Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
Output Ripple0.2% RMS
Operating Temp.0°
Storage Temp-20°C
Overload Continuous2 x Rated Current, 1.2 x Rated Voltage
Breakdown Impulse Voltage4.5KV , 1 x 40µs (without dewing.)
Tempreature Coefficient0.03% / °C.
Dielectric Withstand Voltage between Input / Output / Power / Case2 KV AC for 1 minute.
Insulation Resistance (@ 500V DC)>100MΩ
"MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
"MECO-G" WATT Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
Output Ripple0.2% RMS
ResponseLess than 0.5 Sec.
Zero Adj.± 2% Min
Span Adi.±10 % Min.
Dielectric Withstand Voltage between Input / Output / Power / Case2 KV AC for 1 minute.
Insulation Resistance (@ 500V DC)>100MΩ
"MECO-G" AC Reactive (VAR)Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable and are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
"MECO-G" AC Reactive (VAR)Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable and are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
"MECO-G" Tap Position Transducers converts a resistance input to a standard DC output signal which is directly proportional to the input resistance. This DC output signal is Optically Isolated, Ripple Free and Stable. These accurate and reliable outputs are suitable for Telemetering, Data Loggers, PLC′s and SCADA systems
"MECO-G" Tap Position Transducers converts a resistance input to a standard DC output signal which is directly proportional to the input resistance. This DC output signal is Optically Isolated, Ripple Free and Stable. These accurate and reliable outputs are suitable for Telemetering, Data Loggers, PLC′s and SCADA systems
Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
Output Ripple0.2% RMS
ResponseLess than 0.5 Sec.
Zero Adj.± 2% Min
Span Adi.±10 % Min.
Operating Temp.0°
Storage Temp-20°C to 70°C
Overload Continuous2 x Rated Current, 1.2 x Rated Voltage
Tempreature Coefficient0.03% / °C.
Insulation Resistance (@ 500V DC)>100MΩ
"MECO-G" Signal Isolating and DC Isolation Transducers provide a stable ripple free & optically Isolated DC output signal for various DC voltage & current Input signals. These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
...more
SIGNAL ISOLATION TRANSDUCER & DC ISOLATION TRANSDUCER
"MECO-G" Signal Isolating and DC Isolation Transducers provide a stable ripple free & optically Isolated DC output signal for various DC voltage & current Input signals. These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
Suppressed scale Ammeters with suppression upto 600% can be supplied in all types. Accuracy for all supressed meter is 2x accuracy for the normal range.
For Highter range Ammeter use meter of 5A with appropriate CT.
For Higher range Voltmeter use meter of 110V with appropriate P.T.
SI-72 and SI-96 meters are with interchangeabel scale.
Back terminal protective cover for SI-72 and SI-96 meters are available (optional).
Meters with Band Marking (RED YELLOW GREEN or any other colour) are available at extra cost.
Meters with Accuracy Class 1.0% can be supplied at extra cost.
Single Scale Double Stamping Meters can also be supplied.
Additional Dials Also available.
Suppressed scale Ammeters with suppression upto 600% can be supplied in all types. Accuracy for all supressed meter is 2x accuracy for the normal range.
For Highter range Ammeter use meter of 5A with appropriate CT.
For Higher range Voltmeter use meter of 110V with appropriate P.T.
SI-72 and SI-96 meters are with interchangeabel scale.
Back terminal protective cover for SI-72 and SI-96 meters are available (optional).
Meters with Band Marking (RED YELLOW GREEN or any other colour) are available at extra cost.
Meters with Accuracy Class 1.0% can be supplied at extra cost.
Single Scale Double Stamping Meters can also be supplied.
Additional Dials Also available.
Accuracy± 0.5% of Span (standard) Others on request (optional)
Accuracy Range0 to 120%
Zero Adjustment.± 2% of Span (min.)
