Power Factor Controller Dealers in Sangli

(4 products available)
  • SYCON-66 XX - Automatic Power Factor Controller

    SYCON-66 XX - Automatic Power Factor Controller

    Get Price Quote

    This version of 66 XX series displays all parameters such as power factor, shortfall KVAR Excess KVAR , voltage, current and THD all at a time. By selection, it displays % harmonic from 3rd to 13th and capacitor values. It has built in facility to cut-off the capacitors in case of harmonic overload. It has password protected settings. It’s built-in TEST mode enables to test the panel without CT current. Auto as well as Manual mode of operation are available in this relay.
    ...more
  • Automatic Power Factor Controller

    Automatic Power Factor Controller

    18,150 / Units

    • PhaseSingle
    • Frequency50 Hz
    • BrandSycon
    • Model Name/NumberSYCON 6616
    • Display TypeLCD Display (2x16 character)
    • Input Voltage415 AC-15%
    • Current Input5 A, 1 A (optional)
    • Over Voltage Release470 V AC -1%
    • Low current1% (50mA)
    • Switching Contact10A at 250V AC
    • AccuracyClass1
    • Switching Interval5-1200Sec
    • Dimensions144 (L) x 144 (W) x 80(D) mm
    • Panel Cutout138 mm x 138 mm
    • Weight1.6Kg
    ...more
  • Automatic Power Factor Controller

    Automatic Power Factor Controller

    Get Price Quote

    • MOQ1 Piece
    • Brand NameSYCON
    • we are offering automatic power factor controller general features fifo switching friendly user interface easy to install large 2-digit 7-segment display available in 4,6 & 8 stages low cost display features power factor led indication of leadlag led indication of capacitor onoff status settings control features site settable two point target pf capacitor disconnection in case of low current test mode facility electrical specifications voltage input 415v ac -15% current input --5a frequency 50hz over voltage release 470v ac -1% low current 1.8% (90ma) switching contact 10a at 250v ac accuracy 1 digit switching time 5 sec dimensions 96(l) x 96(w) x 110(d) mm panel cutout 92 x 92 mm.
    ...more
  • Power Factor Controller

    Power Factor Controller

    Get Price Quote

    Features RISC Microcontroller based field proven design Three digit PF display Individual Stage LED indications Indication range from 0.5 lag to 0.5 lead User settable High and Low set points also in three digit User settable bank on time, bank off time, bank discharge time Settable Cyclic or FIFO switching sequence Settable No Load Compensation (NLC) For Transformer Auto or Manual Mode Selectable from outside switch For all settings the controller is protected by a password to avoid unauthorized access. Test mode for testing the wiring logic when there is no load current. Input voltage from phases R & Y Input Current from phase B CT All Electrical Connections on rear side Potential free relay contact outputs to operate the banks Relay contact rating is 5 amps at 230 VAC
    ...more
Filter by Locality