Synopsys Tech Pvt Ltd. Dahisar(W.), Mumbai, Maharashtra

GST Number : 27AATCS3987J1ZC
Contact Supplier Request A Quote
  • Conventional Water Leak Cable WD-CS

    Conventional Water Leak Cable WD-CS

    Request for Price

    Water Leak Detection Conventional System (WD-CS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.Features of Products : PVC twisted pair with stainless steel 316 elements. The cable is restorable and corrosion resistant and does not require replacement after being wet. Cable can be installed in the path of a potential water leak. Installation and Testing : Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel. Testing: Place a wet cloth over the WLD cable to stimulate a water leak. The length of cable in contact with wet cloth should be at least 3-inches. An alarm will be sent to WLD Panel. Dry the WLD Cable to restore in normal mode.

    Material : PVC Twisted Pair With Stainless Steel 316 Elements

    ...more
    Get Best Price
  • Addressable Water Leak Detection Cable WD-AS

    Addressable Water Leak Detection Cable WD-AS

    Request for Price

    Water Leak Detection Conventional System (WD-AS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.Features of Products : Water Leak Detection cable consists of four conductors, two water sensitive and two data. The cable is restorable and corrosion resistant and does not require replacement after being wet. Cable can be installed in the path of a potential water leak. Installation and Testing : Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel. Testing: Immerse the WLD cable in water to stimulate a water leak. An alarm will be sent to WLD Panel and the display the leak distance in meters. Dry the WLD Cable to restore in normal mode.

    Material : PVC Twisted Pair With Stainless Steel 316 Elements

    ...more
    Get Best Price
  • VAVA Annunciation Panel

    VAVA Annunciation Panel

    Request for Price

    Features of Products : Six potential free contact input for six events. At each event custom set message is displayed and prerecorded announcement is activated. Event messages can be edited by connecting IBM keyboard directly to the display. RS485 output for repeater. 2000 characters can be saved in memory.

    Power Consumption : 15 Watts.

    ...more
    Get Best Price
  • Digital Addressable Water Leak Detection System- SYNOPSYS

    Digital Addressable Water Leak Detection System- SYNOPSYS

    Request for Price

    The water leak system comprises of a Master Water leak detection panel (SY-3618), Distance locator Slave modules (MD-450), sensor cable (Synopsys WD-AS) and alarm sounders. The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and to extend alarm to the BMS.The MD-450 is locally placed in the Server rooms, and communicates with the Master Synopsys Panel through RS-485. It serves as an interface between the Master and the Sensor Cable. The Master panel SY-3618 is to be installed in the BMS room. The master panel will communicate with the clients BMS integration PC-side software using Modbus. The panel will activate a common sounder once the leak/fault is detected. The Master is equipped with a touch screen display and will display the name of the slave and the distance where the leak is been detected in meters. Salient Features :- Operates on 230V 50 HZ AC Has potential free output and LED indication. Displays distance to leak location in meters. Indicates cable break condition. Maximum length of linear leak detection cable is 150meters. Can detect leak anywhere along the entire cable length. Built in audio sounder and common hooter output. Easy to install and operate. Self-restoring. Soft membrane switches. Communicates with the Master using RS485.

    ...more
    Get Best Price
  • Water Leak Detection Touch Screen Conventional Panel Sy T103

    Water Leak Detection Touch Screen Conventional Panel Sy T103

    Request for Price

    The water leak system comprises of a touch screen water leak panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The WLD panel is enabled with a touch screen display, which makes the use of switches redundant.Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.Salient Features : The panel equipped with Touch Screen Display can monitor up to 8 Zones: Zone sensitivity feature is provided which enables the user to set the sensitivity of sensing cables as per the site requirements. Zone addressing facility is provided in the settings which enables the user to name the zones as per the site specifications. Zones can be isolated at Power on/Reset. Event log of 100 events is provided. Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system. Zone wise potential free relay output is provided for BMS. Compact and elegant looks. Panel is equipped with cable break condition where zone window turns blue in case if the cable is disconnected or if it breaks. Cable break condition is implemented in the system which will give an alarm for the zone whose cable has been damaged or removed. The respective zone window will turn blue.

