for 1/ 3 phase motor.
Size : 65x105x37
Application : Submersible Pump Automation (Single And Three Phase)
Input Voltage : 230volt Input
Type : Automatic
Features : Fully Automatic Operation
...moreThree Phase DOL Control Panel 5-20 HP
1 1000 Pieces (MOQ)
Three Phase Motor Starter Control Panel are very much suitable in domestic, agriculture for irrigation and industrial purposes. They can be operated in a voltage range from 170-470 VAC. 01 to 100 HP Starters developed with micro controller Digital overload relay for monitoring /controlling for more protection of motor and PMC (Pre Magnetic Contractor) for instant switching. PMC is a modified concept of contractor with benefits of cost effectiveness & free from problems of Chattering & Coil burning. In digital overload relay, you can program the voltage range as well as current range within which the motor has to be operated. Starter will trip the motor if supply parameters go out of range. It can be operated in AUTO or MANUAL modes. When the AUTO mode is once selected, it automatically starts the motor whenever the power resumes in all three phases in healthy condition. While in the manual mode, one can manually start and stop the motor instantly with the help of separate smooth push buttons. The starter is having smart digital ampere, volt and hour meter. Features : Over load Protection (Programmable) Under Load Protection (Programmable) Under voltage protection (Programmable) Over voltage protection (Programmable) Single phase preventer Reverse phase protection Unbalance voltage protection Auto/manual mode selector switch Inbuilt MCB /MCCB to extra protection Hour meter to show the total time of run Digital Amp. & volt meter inbuilt Auto switch inbuilt with Start delay time Wide voltage range - 170 - 450 VAC Fabricated with powder coated G.I. sheet Continuous running capacity - 100 + Hrs
Brand Name : Subtech
Automation Grade : Fully Automatic
Voltage : 440V
Phase : Three Phase
Usage/Application : Industrial Area
Rated Current : 63A to 630A
...moreSump Pump Control Panels
1 1000 Pieces (MOQ)
Sump Pump Control Panel may be designed to control one pump or multiple pumps (Duty / Standby, Lead / LaG, etc.) as needed. Sump pump include power components to control the pump motor, motor and pump sensors to protect the motor and pump and field sensors to monitor the process and control pump operation. Features Automation Sump Pump Control Panel Automation of Sewage Pump, of Sewage Tank. Necessary safety features like Overload Protection Under Load Protection (Dry Run), Under/Over Voltage Protection, Single Phase Preventer & Reverse Phase Protection Operate Two or Three Pump simultaneously or alternatively
Application : To control the pump motor, motor and pump sensors,Industrial
Condition : New
...moreSUBTECH Single Phase Prepaid Electricity Sub - Meter 220V 50Hz 40A
10 1000 Pieces (MOQ)
Features: Single/Three Phase User can purchase electricity through Smart Card or RS485 (PC/Laptop) Customer information management Warning & cut off when electricity insuffciency (Adjustable) Store the Data of Last 10 Years Automatic switch off power when overload (Adjustable) LCD Display Contents: Voltage, Ampere, Frequency, Balance Money & Total Consumption (kWh)
Size : Standard
Material : Plastic
Application : Industrial, Residential, Hostels PG
Color : Grey, White
Voltage : 220V
Driven Type : Electric
Feature : Accuracy
Warranty : 3 Years
Automaton Grade : Automatic
Color : Grey
...moreStreet Light Control Panel
1 500 Pieces (MOQ)
It is used to operate street lights automatically according to the set program to save huge amount of electricity and money and also to facilitate the people travelling on the roads.Features : Pre programmed Time switch as per season with Three Programs every month and for twelve months thirty six programs specially designed for Street Light Automation. No need of reprogramming & rewiring. User-friendly, Energy saving Efficient, Capable in Lowered CO2 Emissions. Capable of Saving Energy 35-40 %.( Depend upon user usage). Low running and maintenance cost. Availability : Contactor based and PMC based
IP Rating : IP54
Frequency : 50-60 Hz
Warranty : 1 Year
Body Material : Metal
...moreStar Delta Starter Panel 25-200 HP
52,750 Per Piece
5 Piece (MOQ)
Fully automatic digital submersible/motor control panel With MPU Controller, Microcontroller based technology Auto/manual/bypass mode selector switch, Start & Stop soft buttons, Start delay time Technical spec Wide operating Voltage range: 240-480 VAC Continuous running capacity: 100+ hrs Display Volt and Amp. Volt, Amp, Run hr Volt, Amp, Run hr LED Indication s Status : R - Y - B Phases, Healthy Power, Faults : Phase fail, Rev Phase, Unbalance V, Over/Under V, Overload Single Phasing cut-o ff ✓ ✓ ✓ Reverse Phasing cut-o ff ✓ ✓ ✓ Phase Unbalance cut-off (~60 V) ✓ ✓ ✓ Over & Under voltage cut-off fixed fixed Site settable (by soft switch) Overload cut-off Site settable (by knob) Site settable (by knob) Site settable (by soft switch) Dry run ✘ ✘ ( o p tio nal) MCB/MCCB ✘ ✓ ✓ Remote trip ✘ ✘ ( o p tio nal) Contactor PMC Contactor for smooth, fast (No chattering or coil burning problem) (5 years warranty on contactor’s coil against burning) Body Rust-free GPSP Sheet, Wall mounting, compact s ize Connection Heavy duty DMC connection terminals for input and output Screw tight connection (smaller rating), ring type thimble (h
