Haico India Lokmanya Nagar, Thane, Maharashtra

GST Number : 27AQVPK9829L1ZP
Contact Supplier Request A Quote
  • water quality analysis spectro-photometers

    water quality analysis spectro-photometers

    250,000 - 450,000 / Nos

    Wavelength Range 390 to 950nm Mobility Portable Model No / Item Code Primalab Photometric Range More than 145 Parameters Data Output Port Connectivity (technical): Bluetooth 4.2 WiFi USB (type C) 4G* (via USB-modem) Display TFT Flat 5.5" Color-HD touch display Usage / Application Water Testing Sample Compartment Different Types available Dimensions 100x255x59 mm Measuring Time Less than 3 Secs. Data Storage >5000 (internal) Language English Printer Port Available through Bluetooth Warranty 12 months Power Battry Powered 8500 mA Li-lon-battery Weight 715 g Operating Temperature 5...45 DegreeC, 30 - 90% relative humidity   The next generation of photometers – the PrimeLab 2.0, Delivers high-precision readings due to 18 parallel wavelengths, WiFi–USB–Bluetooth®–GSM** connection, powerful software and app, synchronised via a free cloud service, large HD touch display and the possibility to connect electrodes are just some of the features. While conventional photometers only perform tests at selected wavelengths, the Primelab can also receive data from 18 different wavelengths in parallel and thus covers the most important parts of the UV and IR range as well as the entire VIS range. Corresponding LEDs are positioned at both 180° and 90° to also allow NTU turbidity, PTSA and fluorescein measurements. Very narrow peaks between 390 and 950 nm enable the most accurate readings, close to the performance of a spectrophotometer.   The PrimeLab 2.0 is the ultimate in connectivity! With WiFi–USB–GSM**(via USB modem) there are several ways to connect the PrimeLab 2.0 to a smartphone, tablet, computer or directly to the LabCOM® cloud. Wherever the tests are carried out, whether it is in the lab, on site or on a ship, inside a cooling tower – in fact anywhere – the data can be transferred easily and automatically. Tests include: • Alkalinity• Aluminum• Ammonia• Ammonia, Free• Anammox Activity• Arsenic• Barium• Benzotriazole / Tolyltriazole• Boron• Bromine• Cadmium• Cationic Surfactants• Chloride• Chlorine Dioxide• Chlorine, Free• Chlorine, Total• Chromium, Hexavalent• Chromium, Hexavalent & Total• Chromium, Total• Cobalt• COD (Chemical Oxygen Demand)• Color• Copper• Cyanide• Detergents / Surfactants• Dissolved Oxygen• Fluoride• Formaldehyde• Hardness• Hydrazine• Hydrogen Peroxide• Iodine• Iron• Lead• Magnesium, Total• Manganese• Mercury• Molybdenum• Monochloramine• Nickel• Nitrate• Nitrite• Nitrogen, Ammonia• Nitrogen, Total• Nitrogen, Total Inorganic (TIN)• Nonionic surfactants• Oxygen Scavengers• Organic Constituents (UV-254)• Ozone• Peracetic Acid (PAA)• Phenols• Phosphonates• Phosphorus• Potassium• Quaternary Ammonium Compounds• Selenium• Silica• Silver• Sulfate• Sulfide / Hydrogen Sulfide• Sulfite• Suspended Solids• Tannin and Lignin• TKN• Total Organic Carbon (TOC)• Toxicity• TPH in soil• Trihalomethanes, Total (THM)• Volatile Acids• Zinc
    ...more
  • water quality analysis spectro-photometers

    water quality analysis spectro-photometers

    250,000 - 450,000 / Nos

    Wavelength Range 390 to 950nm Mobility Portable Model No / Item Code Primalab Photometric Range More than 145 Parameters Data Output Port Connectivity (technical): Bluetooth 4.2 WiFi USB (type C) 4G* (via USB-modem) Display TFT Flat 5.5" Color-HD touch display Usage / Application Water Testing Sample Compartment Different Types available Dimensions 100x255x59 mm Measuring Time Less than 3 Secs. Data Storage >5000 (internal) Language English Printer Port Available through Bluetooth Warranty 12 months Power Battry Powered 8500 mA Li-lon-battery Weight 715 g Operating Temperature 5...45 DegreeC, 30 - 90% relative humidity   The next generation of photometers – the PrimeLab 2.0, Delivers high-precision readings due to 18 parallel wavelengths, WiFi–USB–Bluetooth®–GSM** connection, powerful software and app, synchronised via a free cloud service, large HD touch display and the possibility to connect electrodes are just some of the features. While conventional photometers only perform tests at selected wavelengths, the Primelab can also receive data from 18 different wavelengths in parallel and thus covers the most important parts of the UV and IR range as well as the entire VIS range. Corresponding LEDs are positioned at both 180° and 90° to also allow NTU turbidity, PTSA and fluorescein measurements. Very narrow peaks between 390 and 950 nm enable the most accurate readings, close to the performance of a spectrophotometer.   The PrimeLab 2.0 is the ultimate in connectivity! With WiFi–USB–GSM**(via USB modem) there are several ways to connect the PrimeLab 2.0 to a smartphone, tablet, computer or directly to the LabCOM® cloud. Wherever the tests are carried out, whether it is in the lab, on site or on a ship, inside a cooling tower – in fact anywhere – the data can be transferred easily and automatically. Tests include: • Alkalinity• Aluminum• Ammonia• Ammonia, Free• Anammox Activity• Arsenic• Barium• Benzotriazole / Tolyltriazole• Boron• Bromine• Cadmium• Cationic Surfactants• Chloride• Chlorine Dioxide• Chlorine, Free• Chlorine, Total• Chromium, Hexavalent• Chromium, Hexavalent & Total• Chromium, Total• Cobalt• COD (Chemical Oxygen Demand)• Color• Copper• Cyanide• Detergents / Surfactants• Dissolved Oxygen• Fluoride• Formaldehyde• Hardness• Hydrazine• Hydrogen Peroxide• Iodine• Iron• Lead• Magnesium, Total• Manganese• Mercury• Molybdenum• Monochloramine• Nickel• Nitrate• Nitrite• Nitrogen, Ammonia• Nitrogen, Total• Nitrogen, Total Inorganic (TIN)• Nonionic surfactants• Oxygen Scavengers• Organic Constituents (UV-254)• Ozone• Peracetic Acid (PAA)• Phenols• Phosphonates• Phosphorus• Potassium• Quaternary Ammonium Compounds• Selenium• Silica• Silver• Sulfate• Sulfide / Hydrogen Sulfide• Sulfite• Suspended Solids• Tannin and Lignin• TKN• Total Organic Carbon (TOC)• Toxicity• TPH in soil• Trihalomethanes, Total (THM)• Volatile Acids• Zinc

    ...more
    Get Best Price
  • Water Bath Heater

    Water Bath Heater

    15,000 - 80,000 / Nos

    • Brand NameHaico
    • Housing MaterialSS 304
    • ConditionNew
    • Automatic GradeAutomatic, Fully Automatic, Semi Automatic
    • Power1-3kw
    • Power SourceSingle Phase
    • Power Supply220 V A.C. 50Hz
    • ApplicationLaboratory
    • Country of Origin220V
    • Temperature Capacity50-100C
    • Number Of FlowerWater Bath Heater
    • Availability10-0kg
    • Heating ElementHigh Grade Kanthal Cartridge
    • InstallationTable Top
    • Total Carbohydrate1year
    • After-Sales Service ProvidedYes
    • Country of OriginIndia
    • Energy sourceElectric
    • A water bath is a laboratory tool that can incubate samples at a constant temperature for long periods of time. It's a preferred heat source for heating flammable chemicals instead of an open flame.   HAICO Digital Thermostatic Water Bath is a laboratory water bath that can reach temperatures ranging from room temperature to 100°C. It has a built-in timer that can be set from 0–999 minutes and a temperature resolution of 0.1°C.    Here are some other features of the HAICO Digital Thermostatic Water Bath:  · Concave surface to prevent liquid · Stainless steel material · Adjustable hole size · Bi-integral A/D converter · Plug-out pipe outfall · Concave control panel · Double digital display
    ...more
  • Water Bath Heater

    Water Bath Heater

    15,000 - 80,000 / Nos

    1 Nos (MOQ)

    A water bath is a laboratory tool that can incubate samples at a constant temperature for long periods of time. It's a preferred heat source for heating flammable chemicals instead of an open flame.   HAICO Digital Thermostatic Water Bath is a laboratory water bath that can reach temperatures ranging from room temperature to 100°C. It has a built-in timer that can be set from 0–999 minutes and a temperature resolution of 0.1°C.    Here are some other features of the HAICO Digital Thermostatic Water Bath:  · Concave surface to prevent liquid · Stainless steel material · Adjustable hole size · Bi-integral A/D converter · Plug-out pipe outfall · Concave control panel · Double digital display

    Brand Name : Haico

    Housing Material : SS 304

    Condition : New

    Automatic Grade : Automatic, Fully Automatic, Semi Automatic

    Power : 1-3kw

    Power Source : Single Phase

    Power Supply : 220 V A.C. 50Hz

    Application : Laboratory

    Country of Origin : 220V

    Temperature Capacity : 50-100C

    Number Of Flower : Water Bath Heater

    Availability : 10-0kg

    Heating Element : High Grade Kanthal Cartridge

    Installation : Table Top

    Total Carbohydrate : 1year

    After-Sales Service Provided : Yes

    Country of Origin : India

    Energy source : Electric

    ...more
    Get Best Price
  • Vacuum Pump for LCMS

    Vacuum Pump for LCMS

    350,000 - 550,000 / Nos

    • ApplicationLaboratory
    • Driven TypeElectric
    • MaterialAluminium
    • FinishingPolished
    • Brand NameHaico
    • Power1-3kw
    • Flow Rate 40 m3 Type Oil Lubricant Vacuum Pumps Number Of Stages Single stage Power 2 HP Usage/Application Industrial Phase Three Mounting Floor / Permanent Motor Speed 1440 Voltage 380 V A.C. Weight 62Kg Cooling System Air cooled Noise Level Less than 70dB Motor Power 1.5Kw Oil Tank Capacity 1 Lit Automation Grade Semi-Automatic Frequency 50Hz Max Vacuum 0.3 mbar   Vacuum pumps play a crucial role in liquid chromatography-mass spectrometry (LC-MS) systems. Their importance lies in maintaining the high vacuum conditions required for the mass spectrometer to operate effectively.  Here are the key reasons why vacuum pumps are essential for LC-MS:  Minimizing ion collisions: Mass spectrometers operate at very low pressures (high vacuum), typically 10^-2 to 10^-5 Pa (10^-4 to 10^-7 torr), to reduce the chances of ions colliding with other molecules in the mass analyzer. 4 Any collisions can cause ions to react, neutralize, scatter, or fragment, interfering with the mass spectrum. 4  Enabling ionization: Certain ionization techniques used in LC-MS, such as electrospray ionization (ESI), require a vacuum interface to transfer ions from atmospheric pressure to the high vacuum region of the mass spectrometer. 3 The vacuum pumps maintain the necessary pressure gradient for efficient ion transfer.  Maintaining analyzer performance: The mass analyzer, where ions are separated based on their mass-to-charge ratio, requires high vacuum conditions to operate accurately. 4 Vacuum pumps ensure the analyzer remains free from contaminants and maintains its resolving power.  Enabling detection: The ion detector, which measures the separated ion beams, also requires high vacuum conditions to function properly. 4 Vacuum pumps prevent interference from neutral molecules and maintain the detector's sensitivity.  In summary, vacuum pumps are indispensable components of LC-MS systems, enabling the creation and maintenance of the high vacuum conditions necessary for accurate and sensitive mass spectrometric analysis of liquid chromatography samples.To ensure the highest levels of accuracy and performance of LCMS systems, a range of full vacuum pump supplies is available.
    ...more
  • Vacuum Pump for LCMS

    Vacuum Pump for LCMS

    350,000 - 550,000 / Nos

    1 Nos (MOQ)

    Flow Rate 40 m3 Type Oil Lubricant Vacuum Pumps Number Of Stages Single stage Power 2 HP Usage/Application Industrial Phase Three Mounting Floor / Permanent Motor Speed 1440 Voltage 380 V A.C. Weight 62Kg Cooling System Air cooled Noise Level Less than 70dB Motor Power 1.5Kw Oil Tank Capacity 1 Lit Automation Grade Semi-Automatic Frequency 50Hz Max Vacuum 0.3 mbar   Vacuum pumps play a crucial role in liquid chromatography-mass spectrometry (LC-MS) systems. Their importance lies in maintaining the high vacuum conditions required for the mass spectrometer to operate effectively.  Here are the key reasons why vacuum pumps are essential for LC-MS:  Minimizing ion collisions: Mass spectrometers operate at very low pressures (high vacuum), typically 10^-2 to 10^-5 Pa (10^-4 to 10^-7 torr), to reduce the chances of ions colliding with other molecules in the mass analyzer. 4 Any collisions can cause ions to react, neutralize, scatter, or fragment, interfering with the mass spectrum. 4  Enabling ionization: Certain ionization techniques used in LC-MS, such as electrospray ionization (ESI), require a vacuum interface to transfer ions from atmospheric pressure to the high vacuum region of the mass spectrometer. 3 The vacuum pumps maintain the necessary pressure gradient for efficient ion transfer.  Maintaining analyzer performance: The mass analyzer, where ions are separated based on their mass-to-charge ratio, requires high vacuum conditions to operate accurately. 4 Vacuum pumps ensure the analyzer remains free from contaminants and maintains its resolving power.  Enabling detection: The ion detector, which measures the separated ion beams, also requires high vacuum conditions to function properly. 4 Vacuum pumps prevent interference from neutral molecules and maintain the detector's sensitivity.  In summary, vacuum pumps are indispensable components of LC-MS systems, enabling the creation and maintenance of the high vacuum conditions necessary for accurate and sensitive mass spectrometric analysis of liquid chromatography samples.To ensure the highest levels of accuracy and performance of LCMS systems, a range of full vacuum pump supplies is available.