    ...more
    Get Best Price
  • Standalone Rodent Repellent System

    Standalone Rodent Repellent System

    Request for Price

    They emit intensive sound at high audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected by the ultrasound.They do not get killed.The powerful sound waves generated by the transducers of RSCAT Repellents are within the hearing range of many pests and cause them pain and discomfort.Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.Location of RRS : Aim the RSCAT unit to the wall so that the sound will ‘bounce around’ and will reflect from walls, ceiling, room contents and floor and will be present throughout the area. Since ultrasound usually does not penetrate walls, it is important that it bounces around corners to cover larger areas. Plug the R-Scat unit into a 230Volts standard wall outlet. Extension cords may be used if necessary. The green LED will act as a breather; it will go on and off to indicate that the unit is working. Leave the RSCAT unit ON 24 hours a day. RSCAT units are designed for indoor use. If used outdoors they should be protected from the weather. Outdoors, there are fewer possibilities for reflection of ultrasound and many things that will absorb or dampen sound, their use is limited. Guarantee : RSCAT units are guaranteed for one year from the date of purchase by the user against defects in materials or workmanship.

    Power Supply : 230 Volts 50 HZ AC

    Power Consumption : 5 watt per transducer.

    Dimensions : 200(H) X 100(W) X 100(D) mm.

    Weight : 1125gms

    ...more
    Get Best Price
  • Single Door Hose Box

    Single Door Hose Box

    Request for Price

    Features of Products : The single door FRP hose box can accommodate maximum 15mtr wire. It is made from Fibre Glass material with ISO-Italic Resins. It has Al Powder coated with one extra key. It has two 40 X 3mm s.s. flat from top to bottom for extra strength. It has glass embedded in EPDM rubber gasket for easy fixing. FRP thickness will be 1.5-2.0mm. It comes in red color. All dimensions specified above are in mm. Hose Boxes come in M.S, Al and FRP.

    Material : Mild Steel

    Thickness : 0-15mm

    Door Style : Single

    ...more
    Get Best Price
  • RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System

    RSCAT TRND 500/500(Blinking LED) Transducer Rodent Repellent System

    Request for Price

    RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.Features : Each transducer covers an open area of 500 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 500 sq. feet. The same is possible because of the transducer's streaming effect design. Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor. Maximum Cable length per Rodent Console is 1000mtrs. Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking. The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks. The transducers do not need a power connection. The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.

    ...more
    Get Best Price
  • RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System

    RSCAT TRND 400/400(Blinking LED) Transducer Rodent Repellent System

    Request for Price

    RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.Features : Each transducer covers an open area of 400 Sq feet where the average height of the ceiling is 12 feet. Even when installed in the false ceiling or false floorings it will cover an area of 400 sq. feet. The same is possible because of the transducer's streaming effect design. Each transducer occupies a maximum space of 15 cubic.inches and aesthetically designed to match your décor. Maximum Cable length per Rodent Console is 1000mtrs. Being monopolar in nature. They can be installed in any sensitive area with zero risk of sparking. The transducers can withstand high temperatures in the false ceilings and low temperatures in cold storages and air locks. The transducers do not need a power connection. The transducers can be tested on an audible range independently, by selecting the Transducer testing menu from the LCD panel.

