Zar water softner with FRP pressure vessels one charge of cation exchange resin, manual multiport top mounted valve & plastic regeneration tank. Light weight, easyto install. Do not require concrete foundation. Top mounted valve for smooth operation. Does not require electricity nor operator. Pre assembled & can be installed within hours. No wear and tear parts. Easy availability of spares. Consumption of shampoo, detergent, scouring powder/liquid & toilet soap. Prevent hair loss, make hair shine & skin soft. No deposit of salt on utensils & tap. Fixtures don't clog.
Zar water softner with FRP pressure vessels one charge of cation exchange resin, manual multiport top mounted valve & plastic regeneration tank. Light weight, easyto install. Do not require concrete foundation. Top mounted valve for smooth operation. Does not require electricity nor operator. Pre assembled & can be installed within hours. No wear and tear parts. Easy availability of spares. Consumption of shampoo, detergent, scouring powder/liquid & toilet soap. Prevent hair loss, make hair shine & skin soft. No deposit of salt on utensils & tap. Fixtures don't clog.
Capacity: 70,000 KCals/hr. to 15,00.000 KCals/hr. Suitable Furnace For Every Fuel Horizontal grate For Coal, Lignite, Wood Chips etc. & Inclined Grate (Step Grate ) For loose Bagasse, Wood, Waste, Husk etc. Balanced Draft System : Ensure minimum infiltration of unwanted air. so efficient combustion & Higher Efficiency. Vertical / Horizontal Design : Easy to operate & maintain, Low building & infrastructure cost. Thermic Fluid Preheater : Absorbs the waste heat of the flue gasses & Increase the efficiency.
Capacity: 70,000 KCals/hr. to 15,00.000 KCals/hr. Suitable Furnace For Every Fuel Horizontal grate For Coal, Lignite, Wood Chips etc. & Inclined Grate (Step Grate ) For loose Bagasse, Wood, Waste, Husk etc. Balanced Draft System : Ensure minimum infiltration of unwanted air. so efficient combustion & Higher Efficiency. Vertical / Horizontal Design : Easy to operate & maintain, Low building & infrastructure cost. Thermic Fluid Preheater : Absorbs the waste heat of the flue gasses & Increase the efficiency.
Solid Fuel Fired (SIB) Steam Boilers
Capacity: 300 kgs/hr pressure 7 kgs/sqcm. Type: horizontal, shell type smoke tube boiler. Fully automatic, three pass wet back design. High efficiency 75±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Solid Fuel Fired (SIB) Steam Boilers
Capacity: 300 kgs/hr pressure 7 kgs/sqcm. Type: horizontal, shell type smoke tube boiler. Fully automatic, three pass wet back design. High efficiency 75±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Capacity: 300 kgs/hr and above. Type: horizontal, shell type smoke tube boiler. Fully automatic, three pass wet back design. High efficiency 75±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Capacity: 300 kgs/hr and above. Type: horizontal, shell type smoke tube boiler. Fully automatic, three pass wet back design. High efficiency 75±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Single pass design. Manual Firing. Very low operating cost. Easy to install and easy to operate. Design for maximum efficiency of 65%. Shell type combustion chamber and shell & tube type Heat Exchanger economizer. Capacity. 30.000 kcal/hr to 10 lac kcals/hr.
Single pass design. Manual Firing. Very low operating cost. Easy to install and easy to operate. Design for maximum efficiency of 65%. Shell type combustion chamber and shell & tube type Heat Exchanger economizer. Capacity. 30.000 kcal/hr to 10 lac kcals/hr.
Manually operated, vertical/horizontal design. Shell type three pass design. Design for easy operation & maintenance. Relaible high coverage efficiency of 70%±5 [NCV]. Can be designed to meet customer specific requiremts. All standards indigenous parts ensures easy availability of spares.
Manually operated, vertical/horizontal design. Shell type three pass design. Design for easy operation & maintenance. Relaible high coverage efficiency of 70%±5 [NCV]. Can be designed to meet customer specific requiremts. All standards indigenous parts ensures easy availability of spares.
Capacity: 50 kgs/hr to 850 kgs/hr. Fully automatic, NON-IBR vertical design. Designed for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Large tube diameter of coil [31.75] mm OD means less frequent descaling. Can be designed to meet customer specific requiremts. Available in two types: a) Diesel operated b) Gas operated
Capacity: 50 kgs/hr to 850 kgs/hr. Fully automatic, NON-IBR vertical design. Designed for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Large tube diameter of coil [31.75] mm OD means less frequent descaling. Can be designed to meet customer specific requiremts. Available in two types: a) Diesel operated b) Gas operated
Cap. 30,000 KCals/hr to 10,00,000 KCals/hr. Low investments, low running expenses. Easy to operate. Occupies small floor space. Two pass design hence easy for cleaning & maintenance. Shell type combustion chamber and shell & tube type economizer. This type of design increases efficiency and tolerates a high degree of hardness in water. Available in two types: a) Shell type standard b) Coil type All standard indigenous parts ensures easy availability of spares.
Cap. 30,000 KCals/hr to 10,00,000 KCals/hr. Low investments, low running expenses. Easy to operate. Occupies small floor space. Two pass design hence easy for cleaning & maintenance. Shell type combustion chamber and shell & tube type economizer. This type of design increases efficiency and tolerates a high degree of hardness in water. Available in two types: a) Shell type standard b) Coil type All standard indigenous parts ensures easy availability of spares.
