  • Underground Optical Fibre Cables

    Underground Optical Fibre Cables

    Get Latest Price

    • ArmouredUnarmoured
    • Construction Details: Multiloose Tube Cables (2f -144f) number of Elements (2f to 72f) 6 Nos (144f ) 8 Nos tube/fibre Identification : Colour Coded central Strength Member : Fibre Reinforced Plastic (frp) fibre Protection (tubes : Polybutylene Terephthalate (pbt) fillers as Required Water Blocking. Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape armour corrugated Steel Tape Armoured Cables * Option Available for Unarmoured Cables with or Without Pa-12 Jacket ** Option of Ribbon Cables Available for High Fibre Count construction Details: Unitube Cables ( 2f -24f) number of Fibres per Tube : 24 Nos fibre Identification Colour Coded strength Member Frp Rod / Steel Wire Embedded in Sheath fibre Protection (tubes) Polybutylene Terephthalate (pbt) water Blocking Thixotropic Gel (tubes) / Water Swellable Tape sheath Polyethylene * Option Available for Unarmoured Cables with Pa-12 Jacket and Corrugated Steel Tape Armoured Cables.\ specifications : Iec 60794 for Mechanical & Environmental Testing.
    ...more
  • Underground Optical Fibre Cables

    Underground Optical Fibre Cables

    Request for Price

    Construction Details: Multiloose Tube Cables (2f -144f) number of Elements (2f to 72f) 6 Nos (144f ) 8 Nos tube/fibre Identification : Colour Coded central Strength Member : Fibre Reinforced Plastic (frp) fibre Protection (tubes : Polybutylene Terephthalate (pbt) fillers as Required Water Blocking. Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape armour corrugated Steel Tape Armoured Cables * Option Available for Unarmoured Cables with or Without Pa-12 Jacket ** Option of Ribbon Cables Available for High Fibre Count construction Details: Unitube Cables ( 2f -24f) number of Fibres per Tube : 24 Nos fibre Identification Colour Coded strength Member Frp Rod / Steel Wire Embedded in Sheath fibre Protection (tubes) Polybutylene Terephthalate (pbt) water Blocking Thixotropic Gel (tubes) / Water Swellable Tape sheath Polyethylene * Option Available for Unarmoured Cables with Pa-12 Jacket and Corrugated Steel Tape Armoured Cables.\ specifications : Iec 60794 for Mechanical & Environmental Testing.

    ...more
    Get Best Price
  • Underground Copper Telecom Cables

    Underground Copper Telecom Cables

    Get Latest Price

    Copper: Annealed Electrolytic Copper Conductor with Various Diameter Ranging from 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Foam Skin / Cellular / Solid Hdpe Insulation as per Astm D 1248 and Bs 6234. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length. Cable is Assembled By Stranding of 10 Pairs or 20 Pairs or 25 Pairs Basic Subunit. filling Compound: a Moisture Resistant Filling Compound is Applied to Completely Coat the Insulated Conductors and Fill the Interstices Between Pairs and Units, to Avoid the Seepage of Water from Inside the Cables. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core. sheath: Black Polyethylene Sheath is Extruded Over the Screen. specifications: Iec 60794 for Mechanical & Environmental Testing.
    ...more
  • Underground Copper Telecom Cables

    Underground Copper Telecom Cables

    Request for Price

    Copper: Annealed Electrolytic Copper Conductor with Various Diameter Ranging from 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Foam Skin / Cellular / Solid Hdpe Insulation as per Astm D 1248 and Bs 6234. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length. Cable is Assembled By Stranding of 10 Pairs or 20 Pairs or 25 Pairs Basic Subunit. filling Compound: a Moisture Resistant Filling Compound is Applied to Completely Coat the Insulated Conductors and Fill the Interstices Between Pairs and Units, to Avoid the Seepage of Water from Inside the Cables. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core. sheath: Black Polyethylene Sheath is Extruded Over the Screen. specifications: Iec 60794 for Mechanical & Environmental Testing.