Country of Origin : India
...moreSingle Phase Motor Starter Control Panel
1 1000 Pieces (MOQ)
BASE Manual motor starter with MCB Analog ampere meter & Analog Volt meter Manual start/ Manual stop by switch Power on LED indication Used for oil filled submersible pump Available in : 1 HP & 1.5 HP E-BASE Manual motor starter with MCB Analog ampere meter & Analog Volt meter Manual start/ Manual stop by smooth push buttons Power on & Motor on LED indication Voltage check button Used for oil filled & water filled submersible pump Available in : 1 HP, 1.5 HP, 2 HP & 3 HP Royal Digital Overload Relay Over / Under load cut-off Over / Under voltage cut-off Digital Ampere & Volt meter MCB for Protection Startup delay time Push Buttons for Start & Stop Elegant & Sleek Design Available in : 1 HP, 1.5 HP, 2 HP, 3 HP, 3 HP (PMC), 5 HP (PMC), 7.5 HP (PMC) Super Royal Digital Overload Relay Digital Water level indication Over / Under load cut-off Over / Under voltage cut-off Digital Ampere & Volt meter MCB for Protection Startup delay time Soft push buttons for Start & Stop Elegant & Sleek Design Magnetic float sensor (included) (2 sensors and 4 sensor system available) Available in : 1 HP, 1.5 HP, 2 HP & 3 HP
Application : Industrial
Phase : Single
Efficiency : Consistent
Condition : New
...moreSingle Phase Automatic Changeover 40 AMP
1,705 Per piece
10 piece (MOQ)
Operating Volt: 130- 280 VAC (P-N) LED Indications for mains & gen ON Minimum changeover time to protect sensitive equipment Time delay in Gen mode for higher capacity Fully automatic opera tionwith Electrical interlocking. Fabrication: Powder Coated GI Box, Wall mounting, compact size Long life and maintenance free Heavy duty DMC connection terminal block Screw tight connection for 40 & 63 A. and ring type thimble for 100 A. Auxiliary contacts for portable genset for stop command
Type : Automatic Changeover Switch, Automatic Changeover
Material : Powder Coated GI Box
Brand Name : Subtech
...moreProgrammable Digital Timer Switch
1 1000 Pieces (MOQ)
Digital Time Switches are used where electrical equipment must be periodically switched on and off for pre-programmed daily or weekly times. Digital time switches available with only 5 pin timer. The 5 pin model connection is an AC 220 is just like a switch. It can be used for switching to any application individually or with group of appliances.Features : Digital programmable Daily, weekly timer basis. Upto 16 programs daily Inbuilt rechargeable V80H battery for memory backup means no issue of replacing battery, Battery charge last for at least 1-2 months without charge. i.e. Without AC supply connectivity. Led power indicator, LCD on screen displays for on and off switching status. Contact – single pole - single throw, Contact capacity-16 Amp, 240 VAC. Running accuracy ± 1 second / day at 20°, Minimum time setting - 1 minute. It can be used for street lights, motors, T.V., AC etc.
...moreMotorized Butterfly Valve
1 1000 Pieces (MOQ)
SUBTECH series UPVC plastic butterfly valve according to the different medium has a variety of optional material; corrosive resistance is strong, small volume, light weight, extremely non-toxic material. The Mid Stem Structure in this butterfly valve will protect the water leakage from butterfly valve to motor. It is used in industries, multi storied buildings, malls to control the flow of liquids. Features : Can be operated automatically, manually or remotely Epoxy resin coating over mid stem structure prevents structure from corrosion. Operating Voltage - 130V to 280V. Maintenance free Can be used for any type of liquid. Size - 500mm to 300mm
Application : Indstrial
...moreLT Distribution Panel
1 50/ Day unit (MOQ)
It is used in electricity supply systems to divide electrical power feed into other circuits. It has a key role in supplying power and protecting permanently installed equipment for building such as power and lighting facilities while providing a protective fuse or circuit breaker for each circuit, in a common enclosure. Features : Manufactured for multiple operations with PMC Technology advantages without any problems like overheating & burning of coil. Manufactured in GI sheets to provide high strength, longer service life, corrosion free, low maintenance cost. Provided with hinges, fixings and locks & fully enclosed switchgear.
