Construction Details: Multiloose Tube Cables (2f -144f)
number of Elements (2f to 72f) 6 Nos
(144f ) 8 Nos
tube/fibre Identification : Colour Coded
central Strength Member : Fibre Reinforced Plastic (frp)
fibre Protection (tubes : Polybutylene Terephthalate (pbt)
fillers as Required Water Blocking. Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
armour
corrugated Steel Tape Armoured Cables
* Option Available for Unarmoured Cables with or Without Pa-12 Jacket
** Option of Ribbon Cables Available for High Fibre Count
construction Details: Unitube Cables ( 2f -24f)
number of Fibres per Tube : 24 Nos
fibre Identification Colour Coded
strength Member Frp Rod / Steel Wire Embedded in Sheath
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
water Blocking Thixotropic Gel (tubes) / Water Swellable Tape
sheath Polyethylene
* Option Available for Unarmoured Cables with Pa-12 Jacket and Corrugated Steel Tape Armoured Cables.\
specifications : Iec 60794 for Mechanical & Environmental Testing.
Construction Details: Multiloose Tube Cables (2f -144f)
number of Elements (2f to 72f) 6 Nos
(144f ) 8 Nos
tube/fibre Identification : Colour Coded
central Strength Member : Fibre Reinforced Plastic (frp)
fibre Protection (tubes : Polybutylene Terephthalate (pbt)
fillers as Required Water Blocking. Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
armour
corrugated Steel Tape Armoured Cables
* Option Available for Unarmoured Cables with or Without Pa-12 Jacket
** Option of Ribbon Cables Available for High Fibre Count
construction Details: Unitube Cables ( 2f -24f)
number of Fibres per Tube : 24 Nos
fibre Identification Colour Coded
strength Member Frp Rod / Steel Wire Embedded in Sheath
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
water Blocking Thixotropic Gel (tubes) / Water Swellable Tape
sheath Polyethylene
* Option Available for Unarmoured Cables with Pa-12 Jacket and Corrugated Steel Tape Armoured Cables.\
specifications : Iec 60794 for Mechanical & Environmental Testing.
Copper: Annealed Electrolytic Copper Conductor with Various Diameter Ranging from 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Foam Skin / Cellular / Solid Hdpe Insulation as per Astm D 1248 and Bs 6234.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length. Cable is Assembled By Stranding of 10 Pairs or 20 Pairs or 25 Pairs Basic Subunit.
filling Compound: a Moisture Resistant Filling Compound is Applied to Completely Coat the Insulated Conductors and Fill the Interstices Between Pairs and Units, to Avoid the Seepage of Water from Inside the Cables.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.
sheath: Black Polyethylene Sheath is Extruded Over the Screen.
specifications: Iec 60794 for Mechanical & Environmental Testing.
Copper: Annealed Electrolytic Copper Conductor with Various Diameter Ranging from 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Foam Skin / Cellular / Solid Hdpe Insulation as per Astm D 1248 and Bs 6234.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length. Cable is Assembled By Stranding of 10 Pairs or 20 Pairs or 25 Pairs Basic Subunit.
filling Compound: a Moisture Resistant Filling Compound is Applied to Completely Coat the Insulated Conductors and Fill the Interstices Between Pairs and Units, to Avoid the Seepage of Water from Inside the Cables.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.
sheath: Black Polyethylene Sheath is Extruded Over the Screen.
specifications: Iec 60794 for Mechanical & Environmental Testing.
Type of the Cable : Duct, Direct Burial, Aerial
number of Fibre
2 - 144 Fibre Count
fibre Type
itu-t G 652, G 652 C, G 652 D, G 653, G 654, G 655
loose Tube Material
pbtp, Nylon
water Resistance Thixotropic Jelly
strength Members
frp, Aramid Yarn, Glass Fibre Reinforcements, Steel Wire
moisture Barrier
water Swellable Tape, Flooding Jelly
armouring Material
copolymer Coated S. S. Tape, Copolymer Coated Eccs Tape
sheath / Jacket Compound
hdpe (anti-termite or Normal), Polyamide-12
temperature of Operation ( ° C) – 40 to + 70.
