Mov Circuit Breaker
Get Price Quote
Mov Circuit Breaker offered is designed and developed using latest technology support and finds suitability for installation in lightning protection partition as well as for RS422 communication protocol used for surge protection of signal lines. Some of the areas these are used in include low voltage general electricity cabinet, outdoor electricity cabinet and others. Its features include as modular power surge protector is designed as per industry standards, applicable for 220/380V power distribution system, suitable for lightning protection in all classes, provides for convenient connection support, working as fast acting fuse for protection of semiconductor device. Specifications: Molded case circuit breaker with magnetic trip setting 360A.550A,850A,1050A Fast acting fuse for protection of semiconductor device 800A,1000A,1250A,1500A MOV 575V, 660V Current limiting reactor (CLR) suitable for any size of power DI/DT Reactor High Frequency Transformer (HFT) Resistor of any ohm value and wattage Capacitor for snubber circuit and dc power supply Dc power supply assembly Potential transformer, control transformer, current transformer Temperature switch, temperature sensor, pressure switch, flow switch, pressure gauge,temperature gauge
Gear
Get Price Quote
A gear is toothed tube shape or roller shape part of a machine which network with another toothed tube shaped to transmit control frame from one shaft to another. It is mostly used a speed driving gear and highly depends upon which type of gear you are selecting.Shree Shakti Engineering work is a pioneer company in manufacturing, supplying and exporting a wide range of Gear. These offered Gears are fabricated utilizing high-grade crude materials by our talented expert’s incongruity with international quality standards. The offered gears are accessible in different sizes, shapes and can be additionally done according to the particular prerequisites of customers. Before being to dispatch it to the clients this Gears undergoes astrict quality test for ensuring the flawlessness. Further, it is available at pocket –friendly rates. The different type of the gear manufacture by Shree Shakti Engineering works are Worm wheel & shaft Gear shaft Big size Gear Helical Gear Features of Gea: Easy to manufacture High strength Accurate dimensions Corrosion resistance
Best Deals from Circuit Breaker
DC MCB
500 Per Piece
Contact Breaker
Get Price Quote
Switch Gears
Get Price Quote
MCB’s (Miniature Circuit Brackers) and RCCB’s (Residual Current Circuit Breaker) host of control are used in power distribution systems for protection devices against excess load and short circuit fault and different types of Distribution Boards. These products are widely used in Residential, Commercial sectors and Industrial area.
ABB TA42DU-42 Thermal Overload Relay
3,000 Per Piece
10 Piece (MOQ)
Auto Mechanical Changeover Switches
10,000 Per Piece
1 Piece (MOQ)
Automatic Changeover System
Get Price Quote
In order to have uninterrupted chlorine gas supply to chlorination system necessary manifolds.Motorised valves and control panel are provided. Chlorine tonner are connected to manifold in which pressure gauge and pressure switch are installed. Pressure gauge indicates the chlorine tonner pressure and pressure switch actuate the electrically operated ball valve. Pressure switch is set at 1.0 kg/cm² that means chlorine cylinder is getting empty.Filled tonner connected to manifold. All tonners valve are kept opened so that manifolds are under pressurized condition. Switch on the auto change over panel and keep the selector switch in auto mode now as soon as panel is energized electrically operated valve manifold –I will open first. Even though manifold –ll is pressurized ,manifold –ll side valve will not operate due to inter lock system.As plant is in operation, chlorine gas will be consumed and tonner pressure may be coming down.When pressure switch actuator and alarm will come and electrically operated ball valve on manifold –l will close and valve on manifold – ll will open simultaneously. This system will be in operation till chlorine gas pressure is above 1.0 kg/cm² at the manifold. During this period fresh filled cylinders may be connected to manifold and kept ready for operation. As explained earlier, chlorine pressure started going below 1.0 kg/cm², alarm will be there and manifold –l valve in opened thus the operation of auto change over system continues.Note :- Kindly note that when the manifold pressure is 1.0 kg/cm² the chlorine tonner is not fully empty there will be at least one or two kg of chlorine will be available. It is not advisable to send chlorine cylinders for refilling with so much of chlorine left over. This left over chlorine shall be exhausted by keeping auto/manual selector switch in manual mode and operate corresponding push button stations and electrically operated valve can be opened. Keep the valve in open position till chlorine pressure comes to 0.2 kg/cm² . pressing “off” push button, valve will be closed. Similar way manifold –ll side shall be operated. During this operation no need of opening bypass valves. During manifold-ll is in operation fresh filled tonner may be connected to manifold –l and kept ready for auto operation.