    ...more
    Get Best Price
  • RSCAT TRND 150/300 Transducer Rodent Repellent System

    RSCAT TRND 150/300 Transducer Rodent Repellent System

    Request for Price

    RSCAT UltrasonicPest Repellers are electronic transmitters of high frequency sound . They emit intensive sound at high decibel levelsthat is audible and painful to pests but inaudible to humans. The pests will usually leave the area being protected bythe ultrasound.They do not get killed.The powerful sound waves generated by the transducers of RSCAT repellers are within the hearing range of many pets and cause them pain and discomfort. Sometimes they will leave the area being protected immediately, in other cases it will take as long as two to three weeks before significant reduction in infestation occurs.RSCAT transducers are completely quiet. If you cannot hear do not thing that the unit is not working. You cannot hear ultrasound.Features :Crystal : Shall be similar to DM 44T 24V of MAS Germany. Visible Hexagonal, Triangle excitor – Centre damp horizontal line excitors. Frequency : Peak frequency responses of the satellites are, 21.6 KHz +/- 3 KHz 31.6 KHz +/- 3 KHz 50.4 KHz +/- 3 KHz 60 KHz +/- 3 KHz Nature Of Sound Waves: The sound waves propagated by the satellites shall be linear sine waves with constantly varying frequencies.

    Power Consumption : 5.5Watts per transducer.

    Power Supply : 230V AC/ 50Hz (15Amp Socket).

    ...more
    Get Best Price
  • R-Scat LCD24 Digital Rodent Repellent System

    R-Scat LCD24 Digital Rodent Repellent System

    Request for Price

    This revolutionary pest control unit turns your office into a fortress against rodents. High pressure Transducer emits a powerful ultrasonic sound that normal speakers are unable to emit.Much like a loud siren the sound intermittently attack pests to drive them out. R-Scat HFT uses a variable high frequency ultrasound so that pests do not get accustomed, the pest will leave the area being protected.R-Scat transducers work silently, humans can’t hear them so there is no discomfort to Humans.The panels are manufactured to the highest quality standards to meet the most stringent and diverse requirements. The panels are cost effective, reliable and easy to install & operateFeatures of Products : LCD Display with on board controls. Displays and configures Wave speed, Wave density, Frequency Band Time, Frequency Testing, Transducer Testing, Machine Controller/ID. Can connect upto 24 Transducers with blinking LED’s. The Transducer covers area of 500ft.in all voids i.e room void, above false ceiling and below false ceiling. All the Transducers are connected in a single loop. Self Testing facility of Transducer. Frequency band of Frequencies above 20KHZ and below 60 KHZ is per tuned for 100 different frequencies. Modbus output for BMS Communication.

    ...more
    Get Best Price
  • R-SCAT JAY JeLOOP20 Analog Rodent Repellent System

    R-SCAT JAY JeLOOP20 Analog Rodent Repellent System

    Request for Price

    This revolutionary pest control unit turns your office into a fortress against rodents. High pressure Transducer emits a powerful ultrasonic sound that normal speakers are unable to emit.Much like a loud siren the sound intermittently attack pests to drive them out. R-Scat HFT uses a variable high frequency ultrasound so that pests do not get accustomed, the pest will leave the area being protected.R-Scat transducers work silently, humans can’t hear them so there is no discomfort to Humans.The panels are manufactured to the highest quality standards to meet the most stringent and diverse requirements. The panels are cost effective, reliable and easy to install & operate.Features of Products : Upto 20 Transducers can be connected to main console. Transducers are looped in parallel thereby large reduction in cabling cost. Only two terminals for 20 transducers, easy to install and service. Self Testing facility of transducers. Wall mounted consoles. Compact and elegant look. User friendly controls. Technical Specification : Main Console : The Main Console can connect up to 20 Transducers (Satellites). The cabling from main console to Transducers is to be looped from one transducer to another. Area covered by each transducer : (Approximately) Room Void : 300 Sq. ft. Ceiling Void : 150 Sq. ft. Below false flooring : 150 Sq. ft.

    Power Consumption : 5.5Watts per transducer.

    Power Supply : 230V AC/ 50Hz (15Amp Socket).

    Dimensions : 200(W) x 90(H) x 415(D)mm

    Weight : 4.0 Kgs Approx.

