Water Softener Plant
Get Price Quote
We are offering water softener plant
section - 5
technical specifications of water softening
plant - qty – 1
basic data of water quality report & requirements:
- raw water hardness 2000 ppm approx.
- soft water quality after first pass up to 200 ppm
- soft water quality after second pass up to 10 ppm
- output required per regeneration 60 m3
- no. Of regenerations in 4 days one
- consumption water quantity 60 m3 in 4 days
1 centrifugal water pump
sr.
No. Description
uom specification
1.1 quantity 1
1.2 capacity lph 8000
1.3 discharge pressure kg/cm2 3
1.4 make of pump cri /cg/kirloskar
1.5 power hp 1.5
1.6 flow capacity
m3 /hr
max.: 12
min.: 7.5
1.7
working pressure
kg./cm2
max: 3.5
min: 2.5
1.8 type of drive iii phase, 415 v ac, 50 hz
1.9 purpose
to transfer the raw water at required pressure
to primary softening plant.
2 primary pass water softener
2.1 plant details
2.1.1
feed raw water
hardness
ppm 2000
2.1.2
product water quality
at outlet
ppm 200
2.1.5 regeneration interval days 4
2.1.6 time of regeneration hour 1.5 approx.
2.2 softener vessel data
2.2.1
salt required per
regeneration cycle
kg. 350
2.2.2 dia. Of vessel mm 1400
2.2.3 height of vessel mm 2500
22
2.2.4
material of
construction
m.s.rl / m.s.frp
2.2.5 shell thickness mm 6
2.2.6 frontal piping size mm 40
2.2.7 moc of pipe upvc
2.2.8 types of valve multiport valve
2.2.9 size of valve inch. 1.5
2.2.10 make of valve initiative / midas
2.2.11 method of injection venturi type ejector
2.2.12 material of injector pp valve
2.3 resin
2.3.1 type strong acid cation
2.3.2 make ion exchange india ltd / thermax
2.3.3 quantity ltrs. 2500
2.4 brine tank
2.4.1 qty. No. 1
2.4.2 size ltr 2000
2.4.3 type & make hdpe
2.5 sampling cock
2.5.1 size mm 15
2.5.2 material brass/upvc
2.6 plant accessories
2.6.1 inlet valve qty. Nos. 3
2.6.2 moc of valve upvc / brass
2.6.2 by pass mechanism provide
2.6.3
pressure gauge qty./
range/size
no. 2 / 0 kg to 10 kg / 4 inch
2.6.4 pressure gauge make air master/pointer
2.6.5 pipe & fittings upvc
2.6.6 pipe make supreme / astral (30 ft)
2.6.7 test kit qty. No. 1
2.6.8 test kit make prerna / filtra
23
3 secondary pass water softner
3.1 plant details
3.1.1
feed water hardness
to second pass
ppm 200
3.1.2
product water quality
at outlet
ppm less than 5
3.1.5 regeneration interval days 4
3.1.6 time of regeneration hour 1
3.2 softener vessel data
3.2.1
salt required per
regeneration cycle
kgs 63
3.2.2 dia. Of vessel mm 600
3.2.3 height of vessel mm 1800
3.2.4 type of vessel vertical
3.4.5 vessel make pentair
3.4.6
material of
construction
frp
3.4.8 frontal piping size mm 40
3.4.9 moc pipe upvc
3.4.10 types of valve multiport valve
3.4.11 size of valve inch 1.5
3.4.12 make of valve initiative / midas
3.4.13 method of injection venturi type ejector
3.4.14 material of injector ciel
3.5 resin
3.5.1 type strong acid cation
3.5.2 make ion exchange india ltd/thermax
3.5.3 quantity ltrs 450
3.6 brine tank
3.6.1 qty. No. 1
3.6.2 size ltr 120
3.6.3 type & make hdpe
24
3.6 plant accessories
3.6.1 inlet valve qty. Nos. 3
3.6.2 moc of valve upvc / brass
3.6.3 by pass mechanism provide
3.6.4
pressure gauge qty./
range/size
no. 2 / 0 kg to 10 kg / 4 inch
3.6.5 pressure gauge make air master/pointer
3.6.6 pipe & fittings upvc (20 ft)
3.6.7 pipe make supreme / astral (30 ft)
3.7 flow meter
3.7.1 flow meter qty. Nos. 1
3.7.2 flow range 50 lpm to 133 lpm
3.7.3 accuracy +/- 2% for f.s.d
3.7.4 display 7 digital lcd
3.7.5 mounting on line type vertical or horizontal
3.7.6 installation solventable t or clamp on saddle
3.7.7 power supply 220v ac
3.7.8 operating pressure kg/cm2 5
3.7.9 operating temp. C° 15 to 55
3.7.10 moc p.p. Sensor, abs enclosure
3.7.11 standard fitting size mm 15
3.7.12 make jlc international/universal flow monitors/mts
4 exclusion if any
4.1 all types of civil works by gaic
4.2
all types of electric
works
by gaic
...more