Application : Industrial area
Warranty : 1 Year
...moreLED Flood Light
960 Per Piece
10 Piece (MOQ)
The luxstar Freedom Neo 30W flood Lighting LED is a high-quality, energy-efficient LED light that is very much suitable for street lighting applications. With a long life span and low power consumption, this LED light is a great choice for any street lighting project. If you need a powerful and efficient LED street light? You will love our luxstar Freedom Neo. This flood light consumes only 30 watts of power and is built to last with a long life. It is also IP65 rated for protection against the elements. Best of all, the luxstar Freedom Neo fits into any budget.
Brand Name : Subtech
...moreFlood Lights
3,270 Per Piece
Power 150 W Lighting Color Cool White Lighting Type LED IP Rating IP65
Driven Type : Electric
Lighting Type : LED
Shape : Square
...moreFire Fighting Control Panel
1 500 Pieces (MOQ)
Fire Fighters is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operation integrity and provides for automa control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also supply electrical energy to operate any associated initiating device, notification appliance, control, transmitter or relay. Features : Fire Fighting Pump control panel with necessary safety features for Hydrant Pump, Sprinkler Pump, Jockey Pump & Booster Pump. Suitable to work in Auto & Manual mode to maintain water pressure in hydrant & sprinkler water line. The Fire Panel receives signal from alarm devices like Pressure Switch and activates motor control devices to provide power to fire pumps and monitor its performance.
Application : Industrial
Condition : New
...more100 AMP AMF Control Panel for 30 Kva Dg
28,500 Per Piece
5 Piece (MOQ)
Operating Volt: 140- 280 VAC (P-N) Contactor coil activates only for 1 sec Automatic load transfer among Mains and genset Auto Start/Auto Stop the Genset when Mains fails/restores Mains input: 3 phase, Gen input: 3 phase LED Indications for mains (R-Y-B), gen ON, load ON, mode & fault Minimum changeover time to protect sensitive equipment Mains restore delay time: 5 sec, Cranking time: 3-5 sec., Cool down time: 10 sec Gen output delay time: 8-10 sec, 3 cranking attempts for genset with 15 sec intervals Microcontrolled based system with Electrical interlocking Audio visual alarm on common Genset faults Soft button for Auto/Manual mode selection, manual start/stop Battery charger inbuilt Compatible for new electronic controller based and old key type genset as well. Three pole and Four pole available Current rating 63 Amp. to 150 Amp., suitable for upto 63kVA genset Fabrication: Powder Coated GI Box, Wall mounting, compact size Works well on low / high voltages, no chattering or coil burning, smooth switching Long life and maintenance free Heavy duty DMC connection terminal block Screw tight connection for 63 A. and ring type thimble for 100 and 150 A. Provision for Remote operation (auto/manual, start/stop)
Color : Gray, Grey
Application : Control Panel
Material : PVC
...moreAutomatic Mains Failure Panel
1 1000 Pieces (MOQ)
Auto main failure panel is used for the automatic operation of the Genset. It monitors the power availability of both “MAINS” and “GENERATOR” automatically, and delivers you the healthy power continuously; on the other hand it will monitor the operation state for Generator while the Generator is running. During abnormal or common faults of generators, AMF Panel will give you both the visual (by LED) and audio signal feedback.Features : Auto Start & Auto Stop the Genset when Mains fails & restores respectively. Cranking standard - three cranking attempts with 15 sec intervals. Auto / Manual mode selector available, automatically changes lines from Mains and Gen Line and vice versa. Mains restoration delay time - 10 sec, start delay time: 3-5 sec. cool down time: 30-40 sec, DG output delay time: 8-10 sec. Low/high Voltage protection, Reverse phase protection (optional) Digital Volt, Amp., Hz. Meters & 5 Indication for Mains, DG and load in Display Contactor Coil Voltage: 180-260 VAC & Pre Magnetic Contactor Coil Voltage- 130-280VAC Availability : 40 Amp. to 500 Amp.