Type of the Cable : Duct, Direct Burial, Aerial
number of Fibre
2 - 144 Fibre Count
fibre Type
itu-t G 652, G 652 C, G 652 D, G 653, G 654, G 655
loose Tube Material
pbtp, Nylon
water Resistance Thixotropic Jelly
strength Members
frp, Aramid Yarn, Glass Fibre Reinforcements, Steel Wire
moisture Barrier
water Swellable Tape, Flooding Jelly
armouring Material
copolymer Coated S. S. Tape, Copolymer Coated Eccs Tape
sheath / Jacket Compound
hdpe (anti-termite or Normal), Polyamide-12
temperature of Operation ( ° C) – 40 to + 70.
Copper: Annealed Electrolytic Plain / Tinned Copper Conductor with Various Diameter of 0.4mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Solid Hdpe / Pvc Insulation.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length .cable is Assembled By Stranding of 10 Pairs / 20pairs or 25 Pairs Basic Subunit.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
sheath: Pvc / Frls Pvc / Pe Sheath in Grey / White / Green / Black Colour is Extruded Over the Cable Core.
Copper: Annealed Electrolytic Plain / Tinned Copper Conductor with Various Diameter of 0.4mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Solid Hdpe / Pvc Insulation.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length .cable is Assembled By Stranding of 10 Pairs / 20pairs or 25 Pairs Basic Subunit.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
sheath: Pvc / Frls Pvc / Pe Sheath in Grey / White / Green / Black Colour is Extruded Over the Cable Core.
Copper: Annealed electrolytic copper conductor with diameter of 0.4mm & 0.5 mm as per IEC28 and ASTM B3.
Insulation: Conductor insulation is Solid HDPE insulation.
Cable Core: Two insulated conductors are twisted together to form a pair with uniform specific lay length .Cable is assembled by stranding of 5 Pairs, 10 pairs & 20pairs basic subunit.
Core wrapping: A non hygroscopic and dielectric polyester film is applied helically over the cable core.
Sheath: PVC / FRLS PVC / PE Sheath is extruded over the cable core.
Option of Water Blocking tape in place of Polyester & Yarns is also available.
Option of Aerial Fig-8, CAT - 3 cable upto 100 Pairs for Aerial applications is also available.
Copper: Annealed electrolytic copper conductor with diameter of 0.4mm & 0.5 mm as per IEC28 and ASTM B3.
Insulation: Conductor insulation is Solid HDPE insulation.
Cable Core: Two insulated conductors are twisted together to form a pair with uniform specific lay length .Cable is assembled by stranding of 5 Pairs, 10 pairs & 20pairs basic subunit.
Core wrapping: A non hygroscopic and dielectric polyester film is applied helically over the cable core.
Sheath: PVC / FRLS PVC / PE Sheath is extruded over the cable core.
Option of Water Blocking tape in place of Polyester & Yarns is also available.
Option of Aerial Fig-8, CAT - 3 cable upto 100 Pairs for Aerial applications is also available.
Construction Details: Multiloose Tube Cables ( 2f - 96f)
number of Elements (2f to 72f)6 Nos
( 96f )8 Nos
tube/fibre Identification : Colour Coded
central Strength Member : Fibre Reinforced Plastic (frp)
fibre Protection (tubes)polybutylene Terephthalate (pbt)
fillers as Required
water Blocking Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
peripheral Strength Members : Aramid Yarns
sheath
pvc / Pe / Lszh
* Option Available for Jelly Filled Cables
construction Details: Unitube Cables (2f -24f)
number of Fibres per Tube 24 Nos.
fibre Identification : Colour Coded
strength Member frp / Arp Rod / Steel Wire Embedded in Sheath
fibre Protection (tubes)polybutylene Terephthalate (pbt)
fillers as Required
water Blocking
thixotropic Gel (tubes) / Tape
sheath pvc / Polyethylene / Lszh
* Option Available for Jelly Filled Cables / Flat Cables
specifications : Iec 60794 for Mechanical & Environmental Testing.
