Storage tanks (SS 316L) are very critical component in the Storage & Distribution systems. It is the most vulnerable component too. Because of the large diameter, it is not possible to maintain the turbulence (water flow velocities) as we can in the loop. It is of critical importance that a very high level of surface finish and an effective flushing mechanism (spray ball system) be efficiently designed and installed. It is also important to maintain the required tank volume turn overs per hour to ensure the microbial counts are below the alert limit (possibly around
Storage tanks (SS 316L) are very critical component in the Storage & Distribution systems. It is the most vulnerable component too. Because of the large diameter, it is not possible to maintain the turbulence (water flow velocities) as we can in the loop. It is of critical importance that a very high level of surface finish and an effective flushing mechanism (spray ball system) be efficiently designed and installed. It is also important to maintain the required tank volume turn overs per hour to ensure the microbial counts are below the alert limit (possibly around
When we design your Storage & Distribution System, we are putting in more than 15 years of our experience into the design. This means all the basic & micro-level but critical requirements like no dead legs, all instruments facing the operator, usage of all sanitary instruments, sampling points, distance piece for swab test, pump interchange with one swing of the pump inlet connector and many more are automatically taken care of.Would you like to know how many significant advantages that we can offer you with our design? Call us to learn more. We are sure you will appreciate each one of them.
When we design your Storage & Distribution System, we are putting in more than 15 years of our experience into the design. This means all the basic & micro-level but critical requirements like no dead legs, all instruments facing the operator, usage of all sanitary instruments, sampling points, distance piece for swab test, pump interchange with one swing of the pump inlet connector and many more are automatically taken care of.Would you like to know how many significant advantages that we can offer you with our design? Call us to learn more. We are sure you will appreciate each one of them.
The criticality of the Reverse Osmosis System to generate Purified Water cannot be overstated. Its easily at the core of any pharmaceutical water treatment plant. A well designed RO System ensures consistent quality output (less than 10 micro-siemens cms), a feed which the EDI can easily take care. When we design the RO, you can be assured that every component is checked for the best sanitary design that is possible. SS316L Pressure tubes, Diaphragm valves (with exceptions of brine control valve) Block valves for sampling, sanitary instruments like conductivity sensors, Pressure Gauges, Flow transmitters ensure the most sanitary and reliable makes that are available in the market. We expertise in membrane selection and sizing ensures that you get the best possible recovery from your water. We optimize but also ensure that the microbial concerns take precedence over other optimization benefits. For example, we do not recirculate the reject water in between the stages (which is conventional and best practice for all non-pharmaceutical Water applications). This recirculation can have acascading effect in case you have a microbial attack.
The criticality of the Reverse Osmosis System to generate Purified Water cannot be overstated. Its easily at the core of any pharmaceutical water treatment plant. A well designed RO System ensures consistent quality output (less than 10 micro-siemens cms), a feed which the EDI can easily take care. When we design the RO, you can be assured that every component is checked for the best sanitary design that is possible. SS316L Pressure tubes, Diaphragm valves (with exceptions of brine control valve) Block valves for sampling, sanitary instruments like conductivity sensors, Pressure Gauges, Flow transmitters ensure the most sanitary and reliable makes that are available in the market. We expertise in membrane selection and sizing ensures that you get the best possible recovery from your water. We optimize but also ensure that the microbial concerns take precedence over other optimization benefits. For example, we do not recirculate the reject water in between the stages (which is conventional and best practice for all non-pharmaceutical Water applications). This recirculation can have acascading effect in case you have a microbial attack.
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Sanpure is promoted by a experienced and committed team of experts who have designed, built and operated water systems for many major pharmaceticals in India and abroad. Right from the early nineties when the USP for PW was in its infancy in india till date when its on par with the best in the world, we have been designing, engineering and erecting systems for many major pharmaceuticals.