Application : Controlling DG, etc
Power : 415-440VAC, etc
...moreAutomatic Change over 40 AMP Three Phase
6,500 Per piece
5 Piece (MOQ)
Operating Volt: 130- 280 VAC (P-N) LED Indications for mains & gen ON Minimum changeover time to protect sensitive equipment Time delay in Gen mode for higher capacity Fully automatic opera tionwith Electrical interlocking. Fabrication: Powder Coated GI Box, Wall mounting, compact size Long life and maintenance free Heavy duty DMC connection terminal block Screw tight connection for 40 & 63 A. and ring type thimble for 100 A. Auxiliary contacts for portable genset for stop command ( IGN )
Type : Changeover Panel
...moreAutomatic Changeover Switch
1 1000 Pieces (MOQ)
Auto changeover the need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where continuous power supply is must. Their complexity has increased as continuous information and communications are needed to control automated process, be in industries, commercial complexes, hospitals, hotels or even modern residences. Automatic Changeover from main supply to stand by supply is vital for all the above kinds of load. In case of both DG Supply as well as mains supply, comes together then priority will be of mains because the automatic changeover will change DG supply to mains. In the event of power failure, the standby power is usually expected to take over automatically. Electrical starting equipment, battery bank and diesel generator are required for the automatic operation. The automatic transfer is achieved mostly by AMF Panels. The process of on-load transfer has to be monitored & controlled for a smooth Changeover and within safety limits of all elements of the system. Features: Operating Voltage 130V to 280V Inbuilt SMPS supply to operate the circuit Simplifies electrical complexity with NFC System LED Indication for MAINS ON & GENERATOR ON Potential free contact for Start/stop of generators (optional) Genset Stop system is inbuilt, especially for Portable Generators Time Delay on generator mode in changeover in higher capadty When main supply is resumed, the connected load is automatically shifted to mains Powder Coated 130 Compact size Wall mounting, Temper proof and maintenance free Microcontroller based technology with Pre-Program interlocking to prevent short circuit. Single Phasing does not affect the overall output: Only the absent phase of mains will fail in output, not all three phases will fail Switch over time for genset to main is very minimum so that even sensitive equipment's do not get "OFF" during the switch over Its unique circuit design enables the relay to be in 'ON' position only while the genset is in use. During main supply the relay remains in 'OFF' position. Due to this the life of changeover gets increase. No Time Delay for output on resumption of Mains Supply whenever DG's not working. In that time Interval as load remain connected to the mains only. (Even in the absence of one or two phase also) DG Supply can/cannot be used at the time of single phasing of Mains supply. (Because some users are satisfied even in single phase to save the diesel cost.) In the Presence of supply in all three phase, load automatically shifts from DG to Mains with a time delay of 5 Sec. But when there is one or two phase supply, Load will not shift from DG to Mains only.
Warranty : 12 Months
...moreAutomatic Battery Charger Transformer Based 2 Volt 6Amp
1 Piece (MOQ)
Our team of quality analysts strictly tests each product against varied quality parameters ensuring zero defects at buyer's end. Be it online payment or offline, we make possible for you to make trade transactions as per your convenience. We offer both offline and online mediums to make payment.Automatic Battery Charger for charging generator battery automatically with LED indications and fault protections. Features : Trickle and boost mode Reverse polarity protection Auto cut-off on full charge Availability Transformer Base Battery Charger : 12/24 VDC SMPS Base Battery Charger : 12/24 VDC
Color : Grey
Type : Battery Charger Transformer
...moreAutomatic Changeover Switch 150 AMP for 62 Kva DG
5 Piece (MOQ)
It is used to overcome problems likes single phasing, reverse phasing and unbalance supply to protect the electrical/electronic appliances.Features : Auto cut off on single phasing & unbalances supply. Auto corrects in Reverse phasing Switching time is 10 second with an Operating Voltage 130V to 280V. Temper proof and maintenance free, powder coated box. Microcontroller based technology with Pre Program interlocking to prevent short circuit. Minimum heat dissipation & energy losses. Remove problem of sparking & burning with the usage of Pre Magnetic Contactor.