Response Time< 0.5s for 0 to 90% of Output
Impulse Test4.5KV, 1 x 40µS (W/o Dewing)
Applicable StandardsElectrical Measuring Transducers for Converting AC Electrical Quantities into DC Electrical Quantiti
MECO-G" Power Line Transducers are designed for AC Power Line parameters like Voltage, Current, Wattage, Var, Frequency, DC Isolation, TAP Position and Temperature. These reliable and accurate Transducers are in applications in all sectors of the power and process industry since over 20 years. These Transducers give a load independent and isolated DC output directly proportional to the input parameters. "MECO-G" Transducers are widely used for automation and control of power and process systems as well as for local and remote monitoring of the electrical parameters at every stge of electricity generation, transmission and distribution. They are ideal for SCADA, energy management, telemetering, data-logging as well as central monitoring systems. "MECO-G" Transducers are generally designed to comply to the requirements of I.S. 12784:1989 (Reaffirmed in 1993). All "MECO-G" Transducers pass through a stringent manufacturing and in-house quality control process consisting of vibration, burn-in and calibration tests to ensure complete reliability and accuracy during continuos operation.
MECO-G" Power Line Transducers are designed for AC Power Line parameters like Voltage, Current, Wattage, Var, Frequency, DC Isolation, TAP Position and Temperature. These reliable and accurate Transducers are in applications in all sectors of the power and process industry since over 20 years. These Transducers give a load independent and isolated DC output directly proportional to the input parameters. "MECO-G" Transducers are widely used for automation and control of power and process systems as well as for local and remote monitoring of the electrical parameters at every stge of electricity generation, transmission and distribution. They are ideal for SCADA, energy management, telemetering, data-logging as well as central monitoring systems. "MECO-G" Transducers are generally designed to comply to the requirements of I.S. 12784:1989 (Reaffirmed in 1993). All "MECO-G" Transducers pass through a stringent manufacturing and in-house quality control process consisting of vibration, burn-in and calibration tests to ensure complete reliability and accuracy during continuos operation.
Size96 X 96 mm & 114 X 144 mm with narrow black bezal
RATED ACCURACYWATTMETERS & VAR METERS 1.5% FSD as per IS 1248/83. POWER FACTOR METERS 3% as per BS 89, IEC 51.
CASINGFerro Magnetic
SCALE LENGTH96 X 96 mm : 90mm Approx. 144 X 144 mm : 140mm Approx.
TEST VOLTAGE2KV AC for 1 Minute.
INSULATION RESISTANCEOver 20MΩ at 500VDC.
Instrument with double scale stamping can be supplied
Instrument with centre zero scale can be supplied.
Rubber Gaskets for Vibration protechtion can be supplied with instrument on request
Portable Type meters aslo available
Instrument with double scale stamping can be supplied
Instrument with centre zero scale can be supplied.
Rubber Gaskets for Vibration protechtion can be supplied with instrument on request
Portable Type meters aslo available
Size : 96 X 96 mm & 114 X 144 mm with narrow black bezal
Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
Output Ripple0.2% RMS
ResponseLess than 0.5 Sec.
Storage Temp-20°C
Overload Continuous 22 x Rated Current, 1.2 x Rated Voltage
Breakdown Impulse Voltage4.5KV , 1 x 40µs (without dewing.)
MECO-G" AC Frequency Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
MECO-G" AC Frequency Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
3 Seperate Display For Volts, Current, Frequency RPM Hours.
Hour display
Multipiler for Voltage, Current, Frequency to display PT, CT primary values and RPM High Accuracy and Stability.
Microcontroller based design
Small, Compact in size.
"MECO-G" has introduced a unique,low-cost meter for the first time. It has simultaneous display for VOLTS, CURRENT, FREQUENCY. This reduces the cost of using 3 seperate meters and saves space on the panel. Cable wiring is also reduced, effecting huge saving in cost. Running time of generators is displayed in hours. Two separate models for Single Phase and Three Phase - Four Wire are availab
3 Seperate Display For Volts, Current, Frequency RPM Hours.
Hour display
Multipiler for Voltage, Current, Frequency to display PT, CT primary values and RPM High Accuracy and Stability.
Microcontroller based design
Small, Compact in size.