Construction Details: Multiloose Tube Cables ( 2f - 96f)
number of Elements (2f to 72f)6 Nos
( 96f )8 Nos
tube/fibre Identification : Colour Coded
central Strength Member : Fibre Reinforced Plastic (frp)
fibre Protection (tubes)polybutylene Terephthalate (pbt)
fillers as Required
water Blocking Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
peripheral Strength Members : Aramid Yarns
sheath
pvc / Pe / Lszh
* Option Available for Jelly Filled Cables
construction Details: Unitube Cables (2f -24f)
number of Fibres per Tube 24 Nos.
fibre Identification : Colour Coded
strength Member frp / Arp Rod / Steel Wire Embedded in Sheath
fibre Protection (tubes)polybutylene Terephthalate (pbt)
fillers as Required
water Blocking
thixotropic Gel (tubes) / Tape
sheath pvc / Polyethylene / Lszh
* Option Available for Jelly Filled Cables / Flat Cables
specifications : Iec 60794 for Mechanical & Environmental Testing.
We are Offering Aerial Optical Fibre Cables.
construction Details: Multiloose Tube Cables (2f - 96f)
number of Elements (2f to 72f) 6 Nos
( 96f ) 8 Nos
tube/fibre Identification Colour Coded
central Strength Member Fibre Reinforced Plastic (frp)
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
fillers
as Required
water Blocking Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
sheath Polyethylene
peripheral Strength Member
aramid Yarns
* Option Available for Unitube Adss Cables
construction Details: Multiloose Tube Cables ( 2f - 96f)
number of Elements (2f to 72f) 6 Nos
( 96f ) 8 Nos
tube/fibre Identification Colour Coded
central Strength Member Fibre Reinforced Plastic (frp)
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
fillers as Required
water Blocking
thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
sheath Polyethylene
suspension Strand
7 Wire Galvanized Steel Strand
* Option Available for Unitube Fig-8 Aerial Cables
specifications : Iec 60794 for Mechanical & Environmental Testing.
We are Offering Aerial Optical Fibre Cables.
construction Details: Multiloose Tube Cables (2f - 96f)
number of Elements (2f to 72f) 6 Nos
( 96f ) 8 Nos
tube/fibre Identification Colour Coded
central Strength Member Fibre Reinforced Plastic (frp)
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
fillers
as Required
water Blocking Thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
sheath Polyethylene
peripheral Strength Member
aramid Yarns
* Option Available for Unitube Adss Cables
construction Details: Multiloose Tube Cables ( 2f - 96f)
number of Elements (2f to 72f) 6 Nos
( 96f ) 8 Nos
tube/fibre Identification Colour Coded
central Strength Member Fibre Reinforced Plastic (frp)
fibre Protection (tubes) Polybutylene Terephthalate (pbt)
fillers as Required
water Blocking
thixotropic Gel (tubes) / Jelly (interstices)
core Wrapping Polyester Tape
sheath Polyethylene
suspension Strand
7 Wire Galvanized Steel Strand
* Option Available for Unitube Fig-8 Aerial Cables
specifications : Iec 60794 for Mechanical & Environmental Testing.
Copper: Annealed Electrolytic Copper Conductor with Various Diameter of 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Solid Hdpe / Foam Skin / Cellular Insulation as per Astm D 1248 and Bs 6234.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length . Cable is Assembled By Stranding of 10 Pairs / 20 Pairs or 25 Pairs Basic Subunit.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.
suspension Strand: 7 Wire Suspension Strand is Made Integral Part of the Cable and a Common Sheath is Provided Over Cable Core and Suspension Strand.
sheath: Black Polyethylene Sheath is Extruded Over the Screen.
jelly Filled Cable Option also Available.
Copper: Annealed Electrolytic Copper Conductor with Various Diameter of 0.4 Mm to 0.9 Mm as per Iec28 and Astm B3.
insulation: Conductor Insulation are Solid Hdpe / Foam Skin / Cellular Insulation as per Astm D 1248 and Bs 6234.
cable Core: Two Insulated Conductors are Twisted Together to Form a Pair with Uniform Specific Lay Length . Cable is Assembled By Stranding of 10 Pairs / 20 Pairs or 25 Pairs Basic Subunit.
core Wrapping: a Non Hygroscopic and Dielectric Polyester Film is Applied Helically Over the Cable Core.
moisture Barrier/screen: An Aluminum Foil Coated with Co-polymer On Both Sides or One Side is Applied Longitudinally Over the Cable Core.
suspension Strand: 7 Wire Suspension Strand is Made Integral Part of the Cable and a Common Sheath is Provided Over Cable Core and Suspension Strand.
sheath: Black Polyethylene Sheath is Extruded Over the Screen.
jelly Filled Cable Option also Available.