    Application : Laboratory

    Driven Type : Electric

    Material : Aluminium

    Finishing : Polished

    Brand Name : Haico

    Power : 1-3kw

    ...more
    Get Best Price
  • Ultra High Vacuum Pump for Electron Microscope

    Ultra High Vacuum Pump for Electron Microscope

    150,000 - 550,000 / Nos

    • Brand NameHaico
    • MaterialAluminium
    • FinishingPolished
    • Driven TypeElectric
    • Power1-3kw
    • Sound Pressure Level < 50dB Free Air Displacement 80 lps Phase Single phase as weell as Three phase both options available Material Aluminium Mounting Floor / Permanent Motor Speed 60000 Voltage 220 V AC or 440 V AC Weight 30 Kg Cooling System Air Cooled Automation Grade Automatic Frequency 50Hz or 60Hz Packaging Type Wooden Box Packing Export Grade Motor Phase Sigle phase or Three Phase Max Vacuum 6 * 10-5 Pa   Molecular vacuum pumps play a crucial role in electron microscopes, as they are responsible for creating and maintaining the high vacuum environment necessary for the proper operation of these instruments. Here are some key reasons why molecular vacuum pumps are important in electron microscopes:   Mean free path: Electron microscopes operate by using a beam of electrons to image samples. In order for the electrons to travel without interference or scattering, they need to have a sufficiently long mean free path, which can only be achieved in a high vacuum environment. Molecular vacuum pumps can create a vacuum level of around 10^-7 to 10^-9 mbar, providing the necessary mean free path for electron beams.   Sample preservation: Many samples used in electron microscopy, particularly biological samples, are sensitive to air exposure and can degrade or become contaminated in the presence of gases and moisture. The high vacuum created by molecular vacuum pumps helps preserve these delicate samples during imaging.   Electron source protection: Electron microscopes typically use a filament or field emission gun as the electron source. These sources can be easily damaged or contaminated by gases present in the air. The high vacuum environment maintained by molecular vacuum pumps protects the electron source and ensures its long-term performance.   Imaging resolution: The resolution of an electron microscope is directly related to the quality of the vacuum. Higher vacuum levels result in better resolution, as the electron beam can travel with fewer interactions and scattering events. Molecular vacuum pumps enable the high vacuum levels required for achieving the highest possible imaging resolution.   Compatibility with other components: Electron microscopes often incorporate various other components, such as detectors, specimen stages, and analytical accessories. These components may require a high vacuum environment to function properly or to avoid contamination. Molecular vacuum pumps provide the necessary vacuum level for the optimal performance of these components.   In summary, molecular vacuum pumps are essential for electron microscopes because they create and maintain the high vacuum environment required for the generation, transmission, and detection of electron beams, as well as for the preservation of samples and the protection of sensitive components. About this product High-Performance Turbomolecular Pump: The Turbo Pumps offer exceptional performance in the automotive industry, metal and equipment manufacturers, mining industry, PVD vacuum coating, CVD vacuum coating, and scientific research applications. Standard and Customized Options: As a standard product, the HTFB-63/80 is available for immediate purchase, while our OEM, ODM, and OBM customized support options cater to specific user needs, such as John (e.g. user John can request a customized design). Reliable Air Cooling System: The pump features an air cooling system, ensuring efficient operation and longevity in high-pressure environments. Wide Voltage Compatibility: The Turbo Vacuum pump is compatible with both 220V and 380V power sources, making it suitable for various applications.   Extended Warranty: We optionally offer a 24-month warranty for the Turbo molecular Vacuum Pump, providing users with peace of mind and protection for their investment.  
    ...more
  • Ultra High Vacuum Pump for Electron Microscope

    Ultra High Vacuum Pump for Electron Microscope

    150,000 - 550,000 / Nos

    Sound Pressure Level < 50dB Free Air Displacement 80 lps Phase Single phase as weell as Three phase both options available Material Aluminium Mounting Floor / Permanent Motor Speed 60000 Voltage 220 V AC or 440 V AC Weight 30 Kg Cooling System Air Cooled Automation Grade Automatic Frequency 50Hz or 60Hz Packaging Type Wooden Box Packing Export Grade Motor Phase Sigle phase or Three Phase Max Vacuum 6 * 10-5 Pa   Molecular vacuum pumps play a crucial role in electron microscopes, as they are responsible for creating and maintaining the high vacuum environment necessary for the proper operation of these instruments. Here are some key reasons why molecular vacuum pumps are important in electron microscopes:   Mean free path: Electron microscopes operate by using a beam of electrons to image samples. In order for the electrons to travel without interference or scattering, they need to have a sufficiently long mean free path, which can only be achieved in a high vacuum environment. Molecular vacuum pumps can create a vacuum level of around 10^-7 to 10^-9 mbar, providing the necessary mean free path for electron beams.   Sample preservation: Many samples used in electron microscopy, particularly biological samples, are sensitive to air exposure and can degrade or become contaminated in the presence of gases and moisture. The high vacuum created by molecular vacuum pumps helps preserve these delicate samples during imaging.   Electron source protection: Electron microscopes typically use a filament or field emission gun as the electron source. These sources can be easily damaged or contaminated by gases present in the air. The high vacuum environment maintained by molecular vacuum pumps protects the electron source and ensures its long-term performance.   Imaging resolution: The resolution of an electron microscope is directly related to the quality of the vacuum. Higher vacuum levels result in better resolution, as the electron beam can travel with fewer interactions and scattering events. Molecular vacuum pumps enable the high vacuum levels required for achieving the highest possible imaging resolution.   Compatibility with other components: Electron microscopes often incorporate various other components, such as detectors, specimen stages, and analytical accessories. These components may require a high vacuum environment to function properly or to avoid contamination. Molecular vacuum pumps provide the necessary vacuum level for the optimal performance of these components.   In summary, molecular vacuum pumps are essential for electron microscopes because they create and maintain the high vacuum environment required for the generation, transmission, and detection of electron beams, as well as for the preservation of samples and the protection of sensitive components. About this product High-Performance Turbomolecular Pump: The Turbo Pumps offer exceptional performance in the automotive industry, metal and equipment manufacturers, mining industry, PVD vacuum coating, CVD vacuum coating, and scientific research applications. Standard and Customized Options: As a standard product, the HTFB-63/80 is available for immediate purchase, while our OEM, ODM, and OBM customized support options cater to specific user needs, such as John (e.g. user John can request a customized design). Reliable Air Cooling System: The pump features an air cooling system, ensuring efficient operation and longevity in high-pressure environments. Wide Voltage Compatibility: The Turbo Vacuum pump is compatible with both 220V and 380V power sources, making it suitable for various applications.   Extended Warranty: We optionally offer a 24-month warranty for the Turbo molecular Vacuum Pump, providing users with peace of mind and protection for their investment.  

    Brand Name : Haico

    Material : Aluminium

    Finishing : Polished

    Driven Type : Electric

    Power : 1-3kw

    ...more
    Get Best Price
  • Temperature Humidity Data Logger

    Temperature Humidity Data Logger

    25,000 - 100,000 / Nos.

    • Brand NameHaico
    • MaterialPlastic
    • Automation GradeAutomatic, Fully Automatic, Semi Automatic
    • ApplicationHumidity Monitoring, Industrial Use
    • CertificationCE Certified
    • FeatureAccuracy, Stable Performance
    • Display TypeDigital
    • Number Of FlowerHumidity Data Logger, Humidity Sensors
    • Availability200-300gm
    • Total Carbohydrate1Year, 1Year
    • Country of OriginIndia
    • HAICO Datalogger can be used to monitor humidity and temperature of greenhouses, warehouses, food transports, aircraft cabins, refrigerated trucks, containers, museums, and HVAC equipment. It measures and stores up to 32700 relative humidity and 32700 temperature readings over 0 to 100%RH and - 40 to +70°C (-40 to +158°F) measurement ranges by your PC with USB interface. The LCD can show current readings in MAX, MIN and sign of alarms indications. Features : 8 universal input ( RTD. Thermocouple, 0-5Vdc, 0-20mA or 4-20 mA input signals. Onboard 32000 reading per channel storage . Parallel Port Individual HI / LO alarm with 2 relay outputs Additional relay outputs with optional Relay card Networkable using Ethernet Port (optional) Free PC Based Data Acquisition software 21 CFR Part 11 (optional) Front end IP65 protection 3.5 inch TFT with Touch Screen Control Onboard USB Port (Memory stick) Benefits : Easy to configure analog input type with front end TFT touchscreen. Logged data is secured as storage media is inside the unit. Helps to connect any type of dot matrix printer. Relay output for control or activating external alarms. Individual Alarm relay (HI / LO) can be provided for all 16 channels. Data accessible via LAN. Not necessary to pay extra cost. Logged data is secured and can not be manipulated by user. Panel mounting enclosure which can sustain in harsh environment. Easy to use icon menu for setting user parameters with touch interface. Logged data can be downloaded to Memory stick and transfer to PC.
    ...more
  • Temperature Humidity Data Logger

    Temperature Humidity Data Logger

    25,000 - 100,000 / Nos.

    1 Nos. (MOQ)

    HAICO Datalogger can be used to monitor humidity and temperature of greenhouses, warehouses, food transports, aircraft cabins, refrigerated trucks, containers, museums, and HVAC equipment. It measures and stores up to 32700 relative humidity and 32700 temperature readings over 0 to 100%RH and - 40 to +70°C (-40 to +158°F) measurement ranges by your PC with USB interface. The LCD can show current readings in MAX, MIN and sign of alarms indications. Features : 8 universal input ( RTD. Thermocouple, 0-5Vdc, 0-20mA or 4-20 mA input signals. Onboard 32000 reading per channel storage . Parallel Port Individual HI / LO alarm with 2 relay outputs Additional relay outputs with optional Relay card Networkable using Ethernet Port (optional) Free PC Based Data Acquisition software 21 CFR Part 11 (optional) Front end IP65 protection 3.5 inch TFT with Touch Screen Control Onboard USB Port (Memory stick) Benefits : Easy to configure analog input type with front end TFT touchscreen. Logged data is secured as storage media is inside the unit. Helps to connect any type of dot matrix printer. Relay output for control or activating external alarms. Individual Alarm relay (HI / LO) can be provided for all 16 channels. Data accessible via LAN. Not necessary to pay extra cost. Logged data is secured and can not be manipulated by user. Panel mounting enclosure which can sustain in harsh environment. Easy to use icon menu for setting user parameters with touch interface. Logged data can be downloaded to Memory stick and transfer to PC.

