styrax wireless synchronized master clock system operates on a very basic concept. The master clock acquires the time and then transmits it wirelessly to the slave clocks that are in the system. Once the transmitter master clock receives a time update, it then transmits the time to any number of secondary slave digital clocks. The digital clocks need only a 240v ac power outlet; they include their own internal battery pack with 5 year life.
styrax wireless synchronized master clock system operates on a very basic concept. The master clock acquires the time and then transmits it wirelessly to the slave clocks that are in the system. Once the transmitter master clock receives a time update, it then transmits the time to any number of secondary slave digital clocks. The digital clocks need only a 240v ac power outlet; they include their own internal battery pack with 5 year life.
STYRAX manufacturers’ digital synchronized master clock systems, and other LED clocks. All clocks can display the same, accurate, legal time. STYRAX commercial digital clocks are specifically designed for applications where precision and reliability are of utmost importance. These clocks may be used as accurate stand-alone time displays. They can also be synchronized so that all clocks display the same time. SDC105M clock synchronizes the Slave Clocks (i.e.SDC1051S, SDC1052S) every second within the RS485 network.
Applications:
HVAC (Heating, ventilation, Air conditioning, cooling).
Pharmacy industry.
Blood stations, pharmacies.
Horticultural and cultivation of plants
Applications:
The following are the main application areas where synchronized digital clocks play an important role.
Pharmaceutical industries
Process Industries
Warehouse
Railways
Mass Production Factories
Conference halls
Examination Halls
Colleges etc
Key Features:
Advanced Microcontroller Based Master clock
Reliable LED display
High readability
Synchronizes Slaves Every Second
Flicker-free Bright Seven Segment LED Display
User friendly programming modes
Lithium Battery ensures correct time after power failure.
Time Displays in 24 Hrs Format (HH:MM:SS)
Red filter Transparent overlay facilitates Wide Viewing Angle
Interface communication: RS485/RF
STYRAX manufacturers’ digital synchronized master clock systems, and other LED clocks. All clocks can display the same, accurate, legal time. STYRAX commercial digital clocks are specifically designed for applications where precision and reliability are of utmost importance. These clocks may be used as accurate stand-alone time displays. They can also be synchronized so that all clocks display the same time. SDC105M clock synchronizes the Slave Clocks (i.e.SDC1051S, SDC1052S) every second within the RS485 network.
Applications:
HVAC (Heating, ventilation, Air conditioning, cooling).
Pharmacy industry.
Blood stations, pharmacies.
Horticultural and cultivation of plants
Applications:
The following are the main application areas where synchronized digital clocks play an important role.
Pharmaceutical industries
Process Industries
Warehouse
Railways
Mass Production Factories
Conference halls
Examination Halls
Colleges etc
Key Features:
Advanced Microcontroller Based Master clock
Reliable LED display
High readability
Synchronizes Slaves Every Second
Flicker-free Bright Seven Segment LED Display
User friendly programming modes
Lithium Battery ensures correct time after power failure.
Time Displays in 24 Hrs Format (HH:MM:SS)
Red filter Transparent overlay facilitates Wide Viewing Angle
Interface communication: RS485/RF
RTD sensor are temperature sensors that has a resistor inside that changes resistance value as its surrounding temperature changes. RTDs are being used for many years to measure temperature in industrial processes, labs and have developed a reputation for stability, repeatability and accuracy.
RTD sensor are temperature sensors that has a resistor inside that changes resistance value as its surrounding temperature changes. RTDs are being used for many years to measure temperature in industrial processes, labs and have developed a reputation for stability, repeatability and accuracy.
The STYRAX “Clean Room Process Monitor” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Monitor can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Monitor has status LEDs for process violation indication. RH, Temperature and Differential pressure will display individually and data transfers to any master device on MODBUS RTU RS-485 communication. It also has communication diagnosis LED. The monitor has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has Stainless steel Modular Face plate, which is designed as a mounting accessory for monitor suited for Brick and Modular wall for Clean Room applications where you need flush mounting mechanism.
Features :
Advanced Microcontroller based process measurement.
Programmable channel ranges and unit selections.