ESE Lightning Arrester
Get Price Quote
POE switch
Get Price Quote
100 Piece (MOQ)
Lightning Protector
Get Price Quote
We are instrumental in offering the exceptional assortment of product that are deigned and manufactured only after complete examination of the raw materials and inputs used. We make use of premium material for packaging the offered lot so as to ensure safe side deliveries.
Domestic Electronic Auto Phase Changer
Get Price Quote
Details : Fully Automatic Healthy Phase indicator facility Overload and Short circuit protection is provided through MCB Inbuilt heavy duty relay to avoid short Circuit Application : Only used for Office and Shop Used in Residency
Automatic phase changer
Get Price Quote
Capable to shift and re-shift the load from one phase to another phase automaticallywhen load increases on any phase.No manual work required.Over Load & Short Circuit Protection is provided through MCB.Healthy Phase Indicator facilityFacility of Cut-off to avoid fluctuation of low voltage.Inbuilt heavy duty relay to avoid short circuit
electrical mcb switch
625 Per Piece
Rocker Switches
10 Per Piece
Gear
Get Price Quote
We are one of the renowned manufacturers and suppliers of a comprehensive range of Double Drive Gear Box Equipment
Digital Single Phase Earth Leakage Circuit Breaker
Get Price Quote
Facility: Fully microcontroller based technology, 7 segment display for displaying voltage, ampere and leakage ampere (1-32 m.a.) LED indication for operation status, Adjustable leakage current setting (1-32 m.a.), High voltage protection above 290, Low voltage protection below 130, Inbuilt auto restart facility after resuming power supply, (90 second) Auto-bypass facility, Protection against absence of phase or neutral, High accuracy & long life durability, Powder coated metal body, Included 32 amp ISI marked branded MCB, Electronic over load protection(1-32 amp. SETABLE),
PVC MCB Box
12 Per Piece
400 Piece (MOQ)
Air Circuit Breakers
Get Price Quote
Automatic Transfer Switch Panel
Get Price Quote
We are manufacturing complete range of special panel as follow. Testing Panel. Rotogravure/Flexo Printing Machines Lamination Plants Slitting & Rewinding Machines for Paper, Foil, Metal Etc. Wire Drawing Re-rolling. Tube Mill Plant Textile Processing Machines. Packing Machines Seweage Treatment Plant.
Switch Gear
Get Price Quote
PVC MCB Box
10 - 25 Per Piece
100 Pack (MOQ)
switch gear components
Get Price Quote
High Voltage Electrical Isolator
10,000 Per unit
1 unit (MOQ)
Single Phase Changer
2,500 Per Piece
25 Piece (MOQ)
Remote Control Switch
1,000 - 5,000 Per Piece
Earth-leakage circuit breaker
Get Price Quote
Features Capacity : 20A/32A/63A (1, 3) Sensitivity : 3-30ma (1/3-100mA (3) (adjustable) Protection : Electric shock/ Earth leakage/ Short circuit/ Over load protection/ High voltage cutoff/ Siren (Optional)
Tripping Coil
2,500 Per Piece
1 Piece (MOQ)
Moulded Case Circuit Breaker
Get Price Quote
Molded case circuit breakers are a type of electrical protection device that is commonly used when load currents exceed the capabilities of miniature circuit breakers. They are also used in applications of any current rating that require adjustable trip settings, which are not available in plug-in circuit breakers and MCBs. BeSwitch molded case circuit breakers are used to provide circuit protection in alternative energy, commercial, industrial, mining, and military applications, where they protect against overloads and short circuits in conductors. These circuit breakers are applied in panelboards, switchboards, motor control centers, control panels, combination starters, individual enclosures, and bus duct plug-in units.
lightning protection material
Get Price Quote
Lightning Protection Materials are used to protect a building or facility from the devastating effect of lightening, electrical short circuits, leakage currents & the after effects. A lightning strike carries with it, electric potential in thousands of volts, which could destroy any structure & people within. If not grounded properly, the massive surge of electric power will damage the building, costly equipments within and people. Earthing & Lightning Protection Materials, which are made of high quality copper and copper alloys acts, when installed on the building as carriers of this high potential to the ground. Lightning Arresters are installed on the top of a building, in combination with down conductors, clips and earthing system. This provides a least resistant path for the electric energy to flow to ground, where earthing system takes it to deep within. In addition to grounding the lightening energy, the electrical short circuits and leakage currents are also earthed or grounded using these equipments.