    Brand Name : Haico

    Material : Plastic

    Automation Grade : Automatic, Fully Automatic, Semi Automatic

    Application : Humidity Monitoring, Industrial Use

    Certification : CE Certified

    Feature : Accuracy, Stable Performance

    Display Type : Digital

    Number Of Flower : Humidity Data Logger, Humidity Sensors

    Availability : 200-300gm

    Total Carbohydrate : 1Year, 1Year

    Country of Origin : India

    ...more
    Get Best Price
  • Table Top Autoclave

    Table Top Autoclave

    50,000 - 100,000 / Nos

    • Brand NameHaico
    • ConditionNew
    • Power220 V A.C. 50Hz
    • ApplicationDental, Medical and Laboratory
    • Capacity18 to 40 lit
    • Total Carbohydrate12 months
    • After-Sales Service ProvidedYes
    • Country of OriginIndia
    • ProcessingMachine
    • HAICO Table Top Autoclave can be used for medical and surgical items in ophthalmology, dentistry and internal medicine clinics, such as packaged items, hollow and porous items for sterilization, and can also be used in emergency rooms and small laboratories.   HAICO Table Top Autoclave is a state-of-the-art sterilization device designed to meet the highest standards in medical-grade sterilization. Its chamber is constructed using S316 medical-grade stainless steel, ensuring durability and corrosion resistance. The autoclave comes equipped with versatile aluminum instrument trays for efficient sterilization of medical instruments. This autoclave adheres to European Class N standards, guaranteeing effective sterilization through its two purge cycle system. The device features a durable and safe band heater, which ensures consistent and reliable heating during the sterilization process. It is also equipped with a calibrated safety valve to maintain optimal pressure levels. The inclusion of a ceramic blanket with a thermal resistivity of 1200°C enhances the insulation and safety of the chamber. Powered by an ARM-based advanced microcontroller system, the autoclave offers precise control over temperature and pressure settings, ensuring accurate and efficient sterilization. The device incorporates a dual safety system for the door, prioritizing user safety at all times. The user-friendly display provides clear and intuitive operation instructions, making it easy to navigate and operate the autoclave effectively.   FEATURES: · Chamber is made of S316 Medical Grade stainless steel · SS wired Instrument Tray · Adopted European Class S, Class N & class B Standards with 2 purge Cycle · Durable and safe band heater · Calibrated Safety Valve · ARM based Advanced Microcontroller System Faster & Better Sterilization · Dual Safety System for Door · Cycle counter · User Friendly Display
    ...more
  • Table Top Autoclave

    Table Top Autoclave

    50,000 - 100,000 / Nos

    1 Nos (MOQ)

    HAICO Table Top Autoclave can be used for medical and surgical items in ophthalmology, dentistry and internal medicine clinics, such as packaged items, hollow and porous items for sterilization, and can also be used in emergency rooms and small laboratories.   HAICO Table Top Autoclave is a state-of-the-art sterilization device designed to meet the highest standards in medical-grade sterilization. Its chamber is constructed using S316 medical-grade stainless steel, ensuring durability and corrosion resistance. The autoclave comes equipped with versatile aluminum instrument trays for efficient sterilization of medical instruments. This autoclave adheres to European Class N standards, guaranteeing effective sterilization through its two purge cycle system. The device features a durable and safe band heater, which ensures consistent and reliable heating during the sterilization process. It is also equipped with a calibrated safety valve to maintain optimal pressure levels. The inclusion of a ceramic blanket with a thermal resistivity of 1200°C enhances the insulation and safety of the chamber. Powered by an ARM-based advanced microcontroller system, the autoclave offers precise control over temperature and pressure settings, ensuring accurate and efficient sterilization. The device incorporates a dual safety system for the door, prioritizing user safety at all times. The user-friendly display provides clear and intuitive operation instructions, making it easy to navigate and operate the autoclave effectively.   FEATURES: · Chamber is made of S316 Medical Grade stainless steel · SS wired Instrument Tray · Adopted European Class S, Class N & class B Standards with 2 purge Cycle · Durable and safe band heater · Calibrated Safety Valve · ARM based Advanced Microcontroller System Faster & Better Sterilization · Dual Safety System for Door · Cycle counter · User Friendly Display

    Brand Name : Haico

    Condition : New

    Power : 220 V A.C. 50Hz

    Application : Dental, Medical and Laboratory

    Capacity : 18 to 40 lit

    Total Carbohydrate : 12 months

    After-Sales Service Provided : Yes

    Country of Origin : India

    Processing : Machine

    ...more
    Get Best Price
  • Stability Chamber

    Stability Chamber

    80,000 - 1,000,000 / Nos

    • Brand NameHaico
    • Driven TypeElectric
    • Packaging TypeAs per Customer's requirement
    • ConditionNew
    • Automatic GradeAutomatic, Fully Automatic, Semi Automatic
    • Power1-3kw, 3-6kw
    • Country of Origin220V
    • Number Of FlowerStability Chamber
    • Total Carbohydrate1year
    • Country of OriginIndia
    • HAICO Stability Chambers are widely used in pharmaceutical laboratory, clinical trials, environmental simulation, material testing and ICH stability studies etc. These test chambers are designed to create extremely stable temperature and humidity environments inside closed cabinet, a mandatory condition to analyze the effects of per-specified conditions on life saving drugs and medicines, biological samples, electronic components and even industrial machine parts etc. Our Stability Chambers are durably constructed for long service life. Standard models come with inner chamber made of stainless steel 304 grade sheet; while exterior is made of thick GI sheet powder coated for rust free performance. We also make GMP models completely made of stainless steel 304 or 316 grades as required. The gap between exterior and interior walls is filled with thick layer of high density PUF insulation. Outer door is made solid in nature and also insulated with PUF material; it is also fitted with locking arrangement to prevent unauthorized access. We use control systems of only reputed brand available in the market. in addition to PID controllers we also use PLC based color HMI control system as option. It features touch screen controller with data logging and memory storage functions. User can also transfer data into pen drive to further save into computer or laptop or even connect the chamber with computer (Ethernet). Several types of safety errors with buzzers can also be configured through HMI.   DETAILED DESCRIPTION   Construction: The overall stability chamber is built on a rigid stainless steel frame, which is nicely jointed with nuts and bolts and arc welding. We use thick gauge of stainless steel 304 or 316 as required. High density PUF insulation is filled between inner and external chambers. Each chamber is provided with suitable number of steel wire mesh cable trays (removable) 4 to 8 or more. Temperature & Humidity: The temperature range of our stability test chambers is 10°C to 60°C; while the humidity range is 35% to 95% RH. As per ICH guidelines our chambers are ideal for storage conditions 25°C at 60% RH, 40°C at 75% RH, 30°C at 65% RH and 25°C at 40% RH. Refrigeration System: For refrigeration, we equip our stability chambers with EMERSON brand CFC free compressors that are hermetically sealed and feature quiet operation. During our 25 years, we found it most dependable and cost effective. Heating: SS tubular air heaters of any reputed brand on the market are fitted to generate warm temperature inside the chamber. Humidity system: For humidity system, we use stainless steel tank and ISI mark immersion heater. It also features automatic water filling and low water safety device. Air circulation: Air circulation is mandatory function to maintain uniform temperature and humidity across the chamber; therefore, we equip our stability test chambers with motorized blower assembly with quiet operation and long life. Control System: Controller is responsible set desired temperature and humidity range. We equip our stability chambers with imported and branded PID controllers, which feature set value (SV) and process value (PV). We also use PLC based HMI controller which is advance system and features color touch screen, various error display, data logging and data transfer to pen drive or direct printout. Illumination: Interior illumination is done by LED light which can be supported by cyclic timer if required. It controls the ON/OFF timing of light for a week. Safety Features: Each stability chamber is equipped with many safety features ensuring you reliable working with with over temperature protection, over current protection and low and high temperature limits and time delay for compressor switch on etc. Data logging: Data logging is important feature, we also provide data logging feature with our stability chambers; PC interface with RS485 communication and also 21 CFR part 11 software.
    ...more
  • Stability Chamber

    Stability Chamber

    80,000 - 1,000,000 / Nos

    1 Nos (MOQ)

    HAICO Stability Chambers are widely used in pharmaceutical laboratory, clinical trials, environmental simulation, material testing and ICH stability studies etc. These test chambers are designed to create extremely stable temperature and humidity environments inside closed cabinet, a mandatory condition to analyze the effects of per-specified conditions on life saving drugs and medicines, biological samples, electronic components and even industrial machine parts etc. Our Stability Chambers are durably constructed for long service life. Standard models come with inner chamber made of stainless steel 304 grade sheet; while exterior is made of thick GI sheet powder coated for rust free performance. We also make GMP models completely made of stainless steel 304 or 316 grades as required. The gap between exterior and interior walls is filled with thick layer of high density PUF insulation. Outer door is made solid in nature and also insulated with PUF material; it is also fitted with locking arrangement to prevent unauthorized access. We use control systems of only reputed brand available in the market. in addition to PID controllers we also use PLC based color HMI control system as option. It features touch screen controller with data logging and memory storage functions. User can also transfer data into pen drive to further save into computer or laptop or even connect the chamber with computer (Ethernet). Several types of safety errors with buzzers can also be configured through HMI.   DETAILED DESCRIPTION   Construction: The overall stability chamber is built on a rigid stainless steel frame, which is nicely jointed with nuts and bolts and arc welding. We use thick gauge of stainless steel 304 or 316 as required. High density PUF insulation is filled between inner and external chambers. Each chamber is provided with suitable number of steel wire mesh cable trays (removable) 4 to 8 or more. Temperature & Humidity: The temperature range of our stability test chambers is 10°C to 60°C; while the humidity range is 35% to 95% RH. As per ICH guidelines our chambers are ideal for storage conditions 25°C at 60% RH, 40°C at 75% RH, 30°C at 65% RH and 25°C at 40% RH. Refrigeration System: For refrigeration, we equip our stability chambers with EMERSON brand CFC free compressors that are hermetically sealed and feature quiet operation. During our 25 years, we found it most dependable and cost effective. Heating: SS tubular air heaters of any reputed brand on the market are fitted to generate warm temperature inside the chamber. Humidity system: For humidity system, we use stainless steel tank and ISI mark immersion heater. It also features automatic water filling and low water safety device. Air circulation: Air circulation is mandatory function to maintain uniform temperature and humidity across the chamber; therefore, we equip our stability test chambers with motorized blower assembly with quiet operation and long life. Control System: Controller is responsible set desired temperature and humidity range. We equip our stability chambers with imported and branded PID controllers, which feature set value (SV) and process value (PV). We also use PLC based HMI controller which is advance system and features color touch screen, various error display, data logging and data transfer to pen drive or direct printout. Illumination: Interior illumination is done by LED light which can be supported by cyclic timer if required. It controls the ON/OFF timing of light for a week. Safety Features: Each stability chamber is equipped with many safety features ensuring you reliable working with with over temperature protection, over current protection and low and high temperature limits and time delay for compressor switch on etc. Data logging: Data logging is important feature, we also provide data logging feature with our stability chambers; PC interface with RS485 communication and also 21 CFR part 11 software.

    Brand Name : Haico

    Driven Type : Electric

    Packaging Type : As per Customer's requirement

    Condition : New

    Automatic Grade : Automatic, Fully Automatic, Semi Automatic

    Power : 1-3kw, 3-6kw

    Country of Origin : 220V

    Number Of Flower : Stability Chamber

    Total Carbohydrate : 1year

    Country of Origin : India

    ...more
    Get Best Price
  • Rotary Barrel Pump

    Rotary Barrel Pump

    150,000 - 450,000 / Piece

    • MaterialStainless Steel, PTFE
    • CertificationISO 9001:2008 Certified
    • Country of OriginIndia
    • Brand NameHaico
    • Surface FinishingPolished
    • FeatureCorrosion Resistance, Durable, High Quality
    • Drum pumps improve the speed and efficiency of transferring liquids. They fit into the opening of drums and barrels, allowing for quick and efficient pumping without the need for manual handling or pouring. Drum pumps provide a safer alternative to manual pouring or siphoning. A wide choice of wetted materials, offer resistance to chemical corrosion in most environments. Material Use PP (polypropylene) Acids, alkalies and detergents up to 50°C PVDF (polyvinylidene fluoride) orCPVC (chlorinated polyvinyl chloride) Chlorine bleach, chromic acid, hydrofluoric acid, nitric acid, sulfuric acid (up to 90°C) Aluminium Oil products such as diesel, heating oil, hydraulic oils, gear oils, engine oils, mineral oils and motor oils up to 1,000 mPas 316 stainless steel Aggressive and flammable media and food, high pressure applications
    ...more
  • Rotary Barrel Pump

    Rotary Barrel Pump

    150,000 - 450,000 / Piece

    1 Piece (MOQ)

    Drum pumps improve the speed and efficiency of transferring liquids. They fit into the opening of drums and barrels, allowing for quick and efficient pumping without the need for manual handling or pouring. Drum pumps provide a safer alternative to manual pouring or siphoning. A wide choice of wetted materials, offer resistance to chemical corrosion in most environments. Material Use PP (polypropylene) Acids, alkalies and detergents up to 50°C PVDF (polyvinylidene fluoride) orCPVC (chlorinated polyvinyl chloride) Chlorine bleach, chromic acid, hydrofluoric acid, nitric acid, sulfuric acid (up to 90°C) Aluminium Oil products such as diesel, heating oil, hydraulic oils, gear oils, engine oils, mineral oils and motor oils up to 1,000 mPas 316 stainless steel Aggressive and flammable media and food, high pressure applications