Programmable resolution.
4 Digit, 0.39 bright 7- Segment LED display for displaying Temperature, RH and DP.
User selectable set limits for process value violation.
Process parameter status indication with 3 Bi-Color 3mm LEDs.
Inbuilt buzzer to audible process value violation.
Password protection for calibration and programming mode.
Software Calibration for 3 channels.
MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA, etc.
Programmable baud rate between 9.6k/19.2k/38.4k.
Diagnosis indication of Communication with master.
User programmable offset correction.
Brick and modular wall mounting.
Stainless steel enclosure.
Specifications:
Input Type
Inbuilt Integral Sensors/4-20mA/0 to 10VDC.
The STYRAX “Clean Room Process Monitor” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Monitor can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Monitor has status LEDs for process violation indication. RH, Temperature and Differential pressure will display individually and data transfers to any master device on MODBUS RTU RS-485 communication. It also has communication diagnosis LED. The monitor has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has Stainless steel Modular Face plate, which is designed as a mounting accessory for monitor suited for Brick and Modular wall for Clean Room applications where you need flush mounting mechanism.
Features :
Advanced Microcontroller based process measurement.
Programmable channel ranges and unit selections.
Programmable resolution.
4 Digit, 0.39 bright 7- Segment LED display for displaying Temperature, RH and DP.
User selectable set limits for process value violation.
Process parameter status indication with 3 Bi-Color 3mm LEDs.
Inbuilt buzzer to audible process value violation.
Password protection for calibration and programming mode.
Software Calibration for 3 channels.
MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA, etc.
Programmable baud rate between 9.6k/19.2k/38.4k.
Diagnosis indication of Communication with master.
User programmable offset correction.
Brick and modular wall mounting.
Stainless steel enclosure.
Specifications:
Input Type
Inbuilt Integral Sensors/4-20mA/0 to 10VDC.
FeatureProgrammable resolution. , Software Calibration for 3 channels.
Input TypeInbuilt Integral Sensors/4-20mA/0 to 10VDC.
Temp40°C to 100°C.
The STYRAX “Clean Room Process Monitor” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Monitor can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Monitor has status LEDs for process violation indication. RH, Temperature and Differential pressure will display individually and data transfers to any master device on MODBUS RTU RS-485 communication. It also has communication diagnosis LED. The monitor has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user
The STYRAX “Clean Room Process Monitor” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Monitor can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Monitor has status LEDs for process violation indication. RH, Temperature and Differential pressure will display individually and data transfers to any master device on MODBUS RTU RS-485 communication. It also has communication diagnosis LED. The monitor has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user
Feature : Programmable resolution. , Software Calibration for 3 channels.
FeatureProgrammable channel ranges and unit selections. and Programmable resolution.
Measuring Ranges:Inbuilt Sensor: 0°C to 50°C. Analog Input: -199.9°C to 999.9°C.
Resolution:Temperature:0.1°C.
The STYRAX “Temperature Controllers” has been specially developed keeping process measurement requirements in Pharmaceutical industries. The Temperature Controller can measure Temperature Inbuilt integral Sensor, or analog input. The Temperature Controller has status LEDs for process violation indication, the process data transfers to any master device on MODBUS RTU RS-485 communication. It also communication diagnosis LED for SCADA communication. The controller has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has Stainless steel Modular Face plate, which is designed as a mounting accessory for monitor suited for Brick and Modular wall for Clean Room applications where you need flush mounting mechanism.
The STYRAX “Temperature Controllers” has been specially developed keeping process measurement requirements in Pharmaceutical industries. The Temperature Controller can measure Temperature Inbuilt integral Sensor, or analog input. The Temperature Controller has status LEDs for process violation indication, the process data transfers to any master device on MODBUS RTU RS-485 communication. It also communication diagnosis LED for SCADA communication. The controller has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has Stainless steel Modular Face plate, which is designed as a mounting accessory for monitor suited for Brick and Modular wall for Clean Room applications where you need flush mounting mechanism.
Feature : Programmable channel ranges and unit selections. and Programmable resolution.
FeatureAdvanced Microcontroller based process measurement. , Programmable resolution.
