Heat Detector Tester Portable Fire Alarm Testing Tool IMPA 331071
Get Price Quote
1 piece (MOQ)
Heat Detector Tester – Marine Type 331071 🔍 Key Features & Benefits 🌡️ Simulates Heat Activation Conditions – Triggers heat detectors to verify alarm responsiveness and system integrity. ⚙️ Safe & Controlled Heat Source – Applies warm airflow without damaging sensitive detector components. 🔋 Battery or Mains Operated (Model Dependent) – Portable and convenient for onboard testing routines. 🔧 Compatible with Most Heat Detector Types – Designed to fit standard fixed-temperature and rate-of-rise models. 🧯 Ideal for Periodic Fire System Testing – Ensures ship compliance with SOLAS, Class, and safety protocols. ✅ Marine Safety Approved Tool – Used by ship electricians, safety officers, and port authorities. 🧭 Ideal Applications Routine testing of heat detectors in fire detection systems Onboard fire drill and alarm maintenance operations Inspection checks during safety audits and surveys Pre-departure fire system compliance validation Portside and drydock servicing of vessel safety systems 🏗️ Key Areas of Use Commercial Ships, Ferries & Passenger Vessels Offshore Rigs & Floating Installations Marine Safety Departments & Surveyors Ship Repair & Electrical Workshops Fire System Inspection & Certification Agencies
UV Flame Detector
Get Price Quote
A highly sensitive instrument to detect flames electric spark, tire in environments where catastrophic consequences could result from unwanted fire. It is particularly suitable for use in outdoor applications because it is not affected by wind or rain and is insensitive to solar radiation. Various models to detect
Best Deals from Fire Detectors
Fire Safety Detectors
Get Price Quote
Aftech is counted among dependable Exporters and Suppliers of Fire Safety Detectors. We are engaged in offering a variety of Fire Safety Detectors to ensure complete safety at home, office, factory, hospital etc. All the Fire Safety Detectors, we offer, are procured from trusted market leaders who manufacture these products with intense R&D work. Our Fire Safety Detectors provide flawless safety. We offer Fire Safety Detectors at very reasonable price.
Conventional Fire Detectors
700 Per Piece
Features of Conventional Fire Detectors : Conventional Fire Detectors has Micro- controller based. Availability of 2/4/6/8/10/12/14/16 zone panels. Multiple zones programmable as delay, immediate, panic or fire. Two individual user codes - master and servant. Onboard or separate key pad. Can attach up to five additional remote key pads. Automatic arming and disarming.
Brahma Flame Detector
Get Price Quote
We are offering brahma uv cell uv1 brahma uv cell uv1 for gas burners, brahma flame detector uv1, brahma photocell uv1, brahma flame sensor uv1.
Flame Detector
Get Price Quote
Clients can rely on us for meticulous packaging of the products. And, for attaining this objective, we have hired a team of professionals who make use of premium material and modern packaging tools for doing the same. We have garnered wide acclaim for bringing forth cost-effective product range that is available at Mumbai(India).
Fire Detector
Get Price Quote
We specialize in supplying and providing services for our wide range of qualitative fire detectors. These are procured from certified and reputed manufacturers. Our range of fire detectors is available with following technical and general specifications : Light test feature makes testing easy with a flashlight beam 85 dB alarm Two 9-volt batteries included 5 year limited warranty
Flame Fire Detector
Get Price Quote
We are the leading supplier of this products.
UV Flame Detector
Get Price Quote
The HNL Flame Detector is a compact and highly responsive Flame / Fire Detector. The Unit incorporates an extremely sensitive sensing circuit that responds to high energy sources in a bandwidth of 185 – 260 nm with optimum spectral sensitivity centred around 200 nm.Thus HNL Flame Detector is the most effective in early detection of a fire before they can possibly cause damage. In contrast, other types of detectors operate at a disadvantage. Smoke detectors do not operate until the fire has developed into a sufficient size to accelerate smoke along with strata of hot air rising to the detector.It is particularly suitable for use in outdoor applications because it is not affected by wind or rain. Various modelsto detect & control the presence or absence of flame are available.
Ultraviolet Flame Detectors
Get Price Quote
1 Piece (MOQ)
Fire Alarm Detector
2,500 Per Piece
1 Piece(s) (MOQ)
5 MSIR Flame Detector
Get Price Quote
The Ultima Controller is purpose-designed and built to provide complete access to all advanced features of the Ultima and Ultima X Gas Monitors, as well as the Toxgard II Gas Monitor. Via its full-function and password-protected keypad, users can set the real time clock, set alarm levels, change span-gas values, display date of last calibration, display minimum, maximum and average gas values, change address and set future calibration time/date in addition to providing basic calibration functions Multi-Spectrum IR (MSIR) sensor array provides increased range and a wide field of view Neural Network Technology (NNT) combination is highly immune to false alarms caused by lightning, arc-welding, hot objects, and other sources of radiation. Continuous Optical Path Monitoring (COPM) checks the optical path integrity and the detector's electronic circuitry Designed to detect typical fires such as those produced by alcohol, n-heptane, gasoline, jet fuels and hydrocarbons, the FlameGard 5 MSIR Detector can see through dense smoke produced by diesel, rubber, plastics, lube oil, and crude oil fires. The FlameGard 5 MSIR Detector is housed in a stainless steel explosion-proof enclosure to provide operational integrity in the harshest environments. Multiple communication outputs provide versatility for use in a variety of applications The serial communication port(s) allows 128 units (247 using repeaters) to be linked up to a host computer using the Modbus RTU protocol.
