Rubber Mats Dealers in Amraiwadi, Ahmedabad (2 products available)

  • rubber floor mat

    rubber floor mat

    70 Per Piece

    25 Piece (MOQ)

    • Color: Black
    • Thickness: 0.2-40mm
    • Width: 1-3m
    • Length: upto 10m
    more..
  • RUBBER ELETRIC INSULATION MATS

    RUBBER ELETRIC INSULATION MATS

    Get Price Quote

    Technical Specification :WHAT IS HIGH VOLTAGE INSULATION MATS :High Voltage Insulation Mat are relatively thin mats of thickness (2mm to 3.5 mm) made of elastomeric polymers Material having a high Insulation resistance, thus imparting total safety of human being from any leakage current.ClassThickness (mm) System Voltage Break Down VoltageA 2.0 mm up to 3.3 Kv 30 KvB 2.5 mm 3.3 Kv to 11 Kv 45 KvC 3.0 mm 11 Kv to 33 Kv 65 KvC 3.5 mm up to 66 Kv 110 KvThe Safe Volt Synthetic Insulating Mat- Confirming to IS 15652 : 2006 has superseded the rubber mat with IS 5424 (cold standard) as per the Govt. of India Gazette Notification No. S.O. 2086 dated 17 July 2007 and duly tested by central power research Institute.SPECIFICATION OF INSULATING MATS AS PER is 15652 : 2006a. Insulation ResistancemΩ 1,00,000b. Breakdown TestKv 45c. DielectricKv 45d. Leakage current testing in oilmA 10 (max.)e. Tensile strengthN/mm215 (min.)f. Elongation250 (min.)The Safevolt insulating Mat is a Safety product offering high level of the dielectric strength up 65,000 volt.RECOMMENED USE OF INSULATING MAT :Safevolt Insulating Mat are in total safety in from electric shock for a workman working in or around the electrical insulation as follows -1. The mat is spread in front of the 11 kv switchgear panels / VcB). The fault occurring in the breakers includes short cut. of Bus bars, blowing of spouts and bursting of oil tank of Switchgear (in some cases). The operator operating the said 11 Kv switch-gear is clearly in the safe zone of the safety if he is standing on the synthetic insulated mat.2. Battery Rooms of the Substations by proving Synthetic Insulated Mat. There is complete Safety of the workers cin the said zones during leakage current.3.The insulating mat can be used in front of 33 kv and 66 kv remote panels to protect against leakage currents.4.Generator rooms for safety against leakage current.5.The most important use of the mat is in 66 kv/33 kv yard where the shift staff has to operate the breaker / Isolators manually in case remote control does not function ) . The operator can place the insulated mat in front of the marshalling box thus full – proof protection against the leakage current, if any.Comparision Between Safe Volt Insulating mats and other Mats including Rubber Mats.SAFEVOLT HIGH VOLTAGE INSULATING MATS TRADITIONAL RUBBER MATSHigh Electrical Insulation resistance 10,00,000 mΩ when measured with 500 v meggarPoor Electrical Insulation resistance100% shockproof to 10 MA at 65 Kv tested for total leakage current.Unsafe in case of leakage of current. Tested from shall electrodes as per IS 2584 - 1963 the value of the leakage current is 160 mA per sq meters.Fire retardantHighly fire prone & fire encouraging.No EFFECT OF -ADVERSE EFFECT OF -(a) Transformer oil(a) Transformer oil(b) Acid(b) Acid(c) Alkali(c) Alkali(d) Diesel(d) DieselHigh Dielectric Strength of 45 Kv for 1 minute for MAT size 2.5 mmThe withstand voltage is 15 Kv for one minutePortable type permanent fixed smooth trolley movementCannot be fixed permanentlyHigh Tensile & Elongation properties to withstand good mechanical strengthNo such properties as Mat have to be removed for Movement of trollegs.

    more..
  • Best Deals from Rubber Mats

Filter by Locality
top