%RH0.0 to 100%RH.
Temperature40°C to 100°C.
ClockHH:MM (Hours and Minutes format only)
The STYRAX “Clean Room Process Scanner” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Scanner can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Clean Room Process Scanner displays Real Time Clock synchronized with GPSServer based master clock interfaced through RS485
The STYRAX “Clean Room Process Scanner” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Scanner can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Clean Room Process Scanner displays Real Time Clock synchronized with GPSServer based master clock interfaced through RS485
Feature : Advanced Microcontroller based process measurement. , Programmable resolution.
The STYRAX “Temperature and RH Transmitter” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. RHT105 is a high-performance 4-wired Relative Humidity and Temperature Transmitter. Its relative humidity and temperature transmitter is available in surface mount, duct mount and remote sensor versions. This transmitter is accurate to 1.5% for relative humidity and within 0.3 °C for temperature. RHT105 transmits two isolated output signals to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. The RH+T transmitter is user programmable by a PC, connected via Configuration software by STYRAX.
Features :
Advanced Microcontroller based process measurement.
Software programmable measurement range settings.
5-point calibration for Temperature.
5-point calibration for RH.
High input impedance.
Software calibration – No trim pots.
PC programmable.
Operating Voltage
24VDC.
Enclosure
ABS IP65.
Sensor Tube
SS304.
Filter
Sintered bronze.
Protection
IP65 except sensor tube.
The STYRAX “Temperature and RH Transmitter” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. RHT105 is a high-performance 4-wired Relative Humidity and Temperature Transmitter. Its relative humidity and temperature transmitter is available in surface mount, duct mount and remote sensor versions. This transmitter is accurate to 1.5% for relative humidity and within 0.3 °C for temperature. RHT105 transmits two isolated output signals to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. The RH+T transmitter is user programmable by a PC, connected via Configuration software by STYRAX.
Features :
Advanced Microcontroller based process measurement.
Software programmable measurement range settings.
5-point calibration for Temperature.
5-point calibration for RH.
High input impedance.
Software calibration – No trim pots.
PC programmable.
Operating Voltage
24VDC.
Enclosure
ABS IP65.
Sensor Tube
SS304.
Filter
Sintered bronze.
Protection
IP65 except sensor tube.
Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
the “styrax” surgeon control panels (scp), sometimes called theatre control panels (tcp) or operating room control panels, are the central focus for infrastructure controls as well as alarms and information required in an operating room. This focus has two main benefits it allows the users to only have one familiar source of information and lets the facilities staff easily inspect and maintain several different subsystems, without disrupting the wall infection integrity.
features :
stopwatch timer.
real time clock.
temperature, rh and differential pressure display unit with in-built.
integral sensor.
differential pressure display unit with integral in-built sensor.
medical gas alarm system.
hands free telephone.
ot control switches.
wall or modular mounting.
ss-304 faceplate and ms powder coating backside box.
the “styrax” surgeon control panels (scp), sometimes called theatre control panels (tcp) or operating room control panels, are the central focus for infrastructure controls as well as alarms and information required in an operating room. This focus has two main benefits it allows the users to only have one familiar source of information and lets the facilities staff easily inspect and maintain several different subsystems, without disrupting the wall infection integrity.
features :
stopwatch timer.
real time clock.
temperature, rh and differential pressure display unit with in-built.
integral sensor.
differential pressure display unit with integral in-built sensor.
medical gas alarm system.
hands free telephone.
ot control switches.
wall or modular mounting.
ss-304 faceplate and ms powder coating backside box.
styrax manufactures stop watch timer and clock. These clocks are especially designed to know lapsed time interval of process. Timer can be start, stop and reset by using front panel soft-touch membrane keypad. These stop watch timer display clock in 24hrs format and this can be synchronized with wired master clock through rs485.
4 digit 7 segment 0.8" led display to display hours and minutes.
2 digit 7 segment 0.56" led display to display seconds
soft touch key pad to start/stop/reset stop watch timer
user can change over from stop watch to clock mode
styrax manufactures stop watch timer and clock. These clocks are especially designed to know lapsed time interval of process. Timer can be start, stop and reset by using front panel soft-touch membrane keypad. These stop watch timer display clock in 24hrs format and this can be synchronized with wired master clock through rs485.