"MECO-G" has introduced a unique,low-cost meter for the first time. It has simultaneous display for VOLTS, CURRENT, FREQUENCY. This reduces the cost of using 3 seperate meters and saves space on the panel. Cable wiring is also reduced, effecting huge saving in cost. Running time of generators is displayed in hours. Two separate models for Single Phase and Three Phase - Four Wire are availab
4 in 1 display
Rescaleable facility for Volt, Amps, Frequency
High, Accuracy and Stability
Small, Compact in size
Microcontroller based design
"MECO-G" has introduced a unique 4-in-1 meter for the first time. It has simultaneous measurements of Volt, Current, Frequency and Power Factor (Single Phase and three phase balanced load). This reduces the cost of using 4 separated meters and saves space on the panel. Wiring of cables is also reduced thus effecting tremendous saving in cost.
4 in 1 display
Rescaleable facility for Volt, Amps, Frequency
High, Accuracy and Stability
Small, Compact in size
Microcontroller based design
"MECO-G" has introduced a unique 4-in-1 meter for the first time. It has simultaneous measurements of Volt, Current, Frequency and Power Factor (Single Phase and three phase balanced load). This reduces the cost of using 4 separated meters and saves space on the panel. Wiring of cables is also reduced thus effecting tremendous saving in cost.
"MECO-G" Portable Digital Wattmeters can measure power in single phase systems with Unity Powerfactor (P.F=1.0) and Low Power Factor (P.F=0.2). These instruments are more rugged, reliable and accurate than analog meters . They are light in weight, compact in size and stylish in design .They do not have any moving parts. Display is bright Red LED's. There is no confusion of anti parallax scale.
"MECO-G" Portable Digital Wattmeters can measure power in single phase systems with Unity Powerfactor (P.F=1.0) and Low Power Factor (P.F=0.2). These instruments are more rugged, reliable and accurate than analog meters . They are light in weight, compact in size and stylish in design .They do not have any moving parts. Display is bright Red LED's. There is no confusion of anti parallax scale.
"MECO-G" Portable Digital Ammeters, Voltmetrs and frequency meters are designed for AC, DC and True RMS measuremnet. Single Phase Portable Digital Watttmetrs can measure poer in single phase system with Unity Power Factor (P.F = 1.0) and Low Power Factor (P.F = 0.2). These instruments are more rugged, reliable and accurate than analog meters. They are light in weight, compact in size and stylish in design. They do not have any moving parts. Display is bright Red LED's. There is no confusion of anti parallax scale.
...more
DIGITAL PORTABLE AMMETERS, VOLTMETERS, FREQUENCY METERS
"MECO-G" Portable Digital Ammeters, Voltmetrs and frequency meters are designed for AC, DC and True RMS measuremnet. Single Phase Portable Digital Watttmetrs can measure poer in single phase system with Unity Power Factor (P.F = 1.0) and Low Power Factor (P.F = 0.2). These instruments are more rugged, reliable and accurate than analog meters. They are light in weight, compact in size and stylish in design. They do not have any moving parts. Display is bright Red LED's. There is no confusion of anti parallax scale.
Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
Output Ripple0.2% RMS
ResponseLess than 0.5 Sec.
Zero Adj.± 2% Min
Span Adi.±10 % Min.
Operating Temp.0°
Storage Temp-20°C
Overload Continuous2 x Rated Current, 1.2 x Rated Voltage
Breakdown Impulse Voltage4.5KV, 1 x 40µs (without dewing.)
Tempreature Coefficient0.03% / °C.
Dielectric Withstand Voltage between Input / Output / Power / Case2 KV AC for 1 minute.
Insulation Resistance (@ 500V DC)>100MΩ
"MECO-G" AC Current Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
"MECO-G" AC Current Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
Micro controller based design to give accurate correction of Power Factor
Automatic KC Value calculating.
Multiple data display, including Power Factor (Lag Lead), KVAR value, Voltage, Current, Frequency and Tempreature
KVAR value can be set directly for each stage. Each stage can have different KVAR value, enabling precise control
Capacitor connection is cyclical. using First In First Out principle and is used according to average utilization principle prolonging the realy< connection point life.
