Lightning arresters are manufactured using high quality raw material which is used to protect electrical equipment from medium and high voltage.
Application
A lightning arrester / Surge Arrester is a device used on electrical power systems to protect the insulation of transformer and conductors of the system from the damaging effects of lightning. The typical lightning surge arrester has a high-voltage terminal and a ground terminal. When a lightning surge (or switching surge, which is very similar) travels along the power line to the arrester, the current from the surge is diverted through the arrestor, in to earth.
Construction
Our lightning surge arresters are Gapless metal-oxide type, consist of Zinc-oxide Varistors, FRP Core and Silicone Housing.
Lightning arresters are manufactured using high quality raw material which is used to protect electrical equipment from medium and high voltage.
Application
A lightning arrester / Surge Arrester is a device used on electrical power systems to protect the insulation of transformer and conductors of the system from the damaging effects of lightning. The typical lightning surge arrester has a high-voltage terminal and a ground terminal. When a lightning surge (or switching surge, which is very similar) travels along the power line to the arrester, the current from the surge is diverted through the arrestor, in to earth.
Construction
Our lightning surge arresters are Gapless metal-oxide type, consist of Zinc-oxide Varistors, FRP Core and Silicone Housing.
Heat Shrinkable Stress Control Tubing Enquire Now
Features
DSCT is made from radiation crosslinked polymeric materials
Effectively control the high electrical stress present at insulation screen termination and joint of power cables
Minimum shrink temperature: 100oC
Minimum fully recovered temperature:1300C
Heat Shrinkable Stress Control Tubing Enquire Now
Features
DSCT is made from radiation crosslinked polymeric materials
Effectively control the high electrical stress present at insulation screen termination and joint of power cables
Minimum shrink temperature: 100oC
Minimum fully recovered temperature:1300C
Features
Live Installation
Anti-tracking
Light Weight
Superior UV and Abrasion Resistance
Weather Resistance
Range Taking
Quick Installation
Localized Installation
Features
Live Installation
Anti-tracking
Light Weight
Superior UV and Abrasion Resistance
Weather Resistance
Range Taking
Quick Installation
Localized Installation
Heat Shrinkable Semi Conductive Breakout
Enquire Now
Features
Breakout can be used to cable terminations up to 36 KV
The electrically semi-conductive breakout provide effective conductive screen and sealing protection to the cable termination
Minimum fully recovered temperature:130oC
Heat Shrinkable Semi Conductive Breakout
Enquire Now
Features
Breakout can be used to cable terminations up to 36 KV
The electrically semi-conductive breakout provide effective conductive screen and sealing protection to the cable termination
Minimum fully recovered temperature:130oC
Pre Moulded Straight Through Joint 11 kV (for XLPE Cable)
DPMS/S-11kV
Enquire Now
Features
Cold-applied.
No Special Tools.
Constant Radial Pressure.
In Built Stress Control Arrangement
Un limited Shelf Life.
In compliance with IEC-60502-4.
Pre Moulded Straight Through Joint 11 kV (for XLPE Cable)
DPMS/S-11kV
Enquire Now
Features
Cold-applied.
No Special Tools.
Constant Radial Pressure.
In Built Stress Control Arrangement
Un limited Shelf Life.
In compliance with IEC-60502-4.
Features
Cold-applied.
No Special Tools.
Constant Radial Pressure.
In Built Stress Control Arrangement
Un limited Shelf Life.
In compliance with IEC-60502-4.
Features
Cold-applied.
No Special Tools.
Constant Radial Pressure.
In Built Stress Control Arrangement
Un limited Shelf Life.
In compliance with IEC-60502-4.
Features
Light weight (65-80% less than ceramic insulator)
Silicon rubber sheds provide perfect hydrophobic performance, good resistance to ageing, tracking and erosion
Stable behaviour at extreme climatic conditions
Long term surface hydrophobicity
Suitable for polluted environment, salty atmospheres etc.
Resistance to breakage and vandalism, practically unbreakable
Superior anti-tracking properties
High mechanical strength
Ease of installation (easier handling with lighter equipment and labour at the job site)
Resistance to Seismic Shock
Compliance with IEC 61109, ANS C29-11-1989
Features
Light weight (65-80% less than ceramic insulator)
Silicon rubber sheds provide perfect hydrophobic performance, good resistance to ageing, tracking and erosion
Stable behaviour at extreme climatic conditions
Long term surface hydrophobicity
Suitable for polluted environment, salty atmospheres etc.