4 digit 7 segment 0.8" led display to display hours and minutes.
2 digit 7 segment 0.56" led display to display seconds
soft touch key pad to start/stop/reset stop watch timer
user can change over from stop watch to clock mode
We are offering staticpass box interlocking system.
Description: pass box is used for material transfer from one clean room to another clean room. It consists of a
rectangular box with two doors. The two doors are interlocked such that two doors cannot be open at the same
time, to prevent pressure losses and cross contamination.
our pass box controller achieve this by preventing simultaneous access of door by ensuring that when one
door for a pass box is open then other door is closed.
Before opening of door.
1. When door 1 is opened the display on the door 2 will indicate “wait” and at the door 1 the display will
indicate “door open”
2. When any of the door is kept open beyond a particular time say 10 min, a buzzer will be blown and the
display at the doors will indicate “close door”
3. When any door is opened the cf lamp is switched on, and the uv lamp will be switched off
4. Both doors are provided with em locks
2. Features:
• advanced micro controller based.
• supports maximum of 2 doors
• supports electromagnetic lockselectric strikers
• door status indication with high intensity bar leds
• status indication: go, wait, door open, close door
• buzzer output for door is kept open more than specified time from 2 to 30 min.
• uv lamp controlling
o uv lamp on for both doors closed
o uv lamp off for both doors open
3. Specifications:
general
electromagnetic lock source : 24v dc 250 ma
door control by relay:
relays:
contact material : silver alloy.
contact rating : 230v ac 2 a.
no. Of operations : mechanical : 107 , electrical : 105.
enclosure:
pass box controller
enclosure type : power coating box
mounting : on service area
display module
enclosure type : ss-316l
mounting : panel
power supply:
power : 80 - 280v, ac 50 hz
wattage : 50w
environmental:
operating temperature : 0 to 500c.
4. Electromagnetic locks:
a magnetic lock is a simple locking device that consists of an electromagnet and armature plate. By attaching the electromagnet to the door frame and the armature plate to the door, a current passing through the electromagnet attracts the armature plate holding the door shut .the magnetic lock relies upon some of the basic concepts of
electromagnetism. Essentially it consists of an electromagnet attracting a conductor with a force sufficiently large enough to prevent the door from being opened.
5. Status indication on display panel :
go = indicate that person can access the door.
Wait = indicate that person cannot access the door.
Door open = indicate door is opened
close door = indicates that the door is opened more than specified time.
We are offering staticpass box interlocking system.
Description: pass box is used for material transfer from one clean room to another clean room. It consists of a
rectangular box with two doors. The two doors are interlocked such that two doors cannot be open at the same
time, to prevent pressure losses and cross contamination.
our pass box controller achieve this by preventing simultaneous access of door by ensuring that when one
door for a pass box is open then other door is closed.
Before opening of door.
1. When door 1 is opened the display on the door 2 will indicate “wait” and at the door 1 the display will
indicate “door open”
2. When any of the door is kept open beyond a particular time say 10 min, a buzzer will be blown and the
display at the doors will indicate “close door”
3. When any door is opened the cf lamp is switched on, and the uv lamp will be switched off
4. Both doors are provided with em locks
2. Features:
• advanced micro controller based.
• supports maximum of 2 doors
• supports electromagnetic lockselectric strikers
• door status indication with high intensity bar leds
• status indication: go, wait, door open, close door
• buzzer output for door is kept open more than specified time from 2 to 30 min.
• uv lamp controlling
o uv lamp on for both doors closed
o uv lamp off for both doors open
3. Specifications:
general
electromagnetic lock source : 24v dc 250 ma
door control by relay:
relays:
contact material : silver alloy.
contact rating : 230v ac 2 a.
no. Of operations : mechanical : 107 , electrical : 105.
enclosure:
pass box controller
enclosure type : power coating box
mounting : on service area
display module
enclosure type : ss-316l
mounting : panel
power supply:
power : 80 - 280v, ac 50 hz
wattage : 50w
environmental:
operating temperature : 0 to 500c.
