Air Cooled Condenser
3,500 Per Piece
1 Piece (MOQ)
BMW Car AC Compressor
19,500 - 21,500 Per Piece
1 Piece (MOQ)
Best Deals from AIR Conditioning System
HVAC Duct System
25,000 Per Piece
Fan Filter Unit
36,000 - 45,000 Per piece
1 piece (MOQ)
Multipurpose Cold Storage Room
200,000 Per Piece
1 Piece (MOQ)
evaporative cooling unit
150,000 Per Piece
1 Piece(s) (MOQ)
Blue Star Cassette Air Conditioner
Get Price Quote
1 Piece (MOQ)
AIR OPERATED FRL UNIT
Get Price Quote
Chiller Plant
Get Price Quote
NEER CORN TECHNOLOGY is the leading Manufacturer of Chiller Plant in New Delhi India. Our assorted range of chillers are used for chilling applications such as machine and oil cooling, chemical and pharmaceutical processes cooling, comfort cooling, process water-cooling etc. These environmental friendly refrigeration systems are efficiently designed to offer maximum chilling and can also be customized as per the requirements.
Milk Chilling Plant
1,000,000 Per Piece
1 Piece (MOQ)
Air Handling Unit
50,000 - 100,000 Per piece
10 Piece (MOQ)
Chilling Plant
Get Price Quote
We offer a wide range of refrigeration, air conditioning and ventilation systems, which are available in different specifications and dimensions. These are offered at industry leading prices and can also be customized as per the specific requirement of our customers.Salient Features: Compact Design Fully Automatic High Efficiency Condenser Air/water Cooled Condenser Thermostatic Exp. Device Automatic Temperature Controller Indranil Chilling Plant is being manufactured from 3 TR to 200 TR capacity in compact design covering minimum floor area. Our Chilling plants have different features as below: Indranil Packaged Type Chilling Plants are carefully designed for optimum performance, long life and easy serviceability. Painstaking engineering goes into the design, selection of materials, manufacturing process, assembling and testing to ensure correct control performance, equipment design in compact and uncluttered, with every part easily accessible for servicing. Low Operating Cost - Scientifically designed cooling system combined with high efficiency condenser, chiller, compressor, expansion valve provide more efficient water cooling with consequent reduction in operating cost. Low Maintenance Cost - Quality that minimizes the maintenance. Motor requires lubrication very often. In case when you require maintenance our nearby service engineers are always eager to attend maintenance problem. Single source responsibility covering designing, manufacturing, installation and servicing by our experienced engineers, always standing by to attend post installation problems
Samsung VRF Dvms System
30,000 - 80,000 Per Piece
1 Piece (MOQ)
Air Curtain
Get Price Quote
An air door or air curtain is a device used for separating two spaces from each other, usually at the exterior entrance. The most common configuration for air curtains is a downward-facing blower fan mounted over an opening, blowing air across the surface of the opening. Air Curtains can come with, or without heaters to heat the air. Normally the opening is an entrance to a building, or opening between two space conditioned at difference temperatures. Air curtains can serve many purposes. They can be intended to help keep flying insects out by creating forceful turbulence. It also helps keep out outside air, reducing infiltration though the opening. They can also be used to avoid cold drafts by mixing in warm air heated by the air curtain. The fan must be powerful enough to generate a jet of air that can reach the floor. Air curtains are utilized when a barrier is needed across an opening, and when reducing energy costs is desired. Some applications include customer entryways, airplane hangars, cargo doors, drive through windows, restaurant doors, or shipping receiving doors. The air stream the air curtain places across the opening creates an invisible barrier to contain an air conditioned space and reduce infiltration. Typically, an air curtain can pay for itself in one to two years by reducing the load on the building's heating or air conditioning system. Usually, there is a mechanism, such as a door switch, to turn the unit on and off as the door opens and closes, so the Air Curtain only operates when the door is open. Heated Air curtains are commonly used when supplemental heat is needed for a space, and to reduce the wind chill factor across the opening in colder climates. Air Curtains work best when the pressure differential between the inside and outside of the building is as close to neutral as possible. Negative pressures, extreme temperature differences, elevators in close proximity, or extreme humidity can reduce the effectiveness of Air Curtains. The most effective air curtain for containing heated or cooled air inside a building with an open door will have a high face velocity at the opening, generated by top-down flow, recovered by a recirculating air plenum and duct return to the source fans. This configuration is available for new construction, but difficult to provide in existing buildings. The air curtain is most effective with low exterior wind velocity. At higher wind velocities, the rate of air mixing increases and the outside air portion of the total face flow increases. Under ideal conditions of zero wind, the effectiveness of the air curtain is at its maximum. In windy locations air curtains cannot create a perfect seal, but are often used to reduce the amount of infiltration from an opening. For industrial conditions, high face velocities are acceptable. For commercial applications like store entrances, user comfort dictates low face velocities, which reduce effectiveness of separation of exterior air from interior air. Non-heated air curtains are often used in conjunction with cold storage and refrigerated rooms. Airflow through a door depends on wind forces, temperature differences (convection), and pressure differences. Air curtains can be used to save energy by reducing the heat transfer (via mass transfer when air mixes across the threshold) between two spaces, although a closed and well-sealed physical door is much more effective. A combination is often utilized; when the door is opened the air curtain turns on, minimizing air flow from inside to outside and vice versa. Air curtains are often used where doors are required to stay open for operational purposes, such as at loading docks and vehicle entrances.