Resistance to breakage and vandalism, practically unbreakable
Superior anti-tracking properties
High mechanical strength
Ease of installation (easier handling with lighter equipment and labour at the job site)
Resistance to Seismic Shock
Compliance with IEC 61109, ANS C29-11-1989
Application
The Polymer Air Break Switch is gang operated and outdoor Type. The main Application of this product is to isolate the Transformer, Overhead lines, System or Cables from distribution network.
Construction
Our Polymer Air Break Switch have Two Pole/Triple pole construction and suitable for Vertical / Horizontal mounting. Each pole consist of galvanised steel base, Polymeric Post insulators, Self aligning type contacts made of hard drawn electrolytic copper/heavily tinned .The various parts accordingly finished to ensure interchangeability of similar components. Flexible braided tape is of EC grade tin plated copper of appropriate size to complete the current path from moving contact to fix contact.
Application
The Polymer Air Break Switch is gang operated and outdoor Type. The main Application of this product is to isolate the Transformer, Overhead lines, System or Cables from distribution network.
Construction
Our Polymer Air Break Switch have Two Pole/Triple pole construction and suitable for Vertical / Horizontal mounting. Each pole consist of galvanised steel base, Polymeric Post insulators, Self aligning type contacts made of hard drawn electrolytic copper/heavily tinned .The various parts accordingly finished to ensure interchangeability of similar components. Flexible braided tape is of EC grade tin plated copper of appropriate size to complete the current path from moving contact to fix contact.
Polymeric Drop Out Fuse (Solid Core) are manufactured using highly conductive copper alloy. These current limiting fuses are installed at high voltage and are used to provide protection when the trouble is consistent
Application
Our Drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution system for protection of H. T. lines and transformer centers Tap lines.
Construction
The Drop out fuse set has single pole construction. Each pole consist of Polymeric insulators, all current carrying parts made of a highly conductive copper alloy and the contact portion are silver plated for corrosion resistance and efficient current flow & the fuse tube made of fiber glass coated with ultraviolet inhibitor on the outer surface and having arc quenching bone fiber liner inside.
Polymeric Drop Out Fuse (Solid Core) are manufactured using highly conductive copper alloy. These current limiting fuses are installed at high voltage and are used to provide protection when the trouble is consistent
Application
Our Drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution system for protection of H. T. lines and transformer centers Tap lines.
Construction
The Drop out fuse set has single pole construction. Each pole consist of Polymeric insulators, all current carrying parts made of a highly conductive copper alloy and the contact portion are silver plated for corrosion resistance and efficient current flow & the fuse tube made of fiber glass coated with ultraviolet inhibitor on the outer surface and having arc quenching bone fiber liner inside.
Salient Features
Sheet Metal Enclosure-Pre-treated & Powder Coated
Bolted Construction
Extendable from both sides of penal
PVC Insulated Busbar
No live parts accessible & exposed
In-built safety shutter
All Switching operations performed with front door closed
Circuit Breaker withdraw type with interlock & fixed type
Separate compartment for Breaker, Busbar, CT/Cable & Instrument chamber
Access to cable terminals from the rear
Maintenance & Operation
Maintenance free vacuum interrupters and low maintenance drive mechanism
Front access door fully integrated with interlock system
Complete mechanical interlocking provided
Salient Features
Sheet Metal Enclosure-Pre-treated & Powder Coated
Bolted Construction
Extendable from both sides of penal
PVC Insulated Busbar
No live parts accessible & exposed
In-built safety shutter
All Switching operations performed with front door closed
Circuit Breaker withdraw type with interlock & fixed type
Separate compartment for Breaker, Busbar, CT/Cable & Instrument chamber
Access to cable terminals from the rear
Maintenance & Operation
Maintenance free vacuum interrupters and low maintenance drive mechanism
Front access door fully integrated with interlock system