    ...more
    Get Best Price
  • Optical Fibre Cables

    Optical Fibre Cables

    Get Latest Price

    Type of the Cable : Duct, Direct Burial, Aerial number of Fibre 2 - 144 Fibre Count fibre Type itu-t G 652, G 652 C, G 652 D, G 653, G 654, G 655 loose Tube Material pbtp, Nylon water Resistance Thixotropic Jelly strength Members frp, Aramid Yarn, Glass Fibre Reinforcements, Steel Wire moisture Barrier water Swellable Tape, Flooding Jelly armouring Material copolymer Coated S. S. Tape, Copolymer Coated Eccs Tape sheath / Jacket Compound hdpe (anti-termite or Normal), Polyamide-12 temperature of Operation ( ° C) – 40 to + 70.
    ...more
  • Optical Fibre Cables

    Optical Fibre Cables

    Request for Price

    Type of the Cable : Duct, Direct Burial, Aerial number of Fibre 2 - 144 Fibre Count fibre Type itu-t G 652, G 652 C, G 652 D, G 653, G 654, G 655 loose Tube Material pbtp, Nylon water Resistance Thixotropic Jelly strength Members frp, Aramid Yarn, Glass Fibre Reinforcements, Steel Wire moisture Barrier water Swellable Tape, Flooding Jelly armouring Material copolymer Coated S. S. Tape, Copolymer Coated Eccs Tape sheath / Jacket Compound hdpe (anti-termite or Normal), Polyamide-12 temperature of Operation ( ° C) – 40 to + 70.

    ...more
    Get Best Price
  • Tinned Copper Conductor

    Tinned Copper Conductor

    Get Latest Price

    Copper: Annealed Electrolytic Plain / Tinned Copper Conductor with Various Diameter of 0.4mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Solid Hdpe / Pvc Insulation. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length .cable is Assembled By Stranding of 10 Pairs / 20pairs or 25 Pairs Basic Subunit. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. sheath: Pvc / Frls Pvc / Pe Sheath in Grey / White / Green / Black Colour is Extruded Over the Cable Core.
    ...more
  • Tinned Copper Conductor

    Tinned Copper Conductor

    Request for Price

    Copper: Annealed Electrolytic Plain / Tinned Copper Conductor with Various Diameter of 0.4mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Solid Hdpe / Pvc Insulation. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length .cable is Assembled By Stranding of 10 Pairs / 20pairs or 25 Pairs Basic Subunit. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. sheath: Pvc / Frls Pvc / Pe Sheath in Grey / White / Green / Black Colour is Extruded Over the Cable Core.

    ...more
    Get Best Price
  • Copper Communication Cables

    Copper Communication Cables

    Get Latest Price

    Parameters conductor Size (mm) 0.4 0.5 0.63 0.9 conductor Resistance (per Km in Ohms.) individual 135 ± 8 86 ± 6 58 ± 4 28 ± 2 conductor Resistance Unbalance (%) individual 3 2.5 2 2 average 1.5 1 1 1 conductor Elongation (minimum %) 15 15 18 18 attenuation At 150 Khz (db/km) Shall Not Exceed 12 8.25 6.3 4.4 insulation Solid (mdpe/hdpe) spark Test 3 Kv Rms Ac, 1 Spark per 5 K.m. retraction of Insulation (shall Not Exceed) 2.5 Mm After 1 Min resistance to Compression 200 N, 12 V Dc insulation Resistance At 500v5000 Mega Ohm – Km construction 10/20 Pair Units & 50/100 Pair Super Units of Sizes: 10 Pair to 2400 Pairs filling Compound water Resistant Compound (petro Jelly) core polyester Tape moisture Barrier Poly – Aluminium sheath / Jacket Ldpe armouring Galvanised Steel Tape armouring Bedding Pe Tape mutual Capacitance (nf/km) individual 52 ± 4.5 average 52 ± 3 capacitance Unbalance (pf/km) individual 3000 Pf average 750 Pf far End Cross Talk (db) At 150 Khz, Better Than 67.8 Rms Indvl. 55 Rms near End Cross Talk (db) At 150 Khz better Than 55 Rms (individual Value) pairs from 5 Pairs to 2400 Pairs.
    ...more
  • Copper Communication Cables

    Copper Communication Cables

    Request for Price

    Parameters conductor Size (mm) 0.4 0.5 0.63 0.9 conductor Resistance (per Km in Ohms.) individual 135 ± 8 86 ± 6 58 ± 4 28 ± 2 conductor Resistance Unbalance (%) individual 3 2.5 2 2 average 1.5 1 1 1 conductor Elongation (minimum %) 15 15 18 18 attenuation At 150 Khz (db/km) Shall Not Exceed 12 8.25 6.3 4.4 insulation Solid (mdpe/hdpe) spark Test 3 Kv Rms Ac, 1 Spark per 5 K.m. retraction of Insulation (shall Not Exceed) 2.5 Mm After 1 Min resistance to Compression 200 N, 12 V Dc insulation Resistance At 500v5000 Mega Ohm – Km construction 10/20 Pair Units & 50/100 Pair Super Units of Sizes: 10 Pair to 2400 Pairs filling Compound water Resistant Compound (petro Jelly) core polyester Tape moisture Barrier Poly – Aluminium sheath / Jacket Ldpe armouring Galvanised Steel Tape armouring Bedding Pe Tape mutual Capacitance (nf/km) individual 52 ± 4.5 average 52 ± 3 capacitance Unbalance (pf/km) individual 3000 Pf average 750 Pf far End Cross Talk (db) At 150 Khz, Better Than 67.8 Rms Indvl. 55 Rms near End Cross Talk (db) At 150 Khz better Than 55 Rms (individual Value) pairs from 5 Pairs to 2400 Pairs.