Water Chiller
55,000 - 450,000 Per Pieces
1 Pieces (MOQ)
Condenser Straight Shape
300 - 320 Per piece
YOU ARE A QUALITY IS VERY GOOD Condenser Straight Shape
Cold Room Cabinet
Get Price Quote
1 Piece (MOQ)
display primary: 14 segment amber secondary: 7 segment greenicons : 10keypad8 x touch keydata logginginbuilt data logging via sd card & flash memoryreal time clock (rtc)presentserial outputrs485 modbus (2 no's)probe inputsroom temp, coil temp, haccp temp, humidity.digital inputhp, lp, sppr, aux1, aux2, r-phase, y-phase, b-phase.potential free: doordigital outputcompressor, evaporator, condenser, defrost, lsv, light, alarm, humidifier, buzzer.buzzeryespower supply415v ±10% 50-60hz (crosscheck) temperature range-50°c to +50°c (crosscheck) main switch general protection 4 pole mcb lvm 4 wire voltage monitoring & protection size(h) 400 x (w) 300 x (d) 135mm (please cross check) mounting typewall mount haccp haccp desktop monitoring presentsms alert systemcomplaint through iot box cloud based data monitoring applicationcold room control panel
water chiller unit
98,000 Per
1 Piece (MOQ)
Aroma Electric Diffuser
Get Price Quote
2000 Pieces (MOQ)
The aesthetic collection of Aromatic Electric Diffuser, made available by us, has gain recognition in wide commercial and residential areas in India. Our company has marked its presence in the market as the most distinguished Manufacturer and Supplier of Aroma Electric Diffuser. We make available Aromatic Electric Diffuser in attractive designs, shapes and sizes. We are committed to deliver Electric Aroma Diffuser at the best prices.
Laboratory Chiller
Get Price Quote
honeycomb dehumidifier
Get Price Quote
1 piece (MOQ)
Industrial Dampers
Get Price Quote
Basically classified into 3 types : Volume Control Dampers Fire Dampers Gear Dampers Applications: Dampers are devices incorporated into the system to have a proper control on airflow for better maintenance of conditions and better uniformity. Construction and Supports: Dampers are generally of galvanized iron make or anodized aluminium make. In order to avoid any leakage from the damper, it is provided with overlapping leafs, which can also be incorporated with compression and stop seals for more critical zones. In case of gear dampers, a specialized, lubricated gear mechanism is provided for easy and precision control. In case of fire damper, a fusible link along with a gear mechanism is provided, which shuts down the flow of air from one room to another during a fire hazard. Sizes: Tailor made, as per the requirement of the design.