Capacity: 70,000 KCals/hr. to 10,00,000 KCals/hr. Fully automatic, three pass design. Design for max, efficiency 89 ± 2%. The Thermic fluid circuits permits the transfer of energy at high temperature without the risk of corrosion or pressure. Designed for heating thermic fluid up to 300 C almost at atmospheric pressure. All heat transfer parts made of heavy duty Boiler quality steel tubes, giving long life and safe working. All standard indigenous part ensures easy availability of spares.
Capacity: 70,000 KCals/hr. to 10,00,000 KCals/hr. Fully automatic, three pass design. Design for max, efficiency 89 ± 2%. The Thermic fluid circuits permits the transfer of energy at high temperature without the risk of corrosion or pressure. Designed for heating thermic fluid up to 300 C almost at atmospheric pressure. All heat transfer parts made of heavy duty Boiler quality steel tubes, giving long life and safe working. All standard indigenous part ensures easy availability of spares.
Cap. 30,000 Kcal/hr to 10,00,000 Kcal/hr. Fully automatic Non IBR Reverse flue design. Design for easy operation & maintenance. Reliable nigh coverage efficiency of 88%. (NCV) The large tube diameter of coil (31.75 mm OD) means less frequent descaling. This convert into longer coil life and minimum production down time. Units can be designed to meet customers specific requirements. All standards indigenous parts ensures easy availability of spares.
Cap. 30,000 Kcal/hr to 10,00,000 Kcal/hr. Fully automatic Non IBR Reverse flue design. Design for easy operation & maintenance. Reliable nigh coverage efficiency of 88%. (NCV) The large tube diameter of coil (31.75 mm OD) means less frequent descaling. This convert into longer coil life and minimum production down time. Units can be designed to meet customers specific requirements. All standards indigenous parts ensures easy availability of spares.
Fully automatic for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Fitted with all safety and indigenies accessories.Can be designed to meet customer specific requiremts.
Fully automatic for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Fitted with all safety and indigenies accessories.Can be designed to meet customer specific requiremts.
Capacity: 30,000 Kcal/hr and above. Fully automatic for easy operation & maintenance. Shell type combustion chamber & shell-tube type economiser. Reliable high coverage efficiency of 88%±5 [NCV]. All standards indigenous parts ensures easy availability of spares.
Capacity: 30,000 Kcal/hr and above. Fully automatic for easy operation & maintenance. Shell type combustion chamber & shell-tube type economiser. Reliable high coverage efficiency of 88%±5 [NCV]. All standards indigenous parts ensures easy availability of spares.
Electrically Operated Shell Type Steam Generator
Capacity: 10 KGS/HR. to 50 KGS/HR and Above. Compact design. Fully automatic For Easy Operation & Maintenance Reliable High Coverage efficiency with 88±2 [NCV]. Fitted With All Safety And Indigenies Accessories. The Unit Can Be Designed To Meet The Customers Specific Requirements.
Electrically Operated Shell Type Steam Generator
Capacity: 10 KGS/HR. to 50 KGS/HR and Above. Compact design. Fully automatic For Easy Operation & Maintenance Reliable High Coverage efficiency with 88±2 [NCV]. Fitted With All Safety And Indigenies Accessories. The Unit Can Be Designed To Meet The Customers Specific Requirements.
Design for max efficiency 90%. Very Compact, easy to install operate. Can be install very close to user equipment. No Vibration. No Pollution. High reliability and assured safety.
Design for max efficiency 90%. Very Compact, easy to install operate. Can be install very close to user equipment. No Vibration. No Pollution. High reliability and assured safety.
Shell type design. Design for max efficiency 90%. Very Compact, easy to install operate. Can be install very close to user equipment. No Vibration. No Pollution. High reliability and assured safety.
Shell type design. Design for max efficiency 90%. Very Compact, easy to install operate. Can be install very close to user equipment. No Vibration. No Pollution. High reliability and assured safety.
Capacity: 300 KGS/HR and above. Compact design. Fully automatic for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Capacity: 300 KGS/HR and above. Compact design. Fully automatic for easy operation & maintenance. Relaible high coverage efficiency of 88±2 [NCV]. Fitted with all safety and indigenies accessories. Can be designed to meet customer specific requiremts.
Automatic controlled horizontal design. Shell type three pass design. Design for easy operation & maintenance. Relaible high coverage efficiency of 70%±5 [NCV]. Can be designed to meet customer specific requiremts. All standards indigenous parts ensures easy availability of spares.
Automatic controlled horizontal design. Shell type three pass design. Design for easy operation & maintenance. Relaible high coverage efficiency of 70%±5 [NCV]. Can be designed to meet customer specific requiremts. All standards indigenous parts ensures easy availability of spares.
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
RAZ BOILERS established in 1994.are one of the reputed manufacturer in design engineering, site installation and commissioning wide range of Non IBR & IBR Steam Boilers, Hot Water Generators., Thermic Fluid Heaters, Burners and Air Heaters. RAZ BOILERS is the most respected brand name in specialized engineering services in the field of Boilers. Since all these hard working years have been able to supply more than 1000 units to our prestigeous client. Since our founding in 1994, We are continuously looked for the best ways to serve our customers. This website is in keeping with that goal. Please visit to see the products ad services that have made us one of the most respected and enduring leaders in process heat equipments industry. We also caters the following products : Water Softeners D. M. Plants / Reverese Osmosis Plant Effluent Treatment Plants Wet Scrubbers Jacketed Vessels