3/4 MCB Box Plate
12 - 13 Per piece
10000 Pieces (MOQ)
ABB Air Circuit Breaker
Get Price Quote
SACE Emax 2 is a series of low voltage air circuit-breakers up to 6300 A. The SACE Emax 2 range is made up of 4 sizes: E1.2, E2.2, E4.2 and E6.2 up to 6300A. E1.2 offers 1,600A with breaking capacity up to 66kA and withstand current of 50kA. E1.2 offers 1,600A with breaking capacity up to 66kA and withstand current of 50kA. E4.2 is the new 4,000A circuit-breaker designed with a withstand rating of 100kA. E6.2, with an interrupting rating of 200kA and a structure that allows 6,300A to be reached.
Best Deals from Circuit Breaker
Mixer Grinder Circuit Breaker
Get Price Quote
We are an eminent Mixer Grinder Circuit Breakers Supplier. We hold considerable experience in the industry and offer a wide range of high quality Circuit Breakers (CB) of Mixer Grinders. The Circuit Breakers Of Mixer Grinders available with us are made from preeminent quality material. Available in variety of specifications and sizes, our Circuit Breakers (CB) of Mixer Grinders match the requirements of different customers easily. The Mixer Grinder Circuit Breakers provided by us are of compact size and have accurate dimensions. We can easily handle the bulk order requirements of the customers too! Features : Compact size Excellent performance Accurate Dimensionally Superior service life
Indoor VCB Panel
Get Price Quote
Separately lockable shutters for bus and cable side. Access to cable terminals from rear. Guaranteed voltage withstand without conductor insulation .Top lifting arrangement for panel. Conforms to IEC Standard. The breaker cannot be moved from test to service position unless the breaker compartment door is closed The breaker cannot be moved from test to service position or vice versa with breaker in closed condition. The breaker cannot be closed in-between test and service position. The breaker compartment door cannot be opened when the breaker is in service position or in between service & test positions.
Rocker Switches
Get Price Quote
ESE Lightning Arrester
75,000 Per Piece
Change Over Switch and Door Bells
Get Price Quote
We are offering change over switch and door bells.
POE switch
21,199 Per Piece
05 Piece (MOQ)
Circuit Breaker
Get Price Quote
A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and interrupt current flow. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation. Circuit breakers are made in varying sizes, from small devices that protect an individual household appliance up to large switchgear designed to protect high voltage circuits feeding an entire city.
Rotary Switches
100 - 1,000 Per Each
We can supply from 1 P to 18 way and in each pole 2 way to 24 ways. Please let us know no. of Poles and No. of ways.
Thermal Overload Relays
Get Price Quote
Range : Type PK -1 : Various ratings from 2.5 A=4A to 9A-14 A Type PC -1 : Various ratings from 1 A= 1.6 A to 11A-18A Type PC-23 : Various ratings from 9 A= 14A to 28A-42 A Salient Features * ISI Marked Power Contactors * Trip class : 10A * Suitable for direct mounting on contactors * Manual reset type * Satisfactory operation at all ambient temperature from -5 °C to 55 °C
Lightning Arrestors
Get Price Quote
Lightning Arrestors is a 'Voltage Relief Valve' which remain closed until voltage on the system rises to the level which causes values to open.
6 Ways Spike Suppressor with Individual Switch
Get Price Quote
We offer 6 way spike suppressor with individual switch available in 1.503.005.00 mtr.lenght in grey &white colour.