High Flow Humidifier
160,000 - 255,000 Per Piece
15 Piece (MOQ)
Operation Transport and Storage Temperature: 18C to 28C (64.4 F to 82.4 ??F) -25C to +70C (-13 ??F to +158 F) Humidity: 93%, Non-condensing 93%, Non-condensing Atmospheric Pressure: 760 hPa to 1060 hPa 760 hPa to 1060 hPa Heated humidification Range: Off, 1 - 5 gear Humidifier Output: No less than 33 mg/L, at 37 C target Maximum Delivered Gas Temperature: 43C Mode of Operation Continuous Work Mode HFlow, LFlow, AutoFlow, SmartFlow SD Card SD card can record patient data and fault information AC Power Consumption 220 V - 240 V ~, 50 Hz / 60 Hz, 2.5 A Type of Protection against Electric Shock Class II Equipment Degree of Protection against Electric Shock Type BF Applied Part Degree of Protection against Ingress of Water IP22 Sound Power Level < 28 dB (A), When the working mode of the device is HFlow, and the output flow is 25 L/min Maximum oxygen input flow 80 L/min FiO2 Range: 21% -100 %, binning interval 1% Margin of Error: +(5% + 5% set value) FiO2 Display Accuracy +(5% + 5% set value) Temp Range: 25C -45C Temp Display Accuracy +2C Flow Range: 2 L/min -80 L/min Margin of Error: +(2 L + 10% set value) Flow Display Accuracy +(2 L + 10% set value) sPEEP Range: 0 ~ 20 hPa Margin of Error: +(1 hPa + 20% set value) Humidity Compensation Range: -3-3,-3-2-1 0 -1-2-3, the higher the range, the higher the humidification output Flow Step Interval Range: 15 L/min -80 L/min Tube Length: 1.8 m Margin of Error: +10% The connection should not fall off under the 45 N tension. Specification of Patient Connector 18 mm cone joint
Hot Water Generator
Get Price Quote
We are chiefly engaged in the manufacturing, exporting, and supplying of Hot Water Generator all over the world. The Hot Water Generator, offered by us, is designed as per the set industrial quality standards. Our Hot Water Generator is high in performance and working life, and thus demanded by national and international clients. Our Hot Water Generator is provided at the most competitive prices. Acclaimed For Higher efficiency Long working life Lesser maintenance Easy installation
power bus ducts
Get Price Quote
Bus duct design are most important as bus duct have much less volume of air dissipation compared to PCC. Bus duct is an important link to feed power from transformer. LT side to the PCC incomer. Material used are high grade electrolytic copper or aluminum and also bimetals, if required. IP Class as per the client requirements.Details : Busduct up to 4000A with Cu/Al busbars supported on DMC/SMC support. Bus bars with heat shrinkable sleeves with color codes. Indoor/Outdoor duty, separate adapted earthling at both ends with space heaters and earth bus.
Aluminium Rectangular Duct
Get Price Quote
50 Square Feet (MOQ)
Industrial Air Washer Unit
100,000 Per Piece
1 Piece (MOQ)
An air washer is a piece of equipment that is designed to improve air quality by scrubbing the air that moves through it and adjusting humidity levels to keep the environment consistent. Air washers are used as part of climate control and air quality systems . Industrial Air Washer Unit Washer and that works on the principle of cooling outside air by passing it over water-saturated pads, causing the water to evaporate into it. The cool air is then directed into the required space, and pushes warmer air out through the given vents. Air Washer Unit is a very energy-efficient means of cooling. These washers have long working life and are available in modular designs. Advantages of Air Washer. Low installation cost, Low running/operation cost Effective in high heat generation areas Easy 8. inexpensive maintenance Healthier System – Since it works on 100% fresh air
Delfield Blast Chiller
Get Price Quote
1 Piece (MOQ)
Hot Water Generator
60 Per Litre
We are counted amid the quality-centric organizations and thus source the inputs only from the trustworthy sources. Also, these raw materials are checked against varied quality parameters. Want to obtain Hot Water Generator at market's lowest prices? Deal with us. We are famous supplier of Hot Water Generator Product Details: Design, Erection & Commissioning of Hot Water Generator using briquette as fuel replacing LDO, HSD & FO It’s basic way of operation is same as TFH & lining of equipment is also same as TFH only pressurized unit gets added Water in pressurized form is circulated through equipment & then it is heated up to 140 Deg. C (Optimum temperature which can be achieved) which is supplied to application site To preheat the water, provision of WPH is provided so that water can be utilized for any other process Gas purification unit is mounted between WPH and I.D. This adjustment is done if required according to PCB norms Note : Change in temperature can be done according to client’s requirement but optimum limit is 140 deg. CAdvantage of Hot Water Generator: Water with high temp can be achieved Economically viable plant
Chilling Plants
Get Price Quote
1 Piece(s) (MOQ)
We are offering Chilling Plants. we are given prime importance to customers satisfaction in giving quality and meeting their requirement in totality. covering a wide range capacities upto 120 trs (in either or ammonia as refrigerant) to cater the requirement of application as enlisted below application : chemicals, comfort cooling, diamond industry, dyeing / bleaching industry, edm machine cooling, food products : milk & dairy, pasteurizing, induction heat treatment. lighting, lubricant / oil cooling, mineral water / soda process, paper and pulp processing, plating and anodizing, plastic process : blow molding, injection molding, extruders, pvc pipes, pp film lamination, woven sacks, plastic and rubber calendars, pharmaceuticals, printing ink/ paper waxing cooling, vacuum metalizing in case, you regularly require specific models to suit to your requirement, we can certainly work out for such arrangement with compact chillers, which may turn to be economical, power saving, maintenance free, user friendly, noiseless and better in performance.