    ...more
    Get Best Price
  • R-SCAT JAY Je4Z15 Analog Rodent Repellent System

    R-SCAT JAY Je4Z15 Analog Rodent Repellent System

    Request for Price

    This revolutionary pest control unit turns your office into a fortress against rodents. High pressure Transducer emits a powerful ultrasonic sound that normal speakers are unable to emit.Much like a loud siren the sound intermittently attack pests to drive them out. R-Scat HFT uses a variable high frequency ultrasound so that pests do not get accustomed, the pest will leave the area being protected.R-Scat transducers work silently, humans can’t hear them so there is no discomfort to Humans.The panels are manufactured to the highest quality standards to meet the most stringent and diverse requirements. The panels are cost effective, reliable and easy to install & operate.Features of Products : Upto 15 Transducers can be connected to main console. Transducers are looped in parallel thereby large reduction in cabling cost. Only two terminals for 15 transducers, easy to install and service. Self Testing facility of transducers. Wall mounted consoles. Compact and elegant look. User friendly controls. Technical Specification : Main Console : The Main Console contains 4 Panels in one box and can connect upto 60 Transducers (Satellites) in all. The cabling from main console to Transducers is to be looped from one transducer to another. Area covered by each transducer : (Approximately) Room Void : 300 Sq. ft. Ceiling Void : 150 Sq. ft. Below false flooring : 150 Sq. ft.

    Power Consumption : 5.5Watts per transducer.

    Power Supply : 230V AC/ 50Hz (15Amp Socket).

    Dimensions : 200(W) x 90(H) x 415(D) mm.

    Weight : 4 Kgs Approx.

    ...more
    Get Best Price
  • R-SCAT JAY Je1Z12 (ERTL) Analog Rodent Repellent System

    R-SCAT JAY Je1Z12 (ERTL) Analog Rodent Repellent System

    Request for Price

    This revolutionary pest control unit turns your office into a fortress against rodents. High pressure Transducer emits a powerful ultrasonic sound that normal speakers are unable to emit.Much like a loud siren the sound intermittently attack pests to drive them out. R-Scat HFT uses a variable high frequency ultrasound so that pests do not get accustomed, the pest will leave the area being protected.R-Scat transducers work silently, humans can’t hear them so there is no discomfort to Humans.The panels are manufactured to the highest quality standards to meet the most stringent and diverse requirements. The panels are cost effective, reliable and easy to install & operate.   Features of Products : Upto 12 Transducers can be connected to main console. ERTL Tested. Individual wiring for transducers. Self testing facility of transducers. Compact and elegant looks. User Friendly controls. The satellites do not need a power connection and they can be tested on an audible range with the help of a self-testing facility. Area covered by each transducer : (Approximately) Room Void : 300 Sq. ft. Ceiling Void : 150 Sq. ft. Below false flooring : 150 Sq. ft.

    Power Consumption : 5.5Watts per transducer

    Power Supply : 230V AC/ 50Hz (15Amp Socket)

    Dimensions : 200(W) x 90(H) x 415(D)mm

    Weight : 4.0 Kgs Approx.

    ...more
    Get Best Price
  • R-SCAT 24 BL Digital Rodent Repellent System

    R-SCAT 24 BL Digital Rodent Repellent System

    Request for Price

    This revolutionary pest control unit turns your office into a fortress against rodents. High pressure Transducer emits a powerful ultrasonic sound that normal speakers are unable to emit.Much like a loud siren the sound intermittently attack pests to drive them out. R-Scat HFT uses a variable high frequency ultrasound so that pests do not get accustomed, the pest will leave the area being protected.R-Scat transducers work silently, humans can’t hear them so there is no discomfort to Humans.The panels are manufactured to the highest quality standards to meet the most stringent and diverse requirements. The panels are cost effective, reliable and easy to install & operate.Features of Products : LCD Display with on board controls. R-Scat CRMS (Centralized Reporting and Monitoring System) Software supporting: Scheduled or Real Time health status report generation for Systems Audit. Parameter configuration of the controller. Two-way Communication between the controller and the computer. RS / EIA 485 to RS / EIA 232C converter to transfer the controller data to the serial port of your computer. Displays and configures Wave speed, Wave density, Frequency Band Time, Frequency Testing, Transducer Testing, Machine Controller/ID. Can connect upto 24 Transducers with blinking LED’s. The Transducer covers area of 500ft.in all voids i.e room void, above false ceiling and below false ceiling. Independent Drivers for each Transducer. Independent Test facility for each transducer. Frequency band of Frequencies above 20KHZ and below 60 KHZ is per tuned for 100 different frequencies.