4. Electromagnetic locks:
a magnetic lock is a simple locking device that consists of an electromagnet and armature plate. By attaching the electromagnet to the door frame and the armature plate to the door, a current passing through the electromagnet attracts the armature plate holding the door shut .the magnetic lock relies upon some of the basic concepts of
electromagnetism. Essentially it consists of an electromagnet attracting a conductor with a force sufficiently large enough to prevent the door from being opened.
5. Status indication on display panel :
go = indicate that person can access the door.
Wait = indicate that person cannot access the door.
Door open = indicate door is opened
close door = indicates that the door is opened more than specified time.
FeaturesAdvanced Microcontroller based process measurement. , High input impedance.
RHCapacitive sensor.
TemperatureSemiconductor (Band gap) sensor.
The STYRAX “Temperature and RH Transmitter” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. RHT105 is a high-performance 4-wired Relative Humidity and Temperature Transmitter. Its relative humidity and temperature transmitter is available in surface mount, duct mount and remote sensor versions. This transmitter is accurate to 1.5% for relative humidity and within 0.3 °C for temperature. RHT105 transmits two isolated output signals to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. The RH+T transmitter is user programmable by a PC, connected via Configuration software by STYRAX.
The STYRAX “Temperature and RH Transmitter” has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. RHT105 is a high-performance 4-wired Relative Humidity and Temperature Transmitter. Its relative humidity and temperature transmitter is available in surface mount, duct mount and remote sensor versions. This transmitter is accurate to 1.5% for relative humidity and within 0.3 °C for temperature. RHT105 transmits two isolated output signals to other devices such as a Programmable Logic Controller (PLC) or Solid-State Relay (SSR). Signal isolation protects your devices and machines downstream of our instruments from damaging fluctuations in the input signal. The RH+T transmitter is user programmable by a PC, connected via Configuration software by STYRAX.
a public address system (pa system) is an electronic sound amplification and distribution system with a microphone, amplifier and loudspeakers, used to allow a person to address a large public, for example for announcements of movements at large and noisy air and rail terminals or at a sports stadium. These systems which may additionally have a mixing console, and amplifiers and loudspeakers suitable for music as well as speech, used to reinforce a sound source, such as recorded music or a person giving a speech or distributing the sound throughout a venue or building.
a public address system (pa system) is an electronic sound amplification and distribution system with a microphone, amplifier and loudspeakers, used to allow a person to address a large public, for example for announcements of movements at large and noisy air and rail terminals or at a sports stadium. These systems which may additionally have a mixing console, and amplifiers and loudspeakers suitable for music as well as speech, used to reinforce a sound source, such as recorded music or a person giving a speech or distributing the sound throughout a venue or building.
Analog OutputNon-isolated - fixed range 0-14 pH = 4-20mA
a ph meter is an instrument used to measure acidity or alkalinity of a solution - also know as ph. Ph is the unit of measure that describes the degree of acidity or alkalinity. It is measured on a scale of 0 to 14.
the quantitative information provided by the ph value expresses the degree of the activity of an acid or base in terms of hydrogen ion activity. The ph value of a substance is directly related to the ratio of the hydrogen ion [h+] and the hydroxyl ion [oh-] concentrations. If the h+ concentration is greater than oh-, the material is acidic; i.e., the ph value is less than 7. If the oh- concentration is greater than h+, the material is basic, with a ph value greater than 7. If equal amounts of h+ and oh- ions are present, the material is neutral, with a ph of 7. Acids and bases have free hydrogen and hydroxyl ions, respectively. The relationship between hydrogen ions and hydroxyl ions in a given solution is constant for a given set of conditions, either one can be determined by knowing the other.
styrax manufactures micro processor based ph meter is an economical, user-friendly panel meter for ph measurement. Its small size allows for easy installation and will accommodate any ph electrode with bnc connector. Temperature compensation is either manual or automatic with use of any 1000ω platinum rtd.