Color : Grey
Condition : New
Automatic Grade : Automatic
Application : Protective
Certification : ISI Certified
Warranty : 1Year
...moreAPFC Panel
1 50/ Day unit (MOQ)
It is used to maintain power factor by the use of capacitor bank to suit the variations in inductive/resistive loads. Specially in industrial sector, heavy inductive loads are very common to give low power factor, which results in higher demand charges and also low power factor penalties. APFC panel provides automatic switching operation of the suitable capacitor bank for fixing power factor from load fluctuation.Features : User friendly microprocessor based APFC relay. Modular design with easier assembly, Installation & maintenance. Power factor correction done with help of power factor controller & power contactors by switching In/Out 6/8/12 steps of capacitor banks. Used for three phase loads. Availability : Contactor based and PMC based
Features : Minimum maintenance
...more150 AMP AMF Panel for 62 KVA
36,500 Per Piece
10 Piece (MOQ)
Features Operating Volt: 140- 280 VAC (P-N) Contactor coil activates only for 1 sec Automatic load transfer among Mains and genset Auto Start/Auto Stop the Genset when Mains fails/restores Mains input: 3 phase, Gen input: 3 phase LED Indications for mains (R-Y-B), gen ON, load ON, mode & fault Minimum changeover time to protect sensitive equipment Mains restore delay time: 5 sec, Cranking time: 3-5 sec., Cool down time: 10 sec Gen output delay time: 8-10 sec, 3 cranking attempts for genset with 15 sec intervals Microcontrolled based system with Electrical interlocking Audio visual alarm on common Genset faults Soft button for Auto/Manual mode selection, manual start/stop Battery charger inbuilt Compatible for new electronic controller based and old key type genset as well. Three pole and Four pole available Current rating 63 Amp. to 150 Amp., suitable for upto 63kVA genset Fabrication: Powder Coated GI Box, Wall mounting, compact size Works well on low / high voltages, no chattering or coil burning, smooth switching Long life and maintenance free Heavy duty DMC connection terminal block Screw tight connection for 63 A. and ring type thimble for 100 and 150 A. Provision for Remote operation (auto/manual, start/stop)
Brand Name : Subtech
Color : Gray
Application : Power Supply
Certification : ISI Certified
...moreACCL Automatic Source Changeover
1 1000 Pieces (MOQ)
SU BTECH make CLD cum auto changeover, which is a fully automatic high precision system for efficient distribution of individually rationed generator power, is an advantageous and cost effective alternative to conventional manual cha ngeovers. The auto changeover cum current limiting device (CLD) works as a changeover and also gives protection to generator due to overload and abnormal supply. It is a Micro-controlled Pre-Programed overload protection system for multiple operations, mostly used for generators and power backup multi storied societies, malls, apartments etc. Features: Settable voltage range for mains and genset Settable overload limit for genset Auto trip on overload to prevent genset overloading Overload trip time will decrease as overload increase Once tripped, auto re-starts after 10 seconds (max) and so on upto 5 trials Auto trip on under/over voltage on mains and genset to avoid damages to appliances Continue glowing LEDs on healthy conditions & blinking LEDs on source waiting and faulty conditions After 5 trials, tripped permanently for 3 minutes Automatically tries again after 3 min or user can reset manually or wait for the mains Safeguards generator by gradual loading and precision monitoring Assured availability of allotted current; no less, no more Significant saving on wall space and wiring.
Warranty : 1 Year
Feature : Rust resistance
Application : Industrial
...more100 AMP Three-Phase Automatic AMF Panel
29,500 Per Piece
100 Piece (MOQ)
Features of this panel:- Operating Volt: 140- 280 VAC (P-N) Contactor coil activates only for 1 sec Automatic load transfer among Mains and genset Auto Start/Auto Stop the Genset when Mains fails/restores Mains input: 3 phase, Gen input: 3 phase LED Indications for mains (R-Y-B), gen ON, load ON, mode & fault Minimum changeover time to protect sensitive equipment Mains restore delay time: 5 sec, Cranking time: 3-5 sec., Cool down time: 10 sec Gen output delay time: 8-10 sec, 3 cranking attempts for genset with 15 sec intervals Microcontrolled based system with Electrical interlocking Audio visual alarm on common Genset faults Soft button for Auto/Manual mode selection, manual start/stop Battery charger inbuilt Compatible with new electronic controller-based and old key-type genset as well. Three pole and four pole available Current rating 63 Amp. to 150 Amp., suitable for upto 63kVA genset Fabrication: Powder Coated GI Box, Wall mounting, compact size Works well on low/high voltages, no chattering or coil burning, smooth switching Long life and maintenance free Heavy duty DMC connection terminal block Screw tight connection for 63 A. and ring type thimble for 100 and 150 A. Provision for Remote operation (auto/manual, start/stop).
Shape : Rectangle
Color : Silver or Grey
Application : Power Supply
Feature : Excellent Reliabiale, Fire Resistant, Light Weight, Perfect Shape
Type : Amf Panel
Frequency : 60Hz
Country of Origin : India
...moreOpening Hours