    Weight : 5 Kgs Approx.

    ...more
    Get Best Price
  • Water Leak Detection Module Je 1141

    Water Leak Detection Module Je 1141

    Request for Price

    The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.Features of Products : Given an isolated supply AC supply to water leak cable to avoid oxidation or erosion of cables over a period of time. The module can be connected to water leak Detection Annunciation Panel. The module provides potential free relay output. The module comes in ABS enclosure. The module has compact and elegant looks.

    Supply Voltage : 230V AC – 50Hz +/- 10 %

    Response Time : < 3 Sec.

    Weight : 1kg (approx.)

    ...more
    Get Best Price
  • JE-190 Public Addressable System

    JE-190 Public Addressable System

    Request for Price

    Features of Products : The panel consists of 2 to 60 Zones. The panel complies with IS 2189 specification. The panel has separate fire and fault indications. The panel also has separate fire and common fault relay. The panel comprises of a 4Amp power supply unit. Battery backup is provided along with the AC supply. The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire. Technical Specification :INTERNAL POWER SUPPLY UNIT Constant potential battery charger 27.5V DC Adjustable. Output Current limited to 2 A. Low battery voltage monitored at 18 V DC Adjustable. Battery charger monitoring for failure. Mains supply monitoring for failure. Mains supply input voltage range 230V AC + or – 10 %, 50 Hz. Total panel quiescent current 50mA nominal. Approx. Standby time 4.5 AH 36 hrs. Battery recharge time from discharge 1 Hr. approx. INTERNAL RELAY CONTACT RATING Fire Relay 5 Amps S.P. 240 V DC. Common fault relay 5 Amps S.P. 240 V DC. Aux. Fire relay 5 Amps S.P. 240 V AC. Panel Indications : System ON Green LED - System normal. Common Fault Amber LED – Internal buzzer will sound intermittently. Common Fire Red LED - Detector activated. Zone fault Amber LED – Indicates zone wiring and detector faults. Zone fire Red LED – indicates zone where fire has been detected. AC fail Amber LED – Indicates loss of mains. DC fail Amber LED – Indicates battery fault. Batt. Low Amber LED – Indicates battery supply below 18V DC. External Controls : Sound : To sound external as well as internal sounders. Silence : To silence external as well as internal sounders. Reset : Lamp test & resets the panels. Isolate : The zone to add/clean detectors. Test : International standard walk test. Auto/manual : Amplifier in auto/manual mode. Volume : Increase/ decrease amplifier volume. Call All : Announcement to all zones simultaneously. Selected switch for individual zone announcement.

    ...more
    Get Best Price
  • JE-1141 Public Addressable System

    JE-1141 Public Addressable System

    Request for Price

    Features of Products : The panel consists of 2 to 60 Zones. The panel complies with IS 2189 specification. The panel has separate fire and fault indications. The panel also has separate fire and common fault relay. The panel comprises of a 4Amp power supply unit. Battery backup is provided along with the AC supply.(Optional) The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire. Technical Specification :INTERNAL POWER SUPPLY UNIT Constant potential battery charger 27.5V DC Adjustable Output Current limited to 2 A Mains supply input voltage range 230V AC + or – 10 %, 50 Hz Total panel quiescent current 50mA nominal Approx. Standby time 4.5 AH 36 hrs. Battery recharge time from discharge 1 Hr. approx. INTERNAL RELAY CONTACT RATING Fire Relay 5 Amps S.P. 240 V DC Common fault relay 5 Amps S.P. 240 V DC Aux. Fire relay 5 Amps S.P. 240 V AC Panel Indications : System ON Green LED - System normal Common Fault Amber LED – Internal buzzer will sound intermittently Common Fire Red LED - Detector activated Zone fault Amber LED – Indicates zone wiring and detector faults Zone fire Red LED – indicates zone where fire has been detected External Controls : Sound - To sound external as well as internal sounders. Silence - To silence external as well as internal sounders. Reset - Lamp test & resets the panels. Auto/manual - Amplifier in auto/manual mode. Volume - Increase/ decrease amplifier volume. Call All - Announcement to all zones simultaneously.