    Material : Stainless Steel, PTFE

    Certification : ISO 9001:2008 Certified

    Country of Origin : India

    ...more
    Get Best Price
  • Portable Viscometer

    Portable Viscometer

    150,000 - 250,000 / Nos

    • Availability2.0Kg
    • Power Supply230 V AC
    • DisplayTFT High Resolution
    • Brand NameHaico
    • Voltage TypeAC, DC
    • ConditionNew
    • A portable viscometer makes them suitable for use in the field, allowing for immediate measurements and analysis without needing to return to a laboratory setting.Here are some key usages and contexts where portable viscometers are commonly employed: Food and Beverage: Viscosity plays a significant role in the texture and mouthfeel of products. Portable viscometers are used to monitor the viscosity of sauces, soups, and beverages, ensuring product consistency and quality. Oil and Gas: The petroleum industry uses portable viscometers to measure the viscosity of crude oil and other hydrocarbons. Proper viscosity measurements help in the efficient manufacturing processing of these materials. Pharmaceuticals: In the production of medicines, viscosity can affect drug delivery and formulation stability. A portable viscometer allows for in-field testing to ensure that solutions meet the required specifications. Paint and Cosmetics: In paint and cosmetic industry frequently utilizes portable viscometers to assess the viscosity of creams, lotions, and gels. This helps in product formulation and quality assurance. Research and Development: In laboratories, portable viscometers allow for quick and efficient viscosity measurements during the development of new materials or products, facilitating faster iteration and testing. Description Value Display Digital LCD Display Measuring Range 25 to 15Mpas, 15 to 30Mpas, 200 to 120Mpas depending upon the model Rotors B1, B2, B3, B4 4 kinds of rotors RPM 60/100/150/200rpm Sample Size 300 to 600ml Reproducibility ±1%F.S Measurement accuracy +2% Power AC100-240V, 50Hz/60Hz Weight 7kg Body material Die Cast Aluminium Measurement Method Instantaneous Display continuously Lifting system Mechanical Stand optional Bearing system Ruby Torque Spring  material Beryllium Bronze Control system Microprocessor based micro-computer Software system Data Acquisition and save/print Data Temperature probe PT-100
    ...more
  • Portable Viscometer

    Portable Viscometer

    150,000 - 250,000 / Nos

    1 Nos (MOQ)

    A portable viscometer makes them suitable for use in the field, allowing for immediate measurements and analysis without needing to return to a laboratory setting.Here are some key usages and contexts where portable viscometers are commonly employed: Food and Beverage: Viscosity plays a significant role in the texture and mouthfeel of products. Portable viscometers are used to monitor the viscosity of sauces, soups, and beverages, ensuring product consistency and quality. Oil and Gas: The petroleum industry uses portable viscometers to measure the viscosity of crude oil and other hydrocarbons. Proper viscosity measurements help in the efficient manufacturing processing of these materials. Pharmaceuticals: In the production of medicines, viscosity can affect drug delivery and formulation stability. A portable viscometer allows for in-field testing to ensure that solutions meet the required specifications. Paint and Cosmetics: In paint and cosmetic industry frequently utilizes portable viscometers to assess the viscosity of creams, lotions, and gels. This helps in product formulation and quality assurance. Research and Development: In laboratories, portable viscometers allow for quick and efficient viscosity measurements during the development of new materials or products, facilitating faster iteration and testing. Description Value Display Digital LCD Display Measuring Range 25 to 15Mpas, 15 to 30Mpas, 200 to 120Mpas depending upon the model Rotors B1, B2, B3, B4 4 kinds of rotors RPM 60/100/150/200rpm Sample Size 300 to 600ml Reproducibility ±1%F.S Measurement accuracy +2% Power AC100-240V, 50Hz/60Hz Weight 7kg Body material Die Cast Aluminium Measurement Method Instantaneous Display continuously Lifting system Mechanical Stand optional Bearing system Ruby Torque Spring  material Beryllium Bronze Control system Microprocessor based micro-computer Software system Data Acquisition and save/print Data Temperature probe PT-100

    Availability : 2.0Kg

    Power Supply : 230 V AC

    Display : TFT High Resolution

    Brand Name : Haico

    Voltage Type : AC, DC

    Condition : New

    ...more
    Get Best Price
  • Peristaltic Pumps

    Peristaltic Pumps

    50,000 - 120,000 / piece

    • Brand NameHaico
    • Driven TypeAutomatic
    • ConditionNew
    • Power Type200 V A.C. 50Hz
    • Power100-500W
    • PressureLow Pressure
    • ApplicationDosing And Liquid Transfer Accuratly
    • Country of Origin220V
    • Number Of FlowerPeristaltic Pumps
    • Availability10-20kg
    • TheoryRollers In A Peristaltic Pump Compress The Those As They Rotate, Creating A Vacuum Which Draws Fluid
    • StructurePVDF Body And PPS Head
    • Country of OriginIndia
    • Silicon Hose I.D.1-25.4mm
    • MotorHigh Accuracy Stepper Motor
    • Flow rate:0.0001-2416mL/min Time function,preset working time,more convenient. Suitable pump head: DG series,YZ series,BZ series Stepper motor drive,128 times segmentation,high precision,Low vibration,Ultra quiet,work fast,stable Exquisite industrial design, fashion and compact appearance.
    ...more
  • Peristaltic Pumps

    Peristaltic Pumps

    50,000 - 120,000 / piece

    1 piece (MOQ)

    Flow rate:0.0001-2416mL/min Time function,preset working time,more convenient. Suitable pump head: DG series,YZ series,BZ series Stepper motor drive,128 times segmentation,high precision,Low vibration,Ultra quiet,work fast,stable Exquisite industrial design, fashion and compact appearance.

    Brand Name : Haico

    Driven Type : Automatic

    Condition : New

    Power Type : 200 V A.C. 50Hz

    Power : 100-500W

    Pressure : Low Pressure

    Application : Dosing And Liquid Transfer Accuratly

    Country of Origin : 220V

    Number Of Flower : Peristaltic Pumps

    Availability : 10-20kg

    Theory : Rollers In A Peristaltic Pump Compress The Those As They Rotate, Creating A Vacuum Which Draws Fluid

    Structure : PVDF Body And PPS Head

    Country of Origin : India

    ...more
    Get Best Price
  • Oil Test Centrifuge

    Oil Test Centrifuge

    150,000 - 250,000 / Piece

    • ApplicationLaboratory
    • Power250-500Wt
    • Automatic GradeAutomatic
    • ConditionNew
    • Brand NameHaico
    • Haico conforms to the following ASTM standards, ASTM D91 - ASTM D96 - ASTM D893 - ASTM D1796 - ASTM D2273 - ASTM D2709 - ASTM D2711 - ASTM D4007 - ASTM D5546 - API 2542 - API 2548 - BS 4385 - ISO 3734 - ISO 9030 - IP 75 - IP 359 - NFMO 7020. This Oil Test Centrifuge is fully programmable allowing automatic configuration to the specified oil test parameters.This centrifuge is specially designed for water and sediment determination, as well as characterization of used oils and petrol features like demulsibility and precipitation. Available are accessories for 6” and 8” cone-shaped centrifuge tubes, pear-shaped centrifuge tubes.Heating- Preheating program with rotor spinning and temperature is selectable by operator.- Temperature regulation from ambient +5°C up to +80°C (176°F).- Scale Celsius or Fahrenheit.- Temperature sensor in the chamber.User friendliness- TFT touch screen, easy to read and values selection.- Informative display about the progress of stages of centrifugation.- Rotor and adapters list in memory.- Real values on screen of RCF based on accessories configuration.- Start delay - Unbalancing locations system (ULS)- Timer count up/down, for 0 or at “set RPM/RCF” for test reproducibility. From 1 minute to 99 hours, in 1 second steps, and hold position.- Up to 175 acceleration ramps and up to 175 breaking ramps.- Automatic rotor recognition.- Lid latch lock.- Microprocessor controlled.- Induction motor, maintenance free- Up to 4000 RPM/ 2.425 RCF (9 RPM/9 xg steps) Safety- Isolation for reducing the heat loss.- Lid locking and holding.- Imbalance switch-off.- Manual overriding and lid dropping protection.- Chamber of centrifugation made from stainless steel.- Several Programs to keep the operator trouble free about varius Tests.- Guard ring between the chamber of centrifugation and the housing.   Specifications: Max speed 4000rpm Max RCF 2498xg Max volume 4x100ml Noise ≤60dBA Timer 1~99min Net weight 67KG Dimension(LxWxH)mm 685×500×405mm Temperature Range Room temperature:+10~80℃ Speed accuracy ±20rpm Package Wooden box
    ...more
  • Oil Test Centrifuge

    Oil Test Centrifuge

    150,000 - 250,000 / Piece

    1 Piece (MOQ)

    Haico conforms to the following ASTM standards, ASTM D91 - ASTM D96 - ASTM D893 - ASTM D1796 - ASTM D2273 - ASTM D2709 - ASTM D2711 - ASTM D4007 - ASTM D5546 - API 2542 - API 2548 - BS 4385 - ISO 3734 - ISO 9030 - IP 75 - IP 359 - NFMO 7020. This Oil Test Centrifuge is fully programmable allowing automatic configuration to the specified oil test parameters.This centrifuge is specially designed for water and sediment determination, as well as characterization of used oils and petrol features like demulsibility and precipitation. Available are accessories for 6” and 8” cone-shaped centrifuge tubes, pear-shaped centrifuge tubes.Heating- Preheating program with rotor spinning and temperature is selectable by operator.- Temperature regulation from ambient +5°C up to +80°C (176°F).- Scale Celsius or Fahrenheit.- Temperature sensor in the chamber.User friendliness- TFT touch screen, easy to read and values selection.- Informative display about the progress of stages of centrifugation.- Rotor and adapters list in memory.- Real values on screen of RCF based on accessories configuration.- Start delay - Unbalancing locations system (ULS)- Timer count up/down, for 0 or at “set RPM/RCF” for test reproducibility. From 1 minute to 99 hours, in 1 second steps, and hold position.- Up to 175 acceleration ramps and up to 175 breaking ramps.- Automatic rotor recognition.- Lid latch lock.- Microprocessor controlled.- Induction motor, maintenance free- Up to 4000 RPM/ 2.425 RCF (9 RPM/9 xg steps) Safety- Isolation for reducing the heat loss.- Lid locking and holding.- Imbalance switch-off.- Manual overriding and lid dropping protection.- Chamber of centrifugation made from stainless steel.- Several Programs to keep the operator trouble free about varius Tests.- Guard ring between the chamber of centrifugation and the housing.   Specifications: Max speed 4000rpm Max RCF 2498xg Max volume 4x100ml Noise ≤60dBA Timer 1~99min Net weight 67KG Dimension(LxWxH)mm 685×500×405mm Temperature Range Room temperature:+10~80℃ Speed accuracy ±20rpm Package Wooden box

    Application : Laboratory

    Power : 250-500Wt

    Automatic Grade : Automatic

    Condition : New

    Brand Name : Haico

    ...more
    Get Best Price
  • Multiparameter Water Quality Meter

    Multiparameter Water Quality Meter

    50,000 - 150,000 / Piece

    • MaterialPlastic
    • Automatic GradeAutomatic
    • ApplicationIndustrial
    • FeatureDigital Water Meter Display
    • Country of Origin220V
    • Operating Temperature10-50D/C
    • CertificateCE Certified
    • Number Of FlowerWater Testing Meters
    • Country of OriginIndia
    • DisplayLocal
    • Warrenty1 Year
    • Model 900DO pH   Range -2.000~20.000pH Accuracy ±0.002pH Resolution 0.1, 0.01, 0.001pH, Selectable Calibration Points 1 to 5 points Calibration Solutions USA, NIST, DIN or User-defined Temperature Compensation 0~100°C, 32~212°F Compensation Mode Manual or Automatic mV   Range -1999.9~1999.9mV Accuracy ±0.2mV Resolution 0.1, 1mV, Selectable Calibration Points 1 point (Only for Relative mV mode) Calibration Range ±200mV Ion   Range 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Resolution 0.001, 0.01, 0.1, 1 Calibration Points 2 to 5 points Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L Temperature Compensation 0~100°C, 32~212°F Compensation Mode Manual or Automatic Conductivity   Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm Accuracy ±0.5% F.S Calibration Points 1 to 5 points Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic Temperature Coefficient 0.0~10.0%/°C Compensation Modes Linear or Pure Water Cell Constant K=0.1, 1, 10 or User-defined Normalization Temperature 20°C or 25°C TDS   Range 0~100ppt (Max. 200ppt, depending on factor setting) Accuracy ±1% F.S TDS Factor 0.1~1.0 (Default 0.5) Salinity   Range 0~10ppt (Max. 80ppt) Accuracy ±1% F.S Measurement Modes Seawater or Practical Salinity Resistivity   Range 0~100MΩ Accuracy ±1% F.S Resolution 0.01, 0.1, 1 Dissolved Oxygen   Range 0.00~20.00mg/L (or ppm) Accuracy ±0.2mg/L Resolution 0.01mg/L Calibration Points 1 or 2 points Temperature Compensation 0~50°C, 32~122°F, Automatic Pressure Correction 60.0~112.5kPa, 450~850mmHg Salinity Correction 0~50g/L % Saturation of Oxygen   Range 0.0~200.0% Accuracy ±2.0% Resolution 0.1, 1% Temperature   Range 0~105°C, 32~221°F Accuracy ±0.5°C, ±0.9°F Resolution 0.1°C Calibration Points 1 point Calibration Range Measured value ±10°C Others   Hold Function Manual or Automatic endpoint detection Stability Conditions Low or High Calibration Due 0 to 31 days Power Off Manual or Automatic (10, 20, 30 minutes) Reset Function Yes Memory Stores up to 500 data sets Output USB Communication Interface Connector BNC, 6-pin Mini Plug Display LCD (130×110mm) Power Requirements DC5V, using AC adapter, 220VAC/50Hz Dimensions 210(L)×188(W)×60(H)mm Weight 1.5kg
    ...more
  • Multiparameter Water Quality Meter

