Standard equipment's operating conditions
25°C / 60%RH 30°C / 65%RH 40°C / 75%RH 30°C / 75%RH
Standard equipment's operating conditions
25°C / 40%RH 30°C / 35%RH 40°C / 25%RH
Panel Construction
Tongue and groove type PUF insulated sandwich panel with cam lock. The Equipment interior is constructed with stainless steel 304 grade finish-4 and exterior is constructed with pre coated GI sheet/ stainless steel 304 grade finish-4.
Tray and Rack
Duly electro polished stainless steel wire mesh tray and heavy duty square pipe rack with adjustable tray location.
Door
Heavy duty toughened double glass door installed with imported hinges and lock for easy operation.
Backup System
Equipment is installed with PLC based auto change over backup system for Refrigeration system and Steam Generator system.
PLC based control system
Advanced PLC program with built-in Auto-Tuning, PLC Processor based computing and Interactive Easy-to-Use HMI.
Documentation
• Equipment : DQ, IQ, OQ with PLC Validation, PQ-Conforming to ISPE recommendations, User Manual • Software : IQ, OQ, User Manual
Standard equipment's operating conditions
25°C / 60%RH 30°C / 65%RH 40°C / 75%RH 30°C / 75%RH
Standard equipment's operating conditions
25°C / 40%RH 30°C / 35%RH 40°C / 25%RH
Panel Construction
Tongue and groove type PUF insulated sandwich panel with cam lock. The Equipment interior is constructed with stainless steel 304 grade finish-4 and exterior is constructed with pre coated GI sheet/ stainless steel 304 grade finish-4.
Tray and Rack
Duly electro polished stainless steel wire mesh tray and heavy duty square pipe rack with adjustable tray location.
Door
Heavy duty toughened double glass door installed with imported hinges and lock for easy operation.
Backup System
Equipment is installed with PLC based auto change over backup system for Refrigeration system and Steam Generator system.
PLC based control system
Advanced PLC program with built-in Auto-Tuning, PLC Processor based computing and Interactive Easy-to-Use HMI.
Documentation
• Equipment : DQ, IQ, OQ with PLC Validation, PQ-Conforming to ISPE recommendations, User Manual • Software : IQ, OQ, User Manual
• Controlling system- PLC
• Communication via Ethernet
• PLC based auto tune facility
• User based Alphanumeric password protection through HMI
• Stand-alone - 4.3” HMI with TFT LCD Colour touch screen
• Walk-in Chamber - 7” HMI with TFT LCD Colour touch screen
• PLC Based Safety cut off
• Rotronic make 4 to 20 mA sensors
• Controlling system- PLC
• Communication via Ethernet
• PLC based auto tune facility
• User based Alphanumeric password protection through HMI
• Stand-alone - 4.3” HMI with TFT LCD Colour touch screen
• Walk-in Chamber - 7” HMI with TFT LCD Colour touch screen
• PLC Based Safety cut off
• Rotronic make 4 to 20 mA sensors
Panel Construction
Tongue and groove type PUF insulated sandwich panel with cam lock. The Equipment interior is constructed with stainless steel 304 grade finish-4 and exterior is constructed with pre coated GI sheet/ stainless steel 304 grade finish-4.
Construction
Double wall inner tank and outer body is dynamically designed from strength and working point of view. The Equipment interior is constructed with stainless steel 304 grade mirror finish and exterior is constructed with powder coated GI sheet/ stainless steel 304 grade finish-4.
Tray
Stainless steel perforated tray with intervals of ½" height adjustment for better sample storage.
Door
Heavy duty outer insulated door installed with imported hinges and lock for easy operation and inner glass door with latch to observe samples without disturbing the set condition.
UV & Florescent lights
• As per ICH Guidelines-1.2 Million Lux/Hours of visible light and 200 watt Hr/m2 of UV light. Auto shut Off after specified exposure level.
• Individual PLC based timer is provided to switch ON/OFF UV and Florescent lights as required.
• UV light is switched off automatically once inner glass door is opened.
• Samples can be tested under Fluorescent light or U.V. lights separately as well as combine.
PLC based control system
• 4.3” HMI with TFT LCD Colour touch screen
• Communication via Ethernet
• PLC based auto tune facility
• PLC Based Safety cut off
• User based Alphanumeric password protection through HMI
• Rotronic make 4 to 20 mA sensors
Panel Construction
Tongue and groove type PUF insulated sandwich panel with cam lock. The Equipment interior is constructed with stainless steel 304 grade finish-4 and exterior is constructed with pre coated GI sheet/ stainless steel 304 grade finish-4.
Construction
Double wall inner tank and outer body is dynamically designed from strength and working point of view. The Equipment interior is constructed with stainless steel 304 grade mirror finish and exterior is constructed with powder coated GI sheet/ stainless steel 304 grade finish-4.
Tray
Stainless steel perforated tray with intervals of ½" height adjustment for better sample storage.
Door
Heavy duty outer insulated door installed with imported hinges and lock for easy operation and inner glass door with latch to observe samples without disturbing the set condition.
UV & Florescent lights
• As per ICH Guidelines-1.2 Million Lux/Hours of visible light and 200 watt Hr/m2 of UV light. Auto shut Off after specified exposure level.
• Individual PLC based timer is provided to switch ON/OFF UV and Florescent lights as required.
• UV light is switched off automatically once inner glass door is opened.
• Samples can be tested under Fluorescent light or U.V. lights separately as well as combine.
PLC based control system
• 4.3” HMI with TFT LCD Colour touch screen
• Communication via Ethernet
• PLC based auto tune facility
• PLC Based Safety cut off
• User based Alphanumeric password protection through HMI
• Rotronic make 4 to 20 mA sensors
Measured with high accuracy data-logger at sample storage area with standard Set Point.
Custom built Chambers are available in any dimensions and capacities.
Measured with high accuracy data-logger at sample storage area with standard Set Point.
Custom built Chambers are available in any dimensions and capacities.
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Established in the year 2010, ALLYONE is engaged in manufacturing of pharma and scientific equipments. All our products are uniquely designed, manufactured and tested to deliver highest levels of performance, extended durability and optimum efficiency, duly proven and experienced by our valued customers. A well laid infrastructural set up with the latest technological advancements has enabled us to meet the voluminous demand of customers across the globe. Our complete manufacturing process follows a purely professional approach that involves a strong team of highly skilled and experienced engineers and workmen who aim their knowledge and efforts at maximizing overall profitability and growth. Accentuating on achieving high quality and streamlining the manufacturing process, we stay ahead of our competitors by providing our clients with a one-stop solution for their requirements.