    ...more
    Get Best Price
  • CAT Cables

    CAT Cables

    Get Latest Price

    Copper: Annealed electrolytic copper conductor with diameter of 0.4mm & 0.5 mm as per IEC28 and ASTM B3. Insulation: Conductor insulation is Solid HDPE insulation. Cable Core: Two insulated conductors are twisted together to form a pair with uniform specific lay length .Cable is assembled by stranding of 5 Pairs, 10 pairs & 20pairs basic subunit. Core wrapping: A non hygroscopic and dielectric polyester film is applied helically over the cable core. Sheath: PVC / FRLS PVC / PE Sheath is extruded over the cable core. Option of Water Blocking tape in place of Polyester & Yarns is also available. Option of Aerial Fig-8, CAT - 3 cable upto 100 Pairs for Aerial applications is also available.
    ...more
  • CAT Cables

    CAT Cables

    Request for Price

    Copper: Annealed electrolytic copper conductor with diameter of 0.4mm & 0.5 mm as per IEC28 and ASTM B3. Insulation: Conductor insulation is Solid HDPE insulation. Cable Core: Two insulated conductors are twisted together to form a pair with uniform specific lay length .Cable is assembled by stranding of 5 Pairs, 10 pairs & 20pairs basic subunit. Core wrapping: A non hygroscopic and dielectric polyester film is applied helically over the cable core. Sheath: PVC / FRLS PVC / PE Sheath is extruded over the cable core. Option of Water Blocking tape in place of Polyester & Yarns is also available. Option of Aerial Fig-8, CAT - 3 cable upto 100 Pairs for Aerial applications is also available.

    ...more
    Get Best Price
  • Broadband Cables

    Broadband Cables

    Get Latest Price

    Construction Details: Multiloose Tube Cables ( 2f - 96f) number of Elements (2f to 72f)6 Nos ( 96f )8 Nos tube/fibre Identification : Colour Coded central Strength Member : Fibre Reinforced Plastic (frp) fibre Protection (tubes)polybutylene Terephthalate (pbt) fillers as Required water Blocking Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape peripheral Strength Members : Aramid Yarns sheath pvc / Pe / Lszh * Option Available for Jelly Filled Cables construction Details: Unitube Cables (2f -24f) number of Fibres per Tube 24 Nos. fibre Identification : Colour Coded strength Member frp / Arp Rod / Steel Wire Embedded in Sheath fibre Protection (tubes)polybutylene Terephthalate (pbt) fillers as Required water Blocking thixotropic Gel (tubes) / Tape sheath pvc / Polyethylene / Lszh * Option Available for Jelly Filled Cables / Flat Cables specifications : Iec 60794 for Mechanical & Environmental Testing.
    ...more
  • Broadband Cables

    Broadband Cables

    Request for Price

    Construction Details: Multiloose Tube Cables ( 2f - 96f) number of Elements (2f to 72f)6 Nos ( 96f )8 Nos tube/fibre Identification : Colour Coded central Strength Member : Fibre Reinforced Plastic (frp) fibre Protection (tubes)polybutylene Terephthalate (pbt) fillers as Required water Blocking Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape peripheral Strength Members : Aramid Yarns sheath pvc / Pe / Lszh * Option Available for Jelly Filled Cables construction Details: Unitube Cables (2f -24f) number of Fibres per Tube 24 Nos. fibre Identification : Colour Coded strength Member frp / Arp Rod / Steel Wire Embedded in Sheath fibre Protection (tubes)polybutylene Terephthalate (pbt) fillers as Required water Blocking thixotropic Gel (tubes) / Tape sheath pvc / Polyethylene / Lszh * Option Available for Jelly Filled Cables / Flat Cables specifications : Iec 60794 for Mechanical & Environmental Testing.