Programmable alarm relay output. Can be set to give alarm for abnormal Voltage, Current, KVAR, Power Factor, Frequency and Temperature value.
CT and PT value can be set to display real KVAR, Voltage and Curren value
Micro controller based design to give accurate correction of Power Factor
Automatic KC Value calculating.
Multiple data display, including Power Factor (Lag Lead), KVAR value, Voltage, Current, Frequency and Tempreature
KVAR value can be set directly for each stage. Each stage can have different KVAR value, enabling precise control
Capacitor connection is cyclical. using First In First Out principle and is used according to average utilization principle prolonging the realy< connection point life.
Programmable alarm relay output. Can be set to give alarm for abnormal Voltage, Current, KVAR, Power Factor, Frequency and Temperature value.
CT and PT value can be set to display real KVAR, Voltage and Curren value
"MECO-G" Portable Ammeters & Voltmeters are designed for the use in laboratories, field & test room where precision measurement is required. These portable instruments can be used in precision research laboratories where carefully controlled atmospheric conditions are secured, in educational institutions where possible misuses exist and in factories where these instruments are important for making calibration check on switchboard and panel instruments
"MECO-G" Portable Ammeters & Voltmeters are designed for the use in laboratories, field & test room where precision measurement is required. These portable instruments can be used in precision research laboratories where carefully controlled atmospheric conditions are secured, in educational institutions where possible misuses exist and in factories where these instruments are important for making calibration check on switchboard and panel instruments
Dielectric strength (IEC 688)AC 2KV / 1 minute between input to power terminals
Rescaleable AAC & mVDC Range
4½ digit display : 19999
Easy-to-wire, screw-type terminals
Outside dimension is DIN standard(96 * 48mm) & (96 * 96 mm)
Data hold available on request.
Rescaleable AAC & mVDC Range
4½ digit display : 19999
Easy-to-wire, screw-type terminals
Outside dimension is DIN standard(96 * 48mm) & (96 * 96 mm)
Data hold available on request.
"MECO - G" has introduced new low cost digital panel meters in size 48x96 and 96x96mm. These instruments can measure AC Volts, AC Current. They are designed using micro controller based technology. They display full 4 digits. Rescaling is done by the push switches on the front. No dip switches are used. These instruments are available in 0-5A AC, 0-750V AC. They offer more resolution than conventional instruments. They are easy to use. Programming for CT multiplier is done very easily by the switches on the front of the instrument. Auxiliary supply 110V, 230V or 440V AC (any one to avoid confusion and damage to the instrument) is available.
The price of these instruments is comparable to the cost of analog meters, with much better features, accuracies and resolution.
"MECO - G" has introduced new low cost digital panel meters in size 48x96 and 96x96mm. These instruments can measure AC Volts, AC Current. They are designed using micro controller based technology. They display full 4 digits. Rescaling is done by the push switches on the front. No dip switches are used. These instruments are available in 0-5A AC, 0-750V AC. They offer more resolution than conventional instruments. They are easy to use. Programming for CT multiplier is done very easily by the switches on the front of the instrument. Auxiliary supply 110V, 230V or 440V AC (any one to avoid confusion and damage to the instrument) is available.
The price of these instruments is comparable to the cost of analog meters, with much better features, accuracies and resolution.
Aux. SupplyAC (230V or 110V) ± 10%, 50 / 60 Hz DC Voltage on Request
Power Consumption< 5VA.
Operating Temperature0° - 50° C
Storage Temp-10° - 70° C.
Max. Rel. Humidity< 95 %
Dielectric StrengthAC 2 KV for 1 min. Between Input and Power terminals. AC 3 KV for 1 min. all terminals to case.
Max Overload1.2 XVin. (continous). 2x Iin. (continous).
3½ DIGIT BRIGHT RED LED DISPLAY
AUTO SCROLLING TO DISPLAY THREE PHASE CURRENT, VOLTAGE
HOLD TO DISPLAY INDIVIDUAL PHASE
GLOWING LED INDICATES PHASE BEING MEASURED R-Y-B, RY-YB-BR.