Complete mechanical interlocking provided
Features
Application : Insulating, Pressure & humidity-tight sheathings, Suitable for cable joints & terminations
Material : Cross linked polyolefin, free of lead & cadmium
Colour : Black
Medium wall
High Tensile strength
Resistant to cold flow
Very good chemical & electrical properties
Non-corrosive
UV-resistant
Continuous operation temperature: -55 degrees to 125 degrees centigrade
In conformance with ESI 09 - 13
Features
Application : Insulating, Pressure & humidity-tight sheathings, Suitable for cable joints & terminations
Material : Cross linked polyolefin, free of lead & cadmium
Colour : Black
Medium wall
High Tensile strength
Resistant to cold flow
Very good chemical & electrical properties
Non-corrosive
UV-resistant
Continuous operation temperature: -55 degrees to 125 degrees centigrade
In conformance with ESI 09 - 13
Heat Shrinkable Cable End Caps
Enquire Now
Features
Effectively offering protection against oxidation, ozone, UV radiation etc
Coated with hot melt adhesive to ensure environment seal
Easily to fit over the cable end
Protect power cable up to 1000V and telecommunication cable
Material: Thermally stabilized cross-linked polyolefin, coated with specially designed hot melt adhesive
Minimum fully shrink temperature:120 oC
Heat Shrinkable Cable End Caps
Enquire Now
Features
Effectively offering protection against oxidation, ozone, UV radiation etc
Coated with hot melt adhesive to ensure environment seal
Easily to fit over the cable end
Protect power cable up to 1000V and telecommunication cable
Material: Thermally stabilized cross-linked polyolefin, coated with specially designed hot melt adhesive
Minimum fully shrink temperature:120 oC
Features
DBIT is made from radiation cross linked polyolefin
The dual layer structure of insulation/hot melt adhesive
Widely used to protect complex busbar connections where tube products can not be applied
Up to 24 KV
Features
DBIT is made from radiation cross linked polyolefin
The dual layer structure of insulation/hot melt adhesive
Widely used to protect complex busbar connections where tube products can not be applied
Up to 24 KV
Features
All key inputs are produced in-house.
Continuous operation temperature-55oC to 120oC.
Corrosion resistant and unlimited shelf life.
In compliance with IEC-60502-4 / IS-13573.
Electrolytic grade connectors.
Features
All key inputs are produced in-house.
Continuous operation temperature-55oC to 120oC.
Corrosion resistant and unlimited shelf life.
In compliance with IEC-60502-4 / IS-13573.
Electrolytic grade connectors.
FRP Cross Arms
Both 11kV and 33kV FRP Cross Arms are Manufactured as per the latest REC specifications by Pultrusion Process.
Features
Weather resistant specially for coastal areas
Light weight for easy installation in hilly areas
Avoidance of birdage problem
Continuance of power supply even after insulators are cracked
Lower size insulators can be used reducing the cost of insulators
FRP Cross Arms
Both 11kV and 33kV FRP Cross Arms are Manufactured as per the latest REC specifications by Pultrusion Process.
Features
Weather resistant specially for coastal areas
Light weight for easy installation in hilly areas
Avoidance of birdage problem
Continuance of power supply even after insulators are cracked
Lower size insulators can be used reducing the cost of insulators
Features
Simple installation, requires only workman’s hands
Accommodates a wide range of cable sizes
No torches or heat required
Good thermal stability and water proof
Seals tight, retains its resiliency and pressure even after prolonged years of aging and exposure
Excellent wet electrical properties
Improved tough rubber formulation to with stand rough backfilling
Resists fungus,acids ,alkalis,ozone and ultraviolet light
Features
Simple installation, requires only workman’s hands
Accommodates a wide range of cable sizes
No torches or heat required
Good thermal stability and water proof
Seals tight, retains its resiliency and pressure even after prolonged years of aging and exposure
Excellent wet electrical properties
Improved tough rubber formulation to with stand rough backfilling
Resists fungus,acids ,alkalis,ozone and ultraviolet light
The Elbow Connectors 25 kV-250, 400 & 630 amps Shielded Connector is shielded and insulated termination, rated 250, 400 & 630 amps upto 24 kV, conected with underground cable ranging from 25 to 400mm2 (conductor cross section). Meets requirements of DIN 47636 standard.
