Technical specifications (stadard):
switching unit:
housing: aluminum, weather proof, powder coated. Integral with the probe suitable for back panel mounting.
Cable entry: 2 nos.
Power consumption: 2 va
Technical specifications (stadard):
switching unit:
housing: aluminum, weather proof, powder coated. Integral with the probe suitable for back panel mounting.
Cable entry: 2 nos.
Power consumption: 2 va
Type: Barstock, Solid Barstock, Deep Drilled and Machine, Tapered or Straight Hot End
Materials: Hexagonal Round AISI 304, 316, 310, 321, 446, Inconel Tungsten Carbide, Cobalt, and Cermeric Coated.
Process connection: Screwed: BSP NPT Metric, Thread Flanged: ASTM BSS DIN
Type: Barstock, Solid Barstock, Deep Drilled and Machine, Tapered or Straight Hot End
Materials: Hexagonal Round AISI 304, 316, 310, 321, 446, Inconel Tungsten Carbide, Cobalt, and Cermeric Coated.
Process connection: Screwed: BSP NPT Metric, Thread Flanged: ASTM BSS DIN
Available in all sizes
(48 X 48) , (72 X 72) , (96 X 96)
Input : J, K, RTD (Pt100)
Output : Relay SSR
Set point : 1
Control mode : Proportional ON - OFF
Relay action : Heat Cool
Available in all sizes
(48 X 48) , (72 X 72) , (96 X 96)
Input : J, K, RTD (Pt100)
Output : Relay SSR
Set point : 1
Control mode : Proportional ON - OFF
Relay action : Heat Cool
Simple Magnetic proven design Float Mounted at one end of rigid rod moves with changes in level .Magnetic capsule at other end rod moves accordingly with fixed micro switch contacts across the phase change accordingly.
Simple Magnetic proven design Float Mounted at one end of rigid rod moves with changes in level .Magnetic capsule at other end rod moves accordingly with fixed micro switch contacts across the phase change accordingly.
TECHNICAL DETAILS
Housing POLYMER Cast Aluminum
Protrusion length 150 mm standard, Extension upto 1 mtrs
Revolution per minute 1 or 2 rpm
wetted parts SS ,PP
Process connection 1-12” BSP 1” (standard) others on request.
Medium temperature 40 °C…+90 °C
Electrical Cable gland 2 nos.
Medium pressure max. 2 bar
Output SPDT 230 V AC, 10 A, (standard) 2X SPDT (Optional)
Power supply 230 V AC, ±15%,
TECHNICAL DETAILS
Housing POLYMER Cast Aluminum
Protrusion length 150 mm standard, Extension upto 1 mtrs
Revolution per minute 1 or 2 rpm
wetted parts SS ,PP
Process connection 1-12” BSP 1” (standard) others on request.
Medium temperature 40 °C…+90 °C
Electrical Cable gland 2 nos.
Medium pressure max. 2 bar
Output SPDT 230 V AC, 10 A, (standard) 2X SPDT (Optional)
Power supply 230 V AC, ±15%,
Rotameter is a device that measures the flow rate of liquid or gas in a closed tube.
A Rotameter consists of a tapered tube, typically made of glass, with a float inside that is pushed up by flow and pulled down by gravity. At a higher flow rate, more area (between the float and the tube) is needed to accommodate the flow, so the float rises. Floats are made in many different shapes, with spheres and spherical ellipses the most common. The float is shaped so that it rotates axially as the fluid passes. This indicates if the float is stuck, since it will only rotate if it is free.
Rotameter is a device that measures the flow rate of liquid or gas in a closed tube.
A Rotameter consists of a tapered tube, typically made of glass, with a float inside that is pushed up by flow and pulled down by gravity. At a higher flow rate, more area (between the float and the tube) is needed to accommodate the flow, so the float rises. Floats are made in many different shapes, with spheres and spherical ellipses the most common. The float is shaped so that it rotates axially as the fluid passes. This indicates if the float is stuck, since it will only rotate if it is free.
A Reliable Level Switch Based on Radio Frequency principle for Solids, Liquids, Slurries.
Levsen RF Level Switch comprises of an electronic controller, a sensing probe and coaxial cable for the connection of the electronic controller to the probe. The Electronic Controller provides RF signals to the probe and measures the changes in parameters provided by the sensing probe mounted in the material (to be measured) container. The sensing probe does not contain any electronics.