    ...more
    Get Best Price
  • Aerial Optical Fibre Cables

    Aerial Optical Fibre Cables

    Get Latest Price

    We are Offering Aerial Optical Fibre Cables. construction Details: Multiloose Tube Cables (2f - 96f) number of Elements (2f to 72f) 6 Nos ( 96f ) 8 Nos tube/fibre Identification Colour Coded central Strength Member Fibre Reinforced Plastic (frp) fibre Protection (tubes) Polybutylene Terephthalate (pbt) fillers as Required water Blocking Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape sheath Polyethylene peripheral Strength Member aramid Yarns * Option Available for Unitube Adss Cables construction Details: Multiloose Tube Cables ( 2f - 96f) number of Elements (2f to 72f) 6 Nos ( 96f ) 8 Nos tube/fibre Identification Colour Coded central Strength Member Fibre Reinforced Plastic (frp) fibre Protection (tubes) Polybutylene Terephthalate (pbt) fillers as Required water Blocking thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape sheath Polyethylene suspension Strand 7 Wire Galvanized Steel Strand * Option Available for Unitube Fig-8 Aerial Cables specifications : Iec 60794 for Mechanical & Environmental Testing.
    ...more
  • Aerial Optical Fibre Cables

    Aerial Optical Fibre Cables

    Request for Price

    We are Offering Aerial Optical Fibre Cables. construction Details: Multiloose Tube Cables (2f - 96f) number of Elements (2f to 72f) 6 Nos ( 96f ) 8 Nos tube/fibre Identification Colour Coded central Strength Member Fibre Reinforced Plastic (frp) fibre Protection (tubes) Polybutylene Terephthalate (pbt) fillers as Required water Blocking Thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape sheath Polyethylene peripheral Strength Member aramid Yarns * Option Available for Unitube Adss Cables construction Details: Multiloose Tube Cables ( 2f - 96f) number of Elements (2f to 72f) 6 Nos ( 96f ) 8 Nos tube/fibre Identification Colour Coded central Strength Member Fibre Reinforced Plastic (frp) fibre Protection (tubes) Polybutylene Terephthalate (pbt) fillers as Required water Blocking thixotropic Gel (tubes) / Jelly (interstices) core Wrapping Polyester Tape sheath Polyethylene suspension Strand 7 Wire Galvanized Steel Strand * Option Available for Unitube Fig-8 Aerial Cables specifications : Iec 60794 for Mechanical & Environmental Testing.

    ...more
    Get Best Price
  • Aerial Copper Telecom Cables

    Aerial Copper Telecom Cables

    Get Latest Price

    Copper: Annealed Electrolytic Copper Conductor with Various Diameter of 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Solid Hdpe / Foam Skin / Cellular Insulation as per Astm D 1248 and Bs 6234. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length . Cable is Assembled By Stranding of 10 Pairs / 20 Pairs or 25 Pairs Basic Subunit. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core. suspension Strand: 7 Wire Suspension Strand is Made Integral Part of the Cable and a Common Sheath is Provided Over Cable Core and Suspension Strand. sheath: Black Polyethylene Sheath is Extruded Over the Screen. jelly Filled Cable Option also Available.
    ...more
  • Aerial Copper Telecom Cables

    Aerial Copper Telecom Cables

    Request for Price

    Copper: Annealed Electrolytic Copper Conductor with Various Diameter of 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3. insulation: Conductor Insulation are Solid Hdpe / Foam Skin / Cellular Insulation as per Astm D 1248 and Bs 6234. cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length . Cable is Assembled By Stranding of 10 Pairs / 20 Pairs or 25 Pairs Basic Subunit. core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core. moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core. suspension Strand: 7 Wire Suspension Strand is Made Integral Part of the Cable and a Common Sheath is Provided Over Cable Core and Suspension Strand. sheath: Black Polyethylene Sheath is Extruded Over the Screen. jelly Filled Cable Option also Available.

    ...more
    Get Best Price

Be first to Rate

Rate This

Choose the service or product you're reviewing for this business

How would you rate the business?

What did you like and dislike?

  • Response
  • Delivery
  • Quality

Tell us about your experience?

About the Company

  • Primary Business Retailer
  • Secondary Business Type Wholesale Suppliers
  • Year of Establishment 2010
  • No. of Employees 6 - 20
  • Annual Turnover Below Rs. 0.5 Crore Approx.

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Vantage Telecommunications from Pune, Maharashtra Established in 2010 is Retailer of Aerial Copper Telecom Cables, Indoor Copper Telecom Cables, CAT Cables, Underground Copper Telecom Cables, Underground Optical Fibre Cables, Aerial Optical Fibre Cables, Broadband Cables, Optical Fibre Cables, Copper Communication Cables.
Read More »

Contact Information

Vantage Telecommunications

  • Mr. S Kumar
  • A-4/204, Oxford Village, Wanowri, Wanowrie, Pune, Maharashtra