Fire Detector
Get Price Quote
The IR/UV Based Fire Detector easily detects fire by detecting its three critical features such as IR emission from the hot CO2, UV radiation (185 mm to 260 mm) in the area surrounding the solar bind and continuum black body generated by IR radiation emanating from fire. Having a flameproof enclosure (with two windows), the Fire Detector can be easily mounted on a wall with the help of a stand; this stand’s view can be adjusted for bringing the viewing window in the line of sight of the spot where fire outbreaks can happen.Working : The detector gives a "fire alarm" (red led glows) when all the three chosen fire parameters are detected. Simultaneously a relay output is available. When only one of IR or UV radiation is detected yellow led glows to give a "warn alarm" and also a relay output is available. The detector also provides an analog 4-20mA output and MODBUS RS485 digital output to indicate the above events. Features Multi-parameter based Detector for avoiding false alarm Wall mountable with adjustable cone of view 4-20 mA analog output Alarm, Warn and Fault indications by LEDs and relay outputs MODBUS RS485 digital output Applications Automotive Industries Industrial heating and drying systems Industrial gas turbines Flammable material storage facilities Refineries Drilling and production platforms Fuel loading facilities Compressor stations/Gas compressors Electrostatic plant spray booths LNG / LPG processing and storage facilities Chemical plants Aircraft hangars Spectral Sensitivity : UV : 185 - 260 nm IR1 : 3.9 microns IR2 : 4.4 microns Relay Output : Fire Alarm : SPDT - Normally De-Energized, Latching/ Non- Latching Warn Alarm : SPDT - Normally De-Energized, Latching/ Non- Latching Fault Alarm : SPST - Normally Energized, Latching/ Non-Latching Relay Contact Rating : 1 amp @ 24 VDC Analog Output : 4-20 mA Visual indications : Green LED : Power on Yellow LED : Warn Red LED : Fire Digital Output : RS-485 MODBUS protocol Temperature Range : Operating : -10 to +50 C Conduit Entries : Standard 3 no. of 1/2" NPT Enclosure Materials : Copper free Aluminum alloy - Powder coated Enclosure Type : Explosion Proof Certifications : Ex-d IIC IP66, T6.
Flame Detectors
Get Price Quote
We are offering flame detectors. Pes-ir/uv flame detector of jsc “electronstandart-pribor” we offer provides superior sensitivity for a wide range of fire types including fires from oil, petrochemical products and metal. The sophisticated combination of multiple sensors and wavelength range settings, enables the flame detector to detect those characteristic wavelength emissions from the uv-to-ir spectrum that indicate actual flame or fire. features automatic and manual self-tests ensure system integrity and correct operationcontinuous monitoring of optical path for obstruction or reduced transmissionindustry standard for remote alarm and fault indication ensures reliability and consistencydigital, analog and relay outputs provide reliable status information across a range of formatscolor status led for easy viewing of operating statuspower consumption of.
Fire Detectors
Get Price Quote
Fire detectors the fuel and ignition; the Fire Triangle is effectively broken. Hence, the fire stops immediately. However,
Flame Detectors
Get Price Quote
UV Flame Detector
Get Price Quote
This test unit has been designed to generate a wide range of optical output signals. Flame sensors for fire detection and flame monitoring applications can be activated and tested. Most optical flame sensors respond to Ultra Violet (UV) and or InfraRed (IR) radiation emitted from flames during combustion. Many sensors also use flame flicker techniques to distinguish between flames and other optical false sources. The test unit simulates the flickering flame signal by modulating the output of a filament lamp. The thermal time constant of a filament lamp prevents the generation of a perfect flame flicker signal. The slow response of the filament lamp will mean that some flame sensors many require more time to activate under test than they would with a real flame. Ideal for testing flame detectors Wide Spectral Output - UV, Visible, Near IR, Mid-IR Tests many Flame Sensors Types UV, UVIR, UVIR², IR³, IR², IR Conforms to NFPA 72 Chapter 14 (14.4.3) Portable with Rechargeable NiCd Battery Pack and Charger 12V 7 Ah maintenance free leak proof sealed battery Selectable Optical Output Type Constant Illumination Regular Flashing Sources (Range of Frequencies)
Corporate Fire Detector
1,200 Per Piece
Fire Detection, Protection Products
Get Price Quote
ANY VALUES Piece (MOQ)
manufacturers and authorized agent of various type of fire detection and protection products including nitie; apollo and airsense brands and also lstk project undertaking of various fire detection and protection such as hydrants; water based protection products and also installations of gaseous fire suppression products etc.
Flame Detectors
Get Price Quote
Now, the so far separated units flame sensor and flame evaluation device, are merged to one compact unit. Therewith the mounting – and commissioning efforts are reduced vastly. The device is designed for 72 h continuous operation. It is interference radiation safe i.e. it can be used with boilers, which have to be x-rayed periodically. No fault will occur during the x-ray procedure.