High Temperature Oil Bath Dealers in Udaipur

(1 products available)
  • CALsys -35/200 High Stability Bath

    CALsys -35/200 High Stability Bath

    225,000 / Piece

    • Resolution0.01°C
    • Volume6 Ltr
    • Power Requirement230 VAC, 2 KW (50 Hz)
    • Dimensions540(H) x 220(W) x 620(D)mm
    • Availability65 Kg
    • Temperature Range-35 to 200°C
    • Stability±0.01°C at -35°C, ±0.05°C at-0°C, ±0.04°C at 200°C
    • Uniformity±0.03°C at -35°C, ±0.06°C at 0°C, ±0.07°C at 200°C
    • Cooling Time60 min (room temperature to -35°C )
    • Access Opening105 (L) x 105 (W) mm
    • Immersion Depth150 mm
    • Method of controlDigital Self Tuned PID Controller
    • Computer InterfaceRS - 232
    • CalibrationAccredited calibration certificate provided
    • Environmental operating conditions0°C to 40°C, 0% to 90% RH (non-condensing)
    • Specifications valid in environmental conditions13°C … 25°C
    • Input (CaLsys -35/200 Autocal)Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C
    • CALsys -35/200 is a Highly Stable Stirred Liquid Bath for Calibration RTD / Thermocouple and also for compensation of cold junction.CALsys -35/200 offers the temperature range of -35 to 200°C. It has large tank which is filled with liquid (Water+Methanol/Silicon Oil). The liquid is heated or cooled to the desired temperature, where Methanol+Water are used for Negative Temperature and Silicon Oil is for Heating purpose.It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This CALsys -35/200 is built using CFC-free refrigerants.Key Features: High Accuracy High Stability and Uniformity Wide Temperature Range PC Interfacing Simple to Use and Cost-Effective AccessoriesStandard Accessories Reference Standard PRT…Part No.TPRT-A-300 NABL accredited calibration certificate - 3 point Software - Including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME. Operational Manual Optional Accessories Methanol............10 Ltr. No.(3050-M) Silicon Oil............10L Part No.C200S-LB SO   Input (CaLsys -35/200 Autocal): Four Channels (One master and three test sensors), high-quality LEMO connector suitable for both T/C and Rtd.Software (CaLsys -35/200 Autocal): The calibrator will be provided with software for data recording (Manual Mode) and report generation in Auto Mode.Data Logging (CaLsys -35/200 Autocal): Data Logging facility with logged data export to the computer through  LAN port (Optional USB)
    ...more