    Multiparameter Water Quality Meter

    50,000 - 150,000 / Piece

    1 Piece (MOQ)

    Model 900DO pH   Range -2.000~20.000pH Accuracy ±0.002pH Resolution 0.1, 0.01, 0.001pH, Selectable Calibration Points 1 to 5 points Calibration Solutions USA, NIST, DIN or User-defined Temperature Compensation 0~100°C, 32~212°F Compensation Mode Manual or Automatic mV   Range -1999.9~1999.9mV Accuracy ±0.2mV Resolution 0.1, 1mV, Selectable Calibration Points 1 point (Only for Relative mV mode) Calibration Range ±200mV Ion   Range 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Resolution 0.001, 0.01, 0.1, 1 Calibration Points 2 to 5 points Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L Temperature Compensation 0~100°C, 32~212°F Compensation Mode Manual or Automatic Conductivity   Range 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm Accuracy ±0.5% F.S Calibration Points 1 to 5 points Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic Temperature Coefficient 0.0~10.0%/°C Compensation Modes Linear or Pure Water Cell Constant K=0.1, 1, 10 or User-defined Normalization Temperature 20°C or 25°C TDS   Range 0~100ppt (Max. 200ppt, depending on factor setting) Accuracy ±1% F.S TDS Factor 0.1~1.0 (Default 0.5) Salinity   Range 0~10ppt (Max. 80ppt) Accuracy ±1% F.S Measurement Modes Seawater or Practical Salinity Resistivity   Range 0~100MΩ Accuracy ±1% F.S Resolution 0.01, 0.1, 1 Dissolved Oxygen   Range 0.00~20.00mg/L (or ppm) Accuracy ±0.2mg/L Resolution 0.01mg/L Calibration Points 1 or 2 points Temperature Compensation 0~50°C, 32~122°F, Automatic Pressure Correction 60.0~112.5kPa, 450~850mmHg Salinity Correction 0~50g/L % Saturation of Oxygen   Range 0.0~200.0% Accuracy ±2.0% Resolution 0.1, 1% Temperature   Range 0~105°C, 32~221°F Accuracy ±0.5°C, ±0.9°F Resolution 0.1°C Calibration Points 1 point Calibration Range Measured value ±10°C Others   Hold Function Manual or Automatic endpoint detection Stability Conditions Low or High Calibration Due 0 to 31 days Power Off Manual or Automatic (10, 20, 30 minutes) Reset Function Yes Memory Stores up to 500 data sets Output USB Communication Interface Connector BNC, 6-pin Mini Plug Display LCD (130×110mm) Power Requirements DC5V, using AC adapter, 220VAC/50Hz Dimensions 210(L)×188(W)×60(H)mm Weight 1.5kg

    Material : Plastic

    Automatic Grade : Automatic

    Application : Industrial

    Feature : Digital Water Meter Display

    Country of Origin : 220V

    Operating Temperature : 10-50D/C

    Certificate : CE Certified

    Number Of Flower : Water Testing Meters

    Country of Origin : India

    Display : Local

    Warrenty : 1 Year

    ...more
    Get Best Price
  • Muffle Furnace

    Muffle Furnace

    30,000 - 100,000 / Nos

    • Power Supply220 V A.C. 50Hz
    • Brand NameHaico
    • MaterialIron, Stainless Steel
    • Driven TypeElectric
    • Packaging TypeAs per Customer's requirement
    • ConditionNew
    • Rated Power1-3kw, 3-6kw, 6-9kw, 9-12kw
    • Power SourceSingle Phase
    • Automation GradeAutomatic, Fully Automatic, Semi Automatic
    • ApplicationHeating Process
    • Country of Origin220V
    • Capacity2 to 216 lit
    • Quality1
    • Type Of FurnaceElectric
    • Number Of FlowerMuffle Furnace
    • Availability100-300kg, 300-500kg, 30 -100kg
    • Total Carbohydrate1yrs
    • After-Sales Service ProvidedYes
    • Country of OriginIndia
    • Max Temperature1800
    • Input Voltage230 V AC
    • HAICO Muffle Furnace is a kind of front loading box type kiln, which is used to create extremely high temperature required to perform various heat treatment processes such as annealing, ash determination and coal analysis etc. The heating temperature inside muffle furnace chamber may vary between 900°C to 1400°C and high temperature 1600°C to 1800°C. The key usage of a laboratory muffle furnace is to evaluate characteristics of materials under high heat; therefore, it is widely used in industrial and laboratory research facilities and some educational projects. Depending upon applications and sample sizes, it is available in different dimensions and material of construction etc; furthermore, a number of accessories such as printer and temperature chart recorder can also be fitted to keep records of batch name, furnace temperature, date and time. In addition to supply with-in India, we also export our muffle furnace to USA, Greece, Germany, UAE, Kuwait, Africa, Zambia, Australia, Philippines and Vietnam etc. Construction Our muffle furnaces are durable, ruggedly designed and offer long service life. The outer body (case) is made of thick mild steel (18 / 20 gauge) powder coated and optional GMP (SS 304 / 316) shaped with welded joints and branded nuts bolts and screws. Inner chamber (heating zone) is made of Ceramic tile (up to 1200°C), Zirconia board (Up to 1600°C) and high alumina bricks (1800°C). Control Panel A control panel has everything you need to run a muffle furnace. Power on/off MCB, programmable controller, indicators and electric meters etc. are fitted at control panel. Depending on design, a control panel can be designed at right side or bottom of the unit. Heating Elements In order to achieve higher accuracy, we use only imported and branded heating elements for our muffle furnace; for up to 1100°C temperature, we use Kanthal A-1 heating elements, from 1200°C to 1600°C Silicon carbide (SiC) heating elements are used. molybdenum Disilicide (MoSi2) heating elements are used for 1800°C muffle furnace. Controller A controller is a device which sets temperature of a muffle furnace; we use various controllers that are branded and deliver high temperature accuracy. We use digital PID controller, programmable controller with ramp and soak modes and PLC with HMI interface; it is totally customers' choice which type of controller he needs in his muffle furnace. Optional Accessories When comes to custom designing of laboratory muffle furnace, accessories play an important part; crucibles, heating elements, temperature controllers, tongs and gloves and switches are always available in stock with us. Muffle Furnace Specifications Max. Temperature 1100°C 1400°C 1800°C Working Temperature 1000°C 1300°C 1700°C Thermocouple K Type R Type B-Type  (Pt-Rh to Pt-Rh) with Alumina tube Heating element Kanthal Wire Silicon carbide MoSi2 Inner Chamber Ceramic tile Zirconium board Ceramic fiber board Insulation Ceramic fiber Ceramic fiber Ceramic fiber Controller PID Controller PID Controller 30 segments PID Controller Power supply 220 Volts 50Hz 440 Volts 50Hz 220 Volts 50Hz Standard Size (Inch)(W x H x D) 4 x 4 x 95 x 5 x 106 x 6 x 129 x 9 x 18 4 x 4 x 95 x 5 x 106 x 6 x 129 x 9 x 18 4 x 4 x 44 x 4 x 88 x 8 x 88 x 8 x 12 Accessories Stainless steel TongOne pair of furnace gloves  
    ...more
  • Muffle Furnace

    Muffle Furnace

    30,000 - 100,000 / Nos

    1 Nos (MOQ)

    HAICO Muffle Furnace is a kind of front loading box type kiln, which is used to create extremely high temperature required to perform various heat treatment processes such as annealing, ash determination and coal analysis etc. The heating temperature inside muffle furnace chamber may vary between 900°C to 1400°C and high temperature 1600°C to 1800°C. The key usage of a laboratory muffle furnace is to evaluate characteristics of materials under high heat; therefore, it is widely used in industrial and laboratory research facilities and some educational projects. Depending upon applications and sample sizes, it is available in different dimensions and material of construction etc; furthermore, a number of accessories such as printer and temperature chart recorder can also be fitted to keep records of batch name, furnace temperature, date and time. In addition to supply with-in India, we also export our muffle furnace to USA, Greece, Germany, UAE, Kuwait, Africa, Zambia, Australia, Philippines and Vietnam etc. Construction Our muffle furnaces are durable, ruggedly designed and offer long service life. The outer body (case) is made of thick mild steel (18 / 20 gauge) powder coated and optional GMP (SS 304 / 316) shaped with welded joints and branded nuts bolts and screws. Inner chamber (heating zone) is made of Ceramic tile (up to 1200°C), Zirconia board (Up to 1600°C) and high alumina bricks (1800°C). Control Panel A control panel has everything you need to run a muffle furnace. Power on/off MCB, programmable controller, indicators and electric meters etc. are fitted at control panel. Depending on design, a control panel can be designed at right side or bottom of the unit. Heating Elements In order to achieve higher accuracy, we use only imported and branded heating elements for our muffle furnace; for up to 1100°C temperature, we use Kanthal A-1 heating elements, from 1200°C to 1600°C Silicon carbide (SiC) heating elements are used. molybdenum Disilicide (MoSi2) heating elements are used for 1800°C muffle furnace. Controller A controller is a device which sets temperature of a muffle furnace; we use various controllers that are branded and deliver high temperature accuracy. We use digital PID controller, programmable controller with ramp and soak modes and PLC with HMI interface; it is totally customers' choice which type of controller he needs in his muffle furnace. Optional Accessories When comes to custom designing of laboratory muffle furnace, accessories play an important part; crucibles, heating elements, temperature controllers, tongs and gloves and switches are always available in stock with us. Muffle Furnace Specifications Max. Temperature 1100°C 1400°C 1800°C Working Temperature 1000°C 1300°C 1700°C Thermocouple K Type R Type B-Type  (Pt-Rh to Pt-Rh) with Alumina tube Heating element Kanthal Wire Silicon carbide MoSi2 Inner Chamber Ceramic tile Zirconium board Ceramic fiber board Insulation Ceramic fiber Ceramic fiber Ceramic fiber Controller PID Controller PID Controller 30 segments PID Controller Power supply 220 Volts 50Hz 440 Volts 50Hz 220 Volts 50Hz Standard Size (Inch)(W x H x D) 4 x 4 x 95 x 5 x 106 x 6 x 129 x 9 x 18 4 x 4 x 95 x 5 x 106 x 6 x 129 x 9 x 18 4 x 4 x 44 x 4 x 88 x 8 x 88 x 8 x 12 Accessories Stainless steel TongOne pair of furnace gloves  

    Power Supply : 220 V A.C. 50Hz

    Brand Name : Haico

    Material : Iron, Stainless Steel

    Driven Type : Electric

    Packaging Type : As per Customer's requirement

    Condition : New

    Rated Power : 1-3kw, 3-6kw, 6-9kw, 9-12kw

    Power Source : Single Phase

    Automation Grade : Automatic, Fully Automatic, Semi Automatic

    Application : Heating Process

    Country of Origin : 220V

    Capacity : 2 to 216 lit

    Quality : 1

    Type Of Furnace : Electric

    Number Of Flower : Muffle Furnace

    Availability : 100-300kg, 300-500kg, 30 -100kg

    Total Carbohydrate : 1yrs

    After-Sales Service Provided : Yes

    Country of Origin : India

    Max Temperature : 1800

    Input Voltage : 230 V AC

    ...more
    Get Best Price
  • Laboratory Hot Air Oven

    Laboratory Hot Air Oven

    30,000 - 60,000 / Nos

    • Brand NameHaico
    • MaterialStainless Steel, Mild Steel
    • MaterialMS Powder Coated
    • Driven TypeElectric
    • ConditionNew
    • Power5-10kw
    • ApplicationLaboratory Use
    • FeatureStable Performance, Rust Resistance, Low Maintenance, Long Life, Fast Heating, Energy Saving Certified, Auto Cut
    • Country of Origin220V
    • Display TypeDigital
    • Storage Capacity50-100L, 200-400L, 100-200L, 0-50L
    • Number Of FlowerLaboratory Hot Air Oven
    • Availability0-500kg
    • Frequency50Hz
    • Temperature RangeAmb.+5 to 250 Deg. C
    • Total Carbohydrate1yr
    • Country of OriginIndia
    • Max Temperature250
    • Surface FinishMatt or Glossy
    • Temperature50-100°C, 200-400°C, 100-200°C
    • Number Of Shelves3-6
    • OriginIndia
    • No Of Chamber1
    • Accuracy Of Thermostat0.25
    • Hot air ovens can be used for sterilization. There are two types of hot air ovens: forced air and static air. Forced air ovens are more effective than static air ovens. specifications for hot air ovens:    Temperature range: 40°C to 250°C Temperature variation: +/- 0.5°C Temperature accuracy: ±0.25°C Uniformity: ± 2.0 at 100.0°C Temperature controller: Microprocessor based Auto tune Fuzzy Logic ‑ PID controller Temperature sensors: PT-100 Type Features of hot air ovens:      Uniform air circulation across chamber Digital temperature controller cum indicator Stainless steel inner chamber Corrosion resistant exterior Fume ventilation points on both sides Stainless Steel wire mesh cable trays
    ...more
  • Laboratory Hot Air Oven