emp. Compensation
manual fixed resistors; automatic 1000 ω rtd
display
4 digit, red led, 14.2 mm h (0.56")
display range
0 to 14 ph
connections
bnc
power requirements
voltage: 115 vac ±15% standard (230 vac or 10 to 32 vdc optional)
frequency:50 or 60 hz
power consumption
2.5 watts max.
a ph meter is an instrument used to measure acidity or alkalinity of a solution - also know as ph. Ph is the unit of measure that describes the degree of acidity or alkalinity. It is measured on a scale of 0 to 14.
the quantitative information provided by the ph value expresses the degree of the activity of an acid or base in terms of hydrogen ion activity. The ph value of a substance is directly related to the ratio of the hydrogen ion [h+] and the hydroxyl ion [oh-] concentrations. If the h+ concentration is greater than oh-, the material is acidic; i.e., the ph value is less than 7. If the oh- concentration is greater than h+, the material is basic, with a ph value greater than 7. If equal amounts of h+ and oh- ions are present, the material is neutral, with a ph of 7. Acids and bases have free hydrogen and hydroxyl ions, respectively. The relationship between hydrogen ions and hydroxyl ions in a given solution is constant for a given set of conditions, either one can be determined by knowing the other.
styrax manufactures micro processor based ph meter is an economical, user-friendly panel meter for ph measurement. Its small size allows for easy installation and will accommodate any ph electrode with bnc connector. Temperature compensation is either manual or automatic with use of any 1000ω platinum rtd.
emp. Compensation
manual fixed resistors; automatic 1000 ω rtd
display
4 digit, red led, 14.2 mm h (0.56")
display range
0 to 14 ph
connections
bnc
power requirements
voltage: 115 vac ±15% standard (230 vac or 10 to 32 vdc optional)
frequency:50 or 60 hz
power consumption
2.5 watts max.
in the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our pass box controller by ensuring that when one door for a pass box is open then other doors closed.
features:
advanced micro controller based 2door or 3door static/dynamic passbox interlocking system.
status indications with high intensity red color bar led's.
door status indications like “go”, ”wait”, “close door”, “door open” messages or “locked”, “released” for every pushbutton.
buzzer output for door is kept open more than pre-programmed time from 1 to 30 min.
timer value can set by using 3keys keypad.
password protection for timer value setting.
timer value can set maximum of 999 sec/mins.
when door 1 is opened the display on the door 2 and door 3 will indicate “wait” and at the door 1 the display will indicate “door open”.
when any of the door is kept open beyond a particular time say 2 min, buzzer will be blown and the display at the doors will indicate “close door”.
uv lamp controlling.
blower fan controlling.
cf lamp controlling.
all doors are provided with electromagnetic locks/electric strikers.
3 digit 0.39” 7-segment red led to display the timer value.
soft-touch membrane keypad provided to program timer values.
3mm diffused red led for blower failure indications.
soft-touch membrane keypad provided to program timer value.
soft-touch membrane keypad provided to control laf/buf controls.
3mm diffused bi-color led indication to display on/off status of uv,cf, blower.
door delay time: pre programmed as per the requirement.
specifications:
mode of operation: nc or no.
pushbutton inputs based on doors max up to 3 doors.
door feedback inputs based on doors max up to 3 doors.
door control outputs based on doors max up to 3 doors.
led indications for push buttons: go/wait.
in the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our pass box controller by ensuring that when one door for a pass box is open then other doors closed.
features:
advanced micro controller based 2door or 3door static/dynamic passbox interlocking system.
status indications with high intensity red color bar led's.
door status indications like “go”, ”wait”, “close door”, “door open” messages or “locked”, “released” for every pushbutton.
buzzer output for door is kept open more than pre-programmed time from 1 to 30 min.
timer value can set by using 3keys keypad.
password protection for timer value setting.
timer value can set maximum of 999 sec/mins.
when door 1 is opened the display on the door 2 and door 3 will indicate “wait” and at the door 1 the display will indicate “door open”.
when any of the door is kept open beyond a particular time say 2 min, buzzer will be blown and the display at the doors will indicate “close door”.
uv lamp controlling.
blower fan controlling.
cf lamp controlling.
all doors are provided with electromagnetic locks/electric strikers.
