  • Chns Analyzer

    Chns Analyzer

    5,490,000 / Piece

    • Brand NameAnalytical Technologies Limited
    • ConditionNew, Recycled
    • Country of OriginIndia
    • Model NoCHNS-3628
    • Instrument Range*Carbon:0.02 to 175 mg Carbon Hydrogen:0.1 to 12 mg Hydrogen Nitrogen:0.04 to 100 mg Nitrogen Sulfur: 0.01 to 20 mg Sulfur
    • Sulfur Analysis60-120 seconds
    • Readability0.0001%
    • Analysis Time4.5 minutes
    • FurnaceResistance furnace; both primary and afterburner; up to 1100oC
    • Autoloader30-position (stackable to 120 samples)
    • Dimensions32 in. H x 27.5 in. W x 30 in. D (81 x 70 x 76 cm)
    • Weight (approx.)273 lb. (124 kg) Shipping Weight (approx.): 324 lb. (147 kg)
    • Technical Specification      Unique combustion gas handling and aliquot dosing system significantly extends the lifetime of the reagents used, lowering cost-per-analysis and instrument downtime, while eliminating the need for chromatographic separation techniques and other costly whole gas analyses. Simple, gravity-fed autoloader allows for unattended analysis, while increasing long-term reliability of loader. Independent detectors used for simultaneous elemental determination, resulting in rapid analysis times.     Features      Dual-stage furnace system operates at temperatures up to 1050°C with pure oxygen to ensure the complete combustion of all organic samples, without requiring additional metal oxidizing reagents or other carrier gases • Quartz lance directs oxygen flow directly onto the sample, accelerating the combustion process and providing superior recovery • Large, porous crucible aids combustion process and extends maintenance intervals
    ...more
  • Fiber Analyzer

    Fiber Analyzer

    Get Price Quote

    FA3600 Fiber Analyzer is an analysis instrument used to test the crude fiber content of samples through acidic or alkaline hydrolysis, flushing and filter process. FA3600 functions include automatic solution adding, automatic pre-heating and so on. Infrared tube heating is used, and high-precision soak extraction and filter ensure test precision: high-definition color LCD screen displays temperature and time. Advanced infrared heating manner gives high heating efficiency and excellent control property; U.S imported filter pump boasts high acid/alkali resistance, good stability and long service life; High-precision acid/alkali filter device maintains samples in good condition; Three pre-heating routes of acid/alkali distilled water can be controlled separately, and digestion Heating is under separate control, easy for setting adjustment; Reagent pre-heating, adding, sample filtration, back flushing and other functions are all under electric and automatic control; Six samples can be dealt with at the same time, and sample digestion time can be set freely; Stable, rapid and safe automatic filtration back-flushing effectively prevents sample blockage; 5.7” high-definition color LCD screen displays current test status; intelligent HMI is available. FA3600 Fiber Analyzer is applicable for the test of crude fiber contents of plants, feed, foods and other agricultural products. and testing detergent fibers, cellulose, semi-cellulose, lignin and other relevant parameters.     
    ...more
  • Oxygen Analyzer

    Oxygen Analyzer

    Get Price Quote

    Based on our own proprietary Diode Laser Absorption Spectroscopy (DLAS)technology, LGA-2000 Laser Gas Analyzer is capable of continuous on-the-spot gas concentration measurement and monitoring. It Demonstrates the characteristics of in situ detection in lieu of sampling, high measurement precision, short Response time, easy installation and maintenance, and etc. Application fields: Metallurgy, Petrochemical industry, biochemical pharmaceutics, environmental protection and Waste management, aeronautics and astronautics and other situations where gas analysis are needed
    ...more
  • PH 2-wire Transmitter MODEL 873

    PH 2-wire Transmitter MODEL 873

    Get Price Quote

    Pantech Instrumentâs 2-wire Transmitters, Model 873, are designed to provide 4-20 mA DC signal on the same two wires which carry the 24 V DC power for measurement of pH. The transmitter is an ideal choice for on line pH measurement using any industry standard combined gas electrode. It provides a current output signal capable of driving load upto 650 ohms. This allows pH measurement at a distant place from the control room all the time. The temperature compensation is built in and the process temperature is measured by RTD. The compensation is provided over the complete range of 0-100 deg. C. The instrument can be calibrated throughout the range of 0-14 pH with a minimum span of 2 pH. The transmitter is available in field mounted housings with or without local digital display
    ...more
  • Oxygen Analyzer

    Oxygen Analyzer

    Get Price Quote

    Oxygen Analyzer, Clinical Testing Services, Analytical Training Service