Earthing Equipment Dealers in Ghukna, Ghaziabad

(10 products available)
  • Chemical Earthing Electrodes

    Chemical Earthing Electrodes

    1,000 / Piece

    • MaterialGalvanized Iron (GI)
    • ApplicationEarthing
    • FinishingPolished
    • Brand NamePower One Earthing System
    • Length Of Rod3 meter
    • Diameter50mm
    ...more
  • Chemical Earthing Electrodes

    Chemical Earthing Electrodes

    Get Price Quote

    • MOQ100 Piece
    • MaterialAluminium
    • ApplicationEarthing Purpose
    • Length0-250mm
    • Number Of FlowerChemical Earthing Electrodes
    • Thickness0-3mm
    • Availability0-50gm
    • We are counted among the well known Manufacturers, Suppliers and Exporters of Chemical Earthing Electrodes. The Electrodes we make available dissipates lightning strikes and discharges. EPABX Systems/RF Antennae, Transformers HT/LT, Panels Distribution/Power factor, CNC m/c, Testing Equipment /System, Uninterrupted Power Supply, Generators, etc. are some of the components required for the proper functioning of our Earthing Electrodes. One can obtain these at market-leading rates from us. Statutory Requirements ofEarthing/Grounding of System/equipmentAs per Indian Earthing Standard IS 3043:1987EPABX Systems/RF Antennae Etc Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. Provision should be there for at least one distinct separate dedicated Neutral Earthing in order to provide localized Neutral to make Neutral strong and provide path to residual voltage of Neutral. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system Transformers HT/LT In case Transformers HT/LT : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life.   The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage.Panels Distribution/Power factor In case of  Panels for Distribution/Power factor : Provision should be there for at least two distinct separate bodies Earthing in order to provide safety aspects for shock to human life. CNC m/c In case of medium and high rating CNC m/c : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects of electronic circuit and for shock to human life. It provides safety of electronic circuit against surges/spikes generated by the induction current.   The Neutral should be Earthed with at least one distinct separate Earthing in order to achieve sufficient current dissipation and consistent/low Neutral – Earth voltage.Testing Equipment /System Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system.   Uninterrupted Power Supply Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and interruption of sinusoidal charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system. Generators In case of medium and high rating generators : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life.   The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage   In case of Extra high rating generators: Number of Body/Neutral earthing points should be increased in order to cope up with high spurious voltage generated by the equipment.
    ...more
    www
  • Copper Earthing Strips

    Copper Earthing Strips

    Get Price Quote

    Established as an admired figure in the industry, we are engaged in delivering Copper Earthing Strips. They are popular worldwide due to their dimensional accuracy and robust construction. A number of quality tests are run by our quality team to match necessary industrial grades. We cater to bulk requirements of the customers. We put quality on the top of our priority list.
    ...more
  • Gi Earthing Strip

    Gi Earthing Strip

    61 / Kilogram

    • MaterialGalvanized Iron
    • Country of OriginMade in India
    • Equipment TypeCopper Bonded Grounding Rod
    • Usage/ApplicationIndustrial/Residential
    • FinishPolished
    • BrandSG Power
    ...more
  • Copper Bonded Ground Rods

    Copper Bonded Ground Rods

    Get Price Quote

    Copper Bonded Ground Rods, Backfill Earthing Compoun
  • Earthing Electrode

    Earthing Electrode

    Get Price Quote

    Earthing Electrod
  • Earthing Electrodes

    Earthing Electrodes

    Get Price Quote

    Earthing Electrodes, Soya Chaap, Carpenter, Wallpaper, Soya Chaap, Plumbe
  • Chemical Earthing Electrode

    Chemical Earthing Electrode

    Get Price Quote

    Chemical Earthing Electrode, Copper Earthing Electrodes, Chemical Earthin
  • Pipe Earth Electrode

    Pipe Earth Electrode

    Get Price Quote

    Pipe Earth Electrode, Overhead Electric Line Accessories, Solar Light Pole
  • Earthing Electrode

    Earthing Electrode

    Get Price Quote

    Earthing Electrode, Back Fill Earthung Compoun
Filter by Locality
top