Multi Protocol Fire Alarm Control Panel
Get Price Quote
We are offering multi protocol fire alarm control panel. the zx1e is an intelligent fire alarm control panel. It has been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular, scaleable fire alarm platform suitable for protecting all types of premises. The zx1e control panel supports a total of five industry leading protocols, allowing fire detection devices to be independently selected based on performance or aesthetic appeal. The zx series control panels seamlessly integrates with apollo (xplorer, xp95 & discovery), hochiki esp, nittan, morley-ias and system sensor detection device protocols. Designed for maximum flexibility the zx1e control panel is supported by a complete suite of peripherals and software tools. Information on the location of fires, faults and system status can easily be displayed or printed in multiple locations. Integration to voice evacuation systems, paging systems and third party control systems is supported through a range of peripheral interface units. features: multi protocol modular concept simple, robust design intuitive to use easy to maintain easy to expand easy to network easy to install easy to configure
2 & 4 Zones Fire Alarm Control Panel
Get Price Quote
Best Deals from Fire Control Panel
2 Loop Fire Control System
Get Price Quote
Fret not! We are here to help you out with the payment procedures. Be it online or offline payment method, we are here to assist you all the way through the payment process. We have a capacious warehouse facility that assists us completely in making stock and furnishing varied requirements of the clients. Also, our facility is equipped with modern storage amenities.Standard Features : UL 864 9th Edition listed Multi-Loop 2 Analog Addressable Loops Field upgradable to 4 126 primary points per loop Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone. 800 points per panel when using devices with subpoints Up to 10,000 ft. wiring length on SLC loop 64 Panels on a network Programmable through a PC connection to the panel, or through keypad Programmable relays – 5 Supervised Powered Outputs – 3 Programmable Notification Appliance Circuits - 4 Power per NAC - 1.6 Amps Max Programmable outputs on SLC loop Programmable Function button on front display Fire Drill button on front display Day and night sensitivity settings (user programmable) Power Supply - 5.25 Amp, regulated & integrated LCD Display - 8x40 Zonal Mode - Annunciation by zone w/o individual relationships Panel Ring Modes - Common, Zonal, Stage 2 NAC Outputs programmable as Continuous, March, Temporal Program Cause and Effects AND, OR, or Any Two (Cross Zone) Battery size - Up to 17 Ah in standard enclosure; up to 52 Ah with external cabinet Access levels - 3 Access key switch - Yes Recognized for use in High Rise One man walk test – Fire Test Mode Available with semi flush trim ring Available in Red or Gray Product Overview : The VF1460 and VF1480 analog addressable FACP supports 2 or 4 SLC loops for a total of 500 primary points or 800 points using subpoints. SLC loop communications uses standard twisted pair cabling, shielded cable is not necessary. The panel may be configured with various communication cards; Communications options support central station monitoring, Virtual Panel, and networking. The Panel can be configured as a stand alone panel with just a few devices for a small building, it can also operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility. Auto Learn capability provides a convenient method to troubleshoot new installations before final programming is loaded. Added Features : Elite with eNET (VF1465/VF1485) Network uses standard RS485 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed Secure, fault tolerant communication Up to 64 nodes Elite with DACT (VF1464/VF1484) Dual line digital communicator and modem Contact ID and SIA reporting UL 864 9th edition listed Zone or point reporting Backup and duplicate reporting
Fire Alarm Control Panel
Get Price Quote
We have parted our infrastructure into several units and one of them is warehouse wherein we keep a huge stock for furnishing urgent and quick requirements of the clients. We have hired only professional packaging personnel who have experience and expertise in this domain. They make use of the finest quality packing material to ensure zero damage during transit.
Fire Alarm Control Panel
Get Price Quote
We are the leading Manufacturer and Supplier of efficient Fire Alarm Control Panel. The Fire Alarm Control Panel is the Central Monitoring Station where all signals are received and transmitted. It is important that the person responsible for taking action, should know exactly where and what the problem is, as soon as he receives a signal from the panel, given below are the details of how to interpret the various lights and switches on the panel fascia.
Fire Alarm Control Panel
3,500 Per Piece
Addressable Fire Alarm Control Panel
Get Price Quote
Features Each loop can connect up to 250 addressable devices. Maximum networking are 32 loops and total addressable points are 8000. Large LCD screen (40 x 15 lines) allows more events to be displayed on the same screen. Loop device can be set up to be temporarily isolated. Individual loop module test feature to save time on panel test. On-board Self-test feature for simulating alarm output. Easy system programming through PC to panel. Events log can store up to 2030 events. Specification optional thermal printer that can printout complete panel status.
OIL FIRED BOILER CONTROL PANELS
Get Price Quote
We design and manufacture a number of Oil Fired Boiler control panels , incorporating Client specified , and meeting IBR & Class regulations. Most of the Marine Boiler panels can be replaced by our panels. Safety Panels , Combustion control panels , Burner Management Systems (BMS) , individual process Loop control systems , spares & service of burners. Client specific – discrete or PLC based panels with Local & Remote control HMI’s are available. Contact us for a complete engineered solution.