    Laboratory Hot Air Oven

    30,000 - 60,000 / Nos

    1 Piece (MOQ)

    Hot air ovens can be used for sterilization. There are two types of hot air ovens: forced air and static air. Forced air ovens are more effective than static air ovens. specifications for hot air ovens:    Temperature range: 40°C to 250°C Temperature variation: +/- 0.5°C Temperature accuracy: ±0.25°C Uniformity: ± 2.0 at 100.0°C Temperature controller: Microprocessor based Auto tune Fuzzy Logic ‑ PID controller Temperature sensors: PT-100 Type Features of hot air ovens:      Uniform air circulation across chamber Digital temperature controller cum indicator Stainless steel inner chamber Corrosion resistant exterior Fume ventilation points on both sides Stainless Steel wire mesh cable trays

    Brand Name : Haico

    Material : Stainless Steel, Mild Steel

    Material : MS Powder Coated

    Driven Type : Electric

    Condition : New

    Power : 5-10kw

    Application : Laboratory Use

    Feature : Stable Performance, Rust Resistance, Low Maintenance, Long Life, Fast Heating, Energy Saving Certified, Auto Cut

    Country of Origin : 220V

    Display Type : Digital

    Storage Capacity : 50-100L, 200-400L, 100-200L, 0-50L

    Number Of Flower : Laboratory Hot Air Oven

    Availability : 0-500kg

    Frequency : 50Hz

    Temperature Range : Amb.+5 to 250 Deg. C

    Total Carbohydrate : 1yr

    Country of Origin : India

    Max Temperature : 250

    Surface Finish : Matt or Glossy

    Temperature : 50-100°C, 200-400°C, 100-200°C

    Number Of Shelves : 3-6

    Origin : India

    No Of Chamber : 1

    Accuracy Of Thermostat : 0.25

    ...more
    Get Best Price
  • Hplc System

    Hplc System

    800,000 / Piece

    • Driven TypeElectric
    • Voltage220V
    • ApplicationLaboratory
    • Power1-5kw
    • Automatic GradeFully Automatic
    • ConditionNew
    • ColorLight White
    • About this product Includes generated contents n Portable and Compact Design: This liquid chromatograph is designed to be portable and compact, making it ideal for use in various industrial settings, including laboratories and testing facilities, as required by our valued customer in the chemical industry. n High Accuracy and Precision: With an accuracy of ± 0.1 and a linearity range of 0-106, this HPLC system ensures reliable and precise results, meeting the expectations of our customer in the pharmaceutical sector. n Multi-Detector Capability: Equipped with 3 detectors, including a double FID and a TCD, this HPLC system provides comprehensive analysis capabilities, meeting the needs of our customers in the food safety testing industry. n Customized Support and OEM Options: Our HPLC system offers customized support and OEM options, allowing for tailored solutions to meet the specific requirements of our customers in the chemical and pharmaceutical industries. n Long-Lasting Performance: With a temperature range of 8°C to 45°C and a baseline drift of 30 V/30 min, this HPLC system ensures long-lasting performance and reliability, meeting the demands of our customers in the quality control sector. System Configuration* Isocratic system* High-pressure binary gradient system* Quaternary low-pressure gradient system* ELITE-AAK/AAP amino acid analytical system Characteristics1) Classic short stroke,serial pitsons,and multi-stage flow correction ensuring pump performance.2) Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.3) Self-development PID control measure bringing true the accuracy of column oven temperature to 0.1℃.4) The brand-new S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.5) Application of optoelectronic isolation and EMI protection ensuring stable communication.6) All-round upgraded Chromsoft workstation that is operator-friendly and promotes customer experience. Configuration Table 1 P3100 High Pressure Constant Flow Pump 1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)3) Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)4) Maximum pressure: 45 MPa5) Pressure accuracy: ≤±3.0%6) Pressure pulsation: ≤0.1 MPa 2 UV3100 UV/VIS Detector * Wavelength range: 190-700 nm* Wavelength repeatability: ≤0.1 nm* Wavelength accuracy: ≤±1.0 nm* Bandwidth: 8nm* Response time: 0.0 s-5 s* Baseline noise: ≤±0.5×10-5 AU* Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)* Path length: 10 mm(analytical cell)* Light source: Deuterium Lamp 3 Chromsoft Chromatographic Data-processing Workstation * Internal and external standard calculation methods* Automatically displays, prints, exports and starts other programs after the completion of a measurement. 4 GD-3100 System Kits * Containing required tubing, fittings, wreches and cables for system.* 7725i manual injector* TD-1-15 static mixer* Supersil ODS2 5μm ID4.6*200mm 5 S3100 Autosampler(optional) * Inject volum range: 0-100 μL (standard)* Precision: RSD 0.999* Sample residual:
    ...more
  • Hplc System

    Hplc System

    800,000 / Piece

    1 Piece (MOQ)

    About this product Includes generated contents n Portable and Compact Design: This liquid chromatograph is designed to be portable and compact, making it ideal for use in various industrial settings, including laboratories and testing facilities, as required by our valued customer in the chemical industry. n High Accuracy and Precision: With an accuracy of ± 0.1 and a linearity range of 0-106, this HPLC system ensures reliable and precise results, meeting the expectations of our customer in the pharmaceutical sector. n Multi-Detector Capability: Equipped with 3 detectors, including a double FID and a TCD, this HPLC system provides comprehensive analysis capabilities, meeting the needs of our customers in the food safety testing industry. n Customized Support and OEM Options: Our HPLC system offers customized support and OEM options, allowing for tailored solutions to meet the specific requirements of our customers in the chemical and pharmaceutical industries. n Long-Lasting Performance: With a temperature range of 8°C to 45°C and a baseline drift of 30 V/30 min, this HPLC system ensures long-lasting performance and reliability, meeting the demands of our customers in the quality control sector. System Configuration* Isocratic system* High-pressure binary gradient system* Quaternary low-pressure gradient system* ELITE-AAK/AAP amino acid analytical system Characteristics1) Classic short stroke,serial pitsons,and multi-stage flow correction ensuring pump performance.2) Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.3) Self-development PID control measure bringing true the accuracy of column oven temperature to 0.1℃.4) The brand-new S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.5) Application of optoelectronic isolation and EMI protection ensuring stable communication.6) All-round upgraded Chromsoft workstation that is operator-friendly and promotes customer experience. Configuration Table 1 P3100 High Pressure Constant Flow Pump 1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)3) Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)4) Maximum pressure: 45 MPa5) Pressure accuracy: ≤±3.0%6) Pressure pulsation: ≤0.1 MPa 2 UV3100 UV/VIS Detector * Wavelength range: 190-700 nm* Wavelength repeatability: ≤0.1 nm* Wavelength accuracy: ≤±1.0 nm* Bandwidth: 8nm* Response time: 0.0 s-5 s* Baseline noise: ≤±0.5×10-5 AU* Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)* Path length: 10 mm(analytical cell)* Light source: Deuterium Lamp 3 Chromsoft Chromatographic Data-processing Workstation * Internal and external standard calculation methods* Automatically displays, prints, exports and starts other programs after the completion of a measurement. 4 GD-3100 System Kits * Containing required tubing, fittings, wreches and cables for system.* 7725i manual injector* TD-1-15 static mixer* Supersil ODS2 5μm ID4.6*200mm 5 S3100 Autosampler(optional) * Inject volum range: 0-100 μL (standard)* Precision: RSD 0.999* Sample residual:

    Driven Type : Electric

    ...more
    Get Best Price
  • Fully Automatic Bomb Calorie Meter

    Fully Automatic Bomb Calorie Meter

    55,000 - 450,000 / Piece

    • Brand NameHaico
    • Power230 V AC
    • Power SourceElectric
    • Automation GradeAutomatic, Fully Automatic
    • ApplicationIndustrial Use
    • Model Name/Number HCO-BC-02 Automation Grade Fully automatic Usage/Application for Coal, Husk, Wood Pallets, Oil etc. Operating Time Per Test 10 to 15 mins Country of Origin Made in India   Key features: 1. Automatic digital bomb calorimeter 2. Automatic calculation & display of calorific value 3. Puff insulated water jacket 4. Readability of 0.01 Deg. C in ambient & rising temp. 5. Accuracy of ± 0.01 Deg. C inrising temp. 6. Accuracy of calorific value ± 50 calories. 7. Menu key is provided to select type of test i.e. calibration / waterequivalent, gcv sample test. 8. Numeric digits 0-9 are provided on the front panel for feeding values such as weight of the tablet, waterequivalent values etc. 9. New SS304 rod waterproof long life sensor.   Pre installation requirement:-  fresh oxygen cylinder (industrial grade),Digital weighing balance atleast (0. 001g),5-10 liters dm / distilled water. supplied complete with 24accessories like puff- insulated jacket, safety device, S. S. Bomb
    ...more
  • Fully Automatic Bomb Calorie Meter

    Fully Automatic Bomb Calorie Meter

    55,000 - 450,000 / Piece

    1 Piece (MOQ)

    Model Name/Number HCO-BC-02 Automation Grade Fully automatic Usage/Application for Coal, Husk, Wood Pallets, Oil etc. Operating Time Per Test 10 to 15 mins Country of Origin Made in India   Key features: 1. Automatic digital bomb calorimeter 2. Automatic calculation & display of calorific value 3. Puff insulated water jacket 4. Readability of 0.01 Deg. C in ambient & rising temp. 5. Accuracy of ± 0.01 Deg. C inrising temp. 6. Accuracy of calorific value ± 50 calories. 7. Menu key is provided to select type of test i.e. calibration / waterequivalent, gcv sample test. 8. Numeric digits 0-9 are provided on the front panel for feeding values such as weight of the tablet, waterequivalent values etc. 9. New SS304 rod waterproof long life sensor.   Pre installation requirement:-  fresh oxygen cylinder (industrial grade),Digital weighing balance atleast (0. 001g),5-10 liters dm / distilled water. supplied complete with 24accessories like puff- insulated jacket, safety device, S. S. Bomb

    Brand Name : Haico

    Power : 230 V AC

    Power Source : Electric

    Automation Grade : Automatic, Fully Automatic

    Application : Industrial Use

    ...more
    Get Best Price
  • Digital Vortex Mixer

    Digital Vortex Mixer

    10,000 - 50,000 / Piece

    • ConditionNew
    • Automation GradeSemi-Automatic
    • ApplicationShaking Test Tube
    • Country of Origin220V
    • Number Of FlowerVortexer
    • Availability0-15 Kg
    • Frequency50 Hz
    • Orbit 6mm Brand Haico Power 230 V AC Voltage 220 240 V Frequency 50Hz Warranty 12 months Weight 3 kg Dimensions (W X D X H) 107x146x166mm Permissible relative humidity 5 to 90% RH Permissible Ambient Temperature 10 to 40 Deg. Centigrade   A laboratory vortex mixer is a laboratory equipment used to mix and blend various substances, such as liquids, powders, and gases, in a controlled and precise manner. It is commonly used in scientific research, quality control, and manufacturing processes. It is used in the rapid mixing of samples. This type of mixer has a small footprint with a high rpm to create a vortex effect, which helps to mix and blend the substances efficiently and effectively. Laboratory vortex mixers are available in various sizes and types, including digital and analog models, and are often used in industries such as pharmaceuticals, biotechnology, and chemistry. · Multipurpose High-Speed Vortex Mixer: Lab vortex shakers have the 0-3000rpm adjustable speed to meet different mixing needs. Able to mix liquid in biological, laboratory, nail polish, eyelash extensions glue, inks, model hobby paint, miniature paints, acrylic paints, etc. Compatible with most bottles, lab tubes, and pots with platform pad. · Excellent Mixing Capacity: This lab vortex shaker Orbital diameter is 35mm, can mix a larger amount of liquid in one time. Our mix machine can fix full 50ml containers within 3 seconds. Save the headache of hand shaking hundreds of bottles of paint. · More Stable Vortex Paint Shaker: Aluminum casting base with 4 suction cups on the bottom keep the machine firmly working on a table, when combined with heavy weight (5.13lb), reducing the surface vibration tremendously, even at 3000rpm.It can also avoid scratching the table. · 2 Simple Operation Modes: The paint vortex mixer machine is simple to operate. Continuous Mode: plug it in, turn it on, then the mixing will stats immediately until you turn off the power. Touch Mode: simply push the tube into the top to start shaking, and shaking stops as soon as the tube is lifted. Mix more thoroughly in a shorter time. Easy to maintain and clean. · Safer Laboratory Vortex Mixer: 12v low voltage, to ensure laboratory safety, DC brushless motor, high efficiency, small wear, low failure rate. lifespan is about 6 times longer than a brushed motor. The power supply is certified by TUV. Excellent enough to invest in a nail polish mixer with professional customer support.
    ...more
  • Digital Vortex Mixer