Slide Switches
Get Price Quote
Slide Switches, door switches, Toggle Switches, miniature switches
Molded Case Circuit Breakers
3,000 Per Piece
electrical mcb switch
Get Price Quote
Rotary Switches
Get Price Quote
Magnetic Proximity Switch
Get Price Quote
magnetic proximity switch * M18 cylindrical photoelectric sensors * Diffuse reflective * Retro reflective * Thru beam emitter receiver * Models with cable or connector arrangement
Aerial Rod
Get Price Quote
We are offering aerial rod, multiple point, terminal base. lightning rod a lightning rod as spelled in us and australia or lightning conductor in uk is a metal rod or metallic object mounted on top of a building, electrically bonded using a wire or electrical conductor to interface with ground earth through an electrode, engineered to protect the building in the event of lightning strike. If lightning targets the building it will preferentially strike the rod and be conducted to ground through the wire instead of passing through the building where it could start a fire or cause electrocution. a lightning rod is a single component in a lightning protection system. Lightning rods are also called air terminals or strike termination devices. The lighting rod requires a connection to earth to perform its protective function. Lightning rods come in many different forms, including hollow, solid, pointed, rounded, flat strips or even bristle brush-like: copper or aluminium. The main attribute of all lightning rods is they are conductive. lightning protection systems a lightning protection system is designed to protect a structure from damage due to lightning strikes by intercepting such strikes and safely passing their extremely high voltage currents to the ground earth. A lightning protection system includes a network of air terminals, bonding conductors, and ground electrodes which are designed to provide a low impedance path to ground for potential strikes. lightning protection systems are used to prevent or lessen damage to structures done by lightning strikes. It mitigates the fire hazard which lightning strikes pose to structures. A lightning protection system provides a low-impedance path for the lightning current to lessen the heating effect of current flowing through flammable structural materials. If lightning travels through porous and water-saturated materials,these parts of a building may literally explode if their water content is flashed to steam by heat produced from lightning current. because of the high energy and current levels associated with lightning ,currents can be in excess of 150,000 amps and the very rapid rise time of a lightning strike, no lightning protection system can guarantee absolute safety from lightning. Lightning current will divide to follow every conductive path to ground, and even the divided current can cause damage. Secondary "side-flashes" can be enough to ignite a fire, blow apart brick, stone, or concrete, or injure occupants within a structure or building. However, the benefits of basic lightning protection systems have been evident for well over a century. the parts of a lightning protection system are air terminals lightning rods or strike termination devices, bonding conductors, ground terminals also known as ‘’ground’ or "earthing" rods, plates, or mesh), and all of the connectors and supports to complete the system. The air terminals are typically arranged at or along the upper points of a roof structure, and are electrically bonded together by bonding conductors (called "down conductors" or "down leads"), which are connected by the most direct route to one or more grounding or earthing terminals. connections to the earth electrodes must not only have low resistance, but must have low self-inductance. An example of a structure vulnerable to lightning is a wooden barn. When lightning strikes the barn, the wooden structure and its contents, may be ignited by the heat generated by lightning current conducted through parts of the structure. A basic lightning protection system would provide a conductive path between an air terminal and earth, so that most of the lightning's current will follow the path of the lightning protection system, with substantially less current travelling through flammable materials. the majority of lightning protection systems in use today are of the traditional franklin design. The fundamental principle used in franklin-type lightning protections systems is to provide a sufficiently low impedance path for the lightning so that it travels through to reach ground without damaging the building. This is accomplished by surrounding the building in a kind of faraday cage. A system of lightning protection conductors and lightning rods are installed on the roof of the building to intercept any lightning before it strikes the building.
Electrical Circuit Breaker
Get Price Quote
mcbs
Get Price Quote
Current limiting design for short circuit fault clearance upto 10KA. Silver graphic contact ensuring maximum safety against contact welding. 15 plate Arc splitter assembly for quick arc splitting and extinguishing. Finger prool terminal protecting against accidental contact with live part. Lower terminal designed to accomodate cable or bus bar.
High Voltage Power Cable
Get Price Quote
Extra High Voltage (EHV) power cable is a major back bone of the electric system. The reliability and safety of the electric power transmission system essentially depend upon the quality of the cable. Traditionally Paper Oil Insulation systems have been used in High voltage transmission cables. However, since the advent of synthetic polymer, polyethylene (PE) and cross-linked polyethylene (XLPE) have been used as an insulation material. In most countries the use of polyethylene have been limited to the cross-linked version (XLPE) due to major advantage XLPE has over PE in that it enables the cables to be operated at a higher temperature and results in higher current carrying capacity. Cross-linked polyethylene is also considered to be the material of choice due to its ease of processing and handling as compared to paperoil. In addition, the low dielectric losses of cross-linked polyethylene which become increasingly important with increase in voltage as well as high intrinsic electrical strength makes it the favored material for the range of extra-high-voltage applications. These cables can be designed to meet requirements of international standards such as IEC, ICEA, UL, DIN, VDE, ASNZS, TIS, IS as well as other standards specified by customers.
Air Break Switch
Get Price Quote
We are manufacturing and offering 11 kv g.o air break switch with triple pole. Each pole consists of galvanized steel base, h.t insulator & spring loaded contact. It has a section to break magnetizing current of transformer horizontal g.i. Pipe 01 adequate length of g.i pipes for operation from ground and operating handle complete in both on & off position. Technical specification: rated voltage : 12kv rated current : 400a frequency : 50hz impulse withstand voltage (+ve) : 77kvp impulses withstand voltage (-ve) : 76kvp also available in 1122kv air break switch.
MCCB
Get Price Quote
80 gsm A4 printer paper, industrial electrical cables
Gear
Get Price Quote
Gear, break
Lightning Protection System
Get Price Quote
Electrical Cable Tray, Networking Products, steel ladder cable trays
Mcb
Get Price Quote
Buzzer, Fan Regulator, Dimmer, Blank Plate, Computer Jack, Telephone
Electric Switches
Get Price Quote
Electric Switches, electric wires, Gearboxes
Electrical Switches
Get Price Quote
Electrical Switches, Electrical Goods, Enclosures, flame proof equipment
switches gears
Get Price Quote
switches gears, Wires, Cables, Fans