    ...more
    Get Best Price
  • Water Leak Detection Conventional Panel ... JAY 3523

    Water Leak Detection Conventional Panel ... JAY 3523

    Request for Price

    The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.Features of Products : The panel equipped with LCD Display can monitor 20 Zones. Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system. The panel is equipped with SPDT keypad for navigation. Compact and elegant looks.

    Supply Voltage : 230V AC – 50Hz +/- 10 %

    Response Time : < 3 Sec.

    Weight : 3 Kgs Aprrox.

    ...more
    Get Best Price
  • Jay Je-190 (ERTL) Conventional Fire Alarm Panel

    Jay Je-190 (ERTL) Conventional Fire Alarm Panel

    Request for Price

    Features of Products : The panel ranges from 2 to 64 zones. The panel complies with IS 2189 specification. The panel has separate fire and fault indications. The panel also has separate fire and common fault relay. The panel comprises of a 2Amp powe supply unit. Battery backup is provided along with the AC supply. The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire. Technical Specification :INTERNAL POWER SUPPLY UNIT Constant potential battery charger 27.5V DC Adjustable. Output Current limited to 2 A. Low battery voltage monitored at 18 V DC Adjustable. Battery charger monitoring for failure. Mains supply monitoring for failure. Mains supply input voltage range 230V AC + or – 10 %, 50 Hz. Total panel quiescent current 50mA nominal. Approx. Standby time 4.5 Ah Batt. 36 hrs. Battery recharge time from discharge 1 Hr. approx. INTERNAL RELAY CONTACT RATING Fire Relay 5 Amp. S.P. 240 V DC. Common fault relay 5 Amp. S.P. 240 V DC. Aux. Fire relay 5 Amp. S.P. 240 V AC. Panel Indications : System ON Green LED - System normal. Common Fault Amber LED – Internal buzzer will sound intermittently. Common Fire Red LED - Detector activated. Zone fault Amber LED – Indicates zone wiring and detector faults. Zone fire Red LED – indicates zone where fire has been detected. AC fail Amber LED – Indicates loss of mains. DC fail Amber LED – Indicates battery fault. Batt. Low Amber LED – Indicates battery supply below 18V DC External Controls : Sound : To sound external as well as internal sounders. Silence : To silence external as well as internal sounders. Reset : Lamp test & resets the panels. Isolate : The zone to add/clean detectors. Test : International standard walk test.

    ...more
    Get Best Price
  • Jay JE-1141 Conventional Fire Alarm Panel

    Jay JE-1141 Conventional Fire Alarm Panel

    Request for Price

    Features of Products : The panel ranges from 2 to 64 zones. The panel complies with IS 2189 specification. The panel has separate fire and fault indications. The panel also has separate fire and common fault relay. The panel comprises of a 4Amp powe supply unit. Battery backup is provided along with the AC supply. Technical Specification :INTERNAL POWER SUPPLY UNIT Constant potential battery charger 14.5V DC. Output Current limited to 3 A. Mains supply input voltage range 230V AC + or – 10 %, 50 Hz. Total panel quiescent current 50mA nominal. Approx. Standby time 4.5 Ah Batt. 24 hrs. Battery recharge time from discharge 3 Hr. approx. INTERNAL RELAY CONTACT RATING Fire Relay 5 Amp. S.P. 240 V DC. Panel Indications : System ON Green LED - System normal. Fire Red LED – MCP/Detector activated. Zone fault Amber LED – Indicates zone wiring detector fault. Zone fire Red LED – indicates zone where fire has been detected. External Controls : Sound : To sound external as well as internal sounders. Silence : To silence external as well as internal sounders. Reset : Lamp test & resets the panels.