    Digital Vortex Mixer

    10,000 - 50,000 / Piece

    1 Piece (MOQ)

    Orbit 6mm Brand Haico Power 230 V AC Voltage 220 240 V Frequency 50Hz Warranty 12 months Weight 3 kg Dimensions (W X D X H) 107x146x166mm Permissible relative humidity 5 to 90% RH Permissible Ambient Temperature 10 to 40 Deg. Centigrade   A laboratory vortex mixer is a laboratory equipment used to mix and blend various substances, such as liquids, powders, and gases, in a controlled and precise manner. It is commonly used in scientific research, quality control, and manufacturing processes. It is used in the rapid mixing of samples. This type of mixer has a small footprint with a high rpm to create a vortex effect, which helps to mix and blend the substances efficiently and effectively. Laboratory vortex mixers are available in various sizes and types, including digital and analog models, and are often used in industries such as pharmaceuticals, biotechnology, and chemistry. · Multipurpose High-Speed Vortex Mixer: Lab vortex shakers have the 0-3000rpm adjustable speed to meet different mixing needs. Able to mix liquid in biological, laboratory, nail polish, eyelash extensions glue, inks, model hobby paint, miniature paints, acrylic paints, etc. Compatible with most bottles, lab tubes, and pots with platform pad. · Excellent Mixing Capacity: This lab vortex shaker Orbital diameter is 35mm, can mix a larger amount of liquid in one time. Our mix machine can fix full 50ml containers within 3 seconds. Save the headache of hand shaking hundreds of bottles of paint. · More Stable Vortex Paint Shaker: Aluminum casting base with 4 suction cups on the bottom keep the machine firmly working on a table, when combined with heavy weight (5.13lb), reducing the surface vibration tremendously, even at 3000rpm.It can also avoid scratching the table. · 2 Simple Operation Modes: The paint vortex mixer machine is simple to operate. Continuous Mode: plug it in, turn it on, then the mixing will stats immediately until you turn off the power. Touch Mode: simply push the tube into the top to start shaking, and shaking stops as soon as the tube is lifted. Mix more thoroughly in a shorter time. Easy to maintain and clean. · Safer Laboratory Vortex Mixer: 12v low voltage, to ensure laboratory safety, DC brushless motor, high efficiency, small wear, low failure rate. lifespan is about 6 times longer than a brushed motor. The power supply is certified by TUV. Excellent enough to invest in a nail polish mixer with professional customer support.

    Condition : New

    Automation Grade : Semi-Automatic

    Application : Shaking Test Tube

    Country of Origin : 220V

    Number Of Flower : Vortexer

    Availability : 0-15 Kg

    Frequency : 50 Hz

    ...more
    Get Best Price
  • Digital Rotational Viscometer

    Digital Rotational Viscometer

    50,000 - 150,000 / piece

    • Brand NameHaico
    • Voltage TypeAC
    • ConditionNew
    • ApplicationQuality Testing of Liquid
    • CertificationCE Certified
    • FeatureAccuracy, Easy To Use, Sturdy Construction
    • Number Of FlowerRotational Viscometer
    • Frequency0-50Hz
    • Total Carbohydrate1yr
    • Country of OriginIndia
    • DisplayDigital
    • Viscosity20-6,000,000 mPas
    • Digital Direct Reading Rotational Viscometer:- LMDV series is Rotational Digital Direct Reading Viscometer to measure absolute viscosity of Newton Liquids as well apparent viscosity of non-Newton liquid featured by high flexibility reliable Test result, easy operation and good appearance. MODEL HCOLMDV60 HCOLMDV100 HCOLMDV200 Make HAICO Measuring Range mpa.s 20-2,000,000 20-2,000,000 20-6,000,000 Speed 0.3 to 60 0.3 to 100 0.1 to 200 No of Speed 8 18 54 No of Standard Spindle 4 Display LCD Temperature Monitoring Yes Measurement Accuracy + / - 1% (FS) Repeatability + / - 0.5 % (FS) Output RS232C Interface Power Supply AC 220V / 50Hz Dimension LxWxH (mm) 400 x 350 x 360 Weight 9 kg 10 kg
    ...more
  • Digital Rotational Viscometer

    Digital Rotational Viscometer

    50,000 - 150,000 / piece

    1 Set (MOQ)

    Digital Direct Reading Rotational Viscometer:- LMDV series is Rotational Digital Direct Reading Viscometer to measure absolute viscosity of Newton Liquids as well apparent viscosity of non-Newton liquid featured by high flexibility reliable Test result, easy operation and good appearance. MODEL HCOLMDV60 HCOLMDV100 HCOLMDV200 Make HAICO Measuring Range mpa.s 20-2,000,000 20-2,000,000 20-6,000,000 Speed 0.3 to 60 0.3 to 100 0.1 to 200 No of Speed 8 18 54 No of Standard Spindle 4 Display LCD Temperature Monitoring Yes Measurement Accuracy + / - 1% (FS) Repeatability + / - 0.5 % (FS) Output RS232C Interface Power Supply AC 220V / 50Hz Dimension LxWxH (mm) 400 x 350 x 360 Weight 9 kg 10 kg

    Brand Name : Haico

    Voltage Type : AC

    Condition : New

    Application : Quality Testing of Liquid

    Certification : CE Certified

    Feature : Accuracy, Easy To Use, Sturdy Construction

    Number Of Flower : Rotational Viscometer

    Frequency : 0-50Hz

    Total Carbohydrate : 1yr

    Country of Origin : India

    Display : Digital

    Viscosity : 20-6,000,000 mPas

    ...more
    Get Best Price
  • Digital Hot Plate with Safety Control

    Digital Hot Plate with Safety Control

    5,000 - 15,000 / Piece

    • Brand NameHaico
    • Housing MaterialSS 304
    • ShapeRectangular
    • ConditionNew
    • Automatic GradeFully Automatic
    • Power1-3kw
    • Power SourceElectric
    • ApplicationLaboratory Use
    • FeatureAuto Cut, Fast Heating, Long Life, Low Maintenance, Rust Resistance, Shocked Proof, Stable Performance
    • Country of Origin220V
    • Availability10kg
    • Max. Current2400 watts
    • Max. Voltage240
    • Mechanical Life10 yrs
    • Total Carbohydrate1year
    • Country of OriginIndia
    • temprature200-400°C
    • HAICO Hot Plate, Digital offers even more precise temperature control. It is available in various sizes and top plates. The surfaces are available in rectangular shapes, with a surface temperature range of 350°C. The outside cabinet is constructed of powder coated mild steel, and the heating surface is made of cast iron or 6mm stainless Steel. These hot plates are ideal for applications requiring precise and consistent temperature control of liquid solution. Features: Different capacities for various laboratory need PID technology provides precise temperature control Measure/control the liquid temperature directly LED display for SET and ACTUAL temperature Powder coated MS or SS body for durability Rectangular cast-iron or thick SS top plate Non-slip rubber feet Overload Protection Digital Overheat Protection Technical Specifications:   Temperature Range: ambient ±5 to 350°C Accuracy: ±0.5°C; Resolution – 0.1°C Temperature Control: Digital PID fuzzy Logic controller Temperature Probe PT100 Input voltage: 230VAC ± 10, 50-60 Hz Pwer Rating: 1200 to 2400 Watts
    ...more
  • Digital Hot Plate with Safety Control

    Digital Hot Plate with Safety Control

    5,000 - 15,000 / Piece

    1 Nos (MOQ)

    HAICO Hot Plate, Digital offers even more precise temperature control. It is available in various sizes and top plates. The surfaces are available in rectangular shapes, with a surface temperature range of 350°C. The outside cabinet is constructed of powder coated mild steel, and the heating surface is made of cast iron or 6mm stainless Steel. These hot plates are ideal for applications requiring precise and consistent temperature control of liquid solution. Features: Different capacities for various laboratory need PID technology provides precise temperature control Measure/control the liquid temperature directly LED display for SET and ACTUAL temperature Powder coated MS or SS body for durability Rectangular cast-iron or thick SS top plate Non-slip rubber feet Overload Protection Digital Overheat Protection Technical Specifications:   Temperature Range: ambient ±5 to 350°C Accuracy: ±0.5°C; Resolution – 0.1°C Temperature Control: Digital PID fuzzy Logic controller Temperature Probe PT100 Input voltage: 230VAC ± 10, 50-60 Hz Pwer Rating: 1200 to 2400 Watts

    Brand Name : Haico

    Housing Material : SS 304

    Shape : Rectangular

    Condition : New

    Automatic Grade : Fully Automatic

    Power : 1-3kw

    Power Source : Electric

    Application : Laboratory Use

    Feature : Auto Cut, Fast Heating, Long Life, Low Maintenance, Rust Resistance, Shocked Proof, Stable Performance

    Country of Origin : 220V

    Availability : 10kg

    Max. Current : 2400 watts

    Max. Voltage : 240

    Mechanical Life : 10 yrs

    Total Carbohydrate : 1year

    Country of Origin : India

    temprature : 200-400°C

    ...more
    Get Best Price
  • Circulating Chiller

    Circulating Chiller

    25,000 - 85,000 / Piece

    • Brand NameHaico
    • MaterialStainless Steel
    • FinishingPolished
    • Driven TypeElectric
    • Power1-3kw
    • Chiller ShapeRectangular
    • Usage Laboratory Automation Grade Fully Automatic Color Black and White No. Of Compressor One Refrigerant Used CFC free Warranty 12 months Frequency Hz 50Hz   Refrigerated Thermostatic Bath and Heating Circulators   The series of Refrigerated thermostatic bath has adopted the latest international advanced CFC-free refrigeration system. The main components used are imported and the performance is stable and reliable. It is widely used in research institutes, universities, corporate quality control departments and industrial sectors relating to petroleum, chemical engineering, electronic instruments, physics, chemistry, bio-engineering, medicine and health, life science, light industry and food, materials testing and chemical analysis etc. It is used to put trial samples or newly made products to a constant-temperature test. It can also be used as a heat source or cold source for a direct heating or cooling and auxiliary heating or cooling.   Features: ● Using environmentally friendly CFC-free refrigeration technology to meet the requirements of environmental protection. ● Using high-quality full-enclosed air-cooled compressor cooling system, low noise ● Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically ● with a power-off protection function, automatically delayed for three minutes ● using a TFT touch screen, easy to understand working condition ● Intelligent PID automatically adjust control function ● Upper and lower temperature alarm can be set ● with over heat alarm system to ensure the safety apparatus ● Inner high-quality stainless steel material ● with external circulating pump, can be established the second constant temperature field outside the bath ● Cold liquid can be cited outside the tank, cooling the experimental container outside the bath ● Using analogue theory, automatic identify the difference between set temperature and the ambient temperature, to confirm whether a single heating or cooling heating work simultaneously to achieve the energy saving.
    ...more
  • Circulating Chiller

    Circulating Chiller

    25,000 - 85,000 / Piece

    1 Piece (MOQ)

    Usage Laboratory Automation Grade Fully Automatic Color Black and White No. Of Compressor One Refrigerant Used CFC free Warranty 12 months Frequency Hz 50Hz   Refrigerated Thermostatic Bath and Heating Circulators   The series of Refrigerated thermostatic bath has adopted the latest international advanced CFC-free refrigeration system. The main components used are imported and the performance is stable and reliable. It is widely used in research institutes, universities, corporate quality control departments and industrial sectors relating to petroleum, chemical engineering, electronic instruments, physics, chemistry, bio-engineering, medicine and health, life science, light industry and food, materials testing and chemical analysis etc. It is used to put trial samples or newly made products to a constant-temperature test. It can also be used as a heat source or cold source for a direct heating or cooling and auxiliary heating or cooling.   Features: ● Using environmentally friendly CFC-free refrigeration technology to meet the requirements of environmental protection. ● Using high-quality full-enclosed air-cooled compressor cooling system, low noise ● Full-enclosed air-cooled compressor cooling system with thermal overload protection automatically ● with a power-off protection function, automatically delayed for three minutes ● using a TFT touch screen, easy to understand working condition ● Intelligent PID automatically adjust control function ● Upper and lower temperature alarm can be set ● with over heat alarm system to ensure the safety apparatus ● Inner high-quality stainless steel material ● with external circulating pump, can be established the second constant temperature field outside the bath ● Cold liquid can be cited outside the tank, cooling the experimental container outside the bath ● Using analogue theory, automatic identify the difference between set temperature and the ambient temperature, to confirm whether a single heating or cooling heating work simultaneously to achieve the energy saving.

