Dry Heat Sterilizer Dealers in Naroda, Ahmedabad

(4 products available)
  • Dry Heat Sterilizer

    Dry Heat Sterilizer

    Get Price Quote

    • Insulation Wall: 125mm (t) Mineral Wool. A grade mineral wool insulation to optimize heat effectiveness and stop heat loses.
    • Finishing: All stainless steel components buffed to matt finish.
    • Insulation Wall: 125mm (t) Mineral Wool. A grade mineral wool insulation to optimize heat effectiveness and stop heat loses.
    • Finishing: All stainless steel components buffed to matt finish.
    • Temperature: Up to 250°C
    • Material of Construction: Interiors with 14 gauge S.S. 316 quality sheets. Exteriors with 16 gauge S.S. 304 Quality sheet. Frame work of Rolled steel sections 6, 5 & 3mm. the interior frame work of S.S 316 quality
    • Trolley: Fabricated from AISI SS 316 Quality angles & flats with ‘U’-Grooved Stainless Steel wheels.
    • Transfer trolley: Fabricated from S.S. 304 Quality Angles & flats with castor wheel for sterile & Non-sterile room.
    • Doors: Two Doors, one opening into the sterile room and the other into the Non-sterile room. The doors are lined with silicon rubber for sealing. The door in the sterile room is claded with 16 gauge AISI SS 304 sheet.
    • Interlocking: To maintain the barrier between the sterile and non-sterile room, both the doors are pneumatically interlocked. The pneumatic system consists of pneumatic Cylinders, solenoid valves and flow control valves.
    • Air recirculation: A 2 H.P. 1440-RPM motor drives the impeller. Air enters the Chamber through perforations provided passes horizontally over the charge and is re-circulated.
    • HEPA Filter Module: Air entering the system is passed through a HEPA Filter Module consisting of a pre-filter up to 5 microns, a blower & a HEPA Filter up to 0.3 microns. The filtered air is fed to the impeller for circulating in the system.
    • Temperature Control & Timer: A combined Electronic Digital Controller & Timer is installed. ±2ºC., one probe centrally mounted.
    • Scanner: A six point Digital Scanner is incorporated, with facility of Hold & Scan at all six points.
    • Temperature Recorder: A, 1 point Circular Chart recorder is installed with chart Dia. 8”
    • Cooling Coils: Crimped Finned Tubes with headers, S.S. 304 Quality to speed up cooling cycle.
    • Panel Board: Consists of: Ammeters, Voltmeter, Voltmeter switch, HRC fuses & Circular chart Recorder
    • Control panel: Motor Starter, Contactors, Rotary Switches, Indicating lights for heating & Cooling cycle and phase indicating lights.
    • Exhaust damper: Controlled by solenoid valve and is opened during the initial heat-up, shuts off and re-opens during cooling cycle.
    • Fan: Dynamically balanced fan provided for hot air circulation to achieve uniform temperature
    • Temperature: Up to 250°C
    • Material of Construction: Interiors with 14 gauge S.S. 316 quality sheets. Exteriors with 16 gauge S.S. 304 Quality sheet. Frame work of Rolled steel sections 6, 5 & 3mm. the interior frame work of S.S 316 quality
    • Trolley: Fabricated from AISI SS 316 Quality angles & flats with ‘U’-Grooved Stainless Steel wheels.
    • Transfer trolley: Fabricated from S.S. 304 Quality Angles & flats with castor wheel for sterile & Non-sterile room.
    • Doors: Two Doors, one opening into the sterile room and the other into the Non-sterile room. The doors are lined with silicon rubber for sealing. The door in the sterile room is claded with 16 gauge AISI SS 304 sheet.
    • Interlocking: To maintain the barrier between the sterile and non-sterile room, both the doors are pneumatically interlocked. The pneumatic system consists of pneumatic Cylinders, solenoid valves and flow control valves.
    • Air recirculation: A 2 H.P. 1440-RPM motor drives the impeller. Air enters the Chamber through perforations provided passes horizontally over the charge and is re-circulated.
    • HEPA Filter Module: Air entering the system is passed through a HEPA Filter Module consisting of a pre-filter up to 5 microns, a blower & a HEPA Filter up to 0.3 microns. The filtered air is fed to the impeller for circulating in the system.
    • Temperature Control & Timer: A combined Electronic Digital Controller & Timer is installed. ±2ºC., one probe centrally mounted.
    • Scanner: A six point Digital Scanner is incorporated, with facility of Hold & Scan at all six points.
    • Temperature Recorder: A, 1 point Circular Chart recorder is installed with chart Dia. 8”
    • Cooling Coils: Crimped Finned Tubes with headers, S.S. 304 Quality to speed up cooling cycle.
    • Panel Board: Consists of: Ammeters, Voltmeter, Voltmeter switch, HRC fuses & Circular chart Recorder
    • Control panel: Motor Starter, Contactors, Rotary Switches, Indicating lights for heating & Cooling cycle and phase indicating lights.
    • Exhaust damper: Controlled by solenoid valve and is opened during the initial heat-up, shuts off and re-opens during cooling cycle.
    • Fan: Dynamically balanced fan provided for hot air circulation to achieve uniform temperature
    more..
  • Dry Heat Sterilizer

    Dry Heat Sterilizer

    Get Price Quote

    the dry heat sterilizer is used for the sterilization of glass ampoules, vials, containers and vessels in the pharmaceutical and biotechnology industry. Dry heat sterilization is also used for the sterilization of machine components. This dry heat sterilize equipment kills the microbial spore forms up to 12 log decrease. The dry heat sterilizer machine is useful for the sterilization of moisture sensitive materials like glass and metallic containers which can be sterilized using steam but cannot be depyrogenated. The machine is also known as glass container dry heat sterilizer because of its wide use for the dry sterilization of glass ampoules and vials. process of operation the washed vials or ampoules are placed in trays and loaded on the trolley. The trolley is moved on a transfer trolley to the sterilizing machine. The required settings of time and temperature is done by a digital control panel. The hot air is circulated by an impeller horizontally over the charge. The elements on the top heats the air and fresh air is entered into the system via a hepa filter module. The ampoule sterilizer machine has two pneumatically interlocked doors which one for the sterile and other for the non sterile room. The temperature during the sterilization is recorded on a circular chart recorder. A digital temperature scanner provides the validation of the system. salient features: silicon door gasket to ensure zero leakage during the operation optional plc based control panel body of machine is made of s.s. 304 material mineral wool insulation to optimize heat effectiveness temperature variation in the chamber is less then 5 deg c. equipped with hepa filter electronic digital controller and timer

    more..