RESCALEABLE CURRENT RANGES WITH DECIMAL POINT SELECT
DIN STANDARD SIZE 96 X 96mm.
3½ DIGIT BRIGHT RED LED DISPLAY
AUTO SCROLLING TO DISPLAY THREE PHASE CURRENT, VOLTAGE
HOLD TO DISPLAY INDIVIDUAL PHASE
GLOWING LED INDICATES PHASE BEING MEASURED R-Y-B, RY-YB-BR.
RESCALEABLE CURRENT RANGES WITH DECIMAL POINT SELECT
DIN STANDARD SIZE 96 X 96mm.
Dielectriv strength (IEC 688)AC 2KV / 1 minute between Input to power terminals.
Rescaleable AAC & mVDC Range
3½ digit display : 1999
Easy-to-wire, screw-type terminals
Outside dimension is DIN standard (96 x 48mm) & (96 x 96 mm)
Low unit cost
Rescaleable AAC & mVDC Range
3½ digit display : 1999
Easy-to-wire, screw-type terminals
Outside dimension is DIN standard (96 x 48mm) & (96 x 96 mm)
Low unit cost
"MECO-G" has introduced Autoranging Hand held 3½ digit Digital Multimeter with Large LCD display incorporating latest technology.
These Digital Multimeters can measure AC Voltage, DC Voltage, DC Current, AC Current, Resistance, Temperature and Battery Test Voltage.
Additional Features include Diode Test, Transistor check, Continuity check, Low Battery Display, Maximum Hold, Auto power off, Data Hold and Back light.
This Multi meter has a built in Holster for anti- sliding grip.
These Multi Meters can easily fit in the pocket and are used in various industries across various sectors for maintenance and manufacturing.
"MECO-G" has introduced Autoranging Hand held 3½ digit Digital Multimeter with Large LCD display incorporating latest technology.
These Digital Multimeters can measure AC Voltage, DC Voltage, DC Current, AC Current, Resistance, Temperature and Battery Test Voltage.
Additional Features include Diode Test, Transistor check, Continuity check, Low Battery Display, Maximum Hold, Auto power off, Data Hold and Back light.
This Multi meter has a built in Holster for anti- sliding grip.
These Multi Meters can easily fit in the pocket and are used in various industries across various sectors for maintenance and manufacturing.
"MECO-G" has introduced a new series of Digital Clamp Meter in 3½ digit LCD display incorporating latest technology
These Digital Clamp meters are stable, secure and reliable.
These Digital Clamp meters can measure AC Current, AC Voltage, DC Voltage, Resistance, Capacitance, Diode Test, Continuity check, Temperature, Frequency.
Additional Features include Data Hold and Back light.
Full range overload protection circuit, unique design makes it a superior performing instrument.
These Clamp Meters are used in various industries across various sectors for maintenance and manufacturing
"MECO-G" has introduced a new series of Digital Clamp Meter in 3½ digit LCD display incorporating latest technology
These Digital Clamp meters are stable, secure and reliable.
These Digital Clamp meters can measure AC Current, AC Voltage, DC Voltage, Resistance, Capacitance, Diode Test, Continuity check, Temperature, Frequency.
Additional Features include Data Hold and Back light.
Full range overload protection circuit, unique design makes it a superior performing instrument.
These Clamp Meters are used in various industries across various sectors for maintenance and manufacturing
"MECO-G" has introduced a new series of Digital Clamp Meter in 3½ digit LCD display incorporating latest technology.
These clamp meters can measure AC Current, AC Voltage, DC Voltage, Resistance, Temperature and Frequency.
Additional Features include Diode Test, Continuity check, Data Hold and Back light.
These Clamp Meters are used in various industries across various sectors for maintenance and manufacturing
"MECO-G" has introduced a new series of Digital Clamp Meter in 3½ digit LCD display incorporating latest technology.
These clamp meters can measure AC Current, AC Voltage, DC Voltage, Resistance, Temperature and Frequency.
Additional Features include Diode Test, Continuity check, Data Hold and Back light.
These Clamp Meters are used in various industries across various sectors for maintenance and manufacturing