Table Top Sterilizer Dealers in Inderpuri, Delhi (1 products available)

  • table top steam sterilizer

    table top steam sterilizer

    Get Price Quote

    Table Top Steam Sterilizer (Pre & Post Vacuum Facility)   “NSW” pleased to introduce table top steam sterilizer for today’s growing demand for more sophisticated sterilization technologies. Any private or dental clinic can enjoy the benefit of this technology right in their office. Outpatient clinics, which have increased significantly in recent years, perform highly skilled invasive surgery on their own premises. They rely on advanced sterilization technology. In addition, the increasing tendency towards modular space design in the clinic makes our pre & post vacuum tabletop autoclaves the perfect solution. Construction: This autoclave is made of complete stainless steel 304 Qlty having outer & inner wall & has capacity of 22 liters chamber has compact outer dimensions making it a perfect fit for today’s contemporary clinic. There is mineral wool insulation between the two walls .Designed to sterilize class B cycles. A common application is in the medical or (operating room) as an independent sterilization unit or in dental and private clinics that need to sterilize narrow and hollow instruments and wrapped packs. It has 2 nos. perforated shelves. The water reservoir has capacity of 6 liters of distilled or low quality deionized water. This sterilizer are designed to perform class B cycle that meet the strictest EN 13060 European standards.  Pre Vacuum Air Removal: Porous and packed load types as well as fabrics have one thing in common: Air is trapped inside these instruments and fabrics, resulting in air pockets that prevent the full penetration of steam. It is known that spores and bacteria can survive at 134 Deg.C in air pockets.  Therefore, pre vacuum air removal eliminates air pockets from all load types and maximizes steam penetration to instrument components. Post Vacuum Drying: When hot steam comes in contact with the cooler instruments, condensation can form. Condensation becomes even more serious with packaged loads, when moisture can remain after the cycle ends. A moist load does not provide sufficient SAL (Sterility Assurance Level). Post vacuum drying provides complete drying of porous loads and hollow instruments at the end of the sterilization process. Temperature Control: Temperature shall be controlled by Microprocessed PID Controller which will have following features: Auto purging: Set Temp. Purging Stop: - Set Temp. Auto Exhaust:- Cool Elapse Time Set Temperature:- Could be set Facility for temp. control Auto cycle stop Buzzer at cycle over Operating Temp. 121 Deg.C to 135 Deg.C Sterilizing Pressure 1.2 to 2.3 kg /Cm2 Pressure can be achieved upto 760mm/ hg approx. This sterilizer work on 200/ 220 volts A.C 50 Hz. Option:PC connection port for direct PC access enables direct software updates and remote maintenance or data can be collected through USB port.  

    more..
Filter by Locality
top