Input Module Dealers

(2 products available)
  • Addressable Input Module

    Addressable Input Module

    Get Price Quote

    • Availability155g (with Base), 85g (without Base)
    • Dimension / LWH108 mm x 86 mm x 38 mm
    • Humidity0 to 95% Relative Humidity, Non condensing
    • Indicator StatusNormal: Single blink / Active: Steady / Fault: Double Blink
    • Ingress Protection RatingIP30
    • Input RelayNormally Open dry contact
    • Input Resistance5.1Kohms / ¼ W
    • Material / ColourABS / White Glossy finishing
    • Operating Temperature-10°C to +50°C
    • Protocol / AddressingPrivate, Value range from 1 to 254
    • The PY-IM-101-A Addressable Input Module is used to acknowledge normally open monitor signals from interface equipment and then send a communication signal to the control panel, ideally for monitoring sprinkler system, pressure switch, position switch, signal valves, and other third party equipment such as conventional panel. The unit is manufactured based on the requirement of EN 54 part 18, European Standard. The unit is aesthetically pleasing with an unobtrusive design that will complement modern building designs and its plug-in type assembles make installation and maintenance more convenient to the installer. The unit incorporates an intelligent processor that provides automatic monitoring for both open and short circuits of the input signal line. The PY-IM-101-A Input Module is compatible with the PY-CP-4A Analogue Intelligent Fire Alarm Control Panel, produced by single manufacturer PEPL, to avoid addressable communication compatibility problems. Features Loop powered device LED status indicator Input cable monitored Normally open configuration
    ...more
  • Addressable Input Module

    Addressable Input Module

    Get Price Quote

    • MOQ100 Piece
    • Country of OriginIndia
    • Availability155g (with Base), 85g (without Base)
    • Current Consumption Standby0.6mA, Alarm: 1.0mA
    • Input Voltage24 VDC [16V to 28V]
    • Dimension / LWH108 mm x 86 mm x 38 mm
    • Humidity0 to 95% Relative Humidity, Non condensing
    • Indicator StatusNormal: Single blink / Active: Steady / Fault: Double Blink
    • Ingress Protection RatingIP30
    • Input RelayNormally Open dry contact
    • Input Resistance5.1Kohms / ¼ W
    • Material / ColourABS / White Glossy finishing
    • Operating Temperature-10°C to +50°C
    • Protocol / AddressingPrivate, Value range from 1 to 254
    • The PY-IM-101-A Addressable Input Module is used to acknowledge normally open monitor signals from interface equipment and then send a communication signal to the control panel, ideally for monitoring sprinkler system, pressure switch, position switch, signal valves, and other third party equipment such as conventional panel. The unit is manufactured based on the requirement of EN 54 part 18, European Standard. The unit is aesthetically pleasing with an unobtrusive design that will complement modern building designs and its plug-in type assembles make installation and maintenance more convenient to the installer. The unit incorporates an intelligent processor that provides automatic monitoring for both open and short circuits of the input signal line. The PY-IM-101-A Input Module is compatible with the PY-CP-4A Analogue Intelligent Fire Alarm Control Panel, produced by single manufacturer PEPL, to avoid addressable communication compatibility problems. Features Loop powered device LED status indicator Input cable monitored Normally open configuration Aesthetically pleasing design Fire or Supervisory signal configuration Built-in MCU processor and digital addressing Surface mounting with fix base for simple installation  
    ...more
Filter by Locality