3 digit 0.39” 7-segment red led to display the timer value.
soft-touch membrane keypad provided to program timer values.
3mm diffused red led for blower failure indications.
soft-touch membrane keypad provided to program timer value.
soft-touch membrane keypad provided to control laf/buf controls.
3mm diffused bi-color led indication to display on/off status of uv,cf, blower.
door delay time: pre programmed as per the requirement.
specifications:
mode of operation: nc or no.
pushbutton inputs based on doors max up to 3 doors.
door feedback inputs based on doors max up to 3 doors.
door control outputs based on doors max up to 3 doors.
led indications for push buttons: go/wait.
FeaturesTimer value can set by using 3keys keypad. and Password protection for Timer value setting.
Contact Material:Silver Alloy.
Contact Rating:230V AC / 2 A.
Mechanical107
Electrical105.
Input Voltage24Watt at 80-280VAC, 50Hz.
Operating Voltage12V / 24V DC.
In the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our Pass Box controller by ensuring that when one door for a Pass box is open then other doors closed.
In the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our Pass Box controller by ensuring that when one door for a Pass box is open then other doors closed.
No. of Channels2/4/6/8/12/16 channels with 4-digit 2” 7-Segment LED.
Input TypeRTD /4-20mA/0-10VDC
Measuring Ranges-199.9 to 999.9.
the styrax “multi channel indicator” has been specially developed keeping process measurement requirements of pharmaceutical industries. The multi channel indicator can measure temperature sensor (pt100) or 4-20ma or 0-10vdc. Configurable set points for pfc outputs. Display measured values data transfers to any master device on modbus rs-485 communication. It has keypad to program and calibrate the instrument by user. It has ms powder wall mounting enclosure.
features :
advanced microcontroller based process measurement.
software programmable channel ranges and unit.
programmable resolution.
4 digit, 2.0” bright 7- segment led display.
unit's display using high brightness led's.
user selectable set limits for process value violation.
inbuilt buzzer to audible process value violation.
configurable set limit for potential free contact.
configurable hysteresis for pfc set point.
pfc outputs for all channels.
password protection for calibration and programming mode.
software calibration for all channels.
modbus rtu multi drop rs-485 serial communication for plc, scada, etc.
programmable baud rate between 9.6k/19.2k/38.4k.
user programmable offset correction.
wall mounting.
ms powder coated enclosure.
the styrax “multi channel indicator” has been specially developed keeping process measurement requirements of pharmaceutical industries. The multi channel indicator can measure temperature sensor (pt100) or 4-20ma or 0-10vdc. Configurable set points for pfc outputs. Display measured values data transfers to any master device on modbus rs-485 communication. It has keypad to program and calibrate the instrument by user. It has ms powder wall mounting enclosure.
features :
advanced microcontroller based process measurement.
software programmable channel ranges and unit.
programmable resolution.
4 digit, 2.0” bright 7- segment led display.
unit's display using high brightness led's.
user selectable set limits for process value violation.
inbuilt buzzer to audible process value violation.
configurable set limit for potential free contact.
configurable hysteresis for pfc set point.
pfc outputs for all channels.
password protection for calibration and programming mode.
software calibration for all channels.
modbus rtu multi drop rs-485 serial communication for plc, scada, etc.
programmable baud rate between 9.6k/19.2k/38.4k.
user programmable offset correction.
wall mounting.
ms powder coated enclosure.
Blower Relay O/P230V AC / 2 A (up to 1HP Blower can be connected).
UV Lamp Relay O/P230V AC / 2 A.
CF Lamp Relay O/P230V AC / 2 A.