Fire Alarm Control Panels
Get Price Quote
The range of Conventional Fire Alarm Control Panels is ideal for Banks, Small Offices, Residential buildings and Warehouses. The indication of fire is zone wise. Audio notification is provided by hooters, PA system and voice annunciation procedures. Special RS-485 based repeaters and mimic panels are available for alphanumeric annunciation of zone names.
Fire Control Panel
2,850 Per Piece
2 Piece (MOQ)
Fire Engine Control Panel
Get Price Quote
Fire Engine Control Panel user friendly, Highly reliable Fire Engine Control System. This is provided with Microcontroller based Diesel Engine Controller “ECR16” with Audio Visual Alarm and Battery charger with Ammeter Voltmeter. The setting for “ON TIME”, “OFF TIME” & Attempt for CRANK can be done by “DIP SWITCH” provided on the backside of controller. Maximum four attempts can be selected. SMPS Battery charger is provided to charge main & standby battery in trickle & boost mode automatically. Battery charger is automatically disconnected when Engine is in running condition.
Fire Alarm Control Panel
35,500 Per Piece
1 Piece (MOQ)
Repeater Panel
Get Price Quote
Repeater Panel Specification Ravel Indian Manufacturer, International standard. Switch Mode Power Supply. Modular Construction, Serviceable. Surface Mount Technology. Battery polarity & deep discharge protection. As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication. Switch Mode Power Supply. Tactile Keypad for easy panel operation. System on indication. Main, Standby status indication. Low Battery visual warning with audible tone. Relay output for actuators for Fire and Fault. Lamp Test facility Zone wise one man walk Test Facility. Zone wise Isolation facility with loop voltage cut off. Compatible to all type of Conventional Detectors. Optional Zone Wise Sounder / Zone Wise Contact.
Fire Fighting Control Panel
Get Price Quote
Features: Completely automatic in operation except Switching off Diesel Engine driven pump Automatic operation of Main & jockey pumps Diesel Engine panel contains Auto Diesel Engine Starter & Battery charger Audio / Visual Fire alarm when Hydrant goes ON Application: To Automatically control the fire pumps in case of fire situation. It is also incorporated with the Alarm system to maintain all the fire pipe line at set pressure to start DG engines automatically in case electricity failure Specification: Incoming Control & Total Protection with MCCB / MPCB / MCB / SFU / HRC Fuses BAS/BMS related contacts incorporated in the Panel Switchgear from L&T / Schneider Electric / Siemens Control Panels for DOL / Star Delta Motors upto 1000 HP
Fire Alarm Control Panel
Get Price Quote
Fire Alarm Control Panel
25,000 Per Piece
1 Piece (MOQ)
Fire Alarm Control Panel
Get Price Quote
The Fire•Lite MS-25(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. With an extensive list of powerful features, the MS-25 fits into applications previously served only by conventional panels. This compact, intelligent addressable control panel supports up to 25 Honeywell Fire Systems addressable devices of any type of detectors and modules. With code wheel addressable detectors/modules and JumpStart® feature the MS-25 can be Life Safety operational without a single programming tool. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Fire-Lite. The MS-25's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board and housed in a metal cabinet. Custom programming can be performed through FACP built-in browser (no programming software required) with a PC. NOTE: Unless otherwise specified, the term MS-25 is used in this data sheet to refer to the MS-25 and the MS-25E. For details on the Canadian version, see DN-60641. features • Two independently programmable output circuits. Circuits can be configured for the following outputs: – Style Y (Class B). – Door Holder Service (cannot be used for notification appliances). – Aux Power Source (cannot be used for notification appliances). • Silence Inhibit and Auto-silence timer options. • Continuous or Temporal code. • Selectable strobe synchronization per NAC. • Up to 2.0 A total output power, 1.0 A for auxiliary power and door holder. Each circuit can source up to the total system current 2.0 A. specification • ETL listed to ANSI/UL 864 9th Edition Standard • Listed to UL Standard 864, Ninth edition. • JumpStart® auto-learn feature reduces installation time and makes programming easy. • Built-in digital communicator. • Two programmable Style Y (Class B) notification appliance circuits (NACs). • Selectable strobe synchronization for System Sensor®, Gentex®, Wheelock® or AMSECO devices. • Two programmable Form-C relays and one Form-C trouble relay. • Automatic detector sensitivity testing (NFPA 72 compliant). • Point status eliminates calibrated smoke test requirements for NFPA 72. • Drift compensation. • Alarm verification per zone of detectors. • Walk-test. • Honeywell Fire Systems detectors and modules are codewheel addressed for faster installation time. • Maintenance alert region. • Uses standard wire (unshielded or twisted pair). • Central Station reporting up to five zones. • On Board Annunciator.
Fire Control Panel
Get Price Quote
We are offering fire control panel. Conventional apollo make fire alarm control panel 2 zone / 4 zone & 8 zone.
Repeater Panel
Get Price Quote
Features CRCA sheet with powder coated finish. Operates on 24 VDC. Fire Fault status in unambiguous coloured LED indication. System on indications Silence facility. Lamp test facility. RS485 for Repeater Communication (Use shielded or twisted wire (CAT5E or CAT6)).
Fire Alarm Control Panel
Get Price Quote