    Brand Name : Haico

    Material : Stainless Steel

    Finishing : Polished

    Driven Type : Electric

    Power : 1-3kw

    Chiller Shape : Rectangular

    ...more
    Get Best Price
  • Benchtop PH Meter

    Benchtop PH Meter

    8,500 - 20,000 / Nos

    • Brand NameHaico
    • Availability1 Kg Approx
    • Country of OriginIndia
    • Temperature Accuracy+/- 0.5 Deg.
    • Calibration Points3 Or 5
    • mV Accuracy+/- 0.2 MV
    • pH Resolution0.001
    • HAICO pH meters can measure pH, mV, and temperature. A pH value indicates how much H+ has dissociated from molecules within a solution. A pH less than 7 indicates an acidic solution and a pH greater than 7 indicates a basic solution.   They use the latest microcontroller technology to provide the most accurate readings on the 3½ digit display. The instruments can be calibrated using up to 3 or 5 point calibration on the click of a key. They have the facility of auto buffer recognition. The calibration is retained in the memory even after the instrument is switched off thereby eliminating the need for frequent calibrations as in conventional instruments. The temperature compensation facility, both automatic and manual is available in model 101. The measurement range is from -2.00 to 20.00 pH with a resolution of 0.01 pH.   These are extremely useful instruments for agriculture and soil analysis laboratories, swimming pools, fertilizer plants, chemical industries, pharmaceutical industries, petroleum refineries, textile plants etc.   pH Make HAICO pH Range -2.000~20.000pH pH Accuracy 0.002pH pH Resolution 0.001, 0.01, 0.1pH ( Selectable) Calibration upto 5 points Calibration due reminder 1 to 30 days or Off pH Buffer options USA(pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45) DIN (pH1.09,4.65,6.79,9.23,12.7) OR User Define mV mV Range 1999mV mV Accuracy 0.2mV mV Resolution 0.1, 1mV ( Selectable ) Temperature Temp. Range 0~105, 32~212 Temp. Accuracy 0.5, 0.9 Temp. Compensation 0~100, 32~212, Automatic or Manual General Auto-Off Manual or Automatic (10, 20, 30 minutes after last key pressed (Selectable) Memory 500 readings with date & time Power Supply DC 5V adapters, using AC 220V / 50Hz, Dimensions LxWxH 210x188x60 mm Weight 1.2kg  
    ...more
  • Benchtop PH Meter

    Benchtop PH Meter

    8,500 - 20,000 / Nos

    1 Nos (MOQ)

    HAICO pH meters can measure pH, mV, and temperature. A pH value indicates how much H+ has dissociated from molecules within a solution. A pH less than 7 indicates an acidic solution and a pH greater than 7 indicates a basic solution.   They use the latest microcontroller technology to provide the most accurate readings on the 3½ digit display. The instruments can be calibrated using up to 3 or 5 point calibration on the click of a key. They have the facility of auto buffer recognition. The calibration is retained in the memory even after the instrument is switched off thereby eliminating the need for frequent calibrations as in conventional instruments. The temperature compensation facility, both automatic and manual is available in model 101. The measurement range is from -2.00 to 20.00 pH with a resolution of 0.01 pH.   These are extremely useful instruments for agriculture and soil analysis laboratories, swimming pools, fertilizer plants, chemical industries, pharmaceutical industries, petroleum refineries, textile plants etc.   pH Make HAICO pH Range -2.000~20.000pH pH Accuracy 0.002pH pH Resolution 0.001, 0.01, 0.1pH ( Selectable) Calibration upto 5 points Calibration due reminder 1 to 30 days or Off pH Buffer options USA(pH1.68,4.01,7.00,10.01,12.45), NIST (pH1.68,4.01,6.86,9.18,12.45) DIN (pH1.09,4.65,6.79,9.23,12.7) OR User Define mV mV Range 1999mV mV Accuracy 0.2mV mV Resolution 0.1, 1mV ( Selectable ) Temperature Temp. Range 0~105, 32~212 Temp. Accuracy 0.5, 0.9 Temp. Compensation 0~100, 32~212, Automatic or Manual General Auto-Off Manual or Automatic (10, 20, 30 minutes after last key pressed (Selectable) Memory 500 readings with date & time Power Supply DC 5V adapters, using AC 220V / 50Hz, Dimensions LxWxH 210x188x60 mm Weight 1.2kg  

    Brand Name : Haico

    Availability : 1 Kg Approx

    Country of Origin : India

    Temperature Accuracy : +/- 0.5 Deg.

    Calibration Points : 3 Or 5

    mV Accuracy : +/- 0.2 MV

    pH Resolution : 0.001

    ...more
    Get Best Price
  • ATex Approved Fixed Gas Leak Detect

    ATex Approved Fixed Gas Leak Detect

    50,000 - 100,000 / Piece

    • Brand NameHaico
    • MaterialAluminum
    • Power SourceBattery, Electric
    • ApplicationAmmonia Detecting, Combustible gas(CH4, LPG) CO H2S O2 NH3 CL2 H2 HCL NO N02 PH3 SO2 HCN ETO CLO2 HF F2 BR2 HCHO SF6 CO
    • FeatureWaterproof
    • Country of Origin220V
    • Number Of FlowerAmmonia Detector
    • Total Carbohydrate1year
    • Country of OriginIndia
    • SoundBeep
    • Fixed LED display hydrogen detector test H2 concentration by natural diffusion.It uses imported gas sensor from UK with very high sensitivity and accuracy,4-20mA analog signal output and RS485 digital signal output are optional. Special Features:-   ● High accuracy and sensitivity ● UK make impported Sensors ● LED digital display ● High & low alarm points ● DC24V power supply ● 4-20mA and RS485 optional● Water and dust proof ● Relay switch signal ● Aluminum shell material ● Industrial explosion-proof ● CE ,ATEX,ISO approved● One year warranty   Detected Gas Detection Range Resolution Low/High alarm point Detection Accuracy Combustible gas(CH4, LPG) 0-100%LEL 1%LEL 20/50%LEL ±5%FS CO 0-500/1000/2000PPM 1PPM 50/100PPM ±5%FS H2S 0-100/1000PPM 1PPM 10/20PPM ±5%FS O2 0-30%VOL 0.1%VOL 19/23%VOL ±5%FS NH3 0-100/500/5000PPM 1PPM 20/50PPM ±5%FS CL2 0-50PPM 0.1PPM 2/5PPM ±5%FS H2 0-1000PPM 1PPM 50/100PPM ±5%FS HCL 0-50PPM 0.1PPM 2/5PPM ±5%FS NO 0-250/2000PPM 1PPM 25/50PPM ±5%FS N02 0-20PPM 0.1PPM 5/10PPM ±5%FS PH3 0-20PPM 0.1PPM 1/5PPM ±5%FS SO2 0-20/50PPM 0.1PPM 2/5PPM ±5%FS HCN 0-50PPM 0.1PPM 5/10PPM ±5%FS ETO 0-100PPM 1PPM 10/20PPM ±5%FS CLO2 0-50PPM 0.1PPM 5/10PPM ±5%FS HF 0-10PPM 0.1PPM 5/10PPM ±5%FS F2 0-1PPM 0.1PPM 0.2/0.5PPM ±5%FS BR2 0-10PPM 0.1PPM 2/5PPM ±5%FS HCHO 0-10PPM 0.1PPM 0.5/1PPM ±5%FS SF6 0-1000PPM 1PPM 50/100PPM ±5%FS CO2 0-1/5/20/50/1000 0.1PPM 0.5/1PPM ±5%FS C6H6 0-100PPM 1PPM 20/50PPM ±5%FS VOC 0-100/1000/2000PPM 1PPM 20/50PPM ±5%FS Specification:Sensor Type: Electrochemical, Infrared, Semiconductor, PID Detection Gas: Toxic Gas, Oxygen Detection Range: 0-30%VOL; 0-NPPM Minimum Reading: 0.01%/0.1%VOL, 0.1/1/10PPM Indication Error: ±5%FS Sampling Mode: Diffusion Type Product Size: 215*205*80mm Product Weight: 1.6KG Power Supply: DC 24V Electrical Interface: G3/4 Explosion Proof: Ex d Ⅱ C T6 Gb Production Grade: IP66 Output signal: 4-20ma/RS485/Switching Value(optional) Alarm Mode: LED Display + Sound & Light Alarm Way to Install: Fixed Bracket/Tube Mounting/Wall Mounting Using the Environment: Humidity(0-95)%RH/Temperature -20℃-50℃Feature: 1. IP66 has a high level of protection against splashing.. 2. Adopting high precision sensor for accurate gas leak detection. 3. Real-time display of gas concentration, normal, fault, high & low alarm. 4. High accuracy sensor, strong interchangeability and high reliability. 5. Brightness LED display, English menu, easy to operate.
    ...more
  • ATex Approved Fixed Gas Leak Detect

    ATex Approved Fixed Gas Leak Detect

    50,000 - 100,000 / Piece

    1 Piece (MOQ)

    Fixed LED display hydrogen detector test H2 concentration by natural diffusion.It uses imported gas sensor from UK with very high sensitivity and accuracy,4-20mA analog signal output and RS485 digital signal output are optional. Special Features:-   ● High accuracy and sensitivity ● UK make impported Sensors ● LED digital display ● High & low alarm points ● DC24V power supply ● 4-20mA and RS485 optional● Water and dust proof ● Relay switch signal ● Aluminum shell material ● Industrial explosion-proof ● CE ,ATEX,ISO approved● One year warranty   Detected Gas Detection Range Resolution Low/High alarm point Detection Accuracy Combustible gas(CH4, LPG) 0-100%LEL 1%LEL 20/50%LEL ±5%FS CO 0-500/1000/2000PPM 1PPM 50/100PPM ±5%FS H2S 0-100/1000PPM 1PPM 10/20PPM ±5%FS O2 0-30%VOL 0.1%VOL 19/23%VOL ±5%FS NH3 0-100/500/5000PPM 1PPM 20/50PPM ±5%FS CL2 0-50PPM 0.1PPM 2/5PPM ±5%FS H2 0-1000PPM 1PPM 50/100PPM ±5%FS HCL 0-50PPM 0.1PPM 2/5PPM ±5%FS NO 0-250/2000PPM 1PPM 25/50PPM ±5%FS N02 0-20PPM 0.1PPM 5/10PPM ±5%FS PH3 0-20PPM 0.1PPM 1/5PPM ±5%FS SO2 0-20/50PPM 0.1PPM 2/5PPM ±5%FS HCN 0-50PPM 0.1PPM 5/10PPM ±5%FS ETO 0-100PPM 1PPM 10/20PPM ±5%FS CLO2 0-50PPM 0.1PPM 5/10PPM ±5%FS HF 0-10PPM 0.1PPM 5/10PPM ±5%FS F2 0-1PPM 0.1PPM 0.2/0.5PPM ±5%FS BR2 0-10PPM 0.1PPM 2/5PPM ±5%FS HCHO 0-10PPM 0.1PPM 0.5/1PPM ±5%FS SF6 0-1000PPM 1PPM 50/100PPM ±5%FS CO2 0-1/5/20/50/1000 0.1PPM 0.5/1PPM ±5%FS C6H6 0-100PPM 1PPM 20/50PPM ±5%FS VOC 0-100/1000/2000PPM 1PPM 20/50PPM ±5%FS Specification:Sensor Type: Electrochemical, Infrared, Semiconductor, PID Detection Gas: Toxic Gas, Oxygen Detection Range: 0-30%VOL; 0-NPPM Minimum Reading: 0.01%/0.1%VOL, 0.1/1/10PPM Indication Error: ±5%FS Sampling Mode: Diffusion Type Product Size: 215*205*80mm Product Weight: 1.6KG Power Supply: DC 24V Electrical Interface: G3/4 Explosion Proof: Ex d Ⅱ C T6 Gb Production Grade: IP66 Output signal: 4-20ma/RS485/Switching Value(optional) Alarm Mode: LED Display + Sound & Light Alarm Way to Install: Fixed Bracket/Tube Mounting/Wall Mounting Using the Environment: Humidity(0-95)%RH/Temperature -20℃-50℃Feature: 1. IP66 has a high level of protection against splashing.. 2. Adopting high precision sensor for accurate gas leak detection. 3. Real-time display of gas concentration, normal, fault, high & low alarm. 4. High accuracy sensor, strong interchangeability and high reliability. 5. Brightness LED display, English menu, easy to operate.

    Brand Name : Haico

    Material : Aluminum

    Power Source : Battery, Electric

    Application : Ammonia Detecting, Combustible gas(CH4, LPG) CO H2S O2 NH3 CL2 H2 HCL NO N02 PH3 SO2 HCN ETO CLO2 HF F2 BR2 HCHO SF6 CO

    Feature : Waterproof

    Country of Origin : 220V

    Number Of Flower : Ammonia Detector

    Total Carbohydrate : 1year

    Country of Origin : India

    Sound : Beep

    ...more
    Get Best Price

Be first to Rate

Rate This

Choose the service or product you're reviewing for this business

How would you rate the business?

What did you like and dislike?

  • Response
  • Delivery
  • Quality

Tell us about your experience?

About the Company

  • Primary Business Importer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers
  • Year of Establishment 2017
  • No. of Employees 6 - 20
  • Annual Turnover Below Rs. 0.5 Crore Approx.
  • Ownership Type Individual (Sole proprietorship)
  • GSTIN Number 27AQVPK9829L1ZP

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Hi-tech Engineers is Retailer of automatic smoke sensor, conductivity sensors, portable conductivity sensor, portable smoke sensor, safety smoke sensor, security smoke sensor, smoke sensors, toroidal conductivity sensor from Thane, Madhya Pradesh.
Read More »

Contact Information

Haico India

  • Sandesh Kesarkar
  • No. 403 - B, Devendra Apartment, Yashodhan Nagar, Lokmanya Nagar- 2, Thane, Maharashtra

Find Popular Conductivity Sensor Dealers

top