A Reliable Level Switch Based on Radio Frequency principle for Solids, Liquids, Slurries.
Levsen RF Level Switch comprises of an electronic controller, a sensing probe and coaxial cable for the connection of the electronic controller to the probe. The Electronic Controller provides RF signals to the probe and measures the changes in parameters provided by the sensing probe mounted in the material (to be measured) container. The sensing probe does not contain any electronics.
Highly resistant to dynamic pressure changes
4-20 mA 2-wire output signal, others available
Special design features improve operator safety
Several process connections available
Stainless steel case and wetted parts
Application: Liquid ,Gas & Vapor .
Highly resistant to dynamic pressure changes
4-20 mA 2-wire output signal, others available
Special design features improve operator safety
Several process connections available
Stainless steel case and wetted parts
Application: Liquid ,Gas & Vapor .
We are offering best PRESSURE GAUGE supplying company.
Available in Panel Clamp Mountings, available in all standard process connections. Accuracy ±2% Dial size 40, 50, 63,100,150,200 & 250 mm
We are offering best PRESSURE GAUGE supplying company.
Available in Panel Clamp Mountings, available in all standard process connections. Accuracy ±2% Dial size 40, 50, 63,100,150,200 & 250 mm
Levsen series MLI -31 Magnetic Level Indicator simple & reliable Level Indicator, Which is based on magnetic principle. It is absolutely safe for dangerous liquid even under high pressure. Magnetic Level Indicators are widely used to observe the Level of tanks or vessels that contain liquid media. Magnetic level gauges utilize a float that contains one or more magnets. As the float rises and falls its magnetic field passes up and down the level column. The level indicator follows the magnetic field.Simple Magnetic proven design Float moves up & down on Probe according to Liquid Level and Fixed limit switches inside the probe change their contacts by magnetic attraction.
Levsen series MLI -31 Magnetic Level Indicator simple & reliable Level Indicator, Which is based on magnetic principle. It is absolutely safe for dangerous liquid even under high pressure. Magnetic Level Indicators are widely used to observe the Level of tanks or vessels that contain liquid media. Magnetic level gauges utilize a float that contains one or more magnets. As the float rises and falls its magnetic field passes up and down the level column. The level indicator follows the magnetic field.Simple Magnetic proven design Float moves up & down on Probe according to Liquid Level and Fixed limit switches inside the probe change their contacts by magnetic attraction.
Tubular Level gauge for visual liquid level observation is very common in process industry. It is a simple and reliable device for direct reading in atmospheric or pressurized tank applications
It is mounted parallel, along the side of tank. As the process level fluctuates, the level in the transparent glass tube changes accordingly and gives local liquid indication.
Tubular Level gauge for visual liquid level observation is very common in process industry. It is a simple and reliable device for direct reading in atmospheric or pressurized tank applications
It is mounted parallel, along the side of tank. As the process level fluctuates, the level in the transparent glass tube changes accordingly and gives local liquid indication.
Maximum Load 16 A 250 V AC
CABLE MATERIAL PVC or Neoprene
CONTACT TYPE Microswitch with NO and NC contact
CONTACT LIFE 10 million switches
SWITCH ANGLE ±45°
SWITCHING SPEED max. 600min.
PROCESS TEMPERATURE 0°C to 70°C
PROCESS PRESSURE max. 5 Bar
LIQUID DENSITY min. 0.8 gcm3
HOUSING MATERIAL non-toxic polypropylene
PROTECTION IP 68
CABLE SPECIFICATION Ø 9 mm 3x1.5 mm2
Maximum Load 16 A 250 V AC
CABLE MATERIAL PVC or Neoprene
CONTACT TYPE Microswitch with NO and NC contact
CONTACT LIFE 10 million switches
SWITCH ANGLE ±45°
SWITCHING SPEED max. 600min.
PROCESS TEMPERATURE 0°C to 70°C
PROCESS PRESSURE max. 5 Bar
LIQUID DENSITY min. 0.8 gcm3
HOUSING MATERIAL non-toxic polypropylene
PROTECTION IP 68
CABLE SPECIFICATION Ø 9 mm 3x1.5 mm2