No. of blower failure indications5.
buf on/off controller is used for on/off controlling of blower, uv lamp & cf lamp in dynamic pass boxes, bio safety cabinets and laminar air flow. The status of blower, uv lamp & cf lamp is provided on display.
features :
advanced micro controller based.
on/off message display.
relay o/p for blower (up to 1 hp), uv lamp & cf lamp.
on/off massage status indication with high intensity bar leds.
status indication: on, off-blower, on, off- uv lamp & on, off – cf lamp.
blower failure status indications.
soft touch membrane key pad.
easy for installation.
relay specifications
contact material: silver alloy.contact rating: 230v ac / 2 a.no. Of operationsmechanical: 107electrical: 105.
enclosure
ms powder coated for controller unit ss-316 face plate for dpm.
mounting
panel.
power
100 - 260v, ac 50 hz.
dpm dimensions
150mm l x 91mm w x 29mm d.
buf on/off controller is used for on/off controlling of blower, uv lamp & cf lamp in dynamic pass boxes, bio safety cabinets and laminar air flow. The status of blower, uv lamp & cf lamp is provided on display.
features :
advanced micro controller based.
on/off message display.
relay o/p for blower (up to 1 hp), uv lamp & cf lamp.
on/off massage status indication with high intensity bar leds.
status indication: on, off-blower, on, off- uv lamp & on, off – cf lamp.
blower failure status indications.
soft touch membrane key pad.
easy for installation.
relay specifications
contact material: silver alloy.contact rating: 230v ac / 2 a.no. Of operationsmechanical: 107electrical: 105.
enclosure
ms powder coated for controller unit ss-316 face plate for dpm.
mounting
panel.
power
100 - 260v, ac 50 hz.
dpm dimensions
150mm l x 91mm w x 29mm d.
SpecialitiesReliable LED display , High readability and Synchronizes Slaves Every Second
ApplicationsPharmacy industry. , Blood stations, pharmacies. and Horticultural and cultivation of plants
STYRAX manufacturers’ digital synchronized master clock systems, and other LED clocks. All clocks can display the same, accurate, legal time. STYRAX commercial digital clocks are specifically designed for applications where precision and reliability are of utmost importance. These clocks may be used as accurate stand-alone time displays. They can also be synchronized so that all clocks display the same time. SDC105M clock synchronizes the Slave Clocks (i.e.SDC1051S, SDC1052S) every second within the RS485 network.
STYRAX manufacturers’ digital synchronized master clock systems, and other LED clocks. All clocks can display the same, accurate, legal time. STYRAX commercial digital clocks are specifically designed for applications where precision and reliability are of utmost importance. These clocks may be used as accurate stand-alone time displays. They can also be synchronized so that all clocks display the same time. SDC105M clock synchronizes the Slave Clocks (i.e.SDC1051S, SDC1052S) every second within the RS485 network.
Specialities : Reliable LED display , High readability and Synchronizes Slaves Every Second
Styrax wireless synchronized master clock system operates on a very basic concept. The Master clock acquires the time and then transmits it wirelessly to the slave clocks that are in the system. Once the transmitter master clock receives a time update, it then transmits the time to any number of secondary slave digital clocks. The digital clocks need only a 240v ac power outlet; they include their own internal battery pack with 5 year life.
Styrax wireless synchronized master clock system operates on a very basic concept. The Master clock acquires the time and then transmits it wirelessly to the slave clocks that are in the system. Once the transmitter master clock receives a time update, it then transmits the time to any number of secondary slave digital clocks. The digital clocks need only a 240v ac power outlet; they include their own internal battery pack with 5 year life.
Styrax manufactures Gang man alarm system, this system used as siren to alert people who are working in particular area as per predefine set time intervals. This clock synchronized with wired master clock through RS485 to maintain clock with zero error. These clock displays time in 24Hrs format. Manual override and Manual ON/OFF pushbuttons are provided to control siren on demand basis.
4 digit 7 segment 2” LED display to display Hours and Minutes.
Styrax manufactures Gang man alarm system, this system used as siren to alert people who are working in particular area as per predefine set time intervals. This clock synchronized with wired master clock through RS485 to maintain clock with zero error. These clock displays time in 24Hrs format. Manual override and Manual ON/OFF pushbuttons are provided to control siren on demand basis.
4 digit 7 segment 2” LED display to display Hours and Minutes.
Styrax manufactures micro controller based Flow controller used to Turn OFF motors in dry run condition. By using this flow controller user can prevent motor failure due to motor dry run.
Styrax manufactures micro controller based Flow controller used to Turn OFF motors in dry run condition. By using this flow controller user can prevent motor failure due to motor dry run.
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.