Differential Pressure Transmitters Dealers in Gandhi Nagar, Delhi (3 products available)

  • Dwyer 616KD-B-12 Differential Pressure Transmitter

    Dwyer 616KD-B-12 Differential Pressure Transmitter

    Type : Differential Pressure Transmitters

    Material : Plastic

    Certification : YAS

    Weight : 1.8 Oz (51 G)

    Application : Compatible Gases

    Feature : High Performance

    Temperature : 0 To 140°F (-17.8 To 60°C)

    Brand Name : DWYER USA

    Accuracy : ±1% FS

    Output : 4 To 20 MA Or Option With Field Selectable 0 To 10, 0 To 5, 2 To 10, 1 To 5 V.

    ...more
  • Differential Pressure Transmitter

    Differential Pressure Transmitter

    1 - 12,800 Per Piece

    Material : Aluminium, Plastic

    Application : Pressure Measurement

    Color : Grey

    Feature : High Performance

    Frequency : 50Hz

    Brand Name : Dwyer

    Power/Voltage : 10 - 35 VDC (2 Wire)

    ...more
  • Aerosense Series DPT-R8-3W Differential Pressure Transmitter

    Aerosense Series DPT-R8-3W Differential Pressure Transmitter

    Brand Name : Aerosense

    Model Number : Aerosense

    Place of Origin : DELHI

    Aerosense series dpt-r8-3w differential pressure transmitter series dpt-r8-3w differential pressure transmitter monitors pressure the series dpt-r8-3w differential pressure transmitter is an extremely versatile transmitter for monitoring pressure. The compact package is loaded with features such as 8 selectable ranges, 2 selectable outputs, optional display and optional auto-zero feature which electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The auto-zero adjustment takes 4 seconds. The az calibration eliminates all output signal drift due to thermal, electronic or mechanical effects. Optional display and auto-zero feature available. Product applications: building pressure monitoring duct pressure monitoring filter condition monitoring note! supply voltage must be connected one hour before the 0-point adjustment is carried out. Loose both tubes from the pressure inlets + and - push zero button until the red led turns on. Wait until led turns off and then install tubes again to the pressure inlets. It is recommended to adjust the zero point every 12 months during normal operation. If the transmitter is equipped with automatic zero element the manual push button adjustment is not required. Az-calibration is a function in the form of an automatic zeroing circuit built into the pcb. The az-calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The az-calibration eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for technicians to remove high and low pressure tubes when performing initial or periodic transmitter zero point calibration.

    ...more