    Size : 375 (H) mm x 300 (W) mm x 100 (D) mm

    Material : M.s. Powder Coated.

    ...more
    Get Best Price
  • Gas Release Conventional Fire Alarm Panel

    Gas Release Conventional Fire Alarm Panel

    Request for Price

    Functions : After fire in both the zones following operation takes place in sequence, the timer starts. The delay can be set from 0 to 250 sec with the help of dip switch. The Panels Timer LED On and potential Free Timer Relay operates. After the delay is over, relay of solenoid valve operates, 24 V DC output for Solenoid valve and potential Free Gas Release relay also operates.Abort : After cross zoning the time delay starts and for some reason we do not want to release gas, then short the terminals of ABORT and timer stops. Abort LED on the Panel will glow. Once we release Abort switch then again Timer starts and after set delay, relay of solenoid valve operates.Manual Release : The Manual release can be achieved by shorting manual release terminals and with set time delay, relay of solenoid valve operates.Features of Products : Operates on 230V supply with battery backup with built in charging. Low battery visual warning with audible tone. LED indication for Timer On, Abort and Gas Release. Relay output for actuators. Zone disable facility. Solenoid Output with time delay. Made from M.S. CRCA rugged with powder coated finish.

    ...more
    Get Best Price
  • Digital Addressable Water Leak Detection Panel

    Digital Addressable Water Leak Detection Panel

    Request for Price

    This water leak system comprises of a Distance Locator panel, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.Features of Products : The Distance Locator Panel operates on 230V AC supply with battery backup. It will provide supervision of interface modules The features of the Synopsys Distance Locator panel are as follows: LCD Display to indicate the module number and the distance to leak location in meters. The panel also displays a cable fault in case of cable break condition. A modbus output is provided for BMS communication. The system is equipped with a built-in audible sounder and a common hooter. A common relay output is given along with the common alarm relay out.

    Weight : 3 Kgs Approx

    Supply Voltage : 230V AC – 50Hz +/- 10 %

    Dimensions : 250(H) X 250(W) X 110(D) mm.

    ...more
    Get Best Price
  • double door hose box

    double door hose box

    Request for Price

    Features of Products : The double door FRP hose box can accommodate maximum 15mtr wire and one branch pipe. It is made from Fibre Glass material with ISO-Italic Resins. It has Al Powder coated handle & S.S./brass hinges with brass screws. It has two 40 X 3mm S.S. flat from top to bottom for extra strength. It has glass/acrylic sheet on door embedded in EPDM rubber gasket for easy fixing. FRP thickness will be 1.5-2.0mm. It comes in red color. All dimensions specified above are in mm. Hose Boxes come in M.S, Al and FRP.

    Frequency : 50Hz, 60Hz

    ...more
    Get Best Price

Average Customer Rating


5 / 5

Business Rating


5 1
4 0
3 0
2 0
1 0
Write a Review

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers
  • GSTIN Number 27AATCS3987J1ZC

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Synopsys Tech Pvt Ltd. from Mumbai, Maharashtra is Retailer of [Fire Fighting & Protection] - Fire Alarm Panel, Fire Hose Boxes, Gas Release Conventional Fire Alarm Panel, Jay Je-190 (ERTL) Conventional Fire Alarm Panel, Jay JE-1141 Conventional Fire Alarm Panel, [Instrumentation & Control Equipment] - SY-T103 Touch Screen Conventional Panel, [Security and Inspection Devices] - Analog Annunciator Panel.
Read More »

Contact Information

Synopsys Tech Pvt Ltd.

  • Mr. Amit Adhia
  • A-001, Fressia CHS LTD, Baburao Ranade Marg, Off. L.M. Road, Behind Bank of India, Dahisar(W.), Mumbai, Maharashtra
  • http://www.jayfiresystems.co.in
top