Elbow Connectors 24 kV - 250, 400 & 630 amps Shielded Connectors are molded using high quality peroxide-cured EPDM insulation. It is used to terminate high quality voltage underground cable to switchgear, RMU and 250, 400 & 630 amps junctions equipped with deadbreak bushing. Shielded Fore-Connectors are designed for usage on solid dielectric cable (XLPE or EPR). In order to provide more cable branch circuits, the shielded fore connectors can be connected with the 24 kV - 250, 400 & 630 Shielded type Sub- Connector.
Features
Safe to touch.
Capacitive test point.
Faster installation.
Non-corrosive and UV resistant
In-built stress control offering high stress control properties
Outstanding mechanical, chemical & electrical properties.
Unlimited shelf-life.
In compliance with IEC-60502-4.
The Elbow Connectors 25 kV-250, 400 & 630 amps Shielded Connector is shielded and insulated termination, rated 250, 400 & 630 amps upto 24 kV, conected with underground cable ranging from 25 to 400mm2 (conductor cross section). Meets requirements of DIN 47636 standard.
Elbow Connectors 24 kV - 250, 400 & 630 amps Shielded Connectors are molded using high quality peroxide-cured EPDM insulation. It is used to terminate high quality voltage underground cable to switchgear, RMU and 250, 400 & 630 amps junctions equipped with deadbreak bushing. Shielded Fore-Connectors are designed for usage on solid dielectric cable (XLPE or EPR). In order to provide more cable branch circuits, the shielded fore connectors can be connected with the 24 kV - 250, 400 & 630 Shielded type Sub- Connector.
Features
Safe to touch.
Capacitive test point.
Faster installation.
Non-corrosive and UV resistant
In-built stress control offering high stress control properties
Outstanding mechanical, chemical & electrical properties.
Unlimited shelf-life.
In compliance with IEC-60502-4.
Features
Simple Structure, pre-fabricated, & factory tested.
Ready to use and easy to install.
Minimises jointer’s skills.
Made from LSR, delivering better Electrical and Outdoor Performance.
In compliance with IEC-60502-4 / IS:13573.
Features
Simple Structure, pre-fabricated, & factory tested.
Ready to use and easy to install.
Minimises jointer’s skills.
Made from LSR, delivering better Electrical and Outdoor Performance.
In compliance with IEC-60502-4 / IS:13573.
Features
Simple Structure, pre-fabricated, & factory tested.
Ready to use and easy to install.
Minimises jointer’s skills.
Made from LSR, delivering better Electrical and Outdoor Performance.
In compliance with IEC-60502-4 / IS:13573.
Features
Simple Structure, pre-fabricated, & factory tested.
Ready to use and easy to install.
Minimises jointer’s skills.
Made from LSR, delivering better Electrical and Outdoor Performance.
In compliance with IEC-60502-4 / IS:13573.
Features
Designed for medium voltage applications up to 36 KV
Shaped components to meet a variety of configuration requriements
Continuous operation temperature: -55° C to 120° C
Used in proctecting cable and up to 36 KV against flashover or surges induce during working life in switch gear in and transformer boxes.
Features
Designed for medium voltage applications up to 36 KV
Shaped components to meet a variety of configuration requriements
Continuous operation temperature: -55° C to 120° C
Used in proctecting cable and up to 36 KV against flashover or surges induce during working life in switch gear in and transformer boxes.
Heat Shrinkable Anti Tracking Rain Sheds
Enquire Now
Features
Designed for medium voltage applications up to 36 KV
Shaped components to meet a variety of configuration requriements
Continuous operation temperature: -55° C to 120° C
High creep resistance, anti-tracking properties
Heat Shrinkable Anti Tracking Rain Sheds
Enquire Now
Features
Designed for medium voltage applications up to 36 KV
Shaped components to meet a variety of configuration requriements
Continuous operation temperature: -55° C to 120° C
High creep resistance, anti-tracking properties
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Year of Establishment1973
No. of Employees251 - 500
Annual TurnoverRs. 2.5 to 5 Crore Approx.
Ownership TypeCorporation/Limited Liability Company
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
We are the manufacturer and supplier of a wide variety of power cable jointing system and cable termination kits. We can proudly say that we are the first organization in india to supply a complete array of cable jointing kits and cable termination kits for vacuum circuit breakers up to 36 kv, polymeric insulators up to